{"product_id":"across-international-bc-6f-110-nsf-certified-6-ft-class-ii-type-a2-biosafety-cabinet","title":"Across International BC-6F.110 NSF Certified 6 Ft Class II Type A2 Biosafety Cabinet","description":"\u003ch2 data-section-id=\"14w4ast\" data-start=\"388\" data-end=\"482\"\u003eNSF Certified 6 Ft Biological Safety Cabinet for Laboratory Containment \u0026amp; Pathogen Handling\u003c\/h2\u003e\n\u003cp data-start=\"484\" data-end=\"734\"\u003eThe \u003cstrong data-start=\"488\" data-end=\"540\"\u003eAi BC-6F 6 Ft Class II Type A2 Biosafety Cabinet\u003c\/strong\u003e is a \u003cstrong data-start=\"546\" data-end=\"597\"\u003eNSF\/ANSI 49 certified biological safety cabinet\u003c\/strong\u003e designed to safely handle biological materials while protecting laboratory personnel, research samples, and the surrounding environment.\u003c\/p\u003e\n\u003cp data-start=\"736\" data-end=\"1030\"\u003eA \u003cstrong data-start=\"738\" data-end=\"765\"\u003ebiosafety cabinet (BSC)\u003c\/strong\u003e—also referred to as a \u003cstrong data-start=\"788\" data-end=\"851\"\u003ebiological safety cabinet or microbiological safety cabinet\u003c\/strong\u003e—is an enclosed, ventilated laboratory workstation used when working with materials contaminated with or potentially contaminated by pathogens requiring a defined biosafety level.\u003c\/p\u003e\n\u003cp data-start=\"1032\" data-end=\"1359\"\u003eThe primary purpose of a biosafety cabinet is to \u003cstrong data-start=\"1081\" data-end=\"1122\"\u003eprevent exposure to infectious agents\u003c\/strong\u003e while maintaining sterile conditions for laboratory procedures. The \u003cstrong data-start=\"1191\" data-end=\"1275\"\u003eAi Class II Type A2 cabinet uses advanced HEPA filtration and controlled airflow\u003c\/strong\u003e to remove harmful bacteria, viruses, and particulates before air exits the cabinet.\u003c\/p\u003e\n\u003cp data-start=\"1361\" data-end=\"1665\"\u003eUnlike laminar flow clean benches that blow unfiltered air toward the user, this \u003cstrong data-start=\"1442\" data-end=\"1517\"\u003eClass II biosafety cabinet filters all exhaust air through HEPA filters\u003c\/strong\u003e, making it ideal for \u003cstrong data-start=\"1539\" data-end=\"1664\"\u003emicrobiology research, pharmaceutical laboratories, virology testing, vaccine development, and COVID-19 specimen handling\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1667\" data-end=\"1670\"\u003e\n\u003ch1 data-section-id=\"nms9yd\" data-start=\"1672\" data-end=\"1731\"\u003eKey Features of the Ai Class II Type A2 Biosafety Cabinet\u003c\/h1\u003e\n\u003ch3 data-section-id=\"15argzx\" data-start=\"1733\" data-end=\"1758\"\u003eNSF\/ANSI 49 Certified\u003c\/h3\u003e\n\u003cp data-start=\"1759\" data-end=\"1850\"\u003eMeets \u003cstrong data-start=\"1765\" data-end=\"1812\"\u003eNSF\/ANSI Standard 49 biosafety requirements\u003c\/strong\u003e for laboratory containment equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"lsgott\" data-start=\"1852\" data-end=\"1906\"\u003eDesigned for Pathogen \u0026amp; COVID-19 Specimen Handling\u003c\/h3\u003e\n\u003cp data-start=\"1907\" data-end=\"2027\"\u003eProvides a safe environment for laboratories working with \u003cstrong data-start=\"1965\" data-end=\"2026\"\u003ebiological samples, viral cultures, and infectious agents\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4s51tn\" data-start=\"2029\" data-end=\"2060\"\u003eDual HEPA Filtration System\u003c\/h3\u003e\n\u003cp data-start=\"2061\" data-end=\"2191\"\u003eTwo \u003cstrong data-start=\"2065\" data-end=\"2131\"\u003ehigh-efficiency HEPA filters with 99.999% efficiency at 0.3 μm\u003c\/strong\u003e capture airborne contaminants and maintain sterile airflow.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19o8aph\" data-start=\"2193\" data-end=\"2233\"\u003eMotorized Front Glass Viewing Window\u003c\/h3\u003e\n\u003cp data-start=\"2234\" data-end=\"2349\"\u003eTempered safety glass panel with \u003cstrong data-start=\"2267\" data-end=\"2324\"\u003emotorized adjustment and optional foot switch control\u003c\/strong\u003e for ergonomic operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qbftwb\" data-start=\"2351\" data-end=\"2378\"\u003eUV Sterilization System\u003c\/h3\u003e\n\u003cp data-start=\"2379\" data-end=\"2483\"\u003eIntegrated \u003cstrong data-start=\"2390\" data-end=\"2427\"\u003e30W germicidal UV lamp (253.7 nm)\u003c\/strong\u003e disinfects the chamber before and after laboratory use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zwntv5\" data-start=\"2485\" data-end=\"2519\"\u003eAdvanced LCD Control Interface\u003c\/h3\u003e\n\u003cp data-start=\"2520\" data-end=\"2635\"\u003eLarge \u003cstrong data-start=\"2526\" data-end=\"2595\"\u003eLCD display with soft-touch controls and remote control operation\u003c\/strong\u003e for monitoring airflow and filter life.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5os22n\" data-start=\"2637\" data-end=\"2669\"\u003eAutomatic Airflow Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"2670\" data-end=\"2785\"\u003eAutomatic airflow speed control with alarms for \u003cstrong data-start=\"2718\" data-end=\"2784\"\u003eabnormal airflow, filter replacement, and unsafe window height\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o91pw4\" data-start=\"2787\" data-end=\"2825\"\u003eStainless Steel Laboratory Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2826\" data-end=\"2930\"\u003eInterior \u003cstrong data-start=\"2835\" data-end=\"2866\"\u003e304 stainless steel chamber\u003c\/strong\u003e provides durability, corrosion resistance, and easy sanitation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16u4rhz\" data-start=\"2932\" data-end=\"2956\"\u003eIntegrated Utilities\u003c\/h3\u003e\n\u003cp data-start=\"2957\" data-end=\"3076\"\u003eBuilt-in \u003cstrong data-start=\"2966\" data-end=\"3038\"\u003ewater port, gas port, electrical outlets, and hanging bar with hooks\u003c\/strong\u003e for convenient laboratory operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ssc6lj\" data-start=\"3078\" data-end=\"3105\"\u003eEasy Maintenance Design\u003c\/h3\u003e\n\u003cp data-start=\"3106\" data-end=\"3186\"\u003e\u003cstrong data-start=\"3106\" data-end=\"3140\"\u003ePneumatic front panel supports\u003c\/strong\u003e allow easy cabinet servicing and maintenance.\u003c\/p\u003e\n\u003chr data-start=\"3188\" data-end=\"3191\"\u003e\n\u003ch1 data-section-id=\"9ocsyr\" data-start=\"3193\" data-end=\"3240\"\u003eWhat Is a Class II Type A2 Biosafety Cabinet?\u003c\/h1\u003e\n\u003cp data-start=\"3242\" data-end=\"3292\"\u003eA \u003cstrong data-start=\"3244\" data-end=\"3282\"\u003eClass II Type A2 biosafety cabinet\u003c\/strong\u003e protects:\u003c\/p\u003e\n\u003cp data-start=\"3294\" data-end=\"3414\"\u003e• \u003cstrong data-start=\"3296\" data-end=\"3320\"\u003eLaboratory personnel\u003c\/strong\u003e\u003cbr data-start=\"3320\" data-end=\"3323\"\u003e• \u003cstrong data-start=\"3325\" data-end=\"3367\"\u003eThe surrounding laboratory environment\u003c\/strong\u003e\u003cbr data-start=\"3367\" data-end=\"3370\"\u003e• \u003cstrong data-start=\"3372\" data-end=\"3414\"\u003eThe sterility of samples being handled\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3416\" data-end=\"3560\"\u003eAir enters through the front opening, creating a \u003cstrong data-start=\"3465\" data-end=\"3502\"\u003eprotective inward airflow barrier\u003c\/strong\u003e that prevents contaminated air from escaping the cabinet.\u003c\/p\u003e\n\u003cp data-start=\"3562\" data-end=\"3596\"\u003eInside the cabinet airflow system:\u003c\/p\u003e\n\u003cul data-start=\"3598\" data-end=\"3695\"\u003e\n\u003cli data-section-id=\"1f3k60m\" data-start=\"3598\" data-end=\"3651\"\u003e\n\u003cp data-start=\"3600\" data-end=\"3651\"\u003e\u003cstrong data-start=\"3600\" data-end=\"3651\"\u003e70% of air is recirculated through HEPA filters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rd1yyb\" data-start=\"3652\" data-end=\"3695\"\u003e\n\u003cp data-start=\"3654\" data-end=\"3695\"\u003e\u003cstrong data-start=\"3654\" data-end=\"3695\"\u003e30% is exhausted through the top vent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3697\" data-end=\"3880\"\u003eBecause of this design, \u003cstrong data-start=\"3721\" data-end=\"3811\"\u003eType A2 cabinets represent approximately 90% of biosafety cabinets installed worldwide\u003c\/strong\u003e, making them the most commonly used biosafety cabinet configuration.\u003c\/p\u003e\n\u003chr data-start=\"3882\" data-end=\"3885\"\u003e\n\u003ch1 data-section-id=\"1baxwhi\" data-start=\"3887\" data-end=\"3908\"\u003eOperating Procedure\u003c\/h1\u003e\n\u003ch3 data-section-id=\"18w7ypo\" data-start=\"3910\" data-end=\"3924\"\u003eBefore Use\u003c\/h3\u003e\n\u003col data-start=\"3926\" data-end=\"4211\"\u003e\n\u003cli data-section-id=\"l7xgzw\" data-start=\"3926\" data-end=\"3963\"\u003e\n\u003cp data-start=\"3929\" data-end=\"3963\"\u003eFully close the front glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cf8y1g\" data-start=\"3964\" data-end=\"4022\"\u003e\n\u003cp data-start=\"3967\" data-end=\"4022\"\u003eActivate the \u003cstrong data-start=\"3980\" data-end=\"4021\"\u003eUV sterilization light for 30 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aysqvu\" data-start=\"4023\" data-end=\"4072\"\u003e\n\u003cp data-start=\"4026\" data-end=\"4072\"\u003eLeave the room during the sterilization cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17om5ol\" data-start=\"4073\" data-end=\"4138\"\u003e\n\u003cp data-start=\"4076\" data-end=\"4138\"\u003eRaise the front glass panel to the recommended opening height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ezz6q5\" data-start=\"4139\" data-end=\"4211\"\u003e\n\u003cp data-start=\"4142\" data-end=\"4211\"\u003eTurn on airflow circulation for \u003cstrong data-start=\"4174\" data-end=\"4210\"\u003e10 minutes before beginning work\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-section-id=\"qz8j6p\" data-start=\"4213\" data-end=\"4226\"\u003eAfter Use\u003c\/h3\u003e\n\u003col data-start=\"4228\" data-end=\"4331\"\u003e\n\u003cli data-section-id=\"18uhkfh\" data-start=\"4228\" data-end=\"4259\"\u003e\n\u003cp data-start=\"4231\" data-end=\"4259\"\u003eFully close the glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15nh12z\" data-start=\"4260\" data-end=\"4331\"\u003e\n\u003cp data-start=\"4263\" data-end=\"4331\"\u003eTurn on the \u003cstrong data-start=\"4275\" data-end=\"4310\"\u003eUV light for another 30 minutes\u003c\/strong\u003e for decontamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"4333\" data-end=\"4336\"\u003e\n\u003ch1 data-section-id=\"1nileve\" data-start=\"4338\" data-end=\"4374\"\u003eBiosafety Cabinet Usage Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"4376\" data-end=\"4418\"\u003eTo maintain proper containment and safety:\u003c\/p\u003e\n\u003cp data-start=\"4420\" data-end=\"4732\"\u003e• Do \u003cstrong data-start=\"4425\" data-end=\"4469\"\u003enot use flammable or explosive materials\u003c\/strong\u003e inside the cabinet\u003cbr data-start=\"4488\" data-end=\"4491\"\u003e• Avoid \u003cstrong data-start=\"4499\" data-end=\"4552\"\u003evolatile chemicals that could damage HEPA filters\u003c\/strong\u003e\u003cbr data-start=\"4552\" data-end=\"4555\"\u003e• Do \u003cstrong data-start=\"4560\" data-end=\"4597\"\u003enot release toxic chemical vapors\u003c\/strong\u003e into the cabinet\u003cbr data-start=\"4614\" data-end=\"4617\"\u003e• \u003cstrong data-start=\"4619\" data-end=\"4649\"\u003eOpen flames are prohibited\u003c\/strong\u003e as they disrupt airflow patterns\u003cbr data-start=\"4682\" data-end=\"4685\"\u003e• Use \u003cstrong data-start=\"4691\" data-end=\"4722\"\u003e≤10 mL disinfectant alcohol\u003c\/strong\u003e if needed\u003c\/p\u003e\n\u003cp data-start=\"4734\" data-end=\"4768\"\u003eRecommended disinfectants include:\u003c\/p\u003e\n\u003cul data-start=\"4770\" data-end=\"4910\"\u003e\n\u003cli data-section-id=\"411yfh\" data-start=\"4770\" data-end=\"4800\"\u003e\n\u003cp data-start=\"4772\" data-end=\"4800\"\u003eSodium hypochlorite (bleach)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1016zl5\" data-start=\"4801\" data-end=\"4824\"\u003e\n\u003cp data-start=\"4803\" data-end=\"4824\"\u003eIodophors (Wescodyne)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vstz3d\" data-start=\"4825\" data-end=\"4856\"\u003e\n\u003cp data-start=\"4827\" data-end=\"4856\"\u003ePhenolics (Hilphene, Vespene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wzl42d\" data-start=\"4857\" data-end=\"4910\"\u003e\n\u003cp data-start=\"4859\" data-end=\"4910\"\u003eQuaternary ammonium compounds (Conflikt, Endbac II)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4912\" data-end=\"4915\"\u003e\n\u003ch1 data-section-id=\"hj61r4\" data-start=\"4917\" data-end=\"4938\"\u003eInstallation Notice\u003c\/h1\u003e\n\u003cp data-start=\"4940\" data-end=\"5014\"\u003e⚠ \u003cstrong data-start=\"4942\" data-end=\"5014\"\u003eInstallation requires a forklift or crane due to the cabinet weight.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5016\" data-end=\"5019\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5021\" data-end=\"5047\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5049\" data-end=\"5057\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5058\" data-end=\"5063\"\u003eBC-6F\u003c\/p\u003e\n\u003chr data-start=\"5065\" data-end=\"5068\"\u003e\n\u003ch1 data-section-id=\"1pvd1l0\" data-start=\"5070\" data-end=\"5095\"\u003eElectrical Requirements\u003c\/h1\u003e\n\u003cul data-start=\"5097\" data-end=\"5143\"\u003e\n\u003cli data-section-id=\"vl7nf3\" data-start=\"5097\" data-end=\"5127\"\u003e\n\u003cp data-start=\"5099\" data-end=\"5127\"\u003e\u003cstrong data-start=\"5099\" data-end=\"5127\"\u003e110V, 60Hz, Single Phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o58me0\" data-start=\"5128\" data-end=\"5143\"\u003e\n\u003cp data-start=\"5130\" data-end=\"5143\"\u003e\u003cstrong data-start=\"5130\" data-end=\"5143\"\u003e500 Watts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5145\" data-end=\"5148\"\u003e\n\u003ch1 data-section-id=\"zba58a\" data-start=\"5150\" data-end=\"5174\"\u003eChamber Specifications\u003c\/h1\u003e\n\u003cp data-start=\"5176\" data-end=\"5187\"\u003eDimensions:\u003c\/p\u003e\n\u003cp data-start=\"5189\" data-end=\"5222\"\u003e\u003cstrong data-start=\"5189\" data-end=\"5222\"\u003e67 × 23.5 × 26 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5224\" data-end=\"5233\"\u003eMaterial:\u003c\/p\u003e\n\u003cp data-start=\"5235\" data-end=\"5258\"\u003e\u003cstrong data-start=\"5235\" data-end=\"5258\"\u003e304 Stainless Steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5260\" data-end=\"5269\"\u003eFeatures:\u003c\/p\u003e\n\u003cul data-start=\"5271\" data-end=\"5497\"\u003e\n\u003cli data-section-id=\"1ctkx66\" data-start=\"5271\" data-end=\"5313\"\u003e\n\u003cp data-start=\"5273\" data-end=\"5313\"\u003eFour internal power outlets (\u0026lt;500W each)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ixfs3r\" data-start=\"5314\" data-end=\"5344\"\u003e\n\u003cp data-start=\"5316\" data-end=\"5344\"\u003eStainless steel \u003cstrong data-start=\"5332\" data-end=\"5344\"\u003egas port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1998ep3\" data-start=\"5345\" data-end=\"5377\"\u003e\n\u003cp data-start=\"5347\" data-end=\"5377\"\u003eStainless steel \u003cstrong data-start=\"5363\" data-end=\"5377\"\u003ewater port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"km7pk9\" data-start=\"5378\" data-end=\"5425\"\u003e\n\u003cp data-start=\"5380\" data-end=\"5425\"\u003eStainless steel hanging bar with \u003cstrong data-start=\"5413\" data-end=\"5425\"\u003e10 hooks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5fk0xi\" data-start=\"5426\" data-end=\"5466\"\u003e\n\u003cp data-start=\"5428\" data-end=\"5466\"\u003eRemovable stainless steel work surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15ticne\" data-start=\"5467\" data-end=\"5497\"\u003e\n\u003cp data-start=\"5469\" data-end=\"5497\"\u003e\u003cstrong data-start=\"5469\" data-end=\"5497\"\u003e29.5 in ground clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5499\" data-end=\"5502\"\u003e\n\u003ch1 data-section-id=\"1sqsjx9\" data-start=\"5504\" data-end=\"5521\"\u003eLighting System\u003c\/h1\u003e\n\u003cp data-start=\"5523\" data-end=\"5536\"\u003eLED Lighting:\u003c\/p\u003e\n\u003cul data-start=\"5538\" data-end=\"5574\"\u003e\n\u003cli data-section-id=\"bcsdzu\" data-start=\"5538\" data-end=\"5551\"\u003e\n\u003cp data-start=\"5540\" data-end=\"5551\"\u003e\u003cstrong data-start=\"5540\" data-end=\"5551\"\u003e2 × 22W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x6abrz\" data-start=\"5552\" data-end=\"5574\"\u003e\n\u003cblockquote data-start=\"5554\" data-end=\"5574\"\u003e\n\u003cp data-start=\"5555\" data-end=\"5574\"\u003e1000 Lux brightness\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5576\" data-end=\"5593\"\u003eUV Sterilization:\u003c\/p\u003e\n\u003cul data-start=\"5595\" data-end=\"5700\"\u003e\n\u003cli data-section-id=\"yvinug\" data-start=\"5595\" data-end=\"5623\"\u003e\n\u003cp data-start=\"5597\" data-end=\"5623\"\u003e\u003cstrong data-start=\"5597\" data-end=\"5623\"\u003e30W germicidal UV lamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q9ul45\" data-start=\"5624\" data-end=\"5650\"\u003e\n\u003cp data-start=\"5626\" data-end=\"5650\"\u003eWavelength: \u003cstrong data-start=\"5638\" data-end=\"5650\"\u003e253.7 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6hoqr\" data-start=\"5651\" data-end=\"5700\"\u003e\n\u003cp data-start=\"5653\" data-end=\"5700\"\u003eRecommended replacement interval: \u003cstrong data-start=\"5687\" data-end=\"5700\"\u003e600 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5702\" data-end=\"5705\"\u003e\n\u003ch1 data-section-id=\"16sr3qu\" data-start=\"5707\" data-end=\"5728\"\u003eAirflow Performance\u003c\/h1\u003e\n\u003cp data-start=\"5730\" data-end=\"5745\"\u003eAirflow Volume:\u003c\/p\u003e\n\u003cul data-start=\"5747\" data-end=\"5815\"\u003e\n\u003cli data-section-id=\"2r0434\" data-start=\"5747\" data-end=\"5768\"\u003e\n\u003cp data-start=\"5749\" data-end=\"5768\"\u003eInflow: \u003cstrong data-start=\"5757\" data-end=\"5768\"\u003e825 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p8nl64\" data-start=\"5769\" data-end=\"5792\"\u003e\n\u003cp data-start=\"5771\" data-end=\"5792\"\u003eDownflow: \u003cstrong data-start=\"5781\" data-end=\"5792\"\u003e710 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xryz39\" data-start=\"5793\" data-end=\"5815\"\u003e\n\u003cp data-start=\"5795\" data-end=\"5815\"\u003eExhaust: \u003cstrong data-start=\"5804\" data-end=\"5815\"\u003e485 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5817\" data-end=\"5831\"\u003eAirflow Speed:\u003c\/p\u003e\n\u003cul data-start=\"5833\" data-end=\"5884\"\u003e\n\u003cli data-section-id=\"j1kzym\" data-start=\"5833\" data-end=\"5858\"\u003e\n\u003cp data-start=\"5835\" data-end=\"5858\"\u003eInflow: \u003cstrong data-start=\"5843\" data-end=\"5858\"\u003e100–110 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sazy3f\" data-start=\"5859\" data-end=\"5884\"\u003e\n\u003cp data-start=\"5861\" data-end=\"5884\"\u003eDownflow: \u003cstrong data-start=\"5871\" data-end=\"5884\"\u003e60–70 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5886\" data-end=\"5907\"\u003eAirflow distribution:\u003c\/p\u003e\n\u003cul data-start=\"5909\" data-end=\"5979\"\u003e\n\u003cli data-section-id=\"bak7jt\" data-start=\"5909\" data-end=\"5942\"\u003e\n\u003cp data-start=\"5911\" data-end=\"5942\"\u003e\u003cstrong data-start=\"5911\" data-end=\"5942\"\u003e70% recirculated internally\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"103tb0w\" data-start=\"5943\" data-end=\"5979\"\u003e\n\u003cp data-start=\"5945\" data-end=\"5979\"\u003e\u003cstrong data-start=\"5945\" data-end=\"5979\"\u003e30% exhausted through top vent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5981\" data-end=\"6007\"\u003eRecommended top clearance:\u003c\/p\u003e\n\u003cp data-start=\"6009\" data-end=\"6022\"\u003e\u003cstrong data-start=\"6009\" data-end=\"6022\"\u003e12 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6024\" data-end=\"6027\"\u003e\n\u003ch1 data-section-id=\"ru67nm\" data-start=\"6029\" data-end=\"6046\"\u003eHEPA Filtration\u003c\/h1\u003e\n\u003cul data-start=\"6048\" data-end=\"6198\"\u003e\n\u003cli data-section-id=\"g8fg3v\" data-start=\"6048\" data-end=\"6066\"\u003e\n\u003cp data-start=\"6050\" data-end=\"6066\"\u003eTwo HEPA filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cipdus\" data-start=\"6067\" data-end=\"6101\"\u003e\n\u003cp data-start=\"6069\" data-end=\"6101\"\u003e\u003cstrong data-start=\"6069\" data-end=\"6101\"\u003e99.999% efficiency at 0.3 μm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1auxu81\" data-start=\"6102\" data-end=\"6146\"\u003e\n\u003cp data-start=\"6104\" data-end=\"6146\"\u003eFilter life indicator with hour monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pyccd9\" data-start=\"6147\" data-end=\"6198\"\u003e\n\u003cp data-start=\"6149\" data-end=\"6198\"\u003eRecommended replacement interval: \u003cstrong data-start=\"6183\" data-end=\"6198\"\u003e4,000 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6200\" data-end=\"6203\"\u003e\n\u003ch1 data-section-id=\"17x59vr\" data-start=\"6205\" data-end=\"6231\"\u003eFront Safety Glass Panel\u003c\/h1\u003e\n\u003cp data-start=\"6233\" data-end=\"6242\"\u003eMaterial:\u003c\/p\u003e\n\u003cul data-start=\"6244\" data-end=\"6324\"\u003e\n\u003cli data-section-id=\"69fw2t\" data-start=\"6244\" data-end=\"6288\"\u003e\n\u003cp data-start=\"6246\" data-end=\"6288\"\u003eDual-layer laminated tempered safety glass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rqbpo5\" data-start=\"6289\" data-end=\"6310\"\u003e\n\u003cp data-start=\"6291\" data-end=\"6310\"\u003eThickness \u003cstrong data-start=\"6301\" data-end=\"6310\"\u003e\u0026gt;5 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9rz3gi\" data-start=\"6311\" data-end=\"6324\"\u003e\n\u003cp data-start=\"6313\" data-end=\"6324\"\u003eUV blocking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6326\" data-end=\"6342\"\u003eOpening heights:\u003c\/p\u003e\n\u003cul data-start=\"6344\" data-end=\"6415\"\u003e\n\u003cli data-section-id=\"1hi92q0\" data-start=\"6344\" data-end=\"6380\"\u003e\n\u003cp data-start=\"6346\" data-end=\"6380\"\u003eRecommended opening: \u003cstrong data-start=\"6367\" data-end=\"6380\"\u003e10 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a9l759\" data-start=\"6381\" data-end=\"6415\"\u003e\n\u003cp data-start=\"6383\" data-end=\"6415\"\u003eMaximum opening: \u003cstrong data-start=\"6400\" data-end=\"6415\"\u003e20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6417\" data-end=\"6420\"\u003e\n\u003ch1 data-section-id=\"jrwzgb\" data-start=\"6422\" data-end=\"6436\"\u003eConstruction\u003c\/h1\u003e\n\u003cp data-start=\"6438\" data-end=\"6446\"\u003eChamber:\u003c\/p\u003e\n\u003cp data-start=\"6448\" data-end=\"6471\"\u003e\u003cstrong data-start=\"6448\" data-end=\"6471\"\u003e304 stainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6473\" data-end=\"6490\"\u003eExterior cabinet:\u003c\/p\u003e\n\u003cp data-start=\"6492\" data-end=\"6515\"\u003e\u003cstrong data-start=\"6492\" data-end=\"6515\"\u003ePowder-coated steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6517\" data-end=\"6525\"\u003eCasters:\u003c\/p\u003e\n\u003cp data-start=\"6527\" data-end=\"6565\"\u003eFour casters with \u003cstrong data-start=\"6545\" data-end=\"6565\"\u003estabilizing feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6567\" data-end=\"6570\"\u003e\n\u003ch1 data-section-id=\"e0illa\" data-start=\"6572\" data-end=\"6585\"\u003eNoise Level\u003c\/h1\u003e\n\u003cp data-start=\"6587\" data-end=\"6601\"\u003e\u003cstrong data-start=\"6587\" data-end=\"6601\"\u003e\u0026lt; 65 dB(A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6603\" data-end=\"6606\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6608\" data-end=\"6629\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6631\" data-end=\"6643\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"6645\" data-end=\"6656\"\u003e\u003cstrong data-start=\"6645\" data-end=\"6656\"\u003e820 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6658\" data-end=\"6674\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"6676\" data-end=\"6687\"\u003e\u003cstrong data-start=\"6676\" data-end=\"6687\"\u003e952 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6689\" data-end=\"6705\"\u003eFully assembled:\u003c\/p\u003e\n\u003cp data-start=\"6707\" data-end=\"6744\"\u003e\u003cstrong data-start=\"6707\" data-end=\"6744\"\u003e73.5 × 30.5 × 90.5 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6746\" data-end=\"6760\"\u003eWithout stand:\u003c\/p\u003e\n\u003cp data-start=\"6762\" data-end=\"6787\"\u003e\u003cstrong data-start=\"6762\" data-end=\"6787\"\u003e73.5 × 30.5 × 63.5 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6789\" data-end=\"6809\"\u003eShipping dimensions:\u003c\/p\u003e\n\u003cp data-start=\"6811\" data-end=\"6834\"\u003e\u003cstrong data-start=\"6811\" data-end=\"6834\"\u003e79.5 × 42.5 × 75 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6836\" data-end=\"6839\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"6841\" data-end=\"6858\"\u003eSafety Features\u003c\/h1\u003e\n\u003cul data-start=\"6860\" data-end=\"6945\"\u003e\n\u003cli data-section-id=\"okczb7\" data-start=\"6860\" data-end=\"6884\"\u003e\n\u003cp data-start=\"6862\" data-end=\"6884\"\u003eAbnormal airflow alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"79k0g5\" data-start=\"6885\" data-end=\"6911\"\u003e\n\u003cp data-start=\"6887\" data-end=\"6911\"\u003eFilter replacement alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1imewzp\" data-start=\"6912\" data-end=\"6945\"\u003e\n\u003cp data-start=\"6914\" data-end=\"6945\"\u003eUnsafe front glass height alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6947\" data-end=\"6950\"\u003e\n\u003ch1 data-section-id=\"gk6d0t\" data-start=\"6952\" data-end=\"6968\"\u003eCertifications\u003c\/h1\u003e\n\u003cp data-start=\"6970\" data-end=\"7006\"\u003e\u003cstrong data-start=\"6970\" data-end=\"7006\"\u003eNSF\/ANSI 49 Certified (C0559576)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7008\" data-end=\"7011\"\u003e\n\u003ch1 data-section-id=\"1mk6eig\" data-start=\"7013\" data-end=\"7035\"\u003eIncluded Accessories\u003c\/h1\u003e\n\u003cul data-start=\"7037\" data-end=\"7354\"\u003e\n\u003cli data-section-id=\"rcig22\" data-start=\"7037\" data-end=\"7064\"\u003e\n\u003cp data-start=\"7039\" data-end=\"7064\"\u003eAi 6 Ft Biosafety Cabinet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r26xrp\" data-start=\"7065\" data-end=\"7090\"\u003e\n\u003cp data-start=\"7067\" data-end=\"7090\"\u003eDetachable armrests (4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mecryh\" data-start=\"7091\" data-end=\"7111\"\u003e\n\u003cp data-start=\"7093\" data-end=\"7111\"\u003eOn\/off foot switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lj6d2j\" data-start=\"7112\" data-end=\"7128\"\u003e\n\u003cp data-start=\"7114\" data-end=\"7128\"\u003eRemote control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ebodao\" data-start=\"7129\" data-end=\"7157\"\u003e\n\u003cp data-start=\"7131\" data-end=\"7157\"\u003eBottom drain port assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1npt8xp\" data-start=\"7158\" data-end=\"7180\"\u003e\n\u003cp data-start=\"7160\" data-end=\"7180\"\u003eBackup UV light tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vt82d4\" data-start=\"7181\" data-end=\"7193\"\u003e\n\u003cp data-start=\"7183\" data-end=\"7193\"\u003eHex wrench\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"48e0v7\" data-start=\"7194\" data-end=\"7223\"\u003e\n\u003cp data-start=\"7196\" data-end=\"7223\"\u003eGlass panel adjustment tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xbxkhn\" data-start=\"7224\" data-end=\"7249\"\u003e\n\u003cp data-start=\"7226\" data-end=\"7249\"\u003eControl board fuses (9)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qpk6kt\" data-start=\"7250\" data-end=\"7265\"\u003e\n\u003cp data-start=\"7252\" data-end=\"7265\"\u003eHex bolts (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n5o9at\" data-start=\"7266\" data-end=\"7283\"\u003e\n\u003cp data-start=\"7268\" data-end=\"7283\"\u003eWasher sets (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tu4qog\" data-start=\"7284\" data-end=\"7310\"\u003e\n\u003cp data-start=\"7286\" data-end=\"7310\"\u003eStandard 110V power cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1islffd\" data-start=\"7311\" data-end=\"7340\"\u003e\n\u003cp data-start=\"7313\" data-end=\"7340\"\u003eStand assembly with casters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"7341\" data-end=\"7354\"\u003e\n\u003cp data-start=\"7343\" data-end=\"7354\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7356\" data-end=\"7359\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7361\" data-end=\"7371\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7373\" data-end=\"7405\"\u003e\u003cstrong data-start=\"7373\" data-end=\"7405\"\u003e1 Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282493206850,"sku":null,"price":9590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/bc-6f1.webp?v=1773585297","url":"https:\/\/summitsupplydirect.com\/products\/across-international-bc-6f-110-nsf-certified-6-ft-class-ii-type-a2-biosafety-cabinet","provider":"Summit Supply Direct","version":"1.0","type":"link"}