{"product_id":"across-international-ih35ab-35kw-mid-frequency-split-induction-heater-w-timers-30-80khz","title":"Across International IH35AB 35KW Mid-Frequency Split Induction Heater w\/ Timers 30-80KHz","description":"\u003ch2 data-section-id=\"ubs18s\" data-start=\"372\" data-end=\"466\"\u003eHigh-Power 35 kW Industrial Induction Heater for Metal Heating, Brazing, and Heat Treatment\u003c\/h2\u003e\n\u003cp data-start=\"468\" data-end=\"725\"\u003eThe \u003cstrong data-start=\"472\" data-end=\"533\"\u003eAcross International IH35AB Dual-Station Induction Heater\u003c\/strong\u003e is a powerful \u003cstrong data-start=\"548\" data-end=\"596\"\u003e35 kW mid-frequency induction heating system\u003c\/strong\u003e designed for rapid and energy-efficient heating of metals in laboratories, manufacturing environments, and industrial workshops.\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"972\"\u003eOperating within a \u003cstrong data-start=\"746\" data-end=\"775\"\u003e30–80 kHz frequency range\u003c\/strong\u003e, the IH35AB provides precise and controlled heating for applications such as \u003cstrong data-start=\"853\" data-end=\"971\"\u003ediamond tool brazing, copper soldering, metal cutting, heat treatment, and annealing of stainless steel components\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"974\" data-end=\"1282\"\u003eThe system features a \u003cstrong data-start=\"996\" data-end=\"1026\"\u003edual-station configuration\u003c\/strong\u003e, allowing the heating coil assembly and controller to be separated by \u003cstrong data-start=\"1097\" data-end=\"1113\"\u003eup to 7 feet\u003c\/strong\u003e. This design enables operators to remain safely away from high temperatures, debris, or corrosive environments while maintaining precise control of the heating process.\u003c\/p\u003e\n\u003cp data-start=\"1284\" data-end=\"1508\"\u003eWith \u003cstrong data-start=\"1289\" data-end=\"1367\"\u003ehigh power output, digital control displays, and efficient cooling systems\u003c\/strong\u003e, the IH35AB is an excellent solution for industrial heating applications requiring \u003cstrong data-start=\"1451\" data-end=\"1507\"\u003ereliable performance and precise temperature control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1510\" data-end=\"1577\"\u003e⚠ \u003cstrong data-start=\"1512\" data-end=\"1521\"\u003eNote:\u003c\/strong\u003e This model operates on \u003cstrong data-start=\"1545\" data-end=\"1576\"\u003e460–480 V three-phase power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1579\" data-end=\"1582\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1584\" data-end=\"1598\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"2ejp75\" data-start=\"1600\" data-end=\"1638\"\u003e35 kW High-Power Induction Heating\u003c\/h3\u003e\n\u003cp data-start=\"1639\" data-end=\"1723\"\u003eProvides \u003cstrong data-start=\"1648\" data-end=\"1675\"\u003eup to 35 kW input power\u003c\/strong\u003e, delivering rapid heating of conductive metals.\u003c\/p\u003e\n\u003ch3 data-section-id=\"gv96wh\" data-start=\"1725\" data-end=\"1761\"\u003eMid-Frequency Heating Technology\u003c\/h3\u003e\n\u003cp data-start=\"1762\" data-end=\"1859\"\u003eOperates between \u003cstrong data-start=\"1779\" data-end=\"1792\"\u003e30–80 kHz\u003c\/strong\u003e, making it ideal for heating small parts and precision components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ytxdf4\" data-start=\"1861\" data-end=\"1892\"\u003eDual-Station Heating System\u003c\/h3\u003e\n\u003cp data-start=\"1893\" data-end=\"2046\"\u003eThe heater and controller can be separated by \u003cstrong data-start=\"1939\" data-end=\"1967\"\u003e7-foot connection cables\u003c\/strong\u003e, allowing safer operation and flexible positioning in industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbpq1s\" data-start=\"2048\" data-end=\"2075\"\u003ePrecise Digital Control\u003c\/h3\u003e\n\u003cp data-start=\"2076\" data-end=\"2125\"\u003eDigital displays provide real-time monitoring of:\u003c\/p\u003e\n\u003cul data-start=\"2127\" data-end=\"2186\"\u003e\n\u003cli data-section-id=\"7p5nt4\" data-start=\"2127\" data-end=\"2141\"\u003e\n\u003cp data-start=\"2129\" data-end=\"2141\"\u003eOutput power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b77bik\" data-start=\"2142\" data-end=\"2153\"\u003e\n\u003cp data-start=\"2144\" data-end=\"2153\"\u003eFrequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"564jd\" data-start=\"2154\" data-end=\"2171\"\u003e\n\u003cp data-start=\"2156\" data-end=\"2171\"\u003eHeating current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rn6n9h\" data-start=\"2172\" data-end=\"2186\"\u003e\n\u003cp data-start=\"2174\" data-end=\"2186\"\u003eHeating time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"5hlrvb\" data-start=\"2188\" data-end=\"2220\"\u003eRemote Foot Switch Operation\u003c\/h3\u003e\n\u003cp data-start=\"2221\" data-end=\"2329\"\u003eA \u003cstrong data-start=\"2223\" data-end=\"2245\"\u003e7-foot foot switch\u003c\/strong\u003e allows hands-free activation of heating cycles for improved safety and convenience.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lchy27\" data-start=\"2331\" data-end=\"2371\"\u003eAutomatic and Manual Operation Modes\u003c\/h3\u003e\n\u003cp data-start=\"2372\" data-end=\"2497\"\u003eSupports both \u003cstrong data-start=\"2386\" data-end=\"2414\"\u003eautomatic heating cycles\u003c\/strong\u003e and \u003cstrong data-start=\"2419\" data-end=\"2439\"\u003emanual operation\u003c\/strong\u003e, allowing flexibility for different heating applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hxvx1c\" data-start=\"2499\" data-end=\"2529\"\u003ePortable Industrial Design\u003c\/h3\u003e\n\u003cp data-start=\"2530\" data-end=\"2631\"\u003eCompact system with \u003cstrong data-start=\"2550\" data-end=\"2570\"\u003ebuilt-in handles\u003c\/strong\u003e enables easier relocation within workshops and laboratories.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dweqat\" data-start=\"2633\" data-end=\"2666\"\u003eCustom Induction Coil Options\u003c\/h3\u003e\n\u003cp data-start=\"2667\" data-end=\"2783\"\u003eCustom induction coils can be designed for specialized applications. Coil performance depends on parameters such as:\u003c\/p\u003e\n\u003cul data-start=\"2785\" data-end=\"2853\"\u003e\n\u003cli data-section-id=\"k8cn6u\" data-start=\"2785\" data-end=\"2800\"\u003e\n\u003cp data-start=\"2787\" data-end=\"2800\"\u003eCoil diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckytho\" data-start=\"2801\" data-end=\"2818\"\u003e\n\u003cp data-start=\"2803\" data-end=\"2818\"\u003eNumber of turns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ylyimt\" data-start=\"2819\" data-end=\"2839\"\u003e\n\u003cp data-start=\"2821\" data-end=\"2839\"\u003eCopper tubing size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1510gnx\" data-start=\"2840\" data-end=\"2853\"\u003e\n\u003cp data-start=\"2842\" data-end=\"2853\"\u003eCoil length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2855\" data-end=\"2961\"\u003eAcross International provides \u003cstrong data-start=\"2885\" data-end=\"2960\"\u003ecustom coil fabrication and sample testing at their New Jersey facility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2963\" data-end=\"2966\"\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"2968\" data-end=\"2990\"\u003eTypical Applications\u003c\/h1\u003e\n\u003cp data-start=\"2992\" data-end=\"3041\"\u003eThe IH35AB induction heater is commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"3043\" data-end=\"3280\"\u003e\n\u003cli data-section-id=\"1juszb3\" data-start=\"3043\" data-end=\"3069\"\u003e\n\u003cp data-start=\"3045\" data-end=\"3069\"\u003e\u003cstrong data-start=\"3045\" data-end=\"3069\"\u003eDiamond tool brazing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b4aa0s\" data-start=\"3070\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3072\" data-end=\"3097\"\u003e\u003cstrong data-start=\"3072\" data-end=\"3097\"\u003eCopper pipe soldering\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"us0ik8\" data-start=\"3098\" data-end=\"3139\"\u003e\n\u003cp data-start=\"3100\" data-end=\"3139\"\u003e\u003cstrong data-start=\"3100\" data-end=\"3139\"\u003eAutomotive component heat treatment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hklhjq\" data-start=\"3140\" data-end=\"3182\"\u003e\n\u003cp data-start=\"3142\" data-end=\"3182\"\u003e\u003cstrong data-start=\"3142\" data-end=\"3182\"\u003eAnnealing stainless steel containers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s8tdua\" data-start=\"3183\" data-end=\"3214\"\u003e\n\u003cp data-start=\"3185\" data-end=\"3214\"\u003e\u003cstrong data-start=\"3185\" data-end=\"3214\"\u003eMetal forming and cutting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pcrkxy\" data-start=\"3215\" data-end=\"3245\"\u003e\n\u003cp data-start=\"3217\" data-end=\"3245\"\u003e\u003cstrong data-start=\"3217\" data-end=\"3245\"\u003eIndustrial metal heating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jg1mkl\" data-start=\"3246\" data-end=\"3280\"\u003e\n\u003cp data-start=\"3248\" data-end=\"3280\"\u003e\u003cstrong data-start=\"3248\" data-end=\"3280\"\u003eLaboratory materials testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3282\" data-end=\"3285\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"3287\" data-end=\"3304\"\u003eSafety Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"ba02zt\" data-start=\"3306\" data-end=\"3332\"\u003eOvervoltage Protection\u003c\/h3\u003e\n\u003cp data-start=\"3333\" data-end=\"3448\"\u003eThe machine automatically shuts down if input voltage exceeds \u003cstrong data-start=\"3395\" data-end=\"3404\"\u003e245 V\u003c\/strong\u003e, activating an alarm and warning indicator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jh6w8j\" data-start=\"3450\" data-end=\"3473\"\u003eOverheat Protection\u003c\/h3\u003e\n\u003cp data-start=\"3474\" data-end=\"3594\"\u003eIf the \u003cstrong data-start=\"3481\" data-end=\"3525\"\u003eIGBT heat sink temperature exceeds 55 °C\u003c\/strong\u003e, the heater shuts down until safe operating conditions are restored.\u003c\/p\u003e\n\u003ch3 data-section-id=\"igahd7\" data-start=\"3596\" data-end=\"3638\"\u003eOvercurrent and Malfunction Protection\u003c\/h3\u003e\n\u003cp data-start=\"3639\" data-end=\"3668\"\u003eAutomatic shutdown occurs if:\u003c\/p\u003e\n\u003cul data-start=\"3670\" data-end=\"3859\"\u003e\n\u003cli data-section-id=\"uzsdyf\" data-start=\"3670\" data-end=\"3699\"\u003e\n\u003cp data-start=\"3672\" data-end=\"3699\"\u003eMachine components overheat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xvxvhx\" data-start=\"3700\" data-end=\"3728\"\u003e\n\u003cp data-start=\"3702\" data-end=\"3728\"\u003eSignal interference occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yj3yeh\" data-start=\"3729\" data-end=\"3766\"\u003e\n\u003cp data-start=\"3731\" data-end=\"3766\"\u003eWorkpiece causes coil short circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ns9l91\" data-start=\"3767\" data-end=\"3801\"\u003e\n\u003cp data-start=\"3769\" data-end=\"3801\"\u003eInduction coils touch each other\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m7qzgm\" data-start=\"3802\" data-end=\"3831\"\u003e\n\u003cp data-start=\"3804\" data-end=\"3831\"\u003eInput voltage drops too low\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1alzpro\" data-start=\"3832\" data-end=\"3859\"\u003e\n\u003cp data-start=\"3834\" data-end=\"3859\"\u003eSystem malfunction occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aa7j7l\" data-start=\"3861\" data-end=\"3894\"\u003eLow Water Pressure Protection\u003c\/h3\u003e\n\u003cp data-start=\"3895\" data-end=\"3990\"\u003eThe system shuts down automatically if cooling water pressure drops below \u003cstrong data-start=\"3969\" data-end=\"3989\"\u003e29 PSI (0.2 MPa)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3992\" data-end=\"3995\"\u003e\n\u003ch1 data-section-id=\"kqhnq2\" data-start=\"3997\" data-end=\"4029\"\u003eImportant Operating Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"4031\" data-end=\"4111\"\u003e⚠ Always wear \u003cstrong data-start=\"4045\" data-end=\"4083\"\u003eprotective gear and safety goggles\u003c\/strong\u003e when operating the machine.\u003c\/p\u003e\n\u003cp data-start=\"4113\" data-end=\"4143\"\u003eAdditional guidelines include:\u003c\/p\u003e\n\u003cul data-start=\"4145\" data-end=\"4463\"\u003e\n\u003cli data-section-id=\"rljb2f\" data-start=\"4145\" data-end=\"4197\"\u003e\n\u003cp data-start=\"4147\" data-end=\"4197\"\u003eCrucibles must remain \u003cstrong data-start=\"4169\" data-end=\"4197\"\u003ecovered during operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ob0pqc\" data-start=\"4198\" data-end=\"4237\"\u003e\n\u003cp data-start=\"4200\" data-end=\"4237\"\u003eAvoid prolonged \u003cstrong data-start=\"4216\" data-end=\"4237\"\u003eno-load operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ygh405\" data-start=\"4238\" data-end=\"4287\"\u003e\n\u003cp data-start=\"4240\" data-end=\"4287\"\u003eCooling water must be \u003cstrong data-start=\"4262\" data-end=\"4287\"\u003eclean and below 45 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10f065b\" data-start=\"4288\" data-end=\"4334\"\u003e\n\u003cp data-start=\"4290\" data-end=\"4334\"\u003eMachine must always be \u003cstrong data-start=\"4313\" data-end=\"4334\"\u003eproperly grounded\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16xlua8\" data-start=\"4335\" data-end=\"4403\"\u003e\n\u003cp data-start=\"4337\" data-end=\"4403\"\u003eDo not use \u003cstrong data-start=\"4348\" data-end=\"4403\"\u003esingle-turn coils smaller than 4 inches in diameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n20dyy\" data-start=\"4404\" data-end=\"4463\"\u003e\n\u003cp data-start=\"4406\" data-end=\"4463\"\u003e\u003cstrong data-start=\"4406\" data-end=\"4438\"\u003eThread tape must not be used\u003c\/strong\u003e during coil installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4465\" data-end=\"4468\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4470\" data-end=\"4496\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4498\" data-end=\"4506\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4507\" data-end=\"4517\"\u003e\u003cstrong data-start=\"4507\" data-end=\"4517\"\u003eIH35AB\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4519\" data-end=\"4522\"\u003e\n\u003ch2 data-section-id=\"15ra0yv\" data-start=\"4524\" data-end=\"4550\"\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cp data-start=\"4552\" data-end=\"4601\"\u003ePower supply\u003cbr data-start=\"4564\" data-end=\"4567\"\u003e\u003cstrong data-start=\"4567\" data-end=\"4601\"\u003e460 VAC, 50\/60 Hz, three-phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4603\" data-end=\"4635\"\u003eMaximum input current\u003cbr data-start=\"4624\" data-end=\"4627\"\u003e\u003cstrong data-start=\"4627\" data-end=\"4635\"\u003e44 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4637\" data-end=\"4685\"\u003eRecommended circuit breaker\u003cbr data-start=\"4664\" data-end=\"4667\"\u003e\u003cstrong data-start=\"4667\" data-end=\"4685\"\u003e55 A (3-phase)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4687\" data-end=\"4690\"\u003e\n\u003ch2 data-section-id=\"17i18f9\" data-start=\"4692\" data-end=\"4714\"\u003eHeating Performance\u003c\/h2\u003e\n\u003cp data-start=\"4716\" data-end=\"4748\"\u003eOutput frequency\u003cbr data-start=\"4732\" data-end=\"4735\"\u003e\u003cstrong data-start=\"4735\" data-end=\"4748\"\u003e30–80 kHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4750\" data-end=\"4781\"\u003eMaximum input power\u003cbr data-start=\"4769\" data-end=\"4772\"\u003e\u003cstrong data-start=\"4772\" data-end=\"4781\"\u003e35 kW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4783\" data-end=\"4805\"\u003eDuty cycle\u003cbr data-start=\"4793\" data-end=\"4796\"\u003e\u003cstrong data-start=\"4796\" data-end=\"4805\"\u003e100 %\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4807\" data-end=\"4839\"\u003eHeating timer\u003cbr data-start=\"4820\" data-end=\"4823\"\u003e\u003cstrong data-start=\"4823\" data-end=\"4839\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4841\" data-end=\"4871\"\u003eDwell timer\u003cbr data-start=\"4852\" data-end=\"4855\"\u003e\u003cstrong data-start=\"4855\" data-end=\"4871\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4873\" data-end=\"4905\"\u003eCooling timer\u003cbr data-start=\"4886\" data-end=\"4889\"\u003e\u003cstrong data-start=\"4889\" data-end=\"4905\"\u003e1–99 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4907\" data-end=\"4910\"\u003e\n\u003ch2 data-section-id=\"1hrkr9r\" data-start=\"4912\" data-end=\"4929\"\u003eCooling System\u003c\/h2\u003e\n\u003cp data-start=\"4931\" data-end=\"4991\"\u003eCooling method\u003cbr data-start=\"4945\" data-end=\"4948\"\u003e\u003cstrong data-start=\"4948\" data-end=\"4991\"\u003eWater cooling with rear fan air cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4993\" data-end=\"5040\"\u003eMinimum water pressure\u003cbr data-start=\"5015\" data-end=\"5018\"\u003e\u003cstrong data-start=\"5018\" data-end=\"5040\"\u003e≥ 0.2 MPa (29 PSI)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5042\" data-end=\"5096\"\u003eRecommended pump capacity\u003cbr data-start=\"5067\" data-end=\"5070\"\u003e\u003cstrong data-start=\"5070\" data-end=\"5096\"\u003e\u0026gt; 1\/4 HP and \u0026gt; 240 GPH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5098\" data-end=\"5152\"\u003eWater flow rate\u003cbr data-start=\"5113\" data-end=\"5116\"\u003e\u003cstrong data-start=\"5116\" data-end=\"5152\"\u003e1.6 gallons per minute (6 L\/min)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5154\" data-end=\"5198\"\u003eRecommended water temperature\u003cbr data-start=\"5183\" data-end=\"5186\"\u003e\u003cstrong data-start=\"5186\" data-end=\"5198\"\u003e25–30 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5200\" data-end=\"5203\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5205\" data-end=\"5226\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5228\" data-end=\"5258\"\u003eController weight\u003cbr data-start=\"5245\" data-end=\"5248\"\u003e\u003cstrong data-start=\"5248\" data-end=\"5258\"\u003e75 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5260\" data-end=\"5286\"\u003eHeater weight\u003cbr data-start=\"5273\" data-end=\"5276\"\u003e\u003cstrong data-start=\"5276\" data-end=\"5286\"\u003e70 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5288\" data-end=\"5354\"\u003ePower supply dimensions\u003cbr data-start=\"5311\" data-end=\"5314\"\u003e\u003cstrong data-start=\"5314\" data-end=\"5354\"\u003e10.25 × 20.5 × 18 inches (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5356\" data-end=\"5417\"\u003eCoil station dimensions\u003cbr data-start=\"5379\" data-end=\"5382\"\u003e\u003cstrong data-start=\"5382\" data-end=\"5417\"\u003e12 × 18 × 16 inches (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5419\" data-end=\"5464\"\u003eShipping dimensions\u003cbr data-start=\"5438\" data-end=\"5441\"\u003e\u003cstrong data-start=\"5441\" data-end=\"5464\"\u003e30 × 28 × 29 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5466\" data-end=\"5502\"\u003eConnection cable length\u003cbr data-start=\"5489\" data-end=\"5492\"\u003e\u003cstrong data-start=\"5492\" data-end=\"5502\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5504\" data-end=\"5541\"\u003eFoot switch cable length\u003cbr data-start=\"5528\" data-end=\"5531\"\u003e\u003cstrong data-start=\"5531\" data-end=\"5541\"\u003e7 feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5543\" data-end=\"5546\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5548\" data-end=\"5569\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5571\" data-end=\"5851\"\u003e\n\u003cli data-section-id=\"1plswdt\" data-start=\"5571\" data-end=\"5601\"\u003e\n\u003cp data-start=\"5573\" data-end=\"5601\"\u003eIH35AB Power Supply – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u57hmb\" data-start=\"5602\" data-end=\"5637\"\u003e\n\u003cp data-start=\"5604\" data-end=\"5637\"\u003eConnection Cable (7 ft) – 1 set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7aiw61\" data-start=\"5638\" data-end=\"5674\"\u003e\n\u003cp data-start=\"5640\" data-end=\"5674\"\u003eRemote Foot Switch (7 ft) – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ndnmz4\" data-start=\"5675\" data-end=\"5697\"\u003e\n\u003cp data-start=\"5677\" data-end=\"5697\"\u003e0–5 V Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fgl66w\" data-start=\"5698\" data-end=\"5720\"\u003e\n\u003cp data-start=\"5700\" data-end=\"5720\"\u003e2-Pin Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g6hcqn\" data-start=\"5721\" data-end=\"5743\"\u003e\n\u003cp data-start=\"5723\" data-end=\"5743\"\u003e5-Pin Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r4xg1b\" data-start=\"5744\" data-end=\"5766\"\u003e\n\u003cp data-start=\"5746\" data-end=\"5766\"\u003ePower Cable – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pgg8mp\" data-start=\"5767\" data-end=\"5806\"\u003e\n\u003cp data-start=\"5769\" data-end=\"5806\"\u003eStainless Steel Hose Clamps – 8 pcs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v77jfv\" data-start=\"5807\" data-end=\"5823\"\u003e\n\u003cp data-start=\"5809\" data-end=\"5823\"\u003eFuse – 5 pcs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e840k6\" data-start=\"5824\" data-end=\"5851\"\u003e\n\u003cp data-start=\"5826\" data-end=\"5851\"\u003eOperation Manual – 1 pc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5853\" data-end=\"5915\"\u003eOptional copper tubing induction coils available upon request.\u003c\/p\u003e\n\u003chr data-start=\"5917\" data-end=\"5920\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5922\" data-end=\"5932\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5934\" data-end=\"5968\"\u003e\u003cstrong data-start=\"5934\" data-end=\"5968\"\u003eManufacturer Warranty Included\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282677985602,"sku":null,"price":9990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ih35ab_black_1.jpg?v=1773594018","url":"https:\/\/summitsupplydirect.com\/products\/across-international-ih35ab-35kw-mid-frequency-split-induction-heater-w-timers-30-80khz","provider":"Summit Supply Direct","version":"1.0","type":"link"}