{"product_id":"across-international-mya-2-5y-radwag-2-1-g-capacity-0-1-µg-readability-o16-mm-microbalance","title":"Across International MYA 2.5Y Radwag 2.1 g Capacity 0.1 µg Readability ø16 mm Microbalance","description":"\u003ch2 data-section-id=\"15o89qi\" data-start=\"373\" data-end=\"460\"\u003eUltra-High Precision Microbalance with 10″ Touchscreen and ELLIPSIS Smart Technology\u003c\/h2\u003e\n\u003cp data-start=\"462\" data-end=\"838\"\u003eThe \u003cstrong data-start=\"466\" data-end=\"498\"\u003eRadwag MYA 2.5Y Microbalance\u003c\/strong\u003e is an ultra-precision laboratory balance designed for applications requiring \u003cstrong data-start=\"576\" data-end=\"604\"\u003emicrogram-level accuracy\u003c\/strong\u003e. With \u003cstrong data-start=\"611\" data-end=\"650\"\u003e1 µg readability and 2.1 g capacity\u003c\/strong\u003e, the MYA 2.5Y is ideal for high-precision research environments including pharmaceutical laboratories, analytical chemistry labs, nanotechnology research, and advanced scientific testing.\u003c\/p\u003e\n\u003cp data-start=\"840\" data-end=\"1146\"\u003ePart of the \u003cstrong data-start=\"852\" data-end=\"878\"\u003eRadwag ELLIPSIS series\u003c\/strong\u003e, this microbalance integrates innovative smart technologies including a \u003cstrong data-start=\"951\" data-end=\"1079\"\u003eDigital Weighing Auditor, ReflexLEVEL automatic leveling system, Smart Minimum Weight monitoring, and air density correction\u003c\/strong\u003e to ensure optimal weighing conditions and measurement reliability.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1401\"\u003eThe balance features an advanced \u003cstrong data-start=\"1181\" data-end=\"1213\"\u003e10-inch touchscreen terminal\u003c\/strong\u003e, intuitive user interface, and powerful connectivity options such as \u003cstrong data-start=\"1283\" data-end=\"1333\"\u003eUSB, Ethernet, Wi-Fi, and hotspot connectivity\u003c\/strong\u003e, enabling seamless integration with modern laboratory data systems.\u003c\/p\u003e\n\u003chr data-start=\"1403\" data-end=\"1406\"\u003e\n\u003ch1 data-section-id=\"1wfr49l\" data-start=\"1408\" data-end=\"1458\"\u003eKey Features of the Radwag MYA 2.5Y Microbalance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"8qg2xb\" data-start=\"1460\" data-end=\"1500\"\u003eUltra-Precision Weighing Performance\u003c\/h3\u003e\n\u003cp data-start=\"1501\" data-end=\"1646\"\u003eProvides \u003cstrong data-start=\"1510\" data-end=\"1558\"\u003e1 µg readability with 2.1 g maximum capacity\u003c\/strong\u003e, enabling extremely precise mass determination for micro-scale laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbskc8\" data-start=\"1648\" data-end=\"1676\"\u003eDigital Weighing Auditor\u003c\/h3\u003e\n\u003cp data-start=\"1677\" data-end=\"1900\"\u003eThe integrated \u003cstrong data-start=\"1692\" data-end=\"1720\"\u003eDigital Weighing Auditor\u003c\/strong\u003e continuously monitors the balance’s readiness and compensates for \u003cstrong data-start=\"1787\" data-end=\"1816\"\u003eair buoyancy in real time\u003c\/strong\u003e. It also alerts users when balance inspection or accuracy verification is required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iecdcq\" data-start=\"1902\" data-end=\"1934\"\u003e10-Inch ELLIPSIS Touchscreen\u003c\/h3\u003e\n\u003cp data-start=\"1935\" data-end=\"1997\"\u003eThe large \u003cstrong data-start=\"1945\" data-end=\"1972\"\u003e10″ touchscreen display\u003c\/strong\u003e allows users to monitor:\u003c\/p\u003e\n\u003cul data-start=\"1999\" data-end=\"2148\"\u003e\n\u003cli data-section-id=\"jmr6pt\" data-start=\"1999\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2001\" data-end=\"2046\"\u003eMultiple measurement screens simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3iyw9g\" data-start=\"2047\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2081\"\u003eGraphs and measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ud9594\" data-start=\"2082\" data-end=\"2114\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2114\"\u003eStatus indicators and alerts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i7jsoo\" data-start=\"2115\" data-end=\"2148\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2148\"\u003eCustom widgets and dashboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"mm5au6\" data-start=\"2150\" data-end=\"2191\"\u003eReflexLEVEL Automatic Leveling System\u003c\/h3\u003e\n\u003cp data-start=\"2192\" data-end=\"2320\"\u003eThe \u003cstrong data-start=\"2196\" data-end=\"2251\"\u003eReflexLEVEL system automatically levels the balance\u003c\/strong\u003e, eliminating manual adjustments and improving measurement precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1k202xs\" data-start=\"2322\" data-end=\"2353\"\u003eAmbient Light Communication\u003c\/h3\u003e\n\u003cp data-start=\"2354\" data-end=\"2495\"\u003eIntegrated ambient lighting communicates balance status through color signals indicating process results, alerts, and measurement conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14xsojt\" data-start=\"2497\" data-end=\"2529\"\u003eAdvanced User Authentication\u003c\/h3\u003e\n\u003cp data-start=\"2530\" data-end=\"2570\"\u003eSupports secure user identification via:\u003c\/p\u003e\n\u003cul data-start=\"2572\" data-end=\"2701\"\u003e\n\u003cli data-section-id=\"1rs2y50\" data-start=\"2572\" data-end=\"2590\"\u003e\n\u003cp data-start=\"2574\" data-end=\"2590\"\u003ePassword login\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10s7sja\" data-start=\"2591\" data-end=\"2605\"\u003e\n\u003cp data-start=\"2593\" data-end=\"2605\"\u003eRFID cards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1swv6dr\" data-start=\"2606\" data-end=\"2633\"\u003e\n\u003cp data-start=\"2608\" data-end=\"2633\"\u003eFingerprint recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11aaju7\" data-start=\"2634\" data-end=\"2656\"\u003e\n\u003cp data-start=\"2636\" data-end=\"2656\"\u003eFacial recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1eacdkb\" data-start=\"2657\" data-end=\"2701\"\u003e\n\u003cp data-start=\"2659\" data-end=\"2701\"\u003eMulti-factor authentication combinations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hdcg1t\" data-start=\"2703\" data-end=\"2723\"\u003eRFID Integration\u003c\/h3\u003e\n\u003cp data-start=\"2724\" data-end=\"2766\"\u003eRFID technology enables identification of:\u003c\/p\u003e\n\u003cul data-start=\"2768\" data-end=\"2817\"\u003e\n\u003cli data-section-id=\"15qgrd6\" data-start=\"2768\" data-end=\"2777\"\u003e\n\u003cp data-start=\"2770\" data-end=\"2777\"\u003eUsers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lt94cd\" data-start=\"2778\" data-end=\"2789\"\u003e\n\u003cp data-start=\"2780\" data-end=\"2789\"\u003eSamples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pd5uek\" data-start=\"2790\" data-end=\"2817\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2817\"\u003eFormulation ingredients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2819\" data-end=\"2899\"\u003eRFID tags can be linked to balance databases for improved workflow traceability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hd4mdk\" data-start=\"2901\" data-end=\"2925\"\u003eHotspot Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2926\" data-end=\"3043\"\u003eThe balance can create its own \u003cstrong data-start=\"2957\" data-end=\"2977\"\u003ewireless hotspot\u003c\/strong\u003e, allowing smartphones, tablets, or computers to connect directly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzkj2r\" data-start=\"3045\" data-end=\"3059\"\u003eLive Notes\u003c\/h3\u003e\n\u003cp data-start=\"3060\" data-end=\"3150\"\u003eUsers can attach \u003cstrong data-start=\"3077\" data-end=\"3106\"\u003evoice memos or text notes\u003c\/strong\u003e to measurement series or procedure reports.\u003c\/p\u003e\n\u003ch3 data-section-id=\"48055v\" data-start=\"3152\" data-end=\"3169\"\u003eHandy Library\u003c\/h3\u003e\n\u003cp data-start=\"3170\" data-end=\"3177\"\u003eStores:\u003c\/p\u003e\n\u003cul data-start=\"3179\" data-end=\"3299\"\u003e\n\u003cli data-section-id=\"7isb2v\" data-start=\"3179\" data-end=\"3209\"\u003e\n\u003cp data-start=\"3181\" data-end=\"3209\"\u003eRecent measurement records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wjyol7\" data-start=\"3210\" data-end=\"3249\"\u003e\n\u003cp data-start=\"3212\" data-end=\"3249\"\u003eReports ready for digital signature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"55fpuc\" data-start=\"3250\" data-end=\"3299\"\u003e\n\u003cp data-start=\"3252\" data-end=\"3299\"\u003eDocumentation compliant with \u003cstrong data-start=\"3281\" data-end=\"3299\"\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rwqjgl\" data-start=\"3301\" data-end=\"3336\"\u003eSmart Minimum Weight Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"3337\" data-end=\"3446\"\u003eDisplays whether the sample weight is above the required \u003cstrong data-start=\"3394\" data-end=\"3422\"\u003eminimum weight threshold\u003c\/strong\u003e for valid measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yt04p0\" data-start=\"3448\" data-end=\"3472\"\u003eTwo-Point Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3473\" data-end=\"3578\"\u003eCalibration at \u003cstrong data-start=\"3488\" data-end=\"3514\"\u003etwo measurement points\u003c\/strong\u003e improves measurement accuracy across the entire weighing range.\u003c\/p\u003e\n\u003chr data-start=\"3580\" data-end=\"3583\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3585\" data-end=\"3614\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"3616\" data-end=\"3695\"\u003eThe MYA 2.5Y microbalance supports a wide range of professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"3697\" data-end=\"3709\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"3710\" data-end=\"3789\"\u003eAutomatic diagnostic function evaluating balance repeatability and performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"3791\" data-end=\"3801\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"3802\" data-end=\"3862\"\u003ePrecise dosing based on reference mass and tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"3864\" data-end=\"3884\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3885\" data-end=\"3954\"\u003eDisplays sample weight as a percentage relative to a reference value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3956\" data-end=\"3974\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3975\" data-end=\"4058\"\u003eDetermines item quantity based on individual unit weight with automatic correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nnh1is\" data-start=\"4060\" data-end=\"4075\"\u003eFormulation\u003c\/h3\u003e\n\u003cp data-start=\"4076\" data-end=\"4149\"\u003eSupports multi-component formulation processes with tolerance monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1agpw9b\" data-start=\"4151\" data-end=\"4175\"\u003eStatistical Analysis\u003c\/h3\u003e\n\u003cp data-start=\"4176\" data-end=\"4212\"\u003eProvides statistical data including:\u003c\/p\u003e\n\u003cul data-start=\"4214\" data-end=\"4320\"\u003e\n\u003cli data-section-id=\"1s8fw79\" data-start=\"4214\" data-end=\"4244\"\u003e\n\u003cp data-start=\"4216\" data-end=\"4244\"\u003eMinimum and maximum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"4245\" data-end=\"4262\"\u003e\n\u003cp data-start=\"4247\" data-end=\"4262\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"4263\" data-end=\"4285\"\u003e\n\u003cp data-start=\"4265\" data-end=\"4285\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"4286\" data-end=\"4298\"\u003e\n\u003cp data-start=\"4288\" data-end=\"4298\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"4299\" data-end=\"4320\"\u003e\n\u003cp data-start=\"4301\" data-end=\"4320\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"a1clir\" data-start=\"4322\" data-end=\"4347\"\u003eDifferential Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4348\" data-end=\"4415\"\u003eMeasures mass variation during manufacturing or research processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ly0npz\" data-start=\"4417\" data-end=\"4448\"\u003eStatistical Quality Control\u003c\/h3\u003e\n\u003cp data-start=\"4449\" data-end=\"4510\"\u003eProvides statistical batch control for production monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4512\" data-end=\"4529\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4530\" data-end=\"4600\"\u003eIndicates whether sample weight falls within defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1b1e0do\" data-start=\"4602\" data-end=\"4623\"\u003eIR Sensor Control\u003c\/h3\u003e\n\u003cp data-start=\"4624\" data-end=\"4712\"\u003eTouch-free infrared sensors allow users to operate the balance without physical contact.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"4714\" data-end=\"4731\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"4732\" data-end=\"4784\"\u003eSupports \u003cstrong data-start=\"4741\" data-end=\"4783\"\u003eGood Laboratory Practice documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4786\" data-end=\"4789\"\u003e\n\u003ch1 data-section-id=\"ggdxdk\" data-start=\"4791\" data-end=\"4810\"\u003eALIBI Data Memory\u003c\/h1\u003e\n\u003cp data-start=\"4812\" data-end=\"4911\"\u003eThe integrated \u003cstrong data-start=\"4827\" data-end=\"4899\"\u003eALIBI memory system automatically records up to 100,000 measurements\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"4913\" data-end=\"5021\"\u003e\n\u003cli data-section-id=\"fxyqbs\" data-start=\"4913\" data-end=\"4942\"\u003e\n\u003cp data-start=\"4915\" data-end=\"4942\"\u003eMeasurement date and time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l91jg3\" data-start=\"4943\" data-end=\"4966\"\u003e\n\u003cp data-start=\"4945\" data-end=\"4966\"\u003eMeasured mass value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rdpcox\" data-start=\"4967\" data-end=\"4981\"\u003e\n\u003cp data-start=\"4969\" data-end=\"4981\"\u003eTare value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z378kg\" data-start=\"4982\" data-end=\"5004\"\u003e\n\u003cp data-start=\"4984\" data-end=\"5004\"\u003eLogged-in operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h4tn38\" data-start=\"5005\" data-end=\"5021\"\u003e\n\u003cp data-start=\"5007\" data-end=\"5021\"\u003eProduct name\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5023\" data-end=\"5100\"\u003eStored measurements cannot be manually deleted, ensuring secure traceability.\u003c\/p\u003e\n\u003chr data-start=\"5102\" data-end=\"5105\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5107\" data-end=\"5127\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5129\" data-end=\"5182\"\u003eThe Radwag MYA 2.5Y microbalance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5184\" data-end=\"5401\"\u003e\n\u003cli data-section-id=\"1hipxyr\" data-start=\"5184\" data-end=\"5224\"\u003e\n\u003cp data-start=\"5186\" data-end=\"5224\"\u003ePharmaceutical research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qm6p7e\" data-start=\"5225\" data-end=\"5254\"\u003e\n\u003cp data-start=\"5227\" data-end=\"5254\"\u003eAnalytical chemistry labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"muciv2\" data-start=\"5255\" data-end=\"5304\"\u003e\n\u003cp data-start=\"5257\" data-end=\"5304\"\u003eNanotechnology and materials science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cac3vx\" data-start=\"5305\" data-end=\"5330\"\u003e\n\u003cp data-start=\"5307\" data-end=\"5330\"\u003eMicro-sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xykno0\" data-start=\"5331\" data-end=\"5368\"\u003e\n\u003cp data-start=\"5333\" data-end=\"5368\"\u003eBiotechnology research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5369\" data-end=\"5401\"\u003e\n\u003cp data-start=\"5371\" data-end=\"5401\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5403\" data-end=\"5406\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5408\" data-end=\"5434\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5436\" data-end=\"5444\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5445\" data-end=\"5457\"\u003e\u003cstrong data-start=\"5445\" data-end=\"5457\"\u003eMYA 2.5Y\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5459\" data-end=\"5487\"\u003ePart Number: \u003cstrong data-start=\"5472\" data-end=\"5487\"\u003eWL-109-0004\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5489\" data-end=\"5492\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5494\" data-end=\"5516\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5518\" data-end=\"5546\"\u003eMaximum capacity\u003cbr data-start=\"5534\" data-end=\"5537\"\u003e\u003cstrong data-start=\"5537\" data-end=\"5546\"\u003e2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5548\" data-end=\"5573\"\u003eMinimum load\u003cbr data-start=\"5560\" data-end=\"5563\"\u003e\u003cstrong data-start=\"5563\" data-end=\"5573\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5575\" data-end=\"5597\"\u003eReadability\u003cbr data-start=\"5586\" data-end=\"5589\"\u003e\u003cstrong data-start=\"5589\" data-end=\"5597\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5599\" data-end=\"5622\"\u003eTare range\u003cbr data-start=\"5609\" data-end=\"5612\"\u003e\u003cstrong data-start=\"5612\" data-end=\"5622\"\u003e−2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5624\" data-end=\"5627\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5629\" data-end=\"5639\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5641\" data-end=\"5677\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5663\" data-end=\"5666\"\u003e\u003cstrong data-start=\"5666\" data-end=\"5677\"\u003e0.41 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5679\" data-end=\"5709\"\u003eRepeatability (Max)\u003cbr data-start=\"5698\" data-end=\"5701\"\u003e\u003cstrong data-start=\"5701\" data-end=\"5709\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5711\" data-end=\"5758\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"5745\" data-end=\"5748\"\u003e\u003cstrong data-start=\"5748\" data-end=\"5758\"\u003e0.8 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5760\" data-end=\"5804\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"5791\" data-end=\"5794\"\u003e\u003cstrong data-start=\"5794\" data-end=\"5804\"\u003e1.5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5806\" data-end=\"5827\"\u003eLinearity\u003cbr data-start=\"5815\" data-end=\"5818\"\u003e\u003cstrong data-start=\"5818\" data-end=\"5827\"\u003e±3 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5829\" data-end=\"5871\"\u003eStabilization time\u003cbr data-start=\"5847\" data-end=\"5850\"\u003e\u003cstrong data-start=\"5850\" data-end=\"5871\"\u003eMaximum 8 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5873\" data-end=\"5876\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"5878\" data-end=\"5901\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"5903\" data-end=\"5935\"\u003eUSP minimum weight\u003cbr data-start=\"5921\" data-end=\"5924\"\u003e\u003cstrong data-start=\"5924\" data-end=\"5935\"\u003e0.82 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5937\" data-end=\"5982\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"5967\" data-end=\"5970\"\u003e\u003cstrong data-start=\"5970\" data-end=\"5982\"\u003e0.082 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5984\" data-end=\"5987\"\u003e\n\u003ch1 data-section-id=\"1mcqff0\" data-start=\"5989\" data-end=\"6002\"\u003eCalibration\u003c\/h1\u003e\n\u003cp data-start=\"6004\" data-end=\"6037\"\u003e\u003cstrong data-start=\"6004\" data-end=\"6037\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6039\" data-end=\"6042\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"6044\" data-end=\"6065\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"6067\" data-end=\"6078\"\u003e\u003cstrong data-start=\"6067\" data-end=\"6078\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6080\" data-end=\"6083\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6085\" data-end=\"6094\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6096\" data-end=\"6139\"\u003e\u003cstrong data-start=\"6096\" data-end=\"6139\"\u003e10-inch touchscreen (ELLIPSIS terminal)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6141\" data-end=\"6144\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6146\" data-end=\"6160\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6162\" data-end=\"6195\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"6197\" data-end=\"6288\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"6197\" data-end=\"6211\"\u003e\n\u003cp data-start=\"6199\" data-end=\"6211\"\u003e\u003cstrong data-start=\"6199\" data-end=\"6211\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"6212\" data-end=\"6223\"\u003e\n\u003cp data-start=\"6214\" data-end=\"6223\"\u003e\u003cstrong data-start=\"6214\" data-end=\"6223\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"6224\" data-end=\"6234\"\u003e\n\u003cp data-start=\"6226\" data-end=\"6234\"\u003e\u003cstrong data-start=\"6226\" data-end=\"6234\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"6235\" data-end=\"6249\"\u003e\n\u003cp data-start=\"6237\" data-end=\"6249\"\u003e\u003cstrong data-start=\"6237\" data-end=\"6249\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"6250\" data-end=\"6261\"\u003e\n\u003cp data-start=\"6252\" data-end=\"6261\"\u003e\u003cstrong data-start=\"6252\" data-end=\"6261\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"6262\" data-end=\"6288\"\u003e\n\u003cp data-start=\"6264\" data-end=\"6288\"\u003e\u003cstrong data-start=\"6264\" data-end=\"6288\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6290\" data-end=\"6293\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6295\" data-end=\"6317\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6319\" data-end=\"6358\"\u003eOperating temperature\u003cbr data-start=\"6340\" data-end=\"6343\"\u003e\u003cstrong data-start=\"6343\" data-end=\"6358\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6360\" data-end=\"6405\"\u003eTemperature change rate\u003cbr data-start=\"6383\" data-end=\"6386\"\u003e\u003cstrong data-start=\"6386\" data-end=\"6405\"\u003e±0.3°C per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6407\" data-end=\"6440\"\u003eRelative humidity\u003cbr data-start=\"6424\" data-end=\"6427\"\u003e\u003cstrong data-start=\"6427\" data-end=\"6440\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6442\" data-end=\"6481\"\u003eHumidity change rate\u003cbr data-start=\"6462\" data-end=\"6465\"\u003e\u003cstrong data-start=\"6465\" data-end=\"6481\"\u003e±1% per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6483\" data-end=\"6486\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"6488\" data-end=\"6506\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"6508\" data-end=\"6534\"\u003ePan diameter\u003cbr data-start=\"6520\" data-end=\"6523\"\u003e\u003cstrong data-start=\"6523\" data-end=\"6534\"\u003e0.16 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6536\" data-end=\"6571\"\u003eChamber dimensions\u003cbr data-start=\"6554\" data-end=\"6557\"\u003e\u003cstrong data-start=\"6557\" data-end=\"6571\"\u003e90 × 90 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6573\" data-end=\"6576\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6578\" data-end=\"6599\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6601\" data-end=\"6666\"\u003ePackage dimensions\u003cbr data-start=\"6619\" data-end=\"6622\"\u003e\u003cstrong data-start=\"6622\" data-end=\"6666\"\u003e655 × 755 × 445 mm (26 × 30 × 18 inches)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6668\" data-end=\"6692\"\u003eUnit weight\u003cbr data-start=\"6679\" data-end=\"6682\"\u003e\u003cstrong data-start=\"6682\" data-end=\"6692\"\u003e20 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6694\" data-end=\"6722\"\u003eShipping weight\u003cbr data-start=\"6709\" data-end=\"6712\"\u003e\u003cstrong data-start=\"6712\" data-end=\"6722\"\u003e38 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6724\" data-end=\"6727\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6729\" data-end=\"6749\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6751\" data-end=\"6786\"\u003eAdapter\u003cbr data-start=\"6758\" data-end=\"6761\"\u003e\u003cstrong data-start=\"6761\" data-end=\"6786\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6788\" data-end=\"6817\"\u003eBalance input\u003cbr data-start=\"6801\" data-end=\"6804\"\u003e\u003cstrong data-start=\"6804\" data-end=\"6817\"\u003e12–15V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6819\" data-end=\"6822\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"6824\" data-end=\"6834\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"6836\" data-end=\"6868\"\u003e\u003cstrong data-start=\"6836\" data-end=\"6868\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282614481218,"sku":null,"price":22720.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/MYA_2.5Y__WL-109-0004_-removebg-preview.webp?v=1773590246","url":"https:\/\/summitsupplydirect.com\/products\/across-international-mya-2-5y-radwag-2-1-g-capacity-0-1-%c2%b5g-readability-o16-mm-microbalance","provider":"Summit Supply Direct","version":"1.0","type":"link"}