{"product_id":"so-low-ultra-low-energy-efficient-chest-freezer-vsc40-9","title":"So-Low Ultra Low Energy Efficient Chest Freezer VSC40-9","description":"\u003ch3 data-start=\"321\" data-end=\"434\"\u003eMid-Large Capacity -40°C Laboratory Freezer with Advanced Controls, Data Logging \u0026amp; Energy-Efficient Operation\u003c\/h3\u003e\n\u003cp data-start=\"436\" data-end=\"872\"\u003eThis \u003cstrong data-start=\"441\" data-end=\"482\"\u003e9 cubic foot laboratory chest freezer\u003c\/strong\u003e delivers dependable \u003cstrong data-start=\"503\" data-end=\"520\"\u003e-40°C (-40°F)\u003c\/strong\u003e performance combined with \u003cstrong data-start=\"547\" data-end=\"637\"\u003eadvanced touchscreen controls, remote monitoring, and integrated temperature recording\u003c\/strong\u003e. Designed for laboratories that require \u003cstrong data-start=\"678\" data-end=\"754\"\u003esecure sample storage, regulatory compliance, and operational efficiency\u003c\/strong\u003e, this unit features an \u003cstrong data-start=\"778\" data-end=\"824\"\u003eenergy-efficient variable-speed compressor\u003c\/strong\u003e and a compact footprint for flexible placement.\u003c\/p\u003e\n\u003chr data-start=\"874\" data-end=\"877\"\u003e\n\u003ch2 data-start=\"879\" data-end=\"905\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul data-start=\"907\" data-end=\"1824\"\u003e\n\u003cli data-start=\"907\" data-end=\"966\"\u003e\n\u003cp data-start=\"909\" data-end=\"966\"\u003e\u003cstrong data-start=\"909\" data-end=\"931\"\u003eTemperature Range:\u003c\/strong\u003e \u003cstrong data-start=\"932\" data-end=\"948\"\u003e0°C to -40°C\u003c\/strong\u003e (32°F to -40°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1019\"\u003e\n\u003cp data-start=\"969\" data-end=\"1019\"\u003e\u003cstrong data-start=\"969\" data-end=\"990\"\u003eStorage Capacity:\u003c\/strong\u003e \u003cstrong data-start=\"991\" data-end=\"1017\"\u003e9 cu. ft. (255 liters)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1020\" data-end=\"1110\"\u003e\n\u003cp data-start=\"1022\" data-end=\"1110\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1062\"\u003eTouchscreen Dual Display Controller:\u003c\/strong\u003e Intuitive, easy-to-read temperature interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1111\" data-end=\"1226\"\u003e\n\u003cp data-start=\"1113\" data-end=\"1226\"\u003e\u003cstrong data-start=\"1113\" data-end=\"1160\"\u003eEnergy-Efficient Variable-Speed Compressor:\u003c\/strong\u003e Improved temperature stability, lower energy use, reduced noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1227\" data-end=\"1344\"\u003e\n\u003cp data-start=\"1229\" data-end=\"1262\"\u003e\u003cstrong data-start=\"1229\" data-end=\"1260\"\u003eRemote Monitoring \u0026amp; Alerts:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1265\" data-end=\"1344\"\u003e\n\u003cli data-start=\"1265\" data-end=\"1301\"\u003e\n\u003cp data-start=\"1267\" data-end=\"1301\"\u003eSMS \u0026amp; Email alarm notifications*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1344\"\u003e\n\u003cp data-start=\"1306\" data-end=\"1344\"\u003eVNC remote access via local network*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1345\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1347\" data-end=\"1439\"\u003e\u003cstrong data-start=\"1347\" data-end=\"1383\"\u003eIntegrated Temperature Recorder:\u003c\/strong\u003e On-screen temperature graph for audits and compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1440\" data-end=\"1480\"\u003e\n\u003cp data-start=\"1442\" data-end=\"1480\"\u003e\u003cstrong data-start=\"1442\" data-end=\"1458\"\u003eData Export:\u003c\/strong\u003e USB or FTP download\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1483\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1483\" data-end=\"1508\"\u003eNetwork Connectivity:\u003c\/strong\u003e Hardwired Ethernet (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1537\" data-end=\"1597\"\u003e\n\u003cp data-start=\"1539\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1539\" data-end=\"1572\"\u003eMulti-Level Control Security:\u003c\/strong\u003e User access management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1600\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1600\" data-end=\"1635\"\u003eComprehensive Alarm Protection:\u003c\/strong\u003e Audible high\/low temperature alarms with power-failure alerts*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1772\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1772\"\u003e\u003cstrong data-start=\"1703\" data-end=\"1722\"\u003eSecure Storage:\u003c\/strong\u003e Lockable top-opening lid with padlock provision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1773\" data-end=\"1824\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1824\"\u003e\u003cstrong data-start=\"1775\" data-end=\"1806\"\u003eEco-Friendly Refrigeration:\u003c\/strong\u003e CFC \u0026amp; HCFC-free\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1826\" data-end=\"1829\"\u003e\n\u003ch2 data-start=\"1831\" data-end=\"1855\"\u003eCapacity \u0026amp; Dimensions\u003c\/h2\u003e\n\u003cp data-start=\"1857\" data-end=\"1879\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1877\"\u003eStorage Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1880\" data-end=\"1911\"\u003e\n\u003cli data-start=\"1880\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1911\"\u003e\u003cstrong data-start=\"1882\" data-end=\"1898\"\u003e9 Cubic Feet\u003c\/strong\u003e (255 Liters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1913\" data-end=\"1938\"\u003e\u003cstrong data-start=\"1913\" data-end=\"1936\"\u003eExterior Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1939\" data-end=\"1996\"\u003e\n\u003cli data-start=\"1939\" data-end=\"1972\"\u003e\n\u003cp data-start=\"1941\" data-end=\"1972\"\u003e\u003cstrong data-start=\"1941\" data-end=\"1970\"\u003e57.5\" W x 29\" D x 46.5\" H\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1973\" data-end=\"1996\"\u003e\n\u003cp data-start=\"1975\" data-end=\"1996\"\u003e\u003cstrong data-start=\"1975\" data-end=\"1996\"\u003e146 x 73 x 116 cm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1998\" data-end=\"2023\"\u003e\u003cstrong data-start=\"1998\" data-end=\"2021\"\u003eInterior Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2024\" data-end=\"2078\"\u003e\n\u003cli data-start=\"2024\" data-end=\"2055\"\u003e\n\u003cp data-start=\"2026\" data-end=\"2055\"\u003e\u003cstrong data-start=\"2026\" data-end=\"2053\"\u003e45.5\" W x 16\" D x 20\" H\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2056\" data-end=\"2078\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2078\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2078\"\u003e115 x 40 x 50 cm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2080\" data-end=\"2083\"\u003e\n\u003ch2 data-start=\"2085\" data-end=\"2113\"\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"2115\" data-end=\"2282\"\u003e\n\u003cli data-start=\"2115\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2156\"\u003e\u003cstrong data-start=\"2117\" data-end=\"2142\"\u003e115V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 5-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2198\"\u003e\n\u003cp data-start=\"2159\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2184\"\u003e208V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 6-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2240\"\u003e\n\u003cp data-start=\"2201\" data-end=\"2240\"\u003e\u003cstrong data-start=\"2201\" data-end=\"2226\"\u003e230V \/ 60Hz \/ 1 Phase\u003c\/strong\u003e – NEMA 6-15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2241\" data-end=\"2282\"\u003e\n\u003cp data-start=\"2243\" data-end=\"2282\"\u003e\u003cem data-start=\"2243\" data-end=\"2282\"\u003eOther voltages available upon request\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2284\" data-end=\"2314\"\u003e\u003cstrong data-start=\"2284\" data-end=\"2303\"\u003eCertifications:\u003c\/strong\u003e ETL Listed\u003c\/p\u003e\n\u003chr data-start=\"2316\" data-end=\"2319\"\u003e\n\u003ch2 data-start=\"2321\" data-end=\"2353\"\u003eControls, Monitoring \u0026amp; Alarms\u003c\/h2\u003e\n\u003cul data-start=\"2355\" data-end=\"2754\"\u003e\n\u003cli data-start=\"2355\" data-end=\"2408\"\u003e\n\u003cp data-start=\"2357\" data-end=\"2408\"\u003e\u003cstrong data-start=\"2357\" data-end=\"2381\"\u003eTemperature Control:\u003c\/strong\u003e Touchscreen dual display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2409\" data-end=\"2454\"\u003e\n\u003cp data-start=\"2411\" data-end=\"2454\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2433\"\u003eTemperature Alarm:\u003c\/strong\u003e Audible high \/ low\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2455\" data-end=\"2496\"\u003e\n\u003cp data-start=\"2457\" data-end=\"2496\"\u003e\u003cstrong data-start=\"2457\" data-end=\"2479\"\u003eAdditional Alarms:\u003c\/strong\u003e Power failure*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2497\" data-end=\"2538\"\u003e\n\u003cp data-start=\"2499\" data-end=\"2538\"\u003e\u003cstrong data-start=\"2499\" data-end=\"2523\"\u003eAlarm Notifications:\u003c\/strong\u003e SMS \/ Email*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2539\" data-end=\"2585\"\u003e\n\u003cp data-start=\"2541\" data-end=\"2585\"\u003e\u003cstrong data-start=\"2541\" data-end=\"2560\"\u003eRemote Control:\u003c\/strong\u003e VNC via local network*\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2586\" data-end=\"2642\"\u003e\n\u003cp data-start=\"2588\" data-end=\"2642\"\u003e\u003cstrong data-start=\"2588\" data-end=\"2613\"\u003eTemperature Recorder:\u003c\/strong\u003e Viewable temperature graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2643\" data-end=\"2676\"\u003e\n\u003cp data-start=\"2645\" data-end=\"2676\"\u003e\u003cstrong data-start=\"2645\" data-end=\"2663\"\u003eData Download:\u003c\/strong\u003e USB or FTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2677\" data-end=\"2720\"\u003e\n\u003cp data-start=\"2679\" data-end=\"2720\"\u003e\u003cstrong data-start=\"2679\" data-end=\"2702\"\u003eNetwork Connection:\u003c\/strong\u003e Ethernet (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2721\" data-end=\"2754\"\u003e\n\u003cp data-start=\"2723\" data-end=\"2754\"\u003e\u003cstrong data-start=\"2723\" data-end=\"2739\"\u003eAlarm Relay:\u003c\/strong\u003e Dry contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2756\" data-end=\"2759\"\u003e\n\u003ch2 data-start=\"2761\" data-end=\"2794\"\u003eConstruction \u0026amp; Storage Details\u003c\/h2\u003e\n\u003cul data-start=\"2796\" data-end=\"3243\"\u003e\n\u003cli data-start=\"2796\" data-end=\"2824\"\u003e\n\u003cp data-start=\"2798\" data-end=\"2824\"\u003e\u003cstrong data-start=\"2798\" data-end=\"2815\"\u003eDefrost Type:\u003c\/strong\u003e Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2825\" data-end=\"2862\"\u003e\n\u003cp data-start=\"2827\" data-end=\"2862\"\u003e\u003cstrong data-start=\"2827\" data-end=\"2847\"\u003eAir Circulation:\u003c\/strong\u003e Gravity flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2863\" data-end=\"2924\"\u003e\n\u003cp data-start=\"2865\" data-end=\"2924\"\u003e\u003cstrong data-start=\"2865\" data-end=\"2880\"\u003eCompressor:\u003c\/strong\u003e Hermetic, energy-efficient variable-speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2925\" data-end=\"2975\"\u003e\n\u003cp data-start=\"2927\" data-end=\"2975\"\u003e\u003cstrong data-start=\"2927\" data-end=\"2942\"\u003eInsulation:\u003c\/strong\u003e High-density polyurethane foam\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2976\" data-end=\"3014\"\u003e\n\u003cp data-start=\"2978\" data-end=\"3014\"\u003e\u003cstrong data-start=\"2978\" data-end=\"2996\"\u003eOpening Style:\u003c\/strong\u003e Top-opening lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3015\" data-end=\"3060\"\u003e\n\u003cp data-start=\"3017\" data-end=\"3060\"\u003e\u003cstrong data-start=\"3017\" data-end=\"3039\"\u003eLocking Mechanism:\u003c\/strong\u003e Padlock compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3061\" data-end=\"3106\"\u003e\n\u003cp data-start=\"3063\" data-end=\"3106\"\u003e\u003cstrong data-start=\"3063\" data-end=\"3081\"\u003eRack Capacity:\u003c\/strong\u003e \u003cstrong data-start=\"3082\" data-end=\"3104\"\u003e16 inventory racks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3107\" data-end=\"3151\"\u003e\n\u003cp data-start=\"3109\" data-end=\"3151\"\u003e\u003cstrong data-start=\"3109\" data-end=\"3129\"\u003eExterior Finish:\u003c\/strong\u003e Powder-coated steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3152\" data-end=\"3193\"\u003e\n\u003cp data-start=\"3154\" data-end=\"3193\"\u003e\u003cstrong data-start=\"3154\" data-end=\"3174\"\u003eInterior Finish:\u003c\/strong\u003e Galvanized steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3243\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3243\"\u003e\u003cstrong data-start=\"3196\" data-end=\"3209\"\u003eMobility:\u003c\/strong\u003e \u003cstrong data-start=\"3210\" data-end=\"3243\"\u003e4 heavy-duty lockable casters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3245\" data-end=\"3248\"\u003e\n\u003ch2 data-start=\"3250\" data-end=\"3261\"\u003eWarranty\u003c\/h2\u003e\n\u003cul data-start=\"3263\" data-end=\"3298\"\u003e\n\u003cli data-start=\"3263\" data-end=\"3298\"\u003e\n\u003cp data-start=\"3265\" data-end=\"3298\"\u003e\u003cstrong data-start=\"3265\" data-end=\"3298\"\u003e1-Year Parts \u0026amp; Labor Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3300\" data-end=\"3303\"\u003e\n\u003ch2 data-start=\"3305\" data-end=\"3326\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul data-start=\"3328\" data-end=\"3528\"\u003e\n\u003cli data-start=\"3328\" data-end=\"3371\"\u003e\n\u003cp data-start=\"3330\" data-end=\"3371\"\u003ePharmaceutical and biotech laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3372\" data-end=\"3410\"\u003e\n\u003cp data-start=\"3374\" data-end=\"3410\"\u003eClinical and diagnostic facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3411\" data-end=\"3450\"\u003e\n\u003cp data-start=\"3413\" data-end=\"3450\"\u003eResearch sample and reagent storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3451\" data-end=\"3487\"\u003e\n\u003cp data-start=\"3453\" data-end=\"3487\"\u003eGMP \/ GLP regulated environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3488\" data-end=\"3528\"\u003e\n\u003cp data-start=\"3490\" data-end=\"3528\"\u003eLong-term frozen sample preservation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3530\" data-end=\"3533\"\u003e\n\u003ch3 data-start=\"3535\" data-end=\"3575\"\u003eAlarm \u0026amp; Network Operation Disclaimer\u003c\/h3\u003e\n\u003cp data-start=\"3576\" data-end=\"3740\"\u003e* Battery backup powers \u003cstrong data-start=\"3601\" data-end=\"3637\"\u003eonly alarm and recording systems\u003c\/strong\u003e. Network devices (routers\/switches) require independent backup power for remote alerts during outages.\u003c\/p\u003e\n\u003cp data-start=\"3742\" data-end=\"3794\"\u003e\u003cstrong data-start=\"3742\" data-end=\"3794\"\u003eSpecifications subject to change without notice.\u003c\/strong\u003e\u003c\/p\u003e","brand":"So-Low","offers":[{"title":"Default Title","offer_id":51825820172610,"sku":null,"price":11260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/NC40-9_559013ec-86b4-4eb2-9a91-ecd15c5a2f1f.png?v=1768241156","url":"https:\/\/summitsupplydirect.com\/products\/so-low-ultra-low-energy-efficient-chest-freezer-vsc40-9","provider":"Summit Supply Direct","version":"1.0","type":"link"}