{"product_id":"so-low-ultra-low-energy-efficient-upright-freezer-vsu85-22","title":"So-Low Ultra Low Energy Efficient Upright Freezer VSU85-22","description":"\u003ch3 data-start=\"348\" data-end=\"435\"\u003eSmart High-Capacity -85°C Ultra-Low Freezer with Advanced Monitoring \u0026amp; Data Logging\u003c\/h3\u003e\n\u003cp data-start=\"437\" data-end=\"887\"\u003eThis \u003cstrong data-start=\"442\" data-end=\"489\"\u003e22 cubic foot ultra-low temperature freezer\u003c\/strong\u003e delivers dependable \u003cstrong data-start=\"510\" data-end=\"531\"\u003e-85°C performance\u003c\/strong\u003e while integrating \u003cstrong data-start=\"550\" data-end=\"587\"\u003etouchscreen dual-display controls\u003c\/strong\u003e, \u003cstrong data-start=\"589\" data-end=\"610\"\u003eremote monitoring\u003c\/strong\u003e, and an \u003cstrong data-start=\"619\" data-end=\"680\"\u003eenergy-efficient variable-speed cascade compressor system\u003c\/strong\u003e. Designed for laboratories seeking \u003cstrong data-start=\"716\" data-end=\"802\"\u003ehigh storage capacity, reduced energy consumption, and compliance-ready monitoring\u003c\/strong\u003e, this unit is ideal for pharmaceutical, biotech, and clinical research environments.\u003c\/p\u003e\n\u003chr data-start=\"889\" data-end=\"892\"\u003e\n\u003ch2 data-start=\"894\" data-end=\"920\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"922\" data-end=\"2046\"\u003e\n\u003cli data-start=\"922\" data-end=\"1015\"\u003e\n\u003cp data-start=\"924\" data-end=\"1015\"\u003e\u003cstrong data-start=\"924\" data-end=\"962\"\u003eUltra-Low Temperature Performance:\u003c\/strong\u003e Adjustable from \u003cstrong data-start=\"979\" data-end=\"997\"\u003e-40°C to -85°C\u003c\/strong\u003e (-40°F to -120°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1016\" data-end=\"1103\"\u003e\n\u003cp data-start=\"1018\" data-end=\"1103\"\u003e\u003cstrong data-start=\"1018\" data-end=\"1044\"\u003eHigh-Capacity Storage:\u003c\/strong\u003e \u003cstrong data-start=\"1045\" data-end=\"1072\"\u003e22 cu. ft. (626 liters)\u003c\/strong\u003e for growing sample inventories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1104\" data-end=\"1211\"\u003e\n\u003cp data-start=\"1106\" data-end=\"1211\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1146\"\u003eTouchscreen Dual Display Controller:\u003c\/strong\u003e Intuitive interface for precise control and real-time monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1212\" data-end=\"1339\"\u003e\n\u003cp data-start=\"1214\" data-end=\"1339\"\u003e\u003cstrong data-start=\"1214\" data-end=\"1261\"\u003eEnergy-Efficient Variable-Speed Compressor:\u003c\/strong\u003e Optimizes cooling performance while reducing energy usage and operating noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1458\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1376\"\u003e\u003cstrong data-start=\"1342\" data-end=\"1374\"\u003eRemote Monitoring \u0026amp; Control:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1379\" data-end=\"1458\"\u003e\n\u003cli data-start=\"1379\" data-end=\"1415\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1415\"\u003eSMS \u0026amp; Email alarm notifications*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1458\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1458\"\u003eVNC remote access via local network*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1459\" data-end=\"1552\"\u003e\n\u003cp data-start=\"1461\" data-end=\"1552\"\u003e\u003cstrong data-start=\"1461\" data-end=\"1497\"\u003eIntegrated Temperature Recorder:\u003c\/strong\u003e On-screen temperature graph with historical visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1624\"\u003e\n\u003cp data-start=\"1555\" data-end=\"1624\"\u003e\u003cstrong data-start=\"1555\" data-end=\"1579\"\u003eData Export Options:\u003c\/strong\u003e Download temperature logs via \u003cstrong data-start=\"1610\" data-end=\"1624\"\u003eUSB or FTP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1625\" data-end=\"1682\"\u003e\n\u003cp data-start=\"1627\" data-end=\"1682\"\u003e\u003cstrong data-start=\"1627\" data-end=\"1652\"\u003eNetwork Connectivity:\u003c\/strong\u003e Hardwired \u003cstrong data-start=\"1663\" data-end=\"1682\"\u003eEthernet (RJ45)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1683\" data-end=\"1774\"\u003e\n\u003cp data-start=\"1685\" data-end=\"1774\"\u003e\u003cstrong data-start=\"1685\" data-end=\"1718\"\u003eMulti-Level Control Security:\u003c\/strong\u003e User-based access management for regulated environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1775\" data-end=\"1862\"\u003e\n\u003cp data-start=\"1777\" data-end=\"1862\"\u003e\u003cstrong data-start=\"1777\" data-end=\"1812\"\u003eComprehensive Alarm Protection:\u003c\/strong\u003e Audible high\/low alarms and power failure alerts*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1863\" data-end=\"1968\"\u003e\n\u003cp data-start=\"1865\" data-end=\"1968\"\u003e\u003cstrong data-start=\"1865\" data-end=\"1898\"\u003eCascade Refrigeration System:\u003c\/strong\u003e Hermetic compressor design for stable ultra-low temperature operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1969\" data-end=\"2046\"\u003e\n\u003cp data-start=\"1971\" data-end=\"2046\"\u003e\u003cstrong data-start=\"1971\" data-end=\"2017\"\u003eEnvironmentally Responsible Refrigeration:\u003c\/strong\u003e CFC \u0026amp; HCFC-free refrigerants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2048\" data-end=\"2051\"\u003e\n\u003ch2 data-start=\"2053\" data-end=\"2077\"\u003eCapacity \u0026amp; Dimensions\u003c\/h2\u003e\n\u003cp data-start=\"2079\" data-end=\"2099\"\u003e\u003cstrong data-start=\"2079\" data-end=\"2099\"\u003eStorage Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2100\" data-end=\"2132\"\u003e\n\u003cli data-start=\"2100\" data-end=\"2132\"\u003e\n\u003cp data-start=\"2102\" data-end=\"2132\"\u003e\u003cstrong data-start=\"2102\" data-end=\"2119\"\u003e22 Cubic Feet\u003c\/strong\u003e (626 Liters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2134\" data-end=\"2157\"\u003e\u003cstrong data-start=\"2134\" data-end=\"2157\"\u003eExterior Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2158\" data-end=\"2216\"\u003e\n\u003cli data-start=\"2158\" data-end=\"2192\"\u003e\n\u003cp data-start=\"2160\" data-end=\"2192\"\u003e\u003cstrong data-start=\"2160\" data-end=\"2190\"\u003e41.25\" W x 37\" D x 79.5\" H\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2193\" data-end=\"2216\"\u003e\n\u003cp data-start=\"2195\" data-end=\"2216\"\u003e\u003cstrong data-start=\"2195\" data-end=\"2216\"\u003e105 x 93 x 201 cm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2218\" data-end=\"2241\"\u003e\u003cstrong data-start=\"2218\" data-end=\"2241\"\u003eInterior Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2242\" data-end=\"2299\"\u003e\n\u003cli data-start=\"2242\" data-end=\"2276\"\u003e\n\u003cp data-start=\"2244\" data-end=\"2276\"\u003e\u003cstrong data-start=\"2244\" data-end=\"2274\"\u003e28.5\" W x 26\" D x 51.25\" H\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2277\" data-end=\"2299\"\u003e\n\u003cp data-start=\"2279\" data-end=\"2299\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2299\"\u003e72 x 66 x 130 cm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2301\" data-end=\"2304\"\u003e\n\u003ch2 data-start=\"2306\" data-end=\"2334\"\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"2336\" data-end=\"2503\"\u003e\n\u003cli data-start=\"2336\" data-end=\"2377\"\u003e\n\u003cp data-start=\"2338\" data-end=\"2377\"\u003e\u003cstrong data-start=\"2338\" data-end=\"2363\"\u003e115V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 5-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2378\" data-end=\"2419\"\u003e\n\u003cp data-start=\"2380\" data-end=\"2419\"\u003e\u003cstrong data-start=\"2380\" data-end=\"2405\"\u003e208V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 6-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2420\" data-end=\"2461\"\u003e\n\u003cp data-start=\"2422\" data-end=\"2461\"\u003e\u003cstrong data-start=\"2422\" data-end=\"2447\"\u003e230V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 6-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2462\" data-end=\"2503\"\u003e\n\u003cp data-start=\"2464\" data-end=\"2503\"\u003e\u003cem data-start=\"2464\" data-end=\"2503\"\u003eOther voltages available upon request\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2505\" data-end=\"2535\"\u003e\u003cstrong data-start=\"2505\" data-end=\"2524\"\u003eCertifications:\u003c\/strong\u003e ETL Listed\u003c\/p\u003e\n\u003chr data-start=\"2537\" data-end=\"2540\"\u003e\n\u003ch2 data-start=\"2542\" data-end=\"2574\"\u003eControls, Monitoring \u0026amp; Alarms\u003c\/h2\u003e\n\u003cul data-start=\"2576\" data-end=\"2982\"\u003e\n\u003cli data-start=\"2576\" data-end=\"2629\"\u003e\n\u003cp data-start=\"2578\" data-end=\"2629\"\u003e\u003cstrong data-start=\"2578\" data-end=\"2602\"\u003eTemperature Control:\u003c\/strong\u003e Touchscreen dual display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2630\" data-end=\"2675\"\u003e\n\u003cp data-start=\"2632\" data-end=\"2675\"\u003e\u003cstrong data-start=\"2632\" data-end=\"2654\"\u003eTemperature Alarm:\u003c\/strong\u003e Audible high \/ low\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2676\" data-end=\"2717\"\u003e\n\u003cp data-start=\"2678\" data-end=\"2717\"\u003e\u003cstrong data-start=\"2678\" data-end=\"2700\"\u003eAdditional Alarms:\u003c\/strong\u003e Power failure*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2718\" data-end=\"2766\"\u003e\n\u003cp data-start=\"2720\" data-end=\"2766\"\u003e\u003cstrong data-start=\"2720\" data-end=\"2744\"\u003eAlarm Notifications:\u003c\/strong\u003e SMS \/ Email alerts*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2767\" data-end=\"2813\"\u003e\n\u003cp data-start=\"2769\" data-end=\"2813\"\u003e\u003cstrong data-start=\"2769\" data-end=\"2788\"\u003eRemote Control:\u003c\/strong\u003e VNC via local network*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2814\" data-end=\"2870\"\u003e\n\u003cp data-start=\"2816\" data-end=\"2870\"\u003e\u003cstrong data-start=\"2816\" data-end=\"2841\"\u003eTemperature Recorder:\u003c\/strong\u003e Viewable temperature graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2871\" data-end=\"2904\"\u003e\n\u003cp data-start=\"2873\" data-end=\"2904\"\u003e\u003cstrong data-start=\"2873\" data-end=\"2891\"\u003eData Download:\u003c\/strong\u003e USB or FTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2905\" data-end=\"2948\"\u003e\n\u003cp data-start=\"2907\" data-end=\"2948\"\u003e\u003cstrong data-start=\"2907\" data-end=\"2930\"\u003eNetwork Connection:\u003c\/strong\u003e Ethernet (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2949\" data-end=\"2982\"\u003e\n\u003cp data-start=\"2951\" data-end=\"2982\"\u003e\u003cstrong data-start=\"2951\" data-end=\"2967\"\u003eAlarm Relay:\u003c\/strong\u003e Dry contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2984\" data-end=\"2987\"\u003e\n\u003ch2 data-start=\"2989\" data-end=\"3022\"\u003eConstruction \u0026amp; Storage Details\u003c\/h2\u003e\n\u003cul data-start=\"3024\" data-end=\"3500\"\u003e\n\u003cli data-start=\"3024\" data-end=\"3052\"\u003e\n\u003cp data-start=\"3026\" data-end=\"3052\"\u003e\u003cstrong data-start=\"3026\" data-end=\"3043\"\u003eDefrost Type:\u003c\/strong\u003e Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3053\" data-end=\"3090\"\u003e\n\u003cp data-start=\"3055\" data-end=\"3090\"\u003e\u003cstrong data-start=\"3055\" data-end=\"3075\"\u003eAir Circulation:\u003c\/strong\u003e Gravity flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3091\" data-end=\"3141\"\u003e\n\u003cp data-start=\"3093\" data-end=\"3141\"\u003e\u003cstrong data-start=\"3093\" data-end=\"3108\"\u003eInsulation:\u003c\/strong\u003e High-density polyurethane foam\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3142\" data-end=\"3186\"\u003e\n\u003cp data-start=\"3144\" data-end=\"3186\"\u003e\u003cstrong data-start=\"3144\" data-end=\"3164\"\u003eExterior Finish:\u003c\/strong\u003e Powder-coated steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3187\" data-end=\"3228\"\u003e\n\u003cp data-start=\"3189\" data-end=\"3228\"\u003e\u003cstrong data-start=\"3189\" data-end=\"3209\"\u003eInterior Finish:\u003c\/strong\u003e Galvanized steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3229\" data-end=\"3292\"\u003e\n\u003cp data-start=\"3231\" data-end=\"3292\"\u003e\u003cstrong data-start=\"3231\" data-end=\"3254\"\u003eDoor Configuration:\u003c\/strong\u003e 1 front door, lockable with padlock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3293\" data-end=\"3343\"\u003e\n\u003cp data-start=\"3295\" data-end=\"3343\"\u003e\u003cstrong data-start=\"3295\" data-end=\"3311\"\u003eInner Doors:\u003c\/strong\u003e 5 stainless steel inner doors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3344\" data-end=\"3400\"\u003e\n\u003cp data-start=\"3346\" data-end=\"3400\"\u003e\u003cstrong data-start=\"3346\" data-end=\"3359\"\u003eShelving:\u003c\/strong\u003e 4 adjustable shelves plus 1 base shelf\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3401\" data-end=\"3452\"\u003e\n\u003cp data-start=\"3403\" data-end=\"3452\"\u003e\u003cstrong data-start=\"3403\" data-end=\"3421\"\u003eRack Capacity:\u003c\/strong\u003e Up to \u003cstrong data-start=\"3428\" data-end=\"3450\"\u003e25 inventory racks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3453\" data-end=\"3500\"\u003e\n\u003cp data-start=\"3455\" data-end=\"3500\"\u003e\u003cstrong data-start=\"3455\" data-end=\"3467\"\u003eCasters:\u003c\/strong\u003e 4 heavy-duty, lockable casters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3502\" data-end=\"3505\"\u003e\n\u003ch2 data-start=\"3507\" data-end=\"3518\"\u003eWarranty\u003c\/h2\u003e\n\u003cul data-start=\"3520\" data-end=\"3555\"\u003e\n\u003cli data-start=\"3520\" data-end=\"3555\"\u003e\n\u003cp data-start=\"3522\" data-end=\"3555\"\u003e\u003cstrong data-start=\"3522\" data-end=\"3555\"\u003e1-Year Parts \u0026amp; Labor Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3557\" data-end=\"3560\"\u003e\n\u003ch2 data-start=\"3562\" data-end=\"3583\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul data-start=\"3585\" data-end=\"3785\"\u003e\n\u003cli data-start=\"3585\" data-end=\"3628\"\u003e\n\u003cp data-start=\"3587\" data-end=\"3628\"\u003ePharmaceutical and biotech laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3629\" data-end=\"3673\"\u003e\n\u003cp data-start=\"3631\" data-end=\"3673\"\u003eMedical and clinical research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3674\" data-end=\"3700\"\u003e\n\u003cp data-start=\"3676\" data-end=\"3700\"\u003eGMP \/ GLP environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3701\" data-end=\"3742\"\u003e\n\u003cp data-start=\"3703\" data-end=\"3742\"\u003eVaccine and biological sample storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3743\" data-end=\"3785\"\u003e\n\u003cp data-start=\"3745\" data-end=\"3785\"\u003eUniversities and research institutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3787\" data-end=\"3790\"\u003e\n\u003ch3 data-start=\"3792\" data-end=\"3840\"\u003eImportant Notes on Alarm \u0026amp; Network Operation\u003c\/h3\u003e\n\u003cp data-start=\"3841\" data-end=\"4123\"\u003e* Battery backup powers \u003cstrong data-start=\"3866\" data-end=\"3906\"\u003eonly the alarm and recording devices\u003c\/strong\u003e. Network equipment such as routers or switches must have independent backup power for remote alerts to function during a power outage. Consult your IT department or internet provider for network continuity solutions.\u003c\/p\u003e\n\u003chr data-start=\"4125\" data-end=\"4128\"\u003e\n\u003cp data-start=\"4130\" data-end=\"4188\"\u003e\u003cstrong data-start=\"4130\" data-end=\"4139\"\u003eNote:\u003c\/strong\u003e Specifications subject to change without notice.\u003c\/p\u003e","brand":"So-Low","offers":[{"title":"Default Title","offer_id":51820128960834,"sku":null,"price":14450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/VSU85-13__88032_d3934834-337f-4f86-90bb-fed1fc0227a2.webp?v=1768192076","url":"https:\/\/summitsupplydirect.com\/products\/so-low-ultra-low-energy-efficient-upright-freezer-vsu85-22","provider":"Summit Supply Direct","version":"1.0","type":"link"}