{"product_id":"across-international-mya-5-5y-radwag-5-1g-capacity-1µg-readability-o1-microbalance","title":"Across International MYA 5.5Y Radwag 5.1g Capacity 1µg Readability Ø1\" MicroBalance","description":"\u003ch2 data-section-id=\"itikbh\" data-start=\"520\" data-end=\"596\"\u003eUltra-Precision Microbalance with ELLIPSIS Technology and 10″ Touchscreen\u003c\/h2\u003e\n\u003cp data-start=\"598\" data-end=\"943\"\u003eThe \u003cstrong data-start=\"602\" data-end=\"634\"\u003eRadwag MYA 5.5Y Microbalance\u003c\/strong\u003e is a state-of-the-art ultra-precision weighing instrument designed for laboratories requiring \u003cstrong data-start=\"729\" data-end=\"769\"\u003emicrogram-level measurement accuracy\u003c\/strong\u003e. With \u003cstrong data-start=\"776\" data-end=\"815\"\u003e1 µg readability and 5.1 g capacity\u003c\/strong\u003e, the MYA 5.5Y is ideal for pharmaceutical research, analytical chemistry, nanotechnology, and advanced scientific applications.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"1207\"\u003ePart of the \u003cstrong data-start=\"957\" data-end=\"983\"\u003eRadwag ELLIPSIS series\u003c\/strong\u003e, this microbalance features a powerful \u003cstrong data-start=\"1023\" data-end=\"1056\"\u003e10-inch touchscreen interface\u003c\/strong\u003e, advanced environmental compensation technologies, and intelligent software designed to improve measurement accuracy, traceability, and user workflow.\u003c\/p\u003e\n\u003cp data-start=\"1209\" data-end=\"1443\"\u003eInnovations such as \u003cstrong data-start=\"1229\" data-end=\"1357\"\u003eDigital Weighing Auditor, ReflexLEVEL automatic leveling system, Smart Minimum Weight monitoring, and air density correction\u003c\/strong\u003e ensure that the balance continuously verifies measurement conditions and performance.\u003c\/p\u003e\n\u003cp data-start=\"1445\" data-end=\"1632\"\u003eWith \u003cstrong data-start=\"1450\" data-end=\"1530\"\u003eadvanced connectivity including USB, Ethernet, Wi-Fi, and hotspot capability\u003c\/strong\u003e, the MYA 5.5Y integrates seamlessly into modern laboratory information systems and digital workflows.\u003c\/p\u003e\n\u003chr data-start=\"1634\" data-end=\"1637\"\u003e\n\u003ch1 data-section-id=\"jh92xq\" data-start=\"1639\" data-end=\"1689\"\u003eKey Features of the Radwag MYA 5.5Y Microbalance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"5d6a8p\" data-start=\"1691\" data-end=\"1724\"\u003eUltra-High Precision Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1725\" data-end=\"1871\"\u003eProvides \u003cstrong data-start=\"1734\" data-end=\"1782\"\u003e1 µg readability with 5.1 g maximum capacity\u003c\/strong\u003e, enabling extremely precise mass measurements for high-accuracy laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbskc8\" data-start=\"1873\" data-end=\"1901\"\u003eDigital Weighing Auditor\u003c\/h3\u003e\n\u003cp data-start=\"1902\" data-end=\"2119\"\u003eThe built-in \u003cstrong data-start=\"1915\" data-end=\"1943\"\u003eDigital Weighing Auditor\u003c\/strong\u003e continuously verifies that the balance is ready for use and compensates for \u003cstrong data-start=\"2020\" data-end=\"2049\"\u003eair buoyancy in real time\u003c\/strong\u003e. It also alerts users when inspection or calibration may be required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16mi94l\" data-start=\"2121\" data-end=\"2155\"\u003eLarge 10″ ELLIPSIS Touchscreen\u003c\/h3\u003e\n\u003cp data-start=\"2156\" data-end=\"2223\"\u003eThe advanced \u003cstrong data-start=\"2169\" data-end=\"2201\"\u003e10-inch touchscreen terminal\u003c\/strong\u003e allows users to view:\u003c\/p\u003e\n\u003cul data-start=\"2225\" data-end=\"2376\"\u003e\n\u003cli data-section-id=\"1jocsql\" data-start=\"2225\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2227\" data-end=\"2245\"\u003eMeasurement graphs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6or1s5\" data-start=\"2246\" data-end=\"2273\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2273\"\u003eProcess status indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oqmbag\" data-start=\"2274\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2276\" data-end=\"2305\"\u003eNotes and measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p00g57\" data-start=\"2306\" data-end=\"2339\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2339\"\u003eMultiple widgets and dashboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1eyo9bf\" data-start=\"2340\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2376\"\u003eUp to three screens simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17ceyjf\" data-start=\"2378\" data-end=\"2412\"\u003eReflexLEVEL Automatic Leveling\u003c\/h3\u003e\n\u003cp data-start=\"2413\" data-end=\"2537\"\u003eThe \u003cstrong data-start=\"2417\" data-end=\"2472\"\u003eReflexLEVEL system automatically levels the balance\u003c\/strong\u003e, eliminating manual leveling and improving measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"q2j805\" data-start=\"2539\" data-end=\"2577\"\u003eAmbient Light Communication System\u003c\/h3\u003e\n\u003cp data-start=\"2578\" data-end=\"2701\"\u003eAn integrated \u003cstrong data-start=\"2592\" data-end=\"2619\"\u003eambient light indicator\u003c\/strong\u003e communicates balance status, measurement results, and alerts using color signals.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rwqjgl\" data-start=\"2703\" data-end=\"2738\"\u003eSmart Minimum Weight Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"2739\" data-end=\"2869\"\u003eDisplays whether the current sample weight is \u003cstrong data-start=\"2785\" data-end=\"2832\"\u003eabove or below the minimum weight threshold\u003c\/strong\u003e, ensuring valid measurement results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1re5pow\" data-start=\"2871\" data-end=\"2901\"\u003eAdvanced User Verification\u003c\/h3\u003e\n\u003cp data-start=\"2902\" data-end=\"2939\"\u003eSupports secure authentication using:\u003c\/p\u003e\n\u003cul data-start=\"2941\" data-end=\"3052\"\u003e\n\u003cli data-section-id=\"1rs2y50\" data-start=\"2941\" data-end=\"2959\"\u003e\n\u003cp data-start=\"2943\" data-end=\"2959\"\u003ePassword login\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vu9j8l\" data-start=\"2960\" data-end=\"2973\"\u003e\n\u003cp data-start=\"2962\" data-end=\"2973\"\u003eRFID card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1swv6dr\" data-start=\"2974\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2976\" data-end=\"3001\"\u003eFingerprint recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11aaju7\" data-start=\"3002\" data-end=\"3024\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3024\"\u003eFacial recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2ssl4b\" data-start=\"3025\" data-end=\"3052\"\u003e\n\u003cp data-start=\"3027\" data-end=\"3052\"\u003eMulti-factor combinations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ah7r85\" data-start=\"3054\" data-end=\"3077\"\u003eRFID Identification\u003c\/h3\u003e\n\u003cp data-start=\"3078\" data-end=\"3103\"\u003eRFID tags can be used to:\u003c\/p\u003e\n\u003cul data-start=\"3105\" data-end=\"3204\"\u003e\n\u003cli data-section-id=\"1rv64ha\" data-start=\"3105\" data-end=\"3121\"\u003e\n\u003cp data-start=\"3107\" data-end=\"3121\"\u003eIdentify users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzd2u\" data-start=\"3122\" data-end=\"3162\"\u003e\n\u003cp data-start=\"3124\" data-end=\"3162\"\u003eTag samples or formulation ingredients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1spqsn6\" data-start=\"3163\" data-end=\"3204\"\u003e\n\u003cp data-start=\"3165\" data-end=\"3204\"\u003eTrack materials in the balance database\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"hd4mdk\" data-start=\"3206\" data-end=\"3230\"\u003eHotspot Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3231\" data-end=\"3345\"\u003eThe balance can create its own \u003cstrong data-start=\"3262\" data-end=\"3279\"\u003eWi-Fi hotspot\u003c\/strong\u003e, allowing smartphones, tablets, or computers to connect directly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzkj2r\" data-start=\"3347\" data-end=\"3361\"\u003eLive Notes\u003c\/h3\u003e\n\u003cp data-start=\"3362\" data-end=\"3455\"\u003eUsers can attach \u003cstrong data-start=\"3379\" data-end=\"3411\"\u003evoice notes or text comments\u003c\/strong\u003e to measurement series or procedure reports.\u003c\/p\u003e\n\u003ch3 data-section-id=\"48055v\" data-start=\"3457\" data-end=\"3474\"\u003eHandy Library\u003c\/h3\u003e\n\u003cp data-start=\"3475\" data-end=\"3500\"\u003eProvides quick access to:\u003c\/p\u003e\n\u003cul data-start=\"3502\" data-end=\"3609\"\u003e\n\u003cli data-section-id=\"ccgq5n\" data-start=\"3502\" data-end=\"3530\"\u003e\n\u003cp data-start=\"3504\" data-end=\"3530\"\u003eRecent measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fqz3zv\" data-start=\"3531\" data-end=\"3568\"\u003e\n\u003cp data-start=\"3533\" data-end=\"3568\"\u003eReports ready for digital signature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kzpfxy\" data-start=\"3569\" data-end=\"3609\"\u003e\n\u003cp data-start=\"3571\" data-end=\"3609\"\u003eData compliant with \u003cstrong data-start=\"3591\" data-end=\"3609\"\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"yt04p0\" data-start=\"3611\" data-end=\"3635\"\u003eTwo-Point Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3636\" data-end=\"3740\"\u003eCalibration performed at \u003cstrong data-start=\"3661\" data-end=\"3687\"\u003etwo measurement points\u003c\/strong\u003e improves precision across the entire weighing range.\u003c\/p\u003e\n\u003chr data-start=\"3742\" data-end=\"3745\"\u003e\n\u003ch1 data-section-id=\"nj2mc6\" data-start=\"3747\" data-end=\"3777\"\u003eCompliance and Data Security\u003c\/h1\u003e\n\u003cp data-start=\"3779\" data-end=\"3936\"\u003eThe MYA 5.5Y microbalance supports optional \u003cstrong data-start=\"3823\" data-end=\"3852\"\u003e21 CFR Part 11 compliance\u003c\/strong\u003e, making it suitable for regulated environments such as pharmaceutical laboratories.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ea5lk6\" data-start=\"3938\" data-end=\"3968\"\u003eCompliance Module Features\u003c\/h3\u003e\n\u003cul data-start=\"3970\" data-end=\"4135\"\u003e\n\u003cli data-section-id=\"4lnuvx\" data-start=\"3970\" data-end=\"3993\"\u003e\n\u003cp data-start=\"3972\" data-end=\"3993\"\u003eElectronic signatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fbl7wq\" data-start=\"3994\" data-end=\"4024\"\u003e\n\u003cp data-start=\"3996\" data-end=\"4024\"\u003eAdvanced password protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nl5kvf\" data-start=\"4025\" data-end=\"4054\"\u003e\n\u003cp data-start=\"4027\" data-end=\"4054\"\u003eControlled user permissions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s01jpb\" data-start=\"4055\" data-end=\"4073\"\u003e\n\u003cp data-start=\"4057\" data-end=\"4073\"\u003eAutomatic logout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jm4kdm\" data-start=\"4074\" data-end=\"4097\"\u003e\n\u003cp data-start=\"4076\" data-end=\"4097\"\u003eAudit Trail recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16qwjei\" data-start=\"4098\" data-end=\"4135\"\u003e\n\u003cp data-start=\"4100\" data-end=\"4135\"\u003eBackup and data management controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4137\" data-end=\"4207\"\u003eThe \u003cstrong data-start=\"4141\" data-end=\"4195\"\u003eAudit Trail system records every data modification\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"4209\" data-end=\"4281\"\u003e\n\u003cli data-section-id=\"cehz8i\" data-start=\"4209\" data-end=\"4224\"\u003e\n\u003cp data-start=\"4211\" data-end=\"4224\"\u003eDate and time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hf6dju\" data-start=\"4225\" data-end=\"4241\"\u003e\n\u003cp data-start=\"4227\" data-end=\"4241\"\u003eOriginal value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jhndj6\" data-start=\"4242\" data-end=\"4258\"\u003e\n\u003cp data-start=\"4244\" data-end=\"4258\"\u003eModified value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2d2bik\" data-start=\"4259\" data-end=\"4281\"\u003e\n\u003cp data-start=\"4261\" data-end=\"4281\"\u003eResponsible operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4283\" data-end=\"4348\"\u003eAudit data can be exported in \u003cstrong data-start=\"4313\" data-end=\"4347\"\u003ePDF, XLS, CSV, or HTML formats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4350\" data-end=\"4353\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"4355\" data-end=\"4384\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"4386\" data-end=\"4472\"\u003eThe MYA 5.5Y microbalance includes a comprehensive set of professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"4474\" data-end=\"4486\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"4487\" data-end=\"4566\"\u003eAutomatic diagnostics evaluate repeatability and optimize weighing performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"4568\" data-end=\"4578\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"4579\" data-end=\"4679\"\u003eAllows controlled weighing of powders, liquids, or granular materials with defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4681\" data-end=\"4701\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4702\" data-end=\"4768\"\u003eDisplays sample mass as a percentage relative to a reference mass.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4770\" data-end=\"4788\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4789\" data-end=\"4876\"\u003eDetermines item quantity based on known unit weight with automatic accuracy correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nnh1is\" data-start=\"4878\" data-end=\"4893\"\u003eFormulation\u003c\/h3\u003e\n\u003cp data-start=\"4894\" data-end=\"4965\"\u003eSupports multi-component mixture preparation with tolerance monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1agpw9b\" data-start=\"4967\" data-end=\"4991\"\u003eStatistical Analysis\u003c\/h3\u003e\n\u003cp data-start=\"4992\" data-end=\"5028\"\u003eProvides statistical data including:\u003c\/p\u003e\n\u003cul data-start=\"5030\" data-end=\"5126\"\u003e\n\u003cli data-section-id=\"1tpje4l\" data-start=\"5030\" data-end=\"5058\"\u003e\n\u003cp data-start=\"5032\" data-end=\"5058\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s9zm9s\" data-start=\"5059\" data-end=\"5074\"\u003e\n\u003cp data-start=\"5061\" data-end=\"5074\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvyhm8\" data-start=\"5075\" data-end=\"5095\"\u003e\n\u003cp data-start=\"5077\" data-end=\"5095\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwk9jh\" data-start=\"5096\" data-end=\"5106\"\u003e\n\u003cp data-start=\"5098\" data-end=\"5106\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xk4t9\" data-start=\"5107\" data-end=\"5126\"\u003e\n\u003cp data-start=\"5109\" data-end=\"5126\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"a1clir\" data-start=\"5128\" data-end=\"5153\"\u003eDifferential Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5154\" data-end=\"5221\"\u003eDetermines mass variation during manufacturing or processing steps.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ly0npz\" data-start=\"5223\" data-end=\"5254\"\u003eStatistical Quality Control\u003c\/h3\u003e\n\u003cp data-start=\"5255\" data-end=\"5321\"\u003eMonitors production batches with automated statistical evaluation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"5323\" data-end=\"5340\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"5341\" data-end=\"5403\"\u003eIndicates whether a sample falls within defined weight limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"5405\" data-end=\"5424\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5425\" data-end=\"5478\"\u003eAllows accurate mass determination of moving samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nmwv3m\" data-start=\"5480\" data-end=\"5506\"\u003eAir Density Correction\u003c\/h3\u003e\n\u003cp data-start=\"5507\" data-end=\"5580\"\u003eCorrects measurement results by accounting for environmental air density.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1b1e0do\" data-start=\"5582\" data-end=\"5603\"\u003eIR Sensor Control\u003c\/h3\u003e\n\u003cp data-start=\"5604\" data-end=\"5658\"\u003eTouch-free infrared sensors enable operations such as:\u003c\/p\u003e\n\u003cul data-start=\"5660\" data-end=\"5713\"\u003e\n\u003cli data-section-id=\"18leszv\" data-start=\"5660\" data-end=\"5683\"\u003e\n\u003cp data-start=\"5662\" data-end=\"5683\"\u003eOpening chamber doors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q29ch6\" data-start=\"5684\" data-end=\"5693\"\u003e\n\u003cp data-start=\"5686\" data-end=\"5693\"\u003eZeroing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5ro1vz\" data-start=\"5694\" data-end=\"5702\"\u003e\n\u003cp data-start=\"5696\" data-end=\"5702\"\u003eTaring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1goa1q1\" data-start=\"5703\" data-end=\"5713\"\u003e\n\u003cp data-start=\"5705\" data-end=\"5713\"\u003ePrinting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"5715\" data-end=\"5732\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"5733\" data-end=\"5785\"\u003eSupports \u003cstrong data-start=\"5742\" data-end=\"5784\"\u003eGood Laboratory Practice documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5787\" data-end=\"5790\"\u003e\n\u003ch1 data-section-id=\"ggdxdk\" data-start=\"5792\" data-end=\"5811\"\u003eALIBI Data Memory\u003c\/h1\u003e\n\u003cp data-start=\"5813\" data-end=\"5905\"\u003eThe integrated \u003cstrong data-start=\"5828\" data-end=\"5893\"\u003eALIBI memory automatically records up to 100,000 measurements\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"5907\" data-end=\"6005\"\u003e\n\u003cli data-section-id=\"1obhcxi\" data-start=\"5907\" data-end=\"5925\"\u003e\n\u003cp data-start=\"5909\" data-end=\"5925\"\u003eMeasurement date\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j4crzx\" data-start=\"5926\" data-end=\"5932\"\u003e\n\u003cp data-start=\"5928\" data-end=\"5932\"\u003eTime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ie1rkd\" data-start=\"5933\" data-end=\"5946\"\u003e\n\u003cp data-start=\"5935\" data-end=\"5946\"\u003eMass result\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14lfw5d\" data-start=\"5947\" data-end=\"5959\"\u003e\n\u003cp data-start=\"5949\" data-end=\"5959\"\u003eTare value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a2rsbk\" data-start=\"5960\" data-end=\"5980\"\u003e\n\u003cp data-start=\"5962\" data-end=\"5980\"\u003eLogged-in operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y91o3t\" data-start=\"5981\" data-end=\"6005\"\u003e\n\u003cp data-start=\"5983\" data-end=\"6005\"\u003eProduct identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6007\" data-end=\"6093\"\u003eStored measurements cannot be manually deleted, ensuring \u003cstrong data-start=\"6064\" data-end=\"6092\"\u003esecure data traceability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"6095\" data-end=\"6098\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"6100\" data-end=\"6120\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"6122\" data-end=\"6175\"\u003eThe Radwag MYA 5.5Y microbalance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"6177\" data-end=\"6380\"\u003e\n\u003cli data-section-id=\"1hipxyr\" data-start=\"6177\" data-end=\"6217\"\u003e\n\u003cp data-start=\"6179\" data-end=\"6217\"\u003ePharmaceutical research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ktawpv\" data-start=\"6218\" data-end=\"6255\"\u003e\n\u003cp data-start=\"6220\" data-end=\"6255\"\u003eAnalytical chemistry laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"126lv89\" data-start=\"6256\" data-end=\"6283\"\u003e\n\u003cp data-start=\"6258\" data-end=\"6283\"\u003eNanotechnology research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6eze3\" data-start=\"6284\" data-end=\"6309\"\u003e\n\u003cp data-start=\"6286\" data-end=\"6309\"\u003eMicro-sample analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"6310\" data-end=\"6342\"\u003e\n\u003cp data-start=\"6312\" data-end=\"6342\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xykno0\" data-start=\"6343\" data-end=\"6380\"\u003e\n\u003cp data-start=\"6345\" data-end=\"6380\"\u003eBiotechnology research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6382\" data-end=\"6385\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"6387\" data-end=\"6413\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"6415\" data-end=\"6423\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"6424\" data-end=\"6436\"\u003e\u003cstrong data-start=\"6424\" data-end=\"6436\"\u003eMYA 5.5Y\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6438\" data-end=\"6466\"\u003ePart Number: \u003cstrong data-start=\"6451\" data-end=\"6466\"\u003eWL-109-0006\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6468\" data-end=\"6471\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"6473\" data-end=\"6495\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"6497\" data-end=\"6525\"\u003eMaximum capacity\u003cbr data-start=\"6513\" data-end=\"6516\"\u003e\u003cstrong data-start=\"6516\" data-end=\"6525\"\u003e5.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6527\" data-end=\"6552\"\u003eMinimum load\u003cbr data-start=\"6539\" data-end=\"6542\"\u003e\u003cstrong data-start=\"6542\" data-end=\"6552\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6554\" data-end=\"6576\"\u003eReadability\u003cbr data-start=\"6565\" data-end=\"6568\"\u003e\u003cstrong data-start=\"6568\" data-end=\"6576\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6578\" data-end=\"6601\"\u003eTare range\u003cbr data-start=\"6588\" data-end=\"6591\"\u003e\u003cstrong data-start=\"6591\" data-end=\"6601\"\u003e−5.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6603\" data-end=\"6606\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"6608\" data-end=\"6618\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"6620\" data-end=\"6655\"\u003eRepeatability (5% Max)\u003cbr data-start=\"6642\" data-end=\"6645\"\u003e\u003cstrong data-start=\"6645\" data-end=\"6655\"\u003e0.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6657\" data-end=\"6689\"\u003eRepeatability (Max)\u003cbr data-start=\"6676\" data-end=\"6679\"\u003e\u003cstrong data-start=\"6679\" data-end=\"6689\"\u003e1.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6691\" data-end=\"6738\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"6725\" data-end=\"6728\"\u003e\u003cstrong data-start=\"6728\" data-end=\"6738\"\u003e1.2 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6740\" data-end=\"6784\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6771\" data-end=\"6774\"\u003e\u003cstrong data-start=\"6774\" data-end=\"6784\"\u003e2.4 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6786\" data-end=\"6807\"\u003eLinearity\u003cbr data-start=\"6795\" data-end=\"6798\"\u003e\u003cstrong data-start=\"6798\" data-end=\"6807\"\u003e±5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6809\" data-end=\"6851\"\u003eStabilization time\u003cbr data-start=\"6827\" data-end=\"6830\"\u003e\u003cstrong data-start=\"6830\" data-end=\"6851\"\u003eMaximum 8 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6853\" data-end=\"6856\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6858\" data-end=\"6881\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6883\" data-end=\"6914\"\u003eUSP minimum weight\u003cbr data-start=\"6901\" data-end=\"6904\"\u003e\u003cstrong data-start=\"6904\" data-end=\"6914\"\u003e1.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6916\" data-end=\"6960\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"6946\" data-end=\"6949\"\u003e\u003cstrong data-start=\"6949\" data-end=\"6960\"\u003e0.12 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6962\" data-end=\"6965\"\u003e\n\u003ch1 data-section-id=\"1mcqff0\" data-start=\"6967\" data-end=\"6980\"\u003eCalibration\u003c\/h1\u003e\n\u003cp data-start=\"6982\" data-end=\"7015\"\u003e\u003cstrong data-start=\"6982\" data-end=\"7015\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7017\" data-end=\"7020\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"7022\" data-end=\"7043\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"7045\" data-end=\"7056\"\u003e\u003cstrong data-start=\"7045\" data-end=\"7056\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7058\" data-end=\"7061\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"7063\" data-end=\"7072\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"7074\" data-end=\"7117\"\u003e\u003cstrong data-start=\"7074\" data-end=\"7117\"\u003e10-inch touchscreen (ELLIPSIS terminal)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7119\" data-end=\"7122\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"7124\" data-end=\"7138\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"7140\" data-end=\"7173\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"7175\" data-end=\"7266\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"7175\" data-end=\"7189\"\u003e\n\u003cp data-start=\"7177\" data-end=\"7189\"\u003e\u003cstrong data-start=\"7177\" data-end=\"7189\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"7190\" data-end=\"7201\"\u003e\n\u003cp data-start=\"7192\" data-end=\"7201\"\u003e\u003cstrong data-start=\"7192\" data-end=\"7201\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"7202\" data-end=\"7212\"\u003e\n\u003cp data-start=\"7204\" data-end=\"7212\"\u003e\u003cstrong data-start=\"7204\" data-end=\"7212\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"7213\" data-end=\"7227\"\u003e\n\u003cp data-start=\"7215\" data-end=\"7227\"\u003e\u003cstrong data-start=\"7215\" data-end=\"7227\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"7228\" data-end=\"7239\"\u003e\n\u003cp data-start=\"7230\" data-end=\"7239\"\u003e\u003cstrong data-start=\"7230\" data-end=\"7239\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"7240\" data-end=\"7266\"\u003e\n\u003cp data-start=\"7242\" data-end=\"7266\"\u003e\u003cstrong data-start=\"7242\" data-end=\"7266\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7268\" data-end=\"7271\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"7273\" data-end=\"7295\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"7297\" data-end=\"7336\"\u003eOperating temperature\u003cbr data-start=\"7318\" data-end=\"7321\"\u003e\u003cstrong data-start=\"7321\" data-end=\"7336\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7338\" data-end=\"7393\"\u003eTemperature stability requirement\u003cbr data-start=\"7371\" data-end=\"7374\"\u003e\u003cstrong data-start=\"7374\" data-end=\"7393\"\u003e±0.3°C per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7395\" data-end=\"7428\"\u003eRelative humidity\u003cbr data-start=\"7412\" data-end=\"7415\"\u003e\u003cstrong data-start=\"7415\" data-end=\"7428\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7430\" data-end=\"7469\"\u003eHumidity change rate\u003cbr data-start=\"7450\" data-end=\"7453\"\u003e\u003cstrong data-start=\"7453\" data-end=\"7469\"\u003e±1% per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7471\" data-end=\"7474\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"7476\" data-end=\"7494\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"7496\" data-end=\"7520\"\u003ePan diameter\u003cbr data-start=\"7508\" data-end=\"7511\"\u003e\u003cstrong data-start=\"7511\" data-end=\"7520\"\u003e26 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7522\" data-end=\"7557\"\u003eChamber dimensions\u003cbr data-start=\"7540\" data-end=\"7543\"\u003e\u003cstrong data-start=\"7543\" data-end=\"7557\"\u003e90 × 90 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7559\" data-end=\"7562\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"7564\" data-end=\"7585\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"7587\" data-end=\"7630\"\u003ePackage dimensions\u003cbr data-start=\"7605\" data-end=\"7608\"\u003e\u003cstrong data-start=\"7608\" data-end=\"7630\"\u003e655 × 755 × 445 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7632\" data-end=\"7656\"\u003eUnit weight\u003cbr data-start=\"7643\" data-end=\"7646\"\u003e\u003cstrong data-start=\"7646\" data-end=\"7656\"\u003e45 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7658\" data-end=\"7686\"\u003eShipping weight\u003cbr data-start=\"7673\" data-end=\"7676\"\u003e\u003cstrong data-start=\"7676\" data-end=\"7686\"\u003e75 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7688\" data-end=\"7691\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"7693\" data-end=\"7713\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"7715\" data-end=\"7750\"\u003eAdapter\u003cbr data-start=\"7722\" data-end=\"7725\"\u003e\u003cstrong data-start=\"7725\" data-end=\"7750\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7752\" data-end=\"7781\"\u003eBalance input\u003cbr data-start=\"7765\" data-end=\"7768\"\u003e\u003cstrong data-start=\"7768\" data-end=\"7781\"\u003e12–15V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7783\" data-end=\"7786\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7788\" data-end=\"7798\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7800\" data-end=\"7832\"\u003e\u003cstrong data-start=\"7800\" data-end=\"7832\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282613367106,"sku":null,"price":24961.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/MYA_5.5Y__WL-109-0006_-removebg-preview.png?v=1773590093","url":"https:\/\/summitsupplydirect.com\/products\/across-international-mya-5-5y-radwag-5-1g-capacity-1%c2%b5g-readability-o1-microbalance","provider":"Summit Supply Direct","version":"1.0","type":"link"}