{"product_id":"across-international-ih70ab-70kw-mid-frequency-split-induction-heater-w-timers-30-80khz","title":"Across International IH70AB 70KW Mid-Frequency Split Induction Heater w\/ Timers 30-80KHz","description":"\u003ch2 data-section-id=\"1aqhidp\" data-start=\"387\" data-end=\"481\"\u003eHigh-Power 70 kW Industrial Induction Heater for Metal Heating, Brazing, and Heat Treatment\u003c\/h2\u003e\n\u003cp data-start=\"483\" data-end=\"742\"\u003eThe \u003cstrong data-start=\"487\" data-end=\"548\"\u003eAcross International IH70AB Dual-Station Induction Heater\u003c\/strong\u003e is a high-power \u003cstrong data-start=\"565\" data-end=\"613\"\u003e70 kW mid-frequency induction heating system\u003c\/strong\u003e engineered for rapid and energy-efficient heating of metals in industrial workshops, laboratories, and manufacturing facilities.\u003c\/p\u003e\n\u003cp data-start=\"744\" data-end=\"1009\"\u003eOperating within a \u003cstrong data-start=\"763\" data-end=\"792\"\u003e30–80 kHz frequency range\u003c\/strong\u003e, the IH70AB delivers precise and consistent heating for demanding applications such as \u003cstrong data-start=\"880\" data-end=\"1008\"\u003ediamond tool brazing, copper soldering, automotive heat-treating, metal cutting, and annealing of stainless steel components\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1011\" data-end=\"1353\"\u003eThis model features a \u003cstrong data-start=\"1033\" data-end=\"1063\"\u003edual-station configuration\u003c\/strong\u003e, allowing the heating coil assembly and controller to be separated by \u003cstrong data-start=\"1134\" data-end=\"1150\"\u003eup to 7 feet\u003c\/strong\u003e, improving safety and flexibility during operation. Its high power capacity, digital control system, and efficient cooling design make the IH70AB suitable for heavy-duty industrial heating applications.\u003c\/p\u003e\n\u003cp data-start=\"1355\" data-end=\"1461\"\u003e⚠ \u003cstrong data-start=\"1357\" data-end=\"1366\"\u003eNote:\u003c\/strong\u003e This model operates on \u003cstrong data-start=\"1390\" data-end=\"1421\"\u003e460–480 V three-phase power\u003c\/strong\u003e (380 V version available upon request).\u003c\/p\u003e\n\u003chr data-start=\"1463\" data-end=\"1466\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1468\" data-end=\"1482\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"lah0ls\" data-start=\"1484\" data-end=\"1522\"\u003e70 kW High-Power Induction Heating\u003c\/h3\u003e\n\u003cp data-start=\"1523\" data-end=\"1605\"\u003eProvides \u003cstrong data-start=\"1532\" data-end=\"1565\"\u003eup to 70 kW oscillating power\u003c\/strong\u003e for rapid heating of conductive metals.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gv96wh\" data-start=\"1607\" data-end=\"1643\"\u003eMid-Frequency Heating Technology\u003c\/h3\u003e\n\u003cp data-start=\"1644\" data-end=\"1746\"\u003eOperates within \u003cstrong data-start=\"1660\" data-end=\"1673\"\u003e30–80 kHz\u003c\/strong\u003e, making it ideal for heating small parts and precision metal components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1yiupm0\" data-start=\"1748\" data-end=\"1771\"\u003eDual-Station System\u003c\/h3\u003e\n\u003cp data-start=\"1772\" data-end=\"1931\"\u003eConnection cables allow the heater and controller to be separated by \u003cstrong data-start=\"1841\" data-end=\"1857\"\u003eup to 7 feet\u003c\/strong\u003e, enabling safer operation in high-temperature or industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14yefr0\" data-start=\"1933\" data-end=\"1967\"\u003eDigital Monitoring and Control\u003c\/h3\u003e\n\u003cp data-start=\"1968\" data-end=\"2023\"\u003eIntegrated digital displays allow operators to monitor:\u003c\/p\u003e\n\u003cul data-start=\"2025\" data-end=\"2100\"\u003e\n\u003cli data-section-id=\"2cyrbc\" data-start=\"2025\" data-end=\"2041\"\u003e\n\u003cp data-start=\"2027\" data-end=\"2041\"\u003eOutput power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19jzoy4\" data-start=\"2042\" data-end=\"2055\"\u003e\n\u003cp data-start=\"2044\" data-end=\"2055\"\u003eFrequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ec36k9\" data-start=\"2056\" data-end=\"2075\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2075\"\u003eHeating current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sq1bk\" data-start=\"2076\" data-end=\"2100\"\u003e\n\u003cp data-start=\"2078\" data-end=\"2100\"\u003eHeating cycle timing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5hlrvb\" data-start=\"2102\" data-end=\"2134\"\u003eRemote Foot Switch Operation\u003c\/h3\u003e\n\u003cp data-start=\"2135\" data-end=\"2235\"\u003eA \u003cstrong data-start=\"2137\" data-end=\"2166\"\u003e7-foot remote foot switch\u003c\/strong\u003e enables hands-free activation of heating cycles for improved safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mqq41m\" data-start=\"2237\" data-end=\"2267\"\u003eAutomatic and Manual Modes\u003c\/h3\u003e\n\u003cp data-start=\"2268\" data-end=\"2392\"\u003eSupports both \u003cstrong data-start=\"2282\" data-end=\"2310\"\u003eautomatic heating cycles\u003c\/strong\u003e and \u003cstrong data-start=\"2315\" data-end=\"2335\"\u003emanual operation\u003c\/strong\u003e, providing flexibility for various heating applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hxvx1c\" data-start=\"2394\" data-end=\"2424\"\u003ePortable Industrial Design\u003c\/h3\u003e\n\u003cp data-start=\"2425\" data-end=\"2538\"\u003eCompact units with durable construction allow easier installation and movement within workshops and laboratories.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dweqat\" data-start=\"2540\" data-end=\"2573\"\u003eCustom Induction Coil Options\u003c\/h3\u003e\n\u003cp data-start=\"2574\" data-end=\"2661\"\u003eInduction coils can be custom-designed depending on application requirements including:\u003c\/p\u003e\n\u003cul data-start=\"2663\" data-end=\"2739\"\u003e\n\u003cli data-section-id=\"d1kgkm\" data-start=\"2663\" data-end=\"2680\"\u003e\n\u003cp data-start=\"2665\" data-end=\"2680\"\u003eCoil diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n9haks\" data-start=\"2681\" data-end=\"2700\"\u003e\n\u003cp data-start=\"2683\" data-end=\"2700\"\u003eNumber of turns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17vgk45\" data-start=\"2701\" data-end=\"2723\"\u003e\n\u003cp data-start=\"2703\" data-end=\"2723\"\u003eCopper tubing size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"175k65\" data-start=\"2724\" data-end=\"2739\"\u003e\n\u003cp data-start=\"2726\" data-end=\"2739\"\u003eCoil length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2741\" data-end=\"2849\"\u003eAcross International provides \u003cstrong data-start=\"2771\" data-end=\"2848\"\u003ecustom coil manufacturing and sample testing at their New Jersey facility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2851\" data-end=\"2854\"\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"2856\" data-end=\"2878\"\u003eTypical Applications\u003c\/h1\u003e\n\u003cp data-start=\"2880\" data-end=\"2929\"\u003eThe IH70AB induction heater is commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"2931\" data-end=\"3209\"\u003e\n\u003cli data-section-id=\"1juszb3\" data-start=\"2931\" data-end=\"2957\"\u003e\n\u003cp data-start=\"2933\" data-end=\"2957\"\u003e\u003cstrong data-start=\"2933\" data-end=\"2957\"\u003eDiamond tool brazing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b4aa0s\" data-start=\"2958\" data-end=\"2985\"\u003e\n\u003cp data-start=\"2960\" data-end=\"2985\"\u003e\u003cstrong data-start=\"2960\" data-end=\"2985\"\u003eCopper pipe soldering\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"us0ik8\" data-start=\"2986\" data-end=\"3027\"\u003e\n\u003cp data-start=\"2988\" data-end=\"3027\"\u003e\u003cstrong data-start=\"2988\" data-end=\"3027\"\u003eAutomotive component heat treatment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hklhjq\" data-start=\"3028\" data-end=\"3070\"\u003e\n\u003cp data-start=\"3030\" data-end=\"3070\"\u003e\u003cstrong data-start=\"3030\" data-end=\"3070\"\u003eAnnealing stainless steel containers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pcrkxy\" data-start=\"3071\" data-end=\"3101\"\u003e\n\u003cp data-start=\"3073\" data-end=\"3101\"\u003e\u003cstrong data-start=\"3073\" data-end=\"3101\"\u003eIndustrial metal heating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s8tdua\" data-start=\"3102\" data-end=\"3133\"\u003e\n\u003cp data-start=\"3104\" data-end=\"3133\"\u003e\u003cstrong data-start=\"3104\" data-end=\"3133\"\u003eMetal forming and cutting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n154ok\" data-start=\"3134\" data-end=\"3174\"\u003e\n\u003cp data-start=\"3136\" data-end=\"3174\"\u003e\u003cstrong data-start=\"3136\" data-end=\"3174\"\u003ePrecious metal melting preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jg1mkl\" data-start=\"3175\" data-end=\"3209\"\u003e\n\u003cp data-start=\"3177\" data-end=\"3209\"\u003e\u003cstrong data-start=\"3177\" data-end=\"3209\"\u003eLaboratory materials testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3211\" data-end=\"3214\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"3216\" data-end=\"3233\"\u003eSafety Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"ba02zt\" data-start=\"3235\" data-end=\"3261\"\u003eOvervoltage Protection\u003c\/h3\u003e\n\u003cp data-start=\"3262\" data-end=\"3376\"\u003eThe system automatically shuts down if input voltage exceeds \u003cstrong data-start=\"3323\" data-end=\"3332\"\u003e245 V\u003c\/strong\u003e, activating an alarm and warning indicator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jh6w8j\" data-start=\"3378\" data-end=\"3401\"\u003eOverheat Protection\u003c\/h3\u003e\n\u003cp data-start=\"3402\" data-end=\"3523\"\u003eIf the \u003cstrong data-start=\"3409\" data-end=\"3453\"\u003eIGBT heat sink temperature exceeds 55 °C\u003c\/strong\u003e, the machine shuts down until safe operating temperature is restored.\u003c\/p\u003e\n\u003ch3 data-section-id=\"igahd7\" data-start=\"3525\" data-end=\"3567\"\u003eOvercurrent and Malfunction Protection\u003c\/h3\u003e\n\u003cp data-start=\"3568\" data-end=\"3597\"\u003eAutomatic shutdown occurs if:\u003c\/p\u003e\n\u003cul data-start=\"3599\" data-end=\"3803\"\u003e\n\u003cli data-section-id=\"s5iezp\" data-start=\"3599\" data-end=\"3631\"\u003e\n\u003cp data-start=\"3601\" data-end=\"3631\"\u003eInternal components overheat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wqu836\" data-start=\"3632\" data-end=\"3667\"\u003e\n\u003cp data-start=\"3634\" data-end=\"3667\"\u003eSignal interference is detected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nnwdbd\" data-start=\"3668\" data-end=\"3707\"\u003e\n\u003cp data-start=\"3670\" data-end=\"3707\"\u003eWorkpiece causes coil short circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15qxjv9\" data-start=\"3708\" data-end=\"3744\"\u003e\n\u003cp data-start=\"3710\" data-end=\"3744\"\u003eInduction coils touch each other\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18t118m\" data-start=\"3745\" data-end=\"3773\"\u003e\n\u003cp data-start=\"3747\" data-end=\"3773\"\u003eInput voltage is too low\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"176zar8\" data-start=\"3774\" data-end=\"3803\"\u003e\n\u003cp data-start=\"3776\" data-end=\"3803\"\u003eSystem malfunction occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aa7j7l\" data-start=\"3805\" data-end=\"3838\"\u003eLow Water Pressure Protection\u003c\/h3\u003e\n\u003cp data-start=\"3839\" data-end=\"3934\"\u003eThe heater shuts down automatically if cooling water pressure drops below \u003cstrong data-start=\"3913\" data-end=\"3933\"\u003e29 PSI (0.2 MPa)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3936\" data-end=\"3939\"\u003e\n\u003ch1 data-section-id=\"kqhnq2\" data-start=\"3941\" data-end=\"3973\"\u003eImportant Operating Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"3975\" data-end=\"4055\"\u003e⚠ Always wear \u003cstrong data-start=\"3989\" data-end=\"4027\"\u003eprotective gear and safety goggles\u003c\/strong\u003e when operating the machine.\u003c\/p\u003e\n\u003cp data-start=\"4057\" data-end=\"4087\"\u003eAdditional guidelines include:\u003c\/p\u003e\n\u003cul data-start=\"4089\" data-end=\"4407\"\u003e\n\u003cli data-section-id=\"rljb2f\" data-start=\"4089\" data-end=\"4141\"\u003e\n\u003cp data-start=\"4091\" data-end=\"4141\"\u003eCrucibles must remain \u003cstrong data-start=\"4113\" data-end=\"4141\"\u003ecovered during operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ob0pqc\" data-start=\"4142\" data-end=\"4181\"\u003e\n\u003cp data-start=\"4144\" data-end=\"4181\"\u003eAvoid prolonged \u003cstrong data-start=\"4160\" data-end=\"4181\"\u003eno-load operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ygh405\" data-start=\"4182\" data-end=\"4231\"\u003e\n\u003cp data-start=\"4184\" data-end=\"4231\"\u003eCooling water must be \u003cstrong data-start=\"4206\" data-end=\"4231\"\u003eclean and below 45 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1posuwe\" data-start=\"4232\" data-end=\"4271\"\u003e\n\u003cp data-start=\"4234\" data-end=\"4271\"\u003eMachine must be \u003cstrong data-start=\"4250\" data-end=\"4271\"\u003eproperly grounded\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17zkrjr\" data-start=\"4272\" data-end=\"4337\"\u003e\n\u003cp data-start=\"4274\" data-end=\"4337\"\u003eDo not use \u003cstrong data-start=\"4285\" data-end=\"4337\"\u003esingle-turn coils smaller than 4 inches diameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12kkb03\" data-start=\"4338\" data-end=\"4407\"\u003e\n\u003cp data-start=\"4340\" data-end=\"4407\"\u003e\u003cstrong data-start=\"4340\" data-end=\"4372\"\u003eThread tape must not be used\u003c\/strong\u003e during induction coil installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4409\" data-end=\"4412\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4414\" data-end=\"4440\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4442\" data-end=\"4450\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4451\" data-end=\"4461\"\u003e\u003cstrong data-start=\"4451\" data-end=\"4461\"\u003eIH70AB\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4463\" data-end=\"4466\"\u003e\n\u003ch2 data-section-id=\"15ra0yv\" data-start=\"4468\" data-end=\"4494\"\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cp data-start=\"4496\" data-end=\"4545\"\u003ePower supply\u003cbr data-start=\"4508\" data-end=\"4511\"\u003e\u003cstrong data-start=\"4511\" data-end=\"4545\"\u003e460 VAC, 50\/60 Hz, three-phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4547\" data-end=\"4579\"\u003eMaximum input current\u003cbr data-start=\"4568\" data-end=\"4571\"\u003e\u003cstrong data-start=\"4571\" data-end=\"4579\"\u003e88 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4581\" data-end=\"4630\"\u003eRecommended circuit breaker\u003cbr data-start=\"4608\" data-end=\"4611\"\u003e\u003cstrong data-start=\"4611\" data-end=\"4630\"\u003e110 A (3-phase)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4632\" data-end=\"4635\"\u003e\n\u003ch2 data-section-id=\"17i18f9\" data-start=\"4637\" data-end=\"4659\"\u003eHeating Performance\u003c\/h2\u003e\n\u003cp data-start=\"4661\" data-end=\"4693\"\u003eOutput frequency\u003cbr data-start=\"4677\" data-end=\"4680\"\u003e\u003cstrong data-start=\"4680\" data-end=\"4693\"\u003e30–80 kHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4695\" data-end=\"4738\"\u003eMaximum oscillating\/input power\u003cbr data-start=\"4726\" data-end=\"4729\"\u003e\u003cstrong data-start=\"4729\" data-end=\"4738\"\u003e70 kW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4740\" data-end=\"4762\"\u003eDuty cycle\u003cbr data-start=\"4750\" data-end=\"4753\"\u003e\u003cstrong data-start=\"4753\" data-end=\"4762\"\u003e100 %\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4764\" data-end=\"4796\"\u003eHeating timer\u003cbr data-start=\"4777\" data-end=\"4780\"\u003e\u003cstrong data-start=\"4780\" data-end=\"4796\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4798\" data-end=\"4828\"\u003eDwell timer\u003cbr data-start=\"4809\" data-end=\"4812\"\u003e\u003cstrong data-start=\"4812\" data-end=\"4828\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4830\" data-end=\"4862\"\u003eCooling timer\u003cbr data-start=\"4843\" data-end=\"4846\"\u003e\u003cstrong data-start=\"4846\" data-end=\"4862\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4864\" data-end=\"4867\"\u003e\n\u003ch2 data-section-id=\"1hrkr9r\" data-start=\"4869\" data-end=\"4886\"\u003eCooling System\u003c\/h2\u003e\n\u003cp data-start=\"4888\" data-end=\"4948\"\u003eCooling method\u003cbr data-start=\"4902\" data-end=\"4905\"\u003e\u003cstrong data-start=\"4905\" data-end=\"4948\"\u003eWater cooling with rear fan air cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4950\" data-end=\"4997\"\u003eMinimum water pressure\u003cbr data-start=\"4972\" data-end=\"4975\"\u003e\u003cstrong data-start=\"4975\" data-end=\"4997\"\u003e≥ 0.2 MPa (29 PSI)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4999\" data-end=\"5053\"\u003eRecommended pump capacity\u003cbr data-start=\"5024\" data-end=\"5027\"\u003e\u003cstrong data-start=\"5027\" data-end=\"5053\"\u003e\u0026gt; 1\/4 HP and \u0026gt; 240 GPH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5055\" data-end=\"5110\"\u003eWater flow rate\u003cbr data-start=\"5070\" data-end=\"5073\"\u003e\u003cstrong data-start=\"5073\" data-end=\"5110\"\u003e2.6 gallons per minute (10 L\/min)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5112\" data-end=\"5115\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5117\" data-end=\"5138\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5140\" data-end=\"5159\"\u003eController weight\u003c\/p\u003e\n\u003cul data-start=\"5161\" data-end=\"5204\"\u003e\n\u003cli data-section-id=\"1rufv6g\" data-start=\"5161\" data-end=\"5180\"\u003e\n\u003cp data-start=\"5163\" data-end=\"5180\"\u003eUnit: \u003cstrong data-start=\"5169\" data-end=\"5180\"\u003e155 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1099myt\" data-start=\"5181\" data-end=\"5204\"\u003e\n\u003cp data-start=\"5183\" data-end=\"5204\"\u003eShipping: \u003cstrong data-start=\"5193\" data-end=\"5204\"\u003e190 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5206\" data-end=\"5221\"\u003eHeater weight\u003c\/p\u003e\n\u003cul data-start=\"5223\" data-end=\"5266\"\u003e\n\u003cli data-section-id=\"1xp9125\" data-start=\"5223\" data-end=\"5242\"\u003e\n\u003cp data-start=\"5225\" data-end=\"5242\"\u003eUnit: \u003cstrong data-start=\"5231\" data-end=\"5242\"\u003e150 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3941cx\" data-start=\"5243\" data-end=\"5266\"\u003e\n\u003cp data-start=\"5245\" data-end=\"5266\"\u003eShipping: \u003cstrong data-start=\"5255\" data-end=\"5266\"\u003e185 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5268\" data-end=\"5315\"\u003eController dimensions\u003cbr data-start=\"5289\" data-end=\"5292\"\u003e\u003cstrong data-start=\"5292\" data-end=\"5315\"\u003e30 × 15 × 35 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5317\" data-end=\"5360\"\u003eHeater dimensions\u003cbr data-start=\"5334\" data-end=\"5337\"\u003e\u003cstrong data-start=\"5337\" data-end=\"5360\"\u003e32 × 14 × 18 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5362\" data-end=\"5398\"\u003eConnection cable length\u003cbr data-start=\"5385\" data-end=\"5388\"\u003e\u003cstrong data-start=\"5388\" data-end=\"5398\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5400\" data-end=\"5437\"\u003eFoot switch cable length\u003cbr data-start=\"5424\" data-end=\"5427\"\u003e\u003cstrong data-start=\"5427\" data-end=\"5437\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5439\" data-end=\"5442\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5444\" data-end=\"5465\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5467\" data-end=\"5681\"\u003e\n\u003cli data-section-id=\"1cuj5uy\" data-start=\"5467\" data-end=\"5506\"\u003e\n\u003cp data-start=\"5469\" data-end=\"5506\"\u003eIH70AB Induction Heater – \u003cstrong data-start=\"5495\" data-end=\"5504\"\u003e2 pcs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fvrxir\" data-start=\"5507\" data-end=\"5546\"\u003e\n\u003cp data-start=\"5509\" data-end=\"5546\"\u003eConnection Cable (7 ft) – \u003cstrong data-start=\"5535\" data-end=\"5544\"\u003e1 set\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z2nc61\" data-start=\"5547\" data-end=\"5587\"\u003e\n\u003cp data-start=\"5549\" data-end=\"5587\"\u003eRemote Foot Switch (7 ft) – \u003cstrong data-start=\"5577\" data-end=\"5585\"\u003e1 pc\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10vkfc9\" data-start=\"5588\" data-end=\"5630\"\u003e\n\u003cp data-start=\"5590\" data-end=\"5630\"\u003eStainless Steel Hose Clamp – \u003cstrong data-start=\"5619\" data-end=\"5628\"\u003e1 set\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1986jhp\" data-start=\"5631\" data-end=\"5651\"\u003e\n\u003cp data-start=\"5633\" data-end=\"5651\"\u003eFuse – \u003cstrong data-start=\"5640\" data-end=\"5649\"\u003e1 set\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cpgxjq\" data-start=\"5652\" data-end=\"5681\"\u003e\n\u003cp data-start=\"5654\" data-end=\"5681\"\u003eOperation Manual – \u003cstrong data-start=\"5673\" data-end=\"5681\"\u003e1 pc\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5683\" data-end=\"5756\"\u003eOptional \u003cstrong data-start=\"5692\" data-end=\"5732\"\u003ecustom copper tubing induction coils\u003c\/strong\u003e available upon request.\u003c\/p\u003e\n\u003chr data-start=\"5758\" data-end=\"5761\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5763\" data-end=\"5773\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5775\" data-end=\"5809\"\u003e\u003cstrong data-start=\"5775\" data-end=\"5809\"\u003eManufacturer Warranty Included\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282710655298,"sku":null,"price":19990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ih70ab_black_1.jpg?v=1773594936","url":"https:\/\/summitsupplydirect.com\/products\/across-international-ih70ab-70kw-mid-frequency-split-induction-heater-w-timers-30-80khz","provider":"Summit Supply Direct","version":"1.0","type":"link"}