{"product_id":"across-international-bc-4f-110-nsf-certified-4-ft-class-ii-type-a2-biosafety-cabinet","title":"Across International BC-4F.110 NSF Certified 4 Ft Class II Type A2 Biosafety Cabinet","description":"\u003ch2 data-section-id=\"pocv6f\" data-start=\"388\" data-end=\"465\"\u003eProfessional Class II Biological Safety Cabinet for Laboratory Containment\u003c\/h2\u003e\n\u003cp data-start=\"467\" data-end=\"759\"\u003eThe \u003cstrong data-start=\"471\" data-end=\"523\"\u003eAi BC-4F 4 Ft Class II Type A2 Biosafety Cabinet\u003c\/strong\u003e is a \u003cstrong data-start=\"529\" data-end=\"580\"\u003eNSF\/ANSI 49 certified biological safety cabinet\u003c\/strong\u003e designed to provide maximum protection for laboratory personnel, sensitive samples, and the surrounding environment when working with potentially infectious biological materials.\u003c\/p\u003e\n\u003cp data-start=\"761\" data-end=\"995\"\u003eA \u003cstrong data-start=\"763\" data-end=\"790\"\u003ebiosafety cabinet (BSC)\u003c\/strong\u003e—also known as a \u003cstrong data-start=\"807\" data-end=\"870\"\u003ebiological safety cabinet or microbiological safety cabinet\u003c\/strong\u003e—is an enclosed, ventilated laboratory workstation used for safely handling pathogens that require a defined biosafety level.\u003c\/p\u003e\n\u003cp data-start=\"997\" data-end=\"1359\"\u003eThis \u003cstrong data-start=\"1002\" data-end=\"1040\"\u003eClass II Type A2 biosafety cabinet\u003c\/strong\u003e uses \u003cstrong data-start=\"1046\" data-end=\"1101\"\u003edual HEPA filtration and controlled laminar airflow\u003c\/strong\u003e to maintain a sterile working environment while preventing contaminated air from escaping into the laboratory. It is ideal for laboratories performing \u003cstrong data-start=\"1253\" data-end=\"1358\"\u003emicrobiology, virology, pharmaceutical research, clinical diagnostics, and COVID-19 specimen handling\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1361\" data-end=\"1586\"\u003eUnlike laminar flow clean benches that blow unfiltered air toward the user, the \u003cstrong data-start=\"1441\" data-end=\"1494\"\u003eAi biosafety cabinet HEPA-filters all exhaust air\u003c\/strong\u003e, capturing bacteria, viruses, and other harmful particles before the air exits the cabinet.\u003c\/p\u003e\n\u003chr data-start=\"1588\" data-end=\"1591\"\u003e\n\u003ch1 data-section-id=\"nms9yd\" data-start=\"1593\" data-end=\"1652\"\u003eKey Features of the Ai Class II Type A2 Biosafety Cabinet\u003c\/h1\u003e\n\u003ch3 data-section-id=\"15argzx\" data-start=\"1654\" data-end=\"1679\"\u003eNSF\/ANSI 49 Certified\u003c\/h3\u003e\n\u003cp data-start=\"1680\" data-end=\"1779\"\u003eCertified to \u003cstrong data-start=\"1693\" data-end=\"1717\"\u003eNSF\/ANSI Standard 49\u003c\/strong\u003e, ensuring compliance with biosafety containment requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19rbwpu\" data-start=\"1781\" data-end=\"1832\"\u003eIdeal for Biological \u0026amp; COVID-19 Sample Handling\u003c\/h3\u003e\n\u003cp data-start=\"1833\" data-end=\"1920\"\u003eDesigned for safe work with \u003cstrong data-start=\"1861\" data-end=\"1919\"\u003epathogens, microbiological cultures, and viral samples\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4s51tn\" data-start=\"1922\" data-end=\"1953\"\u003eDual HEPA Filtration System\u003c\/h3\u003e\n\u003cp data-start=\"1954\" data-end=\"2077\"\u003eTwo \u003cstrong data-start=\"1958\" data-end=\"2008\"\u003eHEPA filters with 99.999% efficiency at 0.3 μm\u003c\/strong\u003e capture airborne contaminants to protect both personnel and samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19o8aph\" data-start=\"2079\" data-end=\"2119\"\u003eMotorized Front Glass Viewing Window\u003c\/h3\u003e\n\u003cp data-start=\"2120\" data-end=\"2231\"\u003eTempered safety glass window with \u003cstrong data-start=\"2154\" data-end=\"2211\"\u003emotorized adjustment and optional foot switch control\u003c\/strong\u003e for safe operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qbftwb\" data-start=\"2233\" data-end=\"2260\"\u003eUV Sterilization System\u003c\/h3\u003e\n\u003cp data-start=\"2261\" data-end=\"2360\"\u003eBuilt-in \u003cstrong data-start=\"2270\" data-end=\"2307\"\u003e30W germicidal UV lamp (253.7 nm)\u003c\/strong\u003e disinfects the cabinet chamber before and after use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zwntv5\" data-start=\"2362\" data-end=\"2396\"\u003eAdvanced LCD Control Interface\u003c\/h3\u003e\n\u003cp data-start=\"2397\" data-end=\"2511\"\u003eLarge \u003cstrong data-start=\"2403\" data-end=\"2464\"\u003eLCD controller with soft-touch buttons and remote control\u003c\/strong\u003e allows easy monitoring of cabinet performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5os22n\" data-start=\"2513\" data-end=\"2545\"\u003eAutomatic Airflow Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"2546\" data-end=\"2660\"\u003eAutomatic flow speed adjustment with alarms for \u003cstrong data-start=\"2594\" data-end=\"2659\"\u003eabnormal airflow, filter replacement, and unsafe glass height\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"u4jnca\" data-start=\"2662\" data-end=\"2702\"\u003eStainless Steel Chamber Construction\u003c\/h3\u003e\n\u003cp data-start=\"2703\" data-end=\"2794\"\u003eInterior \u003cstrong data-start=\"2712\" data-end=\"2743\"\u003e304 stainless steel chamber\u003c\/strong\u003e provides corrosion resistance and easy sanitation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16u4rhz\" data-start=\"2796\" data-end=\"2820\"\u003eIntegrated Utilities\u003c\/h3\u003e\n\u003cp data-start=\"2821\" data-end=\"2928\"\u003eIncludes \u003cstrong data-start=\"2830\" data-end=\"2897\"\u003epower outlets, gas port, water port, and hanging bar with hooks\u003c\/strong\u003e for convenient lab operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dg7ob5\" data-start=\"2930\" data-end=\"2964\"\u003ePneumatic Front Panel Supports\u003c\/h3\u003e\n\u003cp data-start=\"2965\" data-end=\"3020\"\u003eAllows \u003cstrong data-start=\"2972\" data-end=\"3019\"\u003eeasy cabinet maintenance and service access\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3022\" data-end=\"3025\"\u003e\n\u003ch1 data-section-id=\"9ocsyr\" data-start=\"3027\" data-end=\"3074\"\u003eWhat Is a Class II Type A2 Biosafety Cabinet?\u003c\/h1\u003e\n\u003cp data-start=\"3076\" data-end=\"3133\"\u003eA \u003cstrong data-start=\"3078\" data-end=\"3108\"\u003eClass II biosafety cabinet\u003c\/strong\u003e provides protection for:\u003c\/p\u003e\n\u003cp data-start=\"3135\" data-end=\"3228\"\u003e• \u003cstrong data-start=\"3137\" data-end=\"3161\"\u003eLaboratory personnel\u003c\/strong\u003e\u003cbr data-start=\"3161\" data-end=\"3164\"\u003e• \u003cstrong data-start=\"3166\" data-end=\"3190\"\u003eEnvironmental safety\u003c\/strong\u003e\u003cbr data-start=\"3190\" data-end=\"3193\"\u003e• \u003cstrong data-start=\"3195\" data-end=\"3228\"\u003eSterility of research samples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3230\" data-end=\"3352\"\u003eAir enters through the front opening, creating an \u003cstrong data-start=\"3280\" data-end=\"3306\"\u003einward airflow barrier\u003c\/strong\u003e that prevents contaminated air from escaping.\u003c\/p\u003e\n\u003cp data-start=\"3354\" data-end=\"3373\"\u003eInside the cabinet:\u003c\/p\u003e\n\u003cul data-start=\"3375\" data-end=\"3472\"\u003e\n\u003cli data-section-id=\"1f3k60m\" data-start=\"3375\" data-end=\"3428\"\u003e\n\u003cp data-start=\"3377\" data-end=\"3428\"\u003e\u003cstrong data-start=\"3377\" data-end=\"3428\"\u003e70% of air is recirculated through HEPA filters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rd1yyb\" data-start=\"3429\" data-end=\"3472\"\u003e\n\u003cp data-start=\"3431\" data-end=\"3472\"\u003e\u003cstrong data-start=\"3431\" data-end=\"3472\"\u003e30% is exhausted through the top vent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3474\" data-end=\"3589\"\u003eThis airflow design maintains \u003cstrong data-start=\"3504\" data-end=\"3588\"\u003eclean, sterile conditions while safely containing hazardous biological materials\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3591\" data-end=\"3730\"\u003eApproximately \u003cstrong data-start=\"3605\" data-end=\"3675\"\u003e90% of biosafety cabinets installed worldwide are Type A2 cabinets\u003c\/strong\u003e, making them the most commonly used BSC configuration.\u003c\/p\u003e\n\u003chr data-start=\"3732\" data-end=\"3735\"\u003e\n\u003ch1 data-section-id=\"3kmtjk\" data-start=\"3737\" data-end=\"3768\"\u003eImportant Operating Procedure\u003c\/h1\u003e\n\u003ch3 data-section-id=\"18w7ypo\" data-start=\"3770\" data-end=\"3784\"\u003eBefore Use\u003c\/h3\u003e\n\u003col data-start=\"3786\" data-end=\"4069\"\u003e\n\u003cli data-section-id=\"l7xgzw\" data-start=\"3786\" data-end=\"3823\"\u003e\n\u003cp data-start=\"3789\" data-end=\"3823\"\u003eFully close the front glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nocar6\" data-start=\"3824\" data-end=\"3893\"\u003e\n\u003cp data-start=\"3827\" data-end=\"3893\"\u003eActivate the \u003cstrong data-start=\"3840\" data-end=\"3867\"\u003eUV light for 30 minutes\u003c\/strong\u003e to disinfect the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17j1e7k\" data-start=\"3894\" data-end=\"3936\"\u003e\n\u003cp data-start=\"3897\" data-end=\"3936\"\u003eLeave the room during UV sterilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19i4zap\" data-start=\"3937\" data-end=\"3996\"\u003e\n\u003cp data-start=\"3940\" data-end=\"3996\"\u003eRaise the glass panel to the recommended working height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ezz6q5\" data-start=\"3997\" data-end=\"4069\"\u003e\n\u003cp data-start=\"4000\" data-end=\"4069\"\u003eTurn on airflow circulation for \u003cstrong data-start=\"4032\" data-end=\"4068\"\u003e10 minutes before beginning work\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-section-id=\"qz8j6p\" data-start=\"4071\" data-end=\"4084\"\u003eAfter Use\u003c\/h3\u003e\n\u003col data-start=\"4086\" data-end=\"4185\"\u003e\n\u003cli data-section-id=\"18uhkfh\" data-start=\"4086\" data-end=\"4117\"\u003e\n\u003cp data-start=\"4089\" data-end=\"4117\"\u003eFully close the glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yb3we8\" data-start=\"4118\" data-end=\"4185\"\u003e\n\u003cp data-start=\"4121\" data-end=\"4185\"\u003eTurn on UV light for \u003cstrong data-start=\"4142\" data-end=\"4184\"\u003e30 minutes to complete decontamination\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"4187\" data-end=\"4190\"\u003e\n\u003ch1 data-section-id=\"1hjn8c3\" data-start=\"4192\" data-end=\"4229\"\u003eBiosafety Cabinet Safety Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"4231\" data-end=\"4250\"\u003eFor safe operation:\u003c\/p\u003e\n\u003cp data-start=\"4252\" data-end=\"4547\"\u003e• Do \u003cstrong data-start=\"4257\" data-end=\"4301\"\u003enot use flammable or explosive materials\u003c\/strong\u003e\u003cbr data-start=\"4301\" data-end=\"4304\"\u003e• Avoid \u003cstrong data-start=\"4312\" data-end=\"4363\"\u003evolatile chemicals that may damage HEPA filters\u003c\/strong\u003e\u003cbr data-start=\"4363\" data-end=\"4366\"\u003e• Do \u003cstrong data-start=\"4371\" data-end=\"4410\"\u003enot introduce toxic chemical vapors\u003c\/strong\u003e into the cabinet\u003cbr data-start=\"4427\" data-end=\"4430\"\u003e• \u003cstrong data-start=\"4432\" data-end=\"4462\"\u003eOpen flames are prohibited\u003c\/strong\u003e because they disrupt airflow\u003cbr data-start=\"4491\" data-end=\"4494\"\u003e• Use \u003cstrong data-start=\"4500\" data-end=\"4537\"\u003e≤10 mL disinfectant (70% alcohol)\u003c\/strong\u003e if needed\u003c\/p\u003e\n\u003cp data-start=\"4549\" data-end=\"4575\"\u003eRecommended disinfectants:\u003c\/p\u003e\n\u003cul data-start=\"4577\" data-end=\"4723\"\u003e\n\u003cli data-section-id=\"1j0b4p9\" data-start=\"4577\" data-end=\"4609\"\u003e\n\u003cp data-start=\"4579\" data-end=\"4609\"\u003eSodium hypochlorite (bleach)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v288x5\" data-start=\"4610\" data-end=\"4635\"\u003e\n\u003cp data-start=\"4612\" data-end=\"4635\"\u003eIodophors (Wescodyne)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y2pl61\" data-start=\"4636\" data-end=\"4669\"\u003e\n\u003cp data-start=\"4638\" data-end=\"4669\"\u003ePhenolics (Hilphene, Vespene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wzl42d\" data-start=\"4670\" data-end=\"4723\"\u003e\n\u003cp data-start=\"4672\" data-end=\"4723\"\u003eQuaternary ammonium compounds (Conflikt, Endbac II)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4725\" data-end=\"4728\"\u003e\n\u003ch1 data-section-id=\"hj61r4\" data-start=\"4730\" data-end=\"4751\"\u003eInstallation Notice\u003c\/h1\u003e\n\u003cp data-start=\"4753\" data-end=\"4827\"\u003e⚠ \u003cstrong data-start=\"4755\" data-end=\"4827\"\u003eInstallation requires a forklift or crane due to the cabinet weight.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4829\" data-end=\"4832\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4834\" data-end=\"4860\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"15ra0yv\" data-start=\"4862\" data-end=\"4888\"\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cul data-start=\"4890\" data-end=\"4950\"\u003e\n\u003cli data-section-id=\"ndr0xl\" data-start=\"4890\" data-end=\"4918\"\u003e\n\u003cp data-start=\"4892\" data-end=\"4918\"\u003e110V 60Hz 1-Phase – 400W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zjpxdf\" data-start=\"4919\" data-end=\"4950\"\u003e\n\u003cp data-start=\"4921\" data-end=\"4950\"\u003e220V 50\/60Hz 1-Phase – 400W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4952\" data-end=\"4958\"\u003eMotor:\u003c\/p\u003e\n\u003cul data-start=\"4959\" data-end=\"4980\"\u003e\n\u003cli data-section-id=\"1sxpufw\" data-start=\"4959\" data-end=\"4971\"\u003e\n\u003cp data-start=\"4961\" data-end=\"4971\"\u003e\u003cstrong data-start=\"4961\" data-end=\"4971\"\u003e1\/2 HP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f4jqo\" data-start=\"4972\" data-end=\"4980\"\u003e\n\u003cp data-start=\"4974\" data-end=\"4980\"\u003e\u003cstrong data-start=\"4974\" data-end=\"4980\"\u003e9A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4982\" data-end=\"4985\"\u003e\n\u003ch1 data-section-id=\"zba58a\" data-start=\"4987\" data-end=\"5011\"\u003eChamber Specifications\u003c\/h1\u003e\n\u003cp data-start=\"5013\" data-end=\"5024\"\u003eDimensions:\u003c\/p\u003e\n\u003cul data-start=\"5025\" data-end=\"5060\"\u003e\n\u003cli data-section-id=\"15bp53b\" data-start=\"5025\" data-end=\"5060\"\u003e\n\u003cp data-start=\"5027\" data-end=\"5060\"\u003e\u003cstrong data-start=\"5027\" data-end=\"5060\"\u003e48 × 23.5 × 26 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5062\" data-end=\"5071\"\u003eMaterial:\u003c\/p\u003e\n\u003cul data-start=\"5072\" data-end=\"5097\"\u003e\n\u003cli data-section-id=\"1yvwq7w\" data-start=\"5072\" data-end=\"5097\"\u003e\n\u003cp data-start=\"5074\" data-end=\"5097\"\u003e\u003cstrong data-start=\"5074\" data-end=\"5097\"\u003e304 Stainless Steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5099\" data-end=\"5121\"\u003eMaximum load capacity:\u003c\/p\u003e\n\u003cul data-start=\"5122\" data-end=\"5134\"\u003e\n\u003cli data-section-id=\"i7c2z4\" data-start=\"5122\" data-end=\"5134\"\u003e\n\u003cp data-start=\"5124\" data-end=\"5134\"\u003e\u003cstrong data-start=\"5124\" data-end=\"5134\"\u003e50 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5136\" data-end=\"5156\"\u003eAdditional features:\u003c\/p\u003e\n\u003cul data-start=\"5158\" data-end=\"5379\"\u003e\n\u003cli data-section-id=\"s03js1\" data-start=\"5158\" data-end=\"5195\"\u003e\n\u003cp data-start=\"5160\" data-end=\"5195\"\u003eFour internal power outlets (\u0026lt;500W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ixfs3r\" data-start=\"5196\" data-end=\"5226\"\u003e\n\u003cp data-start=\"5198\" data-end=\"5226\"\u003eStainless steel \u003cstrong data-start=\"5214\" data-end=\"5226\"\u003egas port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1998ep3\" data-start=\"5227\" data-end=\"5259\"\u003e\n\u003cp data-start=\"5229\" data-end=\"5259\"\u003eStainless steel \u003cstrong data-start=\"5245\" data-end=\"5259\"\u003ewater port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"km7pk9\" data-start=\"5260\" data-end=\"5307\"\u003e\n\u003cp data-start=\"5262\" data-end=\"5307\"\u003eStainless steel hanging bar with \u003cstrong data-start=\"5295\" data-end=\"5307\"\u003e10 hooks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5fk0xi\" data-start=\"5308\" data-end=\"5348\"\u003e\n\u003cp data-start=\"5310\" data-end=\"5348\"\u003eRemovable stainless steel work surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15ticne\" data-start=\"5349\" data-end=\"5379\"\u003e\n\u003cp data-start=\"5351\" data-end=\"5379\"\u003e\u003cstrong data-start=\"5351\" data-end=\"5379\"\u003e29.5 in ground clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5381\" data-end=\"5384\"\u003e\n\u003ch1 data-section-id=\"1sqsjx9\" data-start=\"5386\" data-end=\"5403\"\u003eLighting System\u003c\/h1\u003e\n\u003cp data-start=\"5405\" data-end=\"5418\"\u003eLED Lighting:\u003c\/p\u003e\n\u003cul data-start=\"5419\" data-end=\"5455\"\u003e\n\u003cli data-section-id=\"b997rn\" data-start=\"5419\" data-end=\"5432\"\u003e\n\u003cp data-start=\"5421\" data-end=\"5432\"\u003e\u003cstrong data-start=\"5421\" data-end=\"5432\"\u003e2 × 18W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x6abrz\" data-start=\"5433\" data-end=\"5455\"\u003e\n\u003cblockquote data-start=\"5435\" data-end=\"5455\"\u003e\n\u003cp data-start=\"5436\" data-end=\"5455\"\u003e1000 Lux brightness\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5457\" data-end=\"5479\"\u003eUV Sterilization Lamp:\u003c\/p\u003e\n\u003cul data-start=\"5480\" data-end=\"5571\"\u003e\n\u003cli data-section-id=\"1w0w9ig\" data-start=\"5480\" data-end=\"5503\"\u003e\n\u003cp data-start=\"5482\" data-end=\"5503\"\u003e\u003cstrong data-start=\"5482\" data-end=\"5503\"\u003e30W germicidal UV\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q9ul45\" data-start=\"5504\" data-end=\"5530\"\u003e\n\u003cp data-start=\"5506\" data-end=\"5530\"\u003eWavelength: \u003cstrong data-start=\"5518\" data-end=\"5530\"\u003e253.7 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"188x7p8\" data-start=\"5531\" data-end=\"5571\"\u003e\n\u003cp data-start=\"5533\" data-end=\"5571\"\u003eRecommended replacement: \u003cstrong data-start=\"5558\" data-end=\"5571\"\u003e600 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5573\" data-end=\"5576\"\u003e\n\u003ch1 data-section-id=\"16sr3qu\" data-start=\"5578\" data-end=\"5599\"\u003eAirflow Performance\u003c\/h1\u003e\n\u003cp data-start=\"5601\" data-end=\"5616\"\u003eAirflow Volume:\u003c\/p\u003e\n\u003cul data-start=\"5618\" data-end=\"5686\"\u003e\n\u003cli data-section-id=\"19g1ebh\" data-start=\"5618\" data-end=\"5639\"\u003e\n\u003cp data-start=\"5620\" data-end=\"5639\"\u003eInflow: \u003cstrong data-start=\"5628\" data-end=\"5639\"\u003e345 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x1t1zj\" data-start=\"5640\" data-end=\"5663\"\u003e\n\u003cp data-start=\"5642\" data-end=\"5663\"\u003eDownflow: \u003cstrong data-start=\"5652\" data-end=\"5663\"\u003e500 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zqfai6\" data-start=\"5664\" data-end=\"5686\"\u003e\n\u003cp data-start=\"5666\" data-end=\"5686\"\u003eExhaust: \u003cstrong data-start=\"5675\" data-end=\"5686\"\u003e345 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5688\" data-end=\"5702\"\u003eAirflow Speed:\u003c\/p\u003e\n\u003cul data-start=\"5704\" data-end=\"5755\"\u003e\n\u003cli data-section-id=\"j1kzym\" data-start=\"5704\" data-end=\"5729\"\u003e\n\u003cp data-start=\"5706\" data-end=\"5729\"\u003eInflow: \u003cstrong data-start=\"5714\" data-end=\"5729\"\u003e100–110 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sazy3f\" data-start=\"5730\" data-end=\"5755\"\u003e\n\u003cp data-start=\"5732\" data-end=\"5755\"\u003eDownflow: \u003cstrong data-start=\"5742\" data-end=\"5755\"\u003e60–70 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5757\" data-end=\"5774\"\u003eAir distribution:\u003c\/p\u003e\n\u003cul data-start=\"5776\" data-end=\"5818\"\u003e\n\u003cli data-section-id=\"19whf3f\" data-start=\"5776\" data-end=\"5798\"\u003e\n\u003cp data-start=\"5778\" data-end=\"5798\"\u003e\u003cstrong data-start=\"5778\" data-end=\"5798\"\u003e70% recirculated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cj7wo9\" data-start=\"5799\" data-end=\"5818\"\u003e\n\u003cp data-start=\"5801\" data-end=\"5818\"\u003e\u003cstrong data-start=\"5801\" data-end=\"5818\"\u003e30% exhausted\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5820\" data-end=\"5846\"\u003eRecommended top clearance:\u003c\/p\u003e\n\u003cul data-start=\"5848\" data-end=\"5863\"\u003e\n\u003cli data-section-id=\"1dp3gvl\" data-start=\"5848\" data-end=\"5863\"\u003e\n\u003cp data-start=\"5850\" data-end=\"5863\"\u003e\u003cstrong data-start=\"5850\" data-end=\"5863\"\u003e12 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5865\" data-end=\"5868\"\u003e\n\u003ch1 data-section-id=\"ru67nm\" data-start=\"5870\" data-end=\"5887\"\u003eHEPA Filtration\u003c\/h1\u003e\n\u003cul data-start=\"5889\" data-end=\"6035\"\u003e\n\u003cli data-section-id=\"g8fg3v\" data-start=\"5889\" data-end=\"5907\"\u003e\n\u003cp data-start=\"5891\" data-end=\"5907\"\u003eTwo HEPA filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cipdus\" data-start=\"5908\" data-end=\"5942\"\u003e\n\u003cp data-start=\"5910\" data-end=\"5942\"\u003e\u003cstrong data-start=\"5910\" data-end=\"5942\"\u003e99.999% efficiency at 0.3 μm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19yby0g\" data-start=\"5943\" data-end=\"5983\"\u003e\n\u003cp data-start=\"5945\" data-end=\"5983\"\u003eFilter life indicator and hour counter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pyccd9\" data-start=\"5984\" data-end=\"6035\"\u003e\n\u003cp data-start=\"5986\" data-end=\"6035\"\u003eRecommended replacement interval: \u003cstrong data-start=\"6020\" data-end=\"6035\"\u003e4,000 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6037\" data-end=\"6040\"\u003e\n\u003ch1 data-section-id=\"17x59vr\" data-start=\"6042\" data-end=\"6068\"\u003eFront Safety Glass Panel\u003c\/h1\u003e\n\u003cp data-start=\"6070\" data-end=\"6079\"\u003eMaterial:\u003c\/p\u003e\n\u003cul data-start=\"6081\" data-end=\"6155\"\u003e\n\u003cli data-section-id=\"1k6era1\" data-start=\"6081\" data-end=\"6118\"\u003e\n\u003cp data-start=\"6083\" data-end=\"6118\"\u003eDual-layer laminated tempered glass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isie6n\" data-start=\"6119\" data-end=\"6141\"\u003e\n\u003cp data-start=\"6121\" data-end=\"6141\"\u003eThickness: \u003cstrong data-start=\"6132\" data-end=\"6141\"\u003e\u0026gt;5 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9rz3gi\" data-start=\"6142\" data-end=\"6155\"\u003e\n\u003cp data-start=\"6144\" data-end=\"6155\"\u003eUV blocking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6157\" data-end=\"6173\"\u003eOpening heights:\u003c\/p\u003e\n\u003cul data-start=\"6175\" data-end=\"6246\"\u003e\n\u003cli data-section-id=\"1hi92q0\" data-start=\"6175\" data-end=\"6211\"\u003e\n\u003cp data-start=\"6177\" data-end=\"6211\"\u003eRecommended opening: \u003cstrong data-start=\"6198\" data-end=\"6211\"\u003e10 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a9l759\" data-start=\"6212\" data-end=\"6246\"\u003e\n\u003cp data-start=\"6214\" data-end=\"6246\"\u003eMaximum opening: \u003cstrong data-start=\"6231\" data-end=\"6246\"\u003e20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6248\" data-end=\"6251\"\u003e\n\u003ch1 data-section-id=\"jrwzgb\" data-start=\"6253\" data-end=\"6267\"\u003eConstruction\u003c\/h1\u003e\n\u003cp data-start=\"6269\" data-end=\"6277\"\u003eChamber:\u003c\/p\u003e\n\u003cul data-start=\"6278\" data-end=\"6303\"\u003e\n\u003cli data-section-id=\"1yhrsjg\" data-start=\"6278\" data-end=\"6303\"\u003e\n\u003cp data-start=\"6280\" data-end=\"6303\"\u003e\u003cstrong data-start=\"6280\" data-end=\"6303\"\u003e304 stainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6305\" data-end=\"6322\"\u003eExterior cabinet:\u003c\/p\u003e\n\u003cul data-start=\"6323\" data-end=\"6348\"\u003e\n\u003cli data-section-id=\"122h1zh\" data-start=\"6323\" data-end=\"6348\"\u003e\n\u003cp data-start=\"6325\" data-end=\"6348\"\u003e\u003cstrong data-start=\"6325\" data-end=\"6348\"\u003ePowder-coated steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6350\" data-end=\"6358\"\u003eCasters:\u003c\/p\u003e\n\u003cul data-start=\"6360\" data-end=\"6396\"\u003e\n\u003cli data-section-id=\"bcyt6t\" data-start=\"6360\" data-end=\"6396\"\u003e\n\u003cp data-start=\"6362\" data-end=\"6396\"\u003eFour casters with stabilizing feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6398\" data-end=\"6401\"\u003e\n\u003ch1 data-section-id=\"e0illa\" data-start=\"6403\" data-end=\"6416\"\u003eNoise Level\u003c\/h1\u003e\n\u003cul data-start=\"6418\" data-end=\"6434\"\u003e\n\u003cli data-section-id=\"10oevpt\" data-start=\"6418\" data-end=\"6434\"\u003e\n\u003cp data-start=\"6420\" data-end=\"6434\"\u003e\u003cstrong data-start=\"6420\" data-end=\"6434\"\u003e\u0026lt; 65 dB(A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6436\" data-end=\"6439\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6441\" data-end=\"6462\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6464\" data-end=\"6476\"\u003eUnit weight:\u003c\/p\u003e\n\u003cul data-start=\"6477\" data-end=\"6490\"\u003e\n\u003cli data-section-id=\"1l07via\" data-start=\"6477\" data-end=\"6490\"\u003e\n\u003cp data-start=\"6479\" data-end=\"6490\"\u003e\u003cstrong data-start=\"6479\" data-end=\"6490\"\u003e520 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6492\" data-end=\"6508\"\u003eShipping weight:\u003c\/p\u003e\n\u003cul data-start=\"6509\" data-end=\"6522\"\u003e\n\u003cli data-section-id=\"7a2csl\" data-start=\"6509\" data-end=\"6522\"\u003e\n\u003cp data-start=\"6511\" data-end=\"6522\"\u003e\u003cstrong data-start=\"6511\" data-end=\"6522\"\u003e725 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6524\" data-end=\"6540\"\u003eFully assembled:\u003c\/p\u003e\n\u003cul data-start=\"6542\" data-end=\"6579\"\u003e\n\u003cli data-section-id=\"bqwnq6\" data-start=\"6542\" data-end=\"6579\"\u003e\n\u003cp data-start=\"6544\" data-end=\"6579\"\u003e\u003cstrong data-start=\"6544\" data-end=\"6579\"\u003e54.5 × 30.5 × 90 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6581\" data-end=\"6595\"\u003eWithout stand:\u003c\/p\u003e\n\u003cul data-start=\"6597\" data-end=\"6624\"\u003e\n\u003cli data-section-id=\"1tnclxv\" data-start=\"6597\" data-end=\"6624\"\u003e\n\u003cp data-start=\"6599\" data-end=\"6624\"\u003e\u003cstrong data-start=\"6599\" data-end=\"6624\"\u003e54.5 × 30.5 × 63.5 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6626\" data-end=\"6646\"\u003eShipping dimensions:\u003c\/p\u003e\n\u003cul data-start=\"6648\" data-end=\"6669\"\u003e\n\u003cli data-section-id=\"18qnwa6\" data-start=\"6648\" data-end=\"6669\"\u003e\n\u003cp data-start=\"6650\" data-end=\"6669\"\u003e\u003cstrong data-start=\"6650\" data-end=\"6669\"\u003e61 × 43 × 76 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6671\" data-end=\"6674\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"6676\" data-end=\"6693\"\u003eSafety Features\u003c\/h1\u003e\n\u003cul data-start=\"6695\" data-end=\"6774\"\u003e\n\u003cli data-section-id=\"okczb7\" data-start=\"6695\" data-end=\"6719\"\u003e\n\u003cp data-start=\"6697\" data-end=\"6719\"\u003eAbnormal airflow alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"79k0g5\" data-start=\"6720\" data-end=\"6746\"\u003e\n\u003cp data-start=\"6722\" data-end=\"6746\"\u003eFilter replacement alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"epcgkk\" data-start=\"6747\" data-end=\"6774\"\u003e\n\u003cp data-start=\"6749\" data-end=\"6774\"\u003eUnsafe glass height alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6776\" data-end=\"6779\"\u003e\n\u003ch1 data-section-id=\"gk6d0t\" data-start=\"6781\" data-end=\"6797\"\u003eCertifications\u003c\/h1\u003e\n\u003cul data-start=\"6799\" data-end=\"6837\"\u003e\n\u003cli data-section-id=\"1c47sgs\" data-start=\"6799\" data-end=\"6837\"\u003e\n\u003cp data-start=\"6801\" data-end=\"6837\"\u003e\u003cstrong data-start=\"6801\" data-end=\"6837\"\u003eNSF\/ANSI 49 Certified (C0559576)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6839\" data-end=\"6842\"\u003e\n\u003ch1 data-section-id=\"1mk6eig\" data-start=\"6844\" data-end=\"6866\"\u003eIncluded Accessories\u003c\/h1\u003e\n\u003cul data-start=\"6868\" data-end=\"7266\"\u003e\n\u003cli data-section-id=\"5mmsu0\" data-start=\"6868\" data-end=\"6899\"\u003e\n\u003cp data-start=\"6870\" data-end=\"6899\"\u003eAi 4 Ft Biosafety Cabinet (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r26xpv\" data-start=\"6900\" data-end=\"6925\"\u003e\n\u003cp data-start=\"6902\" data-end=\"6925\"\u003eDetachable armrests (2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vfzy1\" data-start=\"6926\" data-end=\"6950\"\u003e\n\u003cp data-start=\"6928\" data-end=\"6950\"\u003eOn\/off foot switch (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ta7l23\" data-start=\"6951\" data-end=\"6971\"\u003e\n\u003cp data-start=\"6953\" data-end=\"6971\"\u003eRemote control (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jq3jq8\" data-start=\"6972\" data-end=\"7004\"\u003e\n\u003cp data-start=\"6974\" data-end=\"7004\"\u003eBottom drain port assembly (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xmqakt\" data-start=\"7005\" data-end=\"7031\"\u003e\n\u003cp data-start=\"7007\" data-end=\"7031\"\u003eBackup UV light tube (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v8zu14\" data-start=\"7032\" data-end=\"7048\"\u003e\n\u003cp data-start=\"7034\" data-end=\"7048\"\u003eHex wrench (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gmqmc3\" data-start=\"7049\" data-end=\"7082\"\u003e\n\u003cp data-start=\"7051\" data-end=\"7082\"\u003eGlass panel adjustment tool (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pgcq0w\" data-start=\"7083\" data-end=\"7112\"\u003e\n\u003cp data-start=\"7085\" data-end=\"7112\"\u003eFuses for control board (9)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qpk6kt\" data-start=\"7113\" data-end=\"7128\"\u003e\n\u003cp data-start=\"7115\" data-end=\"7128\"\u003eHex bolts (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n5o9at\" data-start=\"7129\" data-end=\"7146\"\u003e\n\u003cp data-start=\"7131\" data-end=\"7146\"\u003eWasher sets (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cc016a\" data-start=\"7147\" data-end=\"7179\"\u003e\n\u003cp data-start=\"7149\" data-end=\"7179\"\u003eVent clamps (Gen 1 models) (2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wbu1fv\" data-start=\"7180\" data-end=\"7217\"\u003e\n\u003cp data-start=\"7182\" data-end=\"7217\"\u003eStand assembly with casters (3 pcs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ebhtgg\" data-start=\"7218\" data-end=\"7248\"\u003e\n\u003cp data-start=\"7220\" data-end=\"7248\"\u003eStandard 110V power cord (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ckllwz\" data-start=\"7249\" data-end=\"7266\"\u003e\n\u003cp data-start=\"7251\" data-end=\"7266\"\u003eUser manual (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7268\" data-end=\"7271\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7273\" data-end=\"7283\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7285\" data-end=\"7317\"\u003e\u003cstrong data-start=\"7285\" data-end=\"7317\"\u003e1 Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282461815106,"sku":null,"price":8590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/bc-4f1.png?v=1773584664","url":"https:\/\/summitsupplydirect.com\/products\/across-international-bc-4f-110-nsf-certified-4-ft-class-ii-type-a2-biosafety-cabinet","provider":"Summit Supply Direct","version":"1.0","type":"link"}