{"product_id":"across-international-ih45ab-45kw-mid-frequency-split-induction-heater-w-timers-30-80khz","title":"Across International IH45AB 45KW Mid-Frequency Split Induction Heater w\/ Timers 30-80KHz","description":"\u003ch2 data-section-id=\"sdm3jf\" data-start=\"369\" data-end=\"463\"\u003eHigh-Power 45 kW Induction Heater for Industrial Metal Heating, Brazing, and Heat Treatment\u003c\/h2\u003e\n\u003cp data-start=\"465\" data-end=\"730\"\u003eThe \u003cstrong data-start=\"469\" data-end=\"530\"\u003eAcross International IH45AB Dual-Station Induction Heater\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"553\" data-end=\"601\"\u003e45 kW mid-frequency induction heating system\u003c\/strong\u003e designed for rapid and energy-efficient heating of metals in laboratories, manufacturing environments, and industrial workshops.\u003c\/p\u003e\n\u003cp data-start=\"732\" data-end=\"977\"\u003eOperating within a \u003cstrong data-start=\"751\" data-end=\"780\"\u003e30–80 kHz frequency range\u003c\/strong\u003e, the IH45AB provides precise and consistent heating for applications such as \u003cstrong data-start=\"858\" data-end=\"976\"\u003ediamond tool brazing, copper soldering, metal cutting, heat treatment, and annealing of stainless steel components\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"979\" data-end=\"1313\"\u003eThe system features a \u003cstrong data-start=\"1001\" data-end=\"1031\"\u003edual-station configuration\u003c\/strong\u003e, allowing the heating coil assembly and controller to be separated by \u003cstrong data-start=\"1102\" data-end=\"1118\"\u003eup to 7 feet\u003c\/strong\u003e, improving safety and flexibility during operation. Its powerful output, digital control system, and efficient cooling design make the IH45AB ideal for demanding industrial heating applications.\u003c\/p\u003e\n\u003cp data-start=\"1315\" data-end=\"1421\"\u003e⚠ \u003cstrong data-start=\"1317\" data-end=\"1326\"\u003eNote:\u003c\/strong\u003e This model operates on \u003cstrong data-start=\"1350\" data-end=\"1381\"\u003e460–480 V three-phase power\u003c\/strong\u003e (380 V version available upon request).\u003c\/p\u003e\n\u003chr data-start=\"1423\" data-end=\"1426\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1428\" data-end=\"1442\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"kssdfa\" data-start=\"1444\" data-end=\"1482\"\u003e45 kW High-Power Induction Heating\u003c\/h3\u003e\n\u003cp data-start=\"1483\" data-end=\"1580\"\u003eDelivers \u003cstrong data-start=\"1492\" data-end=\"1525\"\u003eup to 45 kW oscillating power\u003c\/strong\u003e for rapid heating of conductive metals and components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gv96wh\" data-start=\"1582\" data-end=\"1618\"\u003eMid-Frequency Heating Technology\u003c\/h3\u003e\n\u003cp data-start=\"1619\" data-end=\"1722\"\u003eOperates between \u003cstrong data-start=\"1636\" data-end=\"1649\"\u003e30–80 kHz\u003c\/strong\u003e, making it ideal for heating small parts and precision metal components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ytxdf4\" data-start=\"1724\" data-end=\"1755\"\u003eDual-Station Heating System\u003c\/h3\u003e\n\u003cp data-start=\"1756\" data-end=\"1915\"\u003eConnection cables allow the heater and controller to be separated by \u003cstrong data-start=\"1825\" data-end=\"1841\"\u003eup to 7 feet\u003c\/strong\u003e, enabling safer operation in high-temperature or industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14yefr0\" data-start=\"1917\" data-end=\"1951\"\u003eDigital Monitoring and Control\u003c\/h3\u003e\n\u003cp data-start=\"1952\" data-end=\"2004\"\u003eIntegrated displays provide real-time monitoring of:\u003c\/p\u003e\n\u003cul data-start=\"2006\" data-end=\"2081\"\u003e\n\u003cli data-section-id=\"2cyrbc\" data-start=\"2006\" data-end=\"2022\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2022\"\u003eOutput power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19jzoy4\" data-start=\"2023\" data-end=\"2036\"\u003e\n\u003cp data-start=\"2025\" data-end=\"2036\"\u003eFrequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ec36k9\" data-start=\"2037\" data-end=\"2056\"\u003e\n\u003cp data-start=\"2039\" data-end=\"2056\"\u003eHeating current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sq1bk\" data-start=\"2057\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2059\" data-end=\"2081\"\u003eHeating cycle timing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5hlrvb\" data-start=\"2083\" data-end=\"2115\"\u003eRemote Foot Switch Operation\u003c\/h3\u003e\n\u003cp data-start=\"2116\" data-end=\"2196\"\u003eA \u003cstrong data-start=\"2118\" data-end=\"2147\"\u003e7-foot remote foot switch\u003c\/strong\u003e allows hands-free operation and improved safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lchy27\" data-start=\"2198\" data-end=\"2238\"\u003eAutomatic and Manual Operation Modes\u003c\/h3\u003e\n\u003cp data-start=\"2239\" data-end=\"2335\"\u003eSupports both \u003cstrong data-start=\"2253\" data-end=\"2281\"\u003eautomatic heating cycles\u003c\/strong\u003e and \u003cstrong data-start=\"2286\" data-end=\"2304\"\u003emanual control\u003c\/strong\u003e, depending on the application.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hxvx1c\" data-start=\"2337\" data-end=\"2367\"\u003ePortable Industrial Design\u003c\/h3\u003e\n\u003cp data-start=\"2368\" data-end=\"2481\"\u003eCompact heater and controller units allow easier installation and repositioning within workshops or laboratories.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dweqat\" data-start=\"2483\" data-end=\"2516\"\u003eCustom Induction Coil Options\u003c\/h3\u003e\n\u003cp data-start=\"2517\" data-end=\"2602\"\u003eInduction coils can be custom designed depending on application requirements such as:\u003c\/p\u003e\n\u003cul data-start=\"2604\" data-end=\"2680\"\u003e\n\u003cli data-section-id=\"d1kgkm\" data-start=\"2604\" data-end=\"2621\"\u003e\n\u003cp data-start=\"2606\" data-end=\"2621\"\u003eCoil diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n9haks\" data-start=\"2622\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2624\" data-end=\"2641\"\u003eNumber of turns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17vgk45\" data-start=\"2642\" data-end=\"2664\"\u003e\n\u003cp data-start=\"2644\" data-end=\"2664\"\u003eCopper tubing size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"175k65\" data-start=\"2665\" data-end=\"2680\"\u003e\n\u003cp data-start=\"2667\" data-end=\"2680\"\u003eCoil length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2682\" data-end=\"2793\"\u003eAcross International also offers \u003cstrong data-start=\"2715\" data-end=\"2792\"\u003esample testing and custom coil manufacturing at their New Jersey facility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2795\" data-end=\"2798\"\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"2800\" data-end=\"2822\"\u003eTypical Applications\u003c\/h1\u003e\n\u003cp data-start=\"2824\" data-end=\"2873\"\u003eThe IH45AB induction heater is commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"2875\" data-end=\"3153\"\u003e\n\u003cli data-section-id=\"1juszb3\" data-start=\"2875\" data-end=\"2901\"\u003e\n\u003cp data-start=\"2877\" data-end=\"2901\"\u003e\u003cstrong data-start=\"2877\" data-end=\"2901\"\u003eDiamond tool brazing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b4aa0s\" data-start=\"2902\" data-end=\"2929\"\u003e\n\u003cp data-start=\"2904\" data-end=\"2929\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2929\"\u003eCopper pipe soldering\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"us0ik8\" data-start=\"2930\" data-end=\"2971\"\u003e\n\u003cp data-start=\"2932\" data-end=\"2971\"\u003e\u003cstrong data-start=\"2932\" data-end=\"2971\"\u003eAutomotive component heat treatment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hklhjq\" data-start=\"2972\" data-end=\"3014\"\u003e\n\u003cp data-start=\"2974\" data-end=\"3014\"\u003e\u003cstrong data-start=\"2974\" data-end=\"3014\"\u003eAnnealing stainless steel containers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pcrkxy\" data-start=\"3015\" data-end=\"3045\"\u003e\n\u003cp data-start=\"3017\" data-end=\"3045\"\u003e\u003cstrong data-start=\"3017\" data-end=\"3045\"\u003eIndustrial metal heating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s8tdua\" data-start=\"3046\" data-end=\"3077\"\u003e\n\u003cp data-start=\"3048\" data-end=\"3077\"\u003e\u003cstrong data-start=\"3048\" data-end=\"3077\"\u003eMetal forming and cutting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jg1mkl\" data-start=\"3078\" data-end=\"3112\"\u003e\n\u003cp data-start=\"3080\" data-end=\"3112\"\u003e\u003cstrong data-start=\"3080\" data-end=\"3112\"\u003eLaboratory materials testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n154ok\" data-start=\"3113\" data-end=\"3153\"\u003e\n\u003cp data-start=\"3115\" data-end=\"3153\"\u003e\u003cstrong data-start=\"3115\" data-end=\"3153\"\u003ePrecious metal melting preparation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3155\" data-end=\"3158\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"3160\" data-end=\"3177\"\u003eSafety Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"ba02zt\" data-start=\"3179\" data-end=\"3205\"\u003eOvervoltage Protection\u003c\/h3\u003e\n\u003cp data-start=\"3206\" data-end=\"3319\"\u003eThe machine automatically shuts down if input voltage exceeds \u003cstrong data-start=\"3268\" data-end=\"3277\"\u003e245 V\u003c\/strong\u003e, activating an alarm and indicator light.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jh6w8j\" data-start=\"3321\" data-end=\"3344\"\u003eOverheat Protection\u003c\/h3\u003e\n\u003cp data-start=\"3345\" data-end=\"3465\"\u003eIf the \u003cstrong data-start=\"3352\" data-end=\"3396\"\u003eIGBT heat sink temperature exceeds 55 °C\u003c\/strong\u003e, the heater shuts down until safe operating conditions are restored.\u003c\/p\u003e\n\u003ch3 data-section-id=\"igahd7\" data-start=\"3467\" data-end=\"3509\"\u003eOvercurrent and Malfunction Protection\u003c\/h3\u003e\n\u003cp data-start=\"3510\" data-end=\"3539\"\u003eAutomatic shutdown occurs if:\u003c\/p\u003e\n\u003cul data-start=\"3541\" data-end=\"3747\"\u003e\n\u003cli data-section-id=\"s5iezp\" data-start=\"3541\" data-end=\"3573\"\u003e\n\u003cp data-start=\"3543\" data-end=\"3573\"\u003eInternal components overheat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wqu836\" data-start=\"3574\" data-end=\"3609\"\u003e\n\u003cp data-start=\"3576\" data-end=\"3609\"\u003eSignal interference is detected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nnwdbd\" data-start=\"3610\" data-end=\"3649\"\u003e\n\u003cp data-start=\"3612\" data-end=\"3649\"\u003eWorkpiece causes coil short circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w2culs\" data-start=\"3650\" data-end=\"3688\"\u003e\n\u003cp data-start=\"3652\" data-end=\"3688\"\u003eInduction coils contact each other\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18t118m\" data-start=\"3689\" data-end=\"3717\"\u003e\n\u003cp data-start=\"3691\" data-end=\"3717\"\u003eInput voltage is too low\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"176zar8\" data-start=\"3718\" data-end=\"3747\"\u003e\n\u003cp data-start=\"3720\" data-end=\"3747\"\u003eSystem malfunction occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aa7j7l\" data-start=\"3749\" data-end=\"3782\"\u003eLow Water Pressure Protection\u003c\/h3\u003e\n\u003cp data-start=\"3783\" data-end=\"3878\"\u003eThe heater shuts down automatically if cooling water pressure drops below \u003cstrong data-start=\"3857\" data-end=\"3877\"\u003e29 PSI (0.2 MPa)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3880\" data-end=\"3883\"\u003e\n\u003ch1 data-section-id=\"kqhnq2\" data-start=\"3885\" data-end=\"3917\"\u003eImportant Operating Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"3919\" data-end=\"3999\"\u003e⚠ Always wear \u003cstrong data-start=\"3933\" data-end=\"3971\"\u003eprotective gear and safety goggles\u003c\/strong\u003e when operating the machine.\u003c\/p\u003e\n\u003cp data-start=\"4001\" data-end=\"4030\"\u003eAdditional safety guidelines:\u003c\/p\u003e\n\u003cul data-start=\"4032\" data-end=\"4360\"\u003e\n\u003cli data-section-id=\"rljb2f\" data-start=\"4032\" data-end=\"4084\"\u003e\n\u003cp data-start=\"4034\" data-end=\"4084\"\u003eCrucibles must remain \u003cstrong data-start=\"4056\" data-end=\"4084\"\u003ecovered during operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ob0pqc\" data-start=\"4085\" data-end=\"4124\"\u003e\n\u003cp data-start=\"4087\" data-end=\"4124\"\u003eAvoid prolonged \u003cstrong data-start=\"4103\" data-end=\"4124\"\u003eno-load operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ygh405\" data-start=\"4125\" data-end=\"4174\"\u003e\n\u003cp data-start=\"4127\" data-end=\"4174\"\u003eCooling water must be \u003cstrong data-start=\"4149\" data-end=\"4174\"\u003eclean and below 45 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10f065b\" data-start=\"4175\" data-end=\"4221\"\u003e\n\u003cp data-start=\"4177\" data-end=\"4221\"\u003eMachine must always be \u003cstrong data-start=\"4200\" data-end=\"4221\"\u003eproperly grounded\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16xlua8\" data-start=\"4222\" data-end=\"4290\"\u003e\n\u003cp data-start=\"4224\" data-end=\"4290\"\u003eDo not use \u003cstrong data-start=\"4235\" data-end=\"4290\"\u003esingle-turn coils smaller than 4 inches in diameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12kkb03\" data-start=\"4291\" data-end=\"4360\"\u003e\n\u003cp data-start=\"4293\" data-end=\"4360\"\u003e\u003cstrong data-start=\"4293\" data-end=\"4325\"\u003eThread tape must not be used\u003c\/strong\u003e during induction coil installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4362\" data-end=\"4365\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4367\" data-end=\"4393\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4395\" data-end=\"4403\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4404\" data-end=\"4414\"\u003e\u003cstrong data-start=\"4404\" data-end=\"4414\"\u003eIH45AB\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4416\" data-end=\"4419\"\u003e\n\u003ch2 data-section-id=\"15ra0yv\" data-start=\"4421\" data-end=\"4447\"\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cp data-start=\"4449\" data-end=\"4498\"\u003ePower supply\u003cbr data-start=\"4461\" data-end=\"4464\"\u003e\u003cstrong data-start=\"4464\" data-end=\"4498\"\u003e460 VAC, 50\/60 Hz, three-phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4500\" data-end=\"4532\"\u003eMaximum input current\u003cbr data-start=\"4521\" data-end=\"4524\"\u003e\u003cstrong data-start=\"4524\" data-end=\"4532\"\u003e57 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4534\" data-end=\"4582\"\u003eRecommended circuit breaker\u003cbr data-start=\"4561\" data-end=\"4564\"\u003e\u003cstrong data-start=\"4564\" data-end=\"4582\"\u003e71 A (3-phase)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4584\" data-end=\"4587\"\u003e\n\u003ch2 data-section-id=\"17i18f9\" data-start=\"4589\" data-end=\"4611\"\u003eHeating Performance\u003c\/h2\u003e\n\u003cp data-start=\"4613\" data-end=\"4645\"\u003eOutput frequency\u003cbr data-start=\"4629\" data-end=\"4632\"\u003e\u003cstrong data-start=\"4632\" data-end=\"4645\"\u003e30–80 kHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4647\" data-end=\"4690\"\u003eMaximum oscillating\/input power\u003cbr data-start=\"4678\" data-end=\"4681\"\u003e\u003cstrong data-start=\"4681\" data-end=\"4690\"\u003e45 kW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4692\" data-end=\"4714\"\u003eDuty cycle\u003cbr data-start=\"4702\" data-end=\"4705\"\u003e\u003cstrong data-start=\"4705\" data-end=\"4714\"\u003e100 %\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4716\" data-end=\"4748\"\u003eHeating timer\u003cbr data-start=\"4729\" data-end=\"4732\"\u003e\u003cstrong data-start=\"4732\" data-end=\"4748\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4750\" data-end=\"4780\"\u003eDwell timer\u003cbr data-start=\"4761\" data-end=\"4764\"\u003e\u003cstrong data-start=\"4764\" data-end=\"4780\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4782\" data-end=\"4814\"\u003eCooling timer\u003cbr data-start=\"4795\" data-end=\"4798\"\u003e\u003cstrong data-start=\"4798\" data-end=\"4814\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4816\" data-end=\"4819\"\u003e\n\u003ch2 data-section-id=\"1hrkr9r\" data-start=\"4821\" data-end=\"4838\"\u003eCooling System\u003c\/h2\u003e\n\u003cp data-start=\"4840\" data-end=\"4900\"\u003eCooling method\u003cbr data-start=\"4854\" data-end=\"4857\"\u003e\u003cstrong data-start=\"4857\" data-end=\"4900\"\u003eWater cooling with rear fan air cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4902\" data-end=\"4949\"\u003eMinimum water pressure\u003cbr data-start=\"4924\" data-end=\"4927\"\u003e\u003cstrong data-start=\"4927\" data-end=\"4949\"\u003e≥ 0.2 MPa (29 PSI)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4951\" data-end=\"5005\"\u003eRecommended pump capacity\u003cbr data-start=\"4976\" data-end=\"4979\"\u003e\u003cstrong data-start=\"4979\" data-end=\"5005\"\u003e\u0026gt; 1\/4 HP and \u0026gt; 240 GPH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5007\" data-end=\"5061\"\u003eWater flow rate\u003cbr data-start=\"5022\" data-end=\"5025\"\u003e\u003cstrong data-start=\"5025\" data-end=\"5061\"\u003e1.6 gallons per minute (6 L\/min)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5063\" data-end=\"5066\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5068\" data-end=\"5089\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5091\" data-end=\"5122\"\u003eController weight\u003cbr data-start=\"5108\" data-end=\"5111\"\u003e\u003cstrong data-start=\"5111\" data-end=\"5122\"\u003e110 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5124\" data-end=\"5150\"\u003eHeater weight\u003cbr data-start=\"5137\" data-end=\"5140\"\u003e\u003cstrong data-start=\"5140\" data-end=\"5150\"\u003e84 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5152\" data-end=\"5193\"\u003eController size\u003cbr data-start=\"5167\" data-end=\"5170\"\u003e\u003cstrong data-start=\"5170\" data-end=\"5193\"\u003e25 × 12 × 21 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5195\" data-end=\"5232\"\u003eHeater size\u003cbr data-start=\"5206\" data-end=\"5209\"\u003e\u003cstrong data-start=\"5209\" data-end=\"5232\"\u003e20 × 11 × 16 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5234\" data-end=\"5270\"\u003eConnection cable length\u003cbr data-start=\"5257\" data-end=\"5260\"\u003e\u003cstrong data-start=\"5260\" data-end=\"5270\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5272\" data-end=\"5309\"\u003eFoot switch cable length\u003cbr data-start=\"5296\" data-end=\"5299\"\u003e\u003cstrong data-start=\"5299\" data-end=\"5309\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5311\" data-end=\"5314\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5316\" data-end=\"5337\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5339\" data-end=\"5597\"\u003e\n\u003cli data-section-id=\"1r92q07\" data-start=\"5339\" data-end=\"5370\"\u003e\n\u003cp data-start=\"5341\" data-end=\"5370\"\u003eIH45AB Power Supply – 1 set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u57hmb\" data-start=\"5371\" data-end=\"5406\"\u003e\n\u003cp data-start=\"5373\" data-end=\"5406\"\u003eConnection Cable (7 ft) – 1 set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7aiw61\" data-start=\"5407\" data-end=\"5443\"\u003e\n\u003cp data-start=\"5409\" data-end=\"5443\"\u003eRemote Foot Switch (7 ft) – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fgl66w\" data-start=\"5444\" data-end=\"5466\"\u003e\n\u003cp data-start=\"5446\" data-end=\"5466\"\u003e2-Pin Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g6hcqn\" data-start=\"5467\" data-end=\"5489\"\u003e\n\u003cp data-start=\"5469\" data-end=\"5489\"\u003e5-Pin Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r4xg1b\" data-start=\"5490\" data-end=\"5512\"\u003e\n\u003cp data-start=\"5492\" data-end=\"5512\"\u003ePower Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pgg8mp\" data-start=\"5513\" data-end=\"5552\"\u003e\n\u003cp data-start=\"5515\" data-end=\"5552\"\u003eStainless Steel Hose Clamps – 8 pcs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v77jfv\" data-start=\"5553\" data-end=\"5569\"\u003e\n\u003cp data-start=\"5555\" data-end=\"5569\"\u003eFuse – 5 pcs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e840k6\" data-start=\"5570\" data-end=\"5597\"\u003e\n\u003cp data-start=\"5572\" data-end=\"5597\"\u003eOperation Manual – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5599\" data-end=\"5661\"\u003eOptional copper tubing induction coils available upon request.\u003c\/p\u003e\n\u003chr data-start=\"5663\" data-end=\"5666\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5668\" data-end=\"5678\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5680\" data-end=\"5714\"\u003e\u003cstrong data-start=\"5680\" data-end=\"5714\"\u003eManufacturer Warranty Included\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282679427394,"sku":null,"price":11990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ih70ab_black.jpg?v=1773594222","url":"https:\/\/summitsupplydirect.com\/products\/across-international-ih45ab-45kw-mid-frequency-split-induction-heater-w-timers-30-80khz","provider":"Summit Supply Direct","version":"1.0","type":"link"}