{"product_id":"across-international-ps-1000-r2-radwag-1000g-capacity-0-001g-readability-5x5-precision-balance","title":"Across International PS 1000.R2 Radwag 1000g Capacity 0.001g Readability 5x5\" Precision Balance","description":"\u003ch2 data-section-id=\"178hp1o\" data-start=\"411\" data-end=\"502\"\u003eHigh-Precision Laboratory Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"504\" data-end=\"719\"\u003eThe \u003cstrong data-start=\"508\" data-end=\"547\"\u003eRadwag RS 1000.R2 Precision Balance\u003c\/strong\u003e from the \u003cstrong data-start=\"557\" data-end=\"573\"\u003ePS.R2 series\u003c\/strong\u003e represents a new generation of precision laboratory balances designed for \u003cstrong data-start=\"648\" data-end=\"718\"\u003ehigh-accuracy weighing, data management, and laboratory automation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"721\" data-end=\"963\"\u003eWith a \u003cstrong data-start=\"728\" data-end=\"778\"\u003e1000 g capacity and 0.001 g (1 mg) readability\u003c\/strong\u003e, the RS 1000.R2 delivers precise mass measurements for laboratory applications including \u003cstrong data-start=\"868\" data-end=\"962\"\u003epharmaceutical analysis, chemical research, quality control, and industrial weighing tasks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"965\" data-end=\"1151\"\u003eThe balance features \u003cstrong data-start=\"986\" data-end=\"1019\"\u003eautomatic internal adjustment\u003c\/strong\u003e, which continuously compensates for temperature fluctuations and time-related changes to ensure accurate and reliable measurements.\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1365\"\u003eEquipped with a \u003cstrong data-start=\"1169\" data-end=\"1225\"\u003ebacklit LCD display with additional information line\u003c\/strong\u003e, the system allows users to display important data such as \u003cstrong data-start=\"1285\" data-end=\"1341\"\u003eproduct names, tare values, and operational messages\u003c\/strong\u003e directly on the screen.\u003c\/p\u003e\n\u003cp data-start=\"1367\" data-end=\"1551\"\u003eWith \u003cstrong data-start=\"1372\" data-end=\"1459\"\u003emultiple communication interfaces including RS232, USB-A, USB-B, and optional Wi-Fi\u003c\/strong\u003e, the RS 1000.R2 easily integrates with laboratory software, computers, and network systems.\u003c\/p\u003e\n\u003chr data-start=\"1553\" data-end=\"1556\"\u003e\n\u003ch1 data-section-id=\"lqxm4e\" data-start=\"1558\" data-end=\"1615\"\u003eKey Features of the Radwag RS 1000.R2 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"6gfpsk\" data-start=\"1617\" data-end=\"1647\"\u003eHigh Precision Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1648\" data-end=\"1781\"\u003eDelivers \u003cstrong data-start=\"1657\" data-end=\"1687\"\u003e0.001 g readability (1 mg)\u003c\/strong\u003e with \u003cstrong data-start=\"1693\" data-end=\"1720\"\u003e1000 g maximum capacity\u003c\/strong\u003e, providing excellent accuracy for laboratory weighing tasks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qxdg43\" data-start=\"1783\" data-end=\"1816\"\u003eAutomatic Internal Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"1817\" data-end=\"1949\"\u003eThe internal calibration system compensates for \u003cstrong data-start=\"1865\" data-end=\"1903\"\u003etemperature changes and time drift\u003c\/strong\u003e, maintaining consistent measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ovztu1\" data-start=\"1951\" data-end=\"1975\"\u003eAdvanced LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1976\" data-end=\"2056\"\u003eLarge \u003cstrong data-start=\"1982\" data-end=\"2037\"\u003ebacklit LCD screen with additional information line\u003c\/strong\u003e allows display of:\u003c\/p\u003e\n\u003cul data-start=\"2058\" data-end=\"2132\"\u003e\n\u003cli data-section-id=\"82fg7r\" data-start=\"2058\" data-end=\"2073\"\u003e\n\u003cp data-start=\"2060\" data-end=\"2073\"\u003eProduct names\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p3jhea\" data-start=\"2074\" data-end=\"2087\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2087\"\u003eTare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lid7ns\" data-start=\"2088\" data-end=\"2110\"\u003e\n\u003cp data-start=\"2090\" data-end=\"2110\"\u003eOperational messages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1acayfs\" data-start=\"2111\" data-end=\"2132\"\u003e\n\u003cp data-start=\"2113\" data-end=\"2132\"\u003eMeasurement results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"savnnm\" data-start=\"2134\" data-end=\"2166\"\u003eMulti-Interface Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2167\" data-end=\"2209\"\u003eBuilt-in communication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2211\" data-end=\"2281\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2211\" data-end=\"2226\"\u003e\n\u003cp data-start=\"2213\" data-end=\"2226\"\u003e\u003cstrong data-start=\"2213\" data-end=\"2226\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2227\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2229\" data-end=\"2243\"\u003e\u003cstrong data-start=\"2229\" data-end=\"2243\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2244\" data-end=\"2260\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2260\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2260\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"2261\" data-end=\"2281\"\u003e\n\u003cp data-start=\"2263\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2263\" data-end=\"2281\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2283\" data-end=\"2377\"\u003eThese allow seamless integration with computers, printers, and laboratory information systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"186nltk\" data-start=\"2379\" data-end=\"2412\"\u003eUnder-Pan Weighing Capability\u003c\/h3\u003e\n\u003cp data-start=\"2413\" data-end=\"2526\"\u003eSupports \u003cstrong data-start=\"2422\" data-end=\"2444\"\u003eunder-pan weighing\u003c\/strong\u003e, allowing samples to be suspended below the balance for specialized measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rynjla\" data-start=\"2528\" data-end=\"2560\"\u003eStainless Steel Weighing Pan\u003c\/h3\u003e\n\u003cp data-start=\"2561\" data-end=\"2661\"\u003eDurable \u003cstrong data-start=\"2569\" data-end=\"2606\"\u003estainless steel weighing platform\u003c\/strong\u003e ensures corrosion resistance and long-term durability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"692exr\" data-start=\"2663\" data-end=\"2690\"\u003eDraft Shield Protection\u003c\/h3\u003e\n\u003cp data-start=\"2691\" data-end=\"2795\"\u003eBalances with smaller pans include a \u003cstrong data-start=\"2728\" data-end=\"2744\"\u003edraft shield\u003c\/strong\u003e to protect measurements from airflow disturbances.\u003c\/p\u003e\n\u003chr data-start=\"2797\" data-end=\"2800\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"2802\" data-end=\"2837\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"2839\" data-end=\"3008\"\u003eThe PS.R2 balance series includes an advanced \u003cstrong data-start=\"2885\" data-end=\"2940\"\u003edata management system with five internal databases\u003c\/strong\u003e, enabling efficient organization and traceability of weighing data.\u003c\/p\u003e\n\u003ch3 data-section-id=\"x21cix\" data-start=\"3010\" data-end=\"3033\"\u003eAvailable Databases\u003c\/h3\u003e\n\u003cp data-start=\"3035\" data-end=\"3088\"\u003eThe system can store data in five internal databases:\u003c\/p\u003e\n\u003cul data-start=\"3090\" data-end=\"3282\"\u003e\n\u003cli data-section-id=\"biapsd\" data-start=\"3090\" data-end=\"3117\"\u003e\n\u003cp data-start=\"3092\" data-end=\"3117\"\u003e\u003cstrong data-start=\"3092\" data-end=\"3102\"\u003eUsers:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6qakdp\" data-start=\"3118\" data-end=\"3153\"\u003e\n\u003cp data-start=\"3120\" data-end=\"3153\"\u003e\u003cstrong data-start=\"3120\" data-end=\"3133\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bc5kud\" data-start=\"3154\" data-end=\"3195\"\u003e\n\u003cp data-start=\"3156\" data-end=\"3195\"\u003e\u003cstrong data-start=\"3156\" data-end=\"3171\"\u003eWeighments:\u003c\/strong\u003e up to 5000 measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nh3aza\" data-start=\"3196\" data-end=\"3230\"\u003e\n\u003cp data-start=\"3198\" data-end=\"3230\"\u003e\u003cstrong data-start=\"3198\" data-end=\"3208\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g1mdbr\" data-start=\"3231\" data-end=\"3282\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3282\"\u003e\u003cstrong data-start=\"3233\" data-end=\"3250\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighment records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"rz7j0t\" data-start=\"3284\" data-end=\"3307\"\u003eALIBI Memory System\u003c\/h3\u003e\n\u003cp data-start=\"3309\" data-end=\"3507\"\u003eThe integrated \u003cstrong data-start=\"3324\" data-end=\"3340\"\u003eALIBI memory\u003c\/strong\u003e stores up to \u003cstrong data-start=\"3354\" data-end=\"3383\"\u003e100,000 weighment records\u003c\/strong\u003e in a secure, tamper-proof data area, ensuring reliable record keeping for long-term traceability and regulatory compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b24h3h\" data-start=\"3509\" data-end=\"3537\"\u003eUSB Data Import \u0026amp; Export\u003c\/h3\u003e\n\u003cp data-start=\"3539\" data-end=\"3645\"\u003eDatabases can be \u003cstrong data-start=\"3556\" data-end=\"3603\"\u003eimported or exported using USB flash drives\u003c\/strong\u003e, enabling quick data transfer and backup.\u003c\/p\u003e\n\u003chr data-start=\"3647\" data-end=\"3650\"\u003e\n\u003ch1 data-section-id=\"cgez46\" data-start=\"3652\" data-end=\"3678\"\u003eEasy Access to Functions\u003c\/h1\u003e\n\u003cp data-start=\"3680\" data-end=\"3810\"\u003eThe balance features \u003cstrong data-start=\"3701\" data-end=\"3760\"\u003equick navigation keys and programmable function buttons\u003c\/strong\u003e, providing fast access to commonly used features.\u003c\/p\u003e\n\u003cul data-start=\"3812\" data-end=\"3924\"\u003e\n\u003cli data-section-id=\"su8a6k\" data-start=\"3812\" data-end=\"3844\"\u003e\n\u003cp data-start=\"3814\" data-end=\"3844\"\u003eDirect access to \u003cstrong data-start=\"3831\" data-end=\"3844\"\u003edatabases\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4se1al\" data-start=\"3845\" data-end=\"3885\"\u003e\n\u003cp data-start=\"3847\" data-end=\"3885\"\u003eDirect access to \u003cstrong data-start=\"3864\" data-end=\"3885\"\u003ebalance functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iia02z\" data-start=\"3886\" data-end=\"3924\"\u003e\n\u003cp data-start=\"3888\" data-end=\"3924\"\u003e\u003cstrong data-start=\"3888\" data-end=\"3924\"\u003eF1–F4 programmable function keys\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3926\" data-end=\"3929\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3931\" data-end=\"3951\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3953\" data-end=\"4013\"\u003eThe Radwag RS 1000.R2 precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"4015\" data-end=\"4183\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"4015\" data-end=\"4044\"\u003e\n\u003cp data-start=\"4017\" data-end=\"4044\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nbcj6d\" data-start=\"4045\" data-end=\"4064\"\u003e\n\u003cp data-start=\"4047\" data-end=\"4064\"\u003eChemical research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tnvors\" data-start=\"4065\" data-end=\"4088\"\u003e\n\u003cp data-start=\"4067\" data-end=\"4088\"\u003eAcademic laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"apgb38\" data-start=\"4089\" data-end=\"4119\"\u003e\n\u003cp data-start=\"4091\" data-end=\"4119\"\u003eQuality control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m7dh3m\" data-start=\"4120\" data-end=\"4151\"\u003e\n\u003cp data-start=\"4122\" data-end=\"4151\"\u003eMaterial science laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cqen8a\" data-start=\"4152\" data-end=\"4183\"\u003e\n\u003cp data-start=\"4154\" data-end=\"4183\"\u003eIndustrial testing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4185\" data-end=\"4188\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4190\" data-end=\"4216\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4218\" data-end=\"4226\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4227\" data-end=\"4241\"\u003e\u003cstrong data-start=\"4227\" data-end=\"4241\"\u003eRS 1000.R2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4243\" data-end=\"4271\"\u003ePart Number: \u003cstrong data-start=\"4256\" data-end=\"4271\"\u003eWL-212-0022\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4273\" data-end=\"4276\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"4278\" data-end=\"4297\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"4299\" data-end=\"4329\"\u003eMaximum capacity:\u003cbr data-start=\"4316\" data-end=\"4319\"\u003e\u003cstrong data-start=\"4319\" data-end=\"4329\"\u003e1000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4331\" data-end=\"4356\"\u003eMinimum load:\u003cbr data-start=\"4344\" data-end=\"4347\"\u003e\u003cstrong data-start=\"4347\" data-end=\"4356\"\u003e20 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4358\" data-end=\"4384\"\u003eReadability:\u003cbr data-start=\"4370\" data-end=\"4373\"\u003e\u003cstrong data-start=\"4373\" data-end=\"4384\"\u003e0.001 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4386\" data-end=\"4411\"\u003eTare range:\u003cbr data-start=\"4397\" data-end=\"4400\"\u003e\u003cstrong data-start=\"4400\" data-end=\"4411\"\u003e-1000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4413\" data-end=\"4416\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4418\" data-end=\"4428\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4430\" data-end=\"4465\"\u003eRepeatability (Max):\u003cbr data-start=\"4450\" data-end=\"4453\"\u003e\u003cstrong data-start=\"4453\" data-end=\"4465\"\u003e0.0015 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4467\" data-end=\"4505\"\u003eRepeatability (5% Max):\u003cbr data-start=\"4490\" data-end=\"4493\"\u003e\u003cstrong data-start=\"4493\" data-end=\"4505\"\u003e0.0005 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4507\" data-end=\"4532\"\u003eLinearity:\u003cbr data-start=\"4517\" data-end=\"4520\"\u003e\u003cstrong data-start=\"4520\" data-end=\"4532\"\u003e±0.003 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4534\" data-end=\"4569\"\u003eStabilization time:\u003cbr data-start=\"4553\" data-end=\"4556\"\u003e\u003cstrong data-start=\"4556\" data-end=\"4569\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4571\" data-end=\"4574\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4576\" data-end=\"4585\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4587\" data-end=\"4632\"\u003e\u003cstrong data-start=\"4587\" data-end=\"4632\"\u003eBacklit LCD display with information line\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4634\" data-end=\"4637\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4639\" data-end=\"4658\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4660\" data-end=\"4675\"\u003ePan dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4677\" data-end=\"4708\"\u003e\u003cstrong data-start=\"4677\" data-end=\"4708\"\u003e5 × 5 inches (128 × 128 mm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4710\" data-end=\"4719\"\u003eMaterial:\u003c\/p\u003e\n\u003cp data-start=\"4721\" data-end=\"4740\"\u003e\u003cstrong data-start=\"4721\" data-end=\"4740\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4742\" data-end=\"4745\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4747\" data-end=\"4761\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4763\" data-end=\"4788\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4790\" data-end=\"4850\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4790\" data-end=\"4805\"\u003e\n\u003cp data-start=\"4792\" data-end=\"4805\"\u003e\u003cstrong data-start=\"4792\" data-end=\"4805\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4806\" data-end=\"4817\"\u003e\n\u003cp data-start=\"4808\" data-end=\"4817\"\u003e\u003cstrong data-start=\"4808\" data-end=\"4817\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4818\" data-end=\"4829\"\u003e\n\u003cp data-start=\"4820\" data-end=\"4829\"\u003e\u003cstrong data-start=\"4820\" data-end=\"4829\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4830\" data-end=\"4850\"\u003e\n\u003cp data-start=\"4832\" data-end=\"4850\"\u003e\u003cstrong data-start=\"4832\" data-end=\"4850\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4852\" data-end=\"4855\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4857\" data-end=\"4877\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4879\" data-end=\"4904\"\u003e\u003cstrong data-start=\"4879\" data-end=\"4904\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4906\" data-end=\"4909\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"4911\" data-end=\"4933\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4935\" data-end=\"4957\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4959\" data-end=\"4974\"\u003e\u003cstrong data-start=\"4959\" data-end=\"4974\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4976\" data-end=\"4994\"\u003eRelative humidity:\u003c\/p\u003e\n\u003cp data-start=\"4996\" data-end=\"5029\"\u003e\u003cstrong data-start=\"4996\" data-end=\"5029\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5031\" data-end=\"5034\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5036\" data-end=\"5057\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5059\" data-end=\"5078\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"5080\" data-end=\"5105\"\u003e\u003cstrong data-start=\"5080\" data-end=\"5105\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5107\" data-end=\"5119\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"5121\" data-end=\"5132\"\u003e\u003cstrong data-start=\"5121\" data-end=\"5132\"\u003e8.6 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5134\" data-end=\"5150\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"5152\" data-end=\"5162\"\u003e\u003cstrong data-start=\"5152\" data-end=\"5162\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5164\" data-end=\"5167\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"5169\" data-end=\"5184\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"5186\" data-end=\"5204\"\u003e\u003cstrong data-start=\"5186\" data-end=\"5204\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5206\" data-end=\"5209\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5211\" data-end=\"5232\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5234\" data-end=\"5456\"\u003e\n\u003cli data-section-id=\"6j1aky\" data-start=\"5234\" data-end=\"5275\"\u003e\n\u003cp data-start=\"5236\" data-end=\"5275\"\u003eRadwag RS 1000.R2 Precision Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qb4yqq\" data-start=\"5276\" data-end=\"5310\"\u003e\n\u003cp data-start=\"5278\" data-end=\"5310\"\u003eStainless Steel Weighing Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kofcw1\" data-start=\"5311\" data-end=\"5328\"\u003e\n\u003cp data-start=\"5313\" data-end=\"5328\"\u003eWind Shield – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hio71s\" data-start=\"5329\" data-end=\"5347\"\u003e\n\u003cp data-start=\"5331\" data-end=\"5347\"\u003eDraft Shield – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"299y06\" data-start=\"5348\" data-end=\"5384\"\u003e\n\u003cp data-start=\"5350\" data-end=\"5384\"\u003eGrounding Foot (Spring Center) – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xyedi2\" data-start=\"5385\" data-end=\"5395\"\u003e\n\u003cp data-start=\"5387\" data-end=\"5395\"\u003eFeet – 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nfnlhe\" data-start=\"5396\" data-end=\"5415\"\u003e\n\u003cp data-start=\"5398\" data-end=\"5415\"\u003ePower Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yvpyh1\" data-start=\"5416\" data-end=\"5435\"\u003e\n\u003cp data-start=\"5418\" data-end=\"5435\"\u003ePlug Adapters – 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w7k5o8\" data-start=\"5436\" data-end=\"5456\"\u003e\n\u003cp data-start=\"5438\" data-end=\"5456\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5458\" data-end=\"5461\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5463\" data-end=\"5473\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5475\" data-end=\"5507\"\u003e\u003cstrong data-start=\"5475\" data-end=\"5507\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5509\" data-end=\"5512\"\u003e\n\u003ch1 data-section-id=\"1wnlmxt\" data-start=\"5514\" data-end=\"5525\"\u003eDownloads\u003c\/h1\u003e\n\u003cul data-start=\"5527\" data-end=\"5596\"\u003e\n\u003cli data-section-id=\"10sdtyb\" data-start=\"5527\" data-end=\"5540\"\u003e\n\u003cp data-start=\"5529\" data-end=\"5540\"\u003eUser Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pz8bpx\" data-start=\"5541\" data-end=\"5559\"\u003e\n\u003cp data-start=\"5543\" data-end=\"5559\"\u003eProduct Brochure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"oi2zwy\" data-start=\"5560\" data-end=\"5572\"\u003e\n\u003cp data-start=\"5562\" data-end=\"5572\"\u003eUSB Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18bkez1\" data-start=\"5573\" data-end=\"5596\"\u003e\n\u003cp data-start=\"5575\" data-end=\"5596\"\u003eALIBI Reader Software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282557104450,"sku":null,"price":1478.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ps-r1_ps-1000-r2--wl-212-0022-_1.jpg?v=1773588051","url":"https:\/\/summitsupplydirect.com\/products\/across-international-ps-1000-r2-radwag-1000g-capacity-0-001g-readability-5x5-precision-balance","provider":"Summit Supply Direct","version":"1.0","type":"link"}