{"product_id":"across-international-bc-3f-110-nsf-certified-3-ft-class-ii-type-a2-biosafety-cabinet","title":"Across International BC-3F.110 NSF Certified 3 Ft Class II Type A2 Biosafety Cabinet","description":"\u003ch2 data-section-id=\"rv096a\" data-start=\"383\" data-end=\"458\"\u003eNSF Certified Class II Biosafety Cabinet for Safe Laboratory Containment\u003c\/h2\u003e\n\u003cp data-start=\"460\" data-end=\"723\"\u003eThe \u003cstrong data-start=\"464\" data-end=\"516\"\u003eAi BC-3F 3 Ft Class II Type A2 Biosafety Cabinet\u003c\/strong\u003e is a \u003cstrong data-start=\"522\" data-end=\"573\"\u003eNSF\/ANSI 49 certified biological safety cabinet\u003c\/strong\u003e designed to safely handle potentially infectious materials while protecting laboratory personnel, sensitive samples, and the surrounding environment.\u003c\/p\u003e\n\u003cp data-start=\"725\" data-end=\"1024\"\u003eA \u003cstrong data-start=\"727\" data-end=\"754\"\u003ebiosafety cabinet (BSC)\u003c\/strong\u003e—also known as a \u003cstrong data-start=\"771\" data-end=\"834\"\u003ebiological safety cabinet or microbiological safety cabinet\u003c\/strong\u003e—is an enclosed, ventilated laboratory workstation used when working with biological materials contaminated with or potentially contaminated by pathogens requiring a defined biosafety level.\u003c\/p\u003e\n\u003cp data-start=\"1026\" data-end=\"1328\"\u003eThe primary purpose of a biosafety cabinet is to \u003cstrong data-start=\"1075\" data-end=\"1147\"\u003eprotect the laboratory worker and environment from harmful pathogens\u003c\/strong\u003e. The \u003cstrong data-start=\"1153\" data-end=\"1241\"\u003eAi Class II Type A2 cabinet uses dual HEPA filtration and controlled laminar airflow\u003c\/strong\u003e to capture bacteria, viruses, and airborne contaminants before the air exits the unit.\u003c\/p\u003e\n\u003cp data-start=\"1330\" data-end=\"1607\"\u003eUnlike laminar flow clean benches that blow unfiltered air toward the user, this \u003cstrong data-start=\"1411\" data-end=\"1477\"\u003ebiosafety cabinet filters all exhaust air through HEPA filters\u003c\/strong\u003e, making it suitable for \u003cstrong data-start=\"1502\" data-end=\"1606\"\u003emicrobiology research, pharmaceutical laboratories, virology testing, and COVID-19 specimen handling\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1609\" data-end=\"1612\"\u003e\n\u003ch1 data-section-id=\"nms9yd\" data-start=\"1614\" data-end=\"1673\"\u003eKey Features of the Ai Class II Type A2 Biosafety Cabinet\u003c\/h1\u003e\n\u003ch3 data-section-id=\"15argzx\" data-start=\"1675\" data-end=\"1700\"\u003eNSF\/ANSI 49 Certified\u003c\/h3\u003e\n\u003cp data-start=\"1701\" data-end=\"1811\"\u003eFully compliant with \u003cstrong data-start=\"1722\" data-end=\"1746\"\u003eNSF\/ANSI Standard 49\u003c\/strong\u003e, ensuring safe containment for biological research applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1luefyj\" data-start=\"1813\" data-end=\"1862\"\u003eIdeal for Pathogen \u0026amp; COVID-19 Sample Handling\u003c\/h3\u003e\n\u003cp data-start=\"1863\" data-end=\"1984\"\u003eDesigned for laboratories handling \u003cstrong data-start=\"1898\" data-end=\"1983\"\u003emicrobial cultures, viral samples, and biological materials requiring containment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4s51tn\" data-start=\"1986\" data-end=\"2017\"\u003eDual HEPA Filtration System\u003c\/h3\u003e\n\u003cp data-start=\"2018\" data-end=\"2132\"\u003eTwo \u003cstrong data-start=\"2022\" data-end=\"2072\"\u003eHEPA filters with 99.999% efficiency at 0.3 μm\u003c\/strong\u003e capture airborne contaminants and maintain sterile airflow.\u003c\/p\u003e\n\u003ch3 data-section-id=\"cr92pk\" data-start=\"2134\" data-end=\"2166\"\u003eMotorized Front Glass Window\u003c\/h3\u003e\n\u003cp data-start=\"2167\" data-end=\"2291\"\u003eTempered safety glass panel with \u003cstrong data-start=\"2200\" data-end=\"2256\"\u003emotorized lift system and remote foot switch control\u003c\/strong\u003e for safe and convenient operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"73her6\" data-start=\"2293\" data-end=\"2322\"\u003eBuilt-in UV Sterilization\u003c\/h3\u003e\n\u003cp data-start=\"2323\" data-end=\"2428\"\u003eIntegrated \u003cstrong data-start=\"2334\" data-end=\"2371\"\u003e20W germicidal UV lamp (253.7 nm)\u003c\/strong\u003e disinfects the chamber before and after laboratory work.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xu6epd\" data-start=\"2430\" data-end=\"2461\"\u003eAdvanced LCD Control System\u003c\/h3\u003e\n\u003cp data-start=\"2462\" data-end=\"2597\"\u003eLarge \u003cstrong data-start=\"2468\" data-end=\"2529\"\u003eLCD display with soft-touch controls and remote operation\u003c\/strong\u003e allows easy monitoring of airflow, filter life, and cabinet status.\u003c\/p\u003e\n\u003ch3 data-section-id=\"i18xzo\" data-start=\"2599\" data-end=\"2628\"\u003eAutomatic Airflow Control\u003c\/h3\u003e\n\u003cp data-start=\"2629\" data-end=\"2730\"\u003eAutomatically adjusts airflow speed and alerts users of abnormal airflow or filter replacement needs.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2my9b2\" data-start=\"2732\" data-end=\"2767\"\u003eDurable Stainless Steel Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2768\" data-end=\"2867\"\u003eInterior \u003cstrong data-start=\"2777\" data-end=\"2808\"\u003e304 stainless steel chamber\u003c\/strong\u003e provides excellent corrosion resistance and easy cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5uay7a\" data-start=\"2869\" data-end=\"2903\"\u003eAnti-Mold \u0026amp; Antiseptic Coating\u003c\/h3\u003e\n\u003cp data-start=\"2904\" data-end=\"2986\"\u003eSpecially treated cabinet housing prevents microbial buildup on external surfaces.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ssc6lj\" data-start=\"2988\" data-end=\"3015\"\u003eEasy Maintenance Design\u003c\/h3\u003e\n\u003cp data-start=\"3016\" data-end=\"3108\"\u003e\u003cstrong data-start=\"3016\" data-end=\"3050\"\u003ePneumatic front panel supports\u003c\/strong\u003e allow quick access for cabinet maintenance and servicing.\u003c\/p\u003e\n\u003chr data-start=\"3110\" data-end=\"3113\"\u003e\n\u003ch1 data-section-id=\"9ocsyr\" data-start=\"3115\" data-end=\"3162\"\u003eWhat Is a Class II Type A2 Biosafety Cabinet?\u003c\/h1\u003e\n\u003cp data-start=\"3164\" data-end=\"3229\"\u003eA \u003cstrong data-start=\"3166\" data-end=\"3204\"\u003eClass II Type A2 biosafety cabinet\u003c\/strong\u003e provides protection for:\u003c\/p\u003e\n\u003cul data-start=\"3231\" data-end=\"3319\"\u003e\n\u003cli data-section-id=\"51iad5\" data-start=\"3231\" data-end=\"3253\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3253\"\u003eLaboratory personnel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iicqc2\" data-start=\"3254\" data-end=\"3283\"\u003e\n\u003cp data-start=\"3256\" data-end=\"3283\"\u003eThe surrounding environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w4z5xh\" data-start=\"3284\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3286\" data-end=\"3319\"\u003eThe sterility of research samples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3321\" data-end=\"3485\"\u003eAir enters the cabinet through the front opening, creating a \u003cstrong data-start=\"3382\" data-end=\"3419\"\u003eprotective inward airflow barrier\u003c\/strong\u003e that prevents contaminated air from escaping into the laboratory.\u003c\/p\u003e\n\u003cp data-start=\"3487\" data-end=\"3527\"\u003eAirflow distribution inside the cabinet:\u003c\/p\u003e\n\u003cul data-start=\"3529\" data-end=\"3624\"\u003e\n\u003cli data-section-id=\"h5kbu5\" data-start=\"3529\" data-end=\"3583\"\u003e\n\u003cp data-start=\"3531\" data-end=\"3583\"\u003e\u003cstrong data-start=\"3531\" data-end=\"3583\"\u003e70% recirculated internally through HEPA filters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12ugizt\" data-start=\"3584\" data-end=\"3624\"\u003e\n\u003cp data-start=\"3586\" data-end=\"3624\"\u003e\u003cstrong data-start=\"3586\" data-end=\"3624\"\u003e30% exhausted through the top vent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3626\" data-end=\"3776\"\u003eBecause of this design, \u003cstrong data-start=\"3650\" data-end=\"3732\"\u003eType A2 cabinets represent about 90% of biosafety cabinets installed worldwide\u003c\/strong\u003e, making them the most widely used BSC type.\u003c\/p\u003e\n\u003chr data-start=\"3778\" data-end=\"3781\"\u003e\n\u003ch1 data-section-id=\"1baxwhi\" data-start=\"3783\" data-end=\"3804\"\u003eOperating Procedure\u003c\/h1\u003e\n\u003ch3 data-section-id=\"18w7ypo\" data-start=\"3806\" data-end=\"3820\"\u003eBefore Use\u003c\/h3\u003e\n\u003col data-start=\"3822\" data-end=\"4112\"\u003e\n\u003cli data-section-id=\"l7xgzw\" data-start=\"3822\" data-end=\"3859\"\u003e\n\u003cp data-start=\"3825\" data-end=\"3859\"\u003eFully close the front glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nocar6\" data-start=\"3860\" data-end=\"3929\"\u003e\n\u003cp data-start=\"3863\" data-end=\"3929\"\u003eActivate the \u003cstrong data-start=\"3876\" data-end=\"3903\"\u003eUV light for 30 minutes\u003c\/strong\u003e to disinfect the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aysqvu\" data-start=\"3930\" data-end=\"3979\"\u003e\n\u003cp data-start=\"3933\" data-end=\"3979\"\u003eLeave the room during the sterilization cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cdaqn8\" data-start=\"3980\" data-end=\"4039\"\u003e\n\u003cp data-start=\"3983\" data-end=\"4039\"\u003eRaise the glass panel to the recommended opening height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ezz6q5\" data-start=\"4040\" data-end=\"4112\"\u003e\n\u003cp data-start=\"4043\" data-end=\"4112\"\u003eTurn on airflow circulation for \u003cstrong data-start=\"4075\" data-end=\"4111\"\u003e10 minutes before beginning work\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-section-id=\"qz8j6p\" data-start=\"4114\" data-end=\"4127\"\u003eAfter Use\u003c\/h3\u003e\n\u003col data-start=\"4129\" data-end=\"4246\"\u003e\n\u003cli data-section-id=\"k72j3a\" data-start=\"4129\" data-end=\"4160\"\u003e\n\u003cp data-start=\"4132\" data-end=\"4160\"\u003eClose the front glass panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"54n16o\" data-start=\"4161\" data-end=\"4246\"\u003e\n\u003cp data-start=\"4164\" data-end=\"4246\"\u003eTurn on the \u003cstrong data-start=\"4176\" data-end=\"4225\"\u003eUV sterilization light for another 30 minutes\u003c\/strong\u003e for decontamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"4248\" data-end=\"4251\"\u003e\n\u003ch1 data-section-id=\"1nileve\" data-start=\"4253\" data-end=\"4289\"\u003eBiosafety Cabinet Usage Guidelines\u003c\/h1\u003e\n\u003cp data-start=\"4291\" data-end=\"4316\"\u003eTo ensure safe operation:\u003c\/p\u003e\n\u003cp data-start=\"4318\" data-end=\"4629\"\u003e• Do \u003cstrong data-start=\"4323\" data-end=\"4367\"\u003enot use flammable or explosive materials\u003c\/strong\u003e\u003cbr data-start=\"4367\" data-end=\"4370\"\u003e• Avoid \u003cstrong data-start=\"4378\" data-end=\"4431\"\u003evolatile chemicals that could damage HEPA filters\u003c\/strong\u003e\u003cbr data-start=\"4431\" data-end=\"4434\"\u003e• Do \u003cstrong data-start=\"4439\" data-end=\"4478\"\u003enot introduce toxic chemical vapors\u003c\/strong\u003e\u003cbr data-start=\"4478\" data-end=\"4481\"\u003e• \u003cstrong data-start=\"4483\" data-end=\"4513\"\u003eOpen flames are prohibited\u003c\/strong\u003e because they disrupt airflow patterns\u003cbr data-start=\"4551\" data-end=\"4554\"\u003e• Only \u003cstrong data-start=\"4561\" data-end=\"4614\"\u003esmall quantities (≤10 mL) of disinfectant alcohol\u003c\/strong\u003e should be used\u003c\/p\u003e\n\u003cp data-start=\"4631\" data-end=\"4665\"\u003eRecommended disinfectants include:\u003c\/p\u003e\n\u003cul data-start=\"4667\" data-end=\"4807\"\u003e\n\u003cli data-section-id=\"411yfh\" data-start=\"4667\" data-end=\"4697\"\u003e\n\u003cp data-start=\"4669\" data-end=\"4697\"\u003eSodium hypochlorite (bleach)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1016zl5\" data-start=\"4698\" data-end=\"4721\"\u003e\n\u003cp data-start=\"4700\" data-end=\"4721\"\u003eIodophors (Wescodyne)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vstz3d\" data-start=\"4722\" data-end=\"4753\"\u003e\n\u003cp data-start=\"4724\" data-end=\"4753\"\u003ePhenolics (Hilphene, Vespene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wzl42d\" data-start=\"4754\" data-end=\"4807\"\u003e\n\u003cp data-start=\"4756\" data-end=\"4807\"\u003eQuaternary ammonium compounds (Conflikt, Endbac II)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4809\" data-end=\"4812\"\u003e\n\u003ch1 data-section-id=\"hj61r4\" data-start=\"4814\" data-end=\"4835\"\u003eInstallation Notice\u003c\/h1\u003e\n\u003cp data-start=\"4837\" data-end=\"4911\"\u003e⚠ \u003cstrong data-start=\"4839\" data-end=\"4911\"\u003eInstallation requires a forklift or crane due to the cabinet weight.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4913\" data-end=\"4916\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4918\" data-end=\"4944\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4946\" data-end=\"4954\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4955\" data-end=\"4960\"\u003eBC-3F\u003c\/p\u003e\n\u003chr data-start=\"4962\" data-end=\"4965\"\u003e\n\u003ch1 data-section-id=\"1pvd1l0\" data-start=\"4967\" data-end=\"4992\"\u003eElectrical Requirements\u003c\/h1\u003e\n\u003cul data-start=\"4994\" data-end=\"5064\"\u003e\n\u003cli data-section-id=\"1yunfsa\" data-start=\"4994\" data-end=\"5024\"\u003e\n\u003cp data-start=\"4996\" data-end=\"5024\"\u003e\u003cstrong data-start=\"4996\" data-end=\"5024\"\u003e115V, 60Hz, Single Phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ip3hy1\" data-start=\"5025\" data-end=\"5040\"\u003e\n\u003cp data-start=\"5027\" data-end=\"5040\"\u003e\u003cstrong data-start=\"5027\" data-end=\"5040\"\u003e400 Watts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"na99cp\" data-start=\"5041\" data-end=\"5064\"\u003e\n\u003cp data-start=\"5043\" data-end=\"5064\"\u003eMotor: \u003cstrong data-start=\"5050\" data-end=\"5064\"\u003e1\/2 HP, 9A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5066\" data-end=\"5069\"\u003e\n\u003ch1 data-section-id=\"zba58a\" data-start=\"5071\" data-end=\"5095\"\u003eChamber Specifications\u003c\/h1\u003e\n\u003cp data-start=\"5097\" data-end=\"5108\"\u003eDimensions:\u003c\/p\u003e\n\u003cp data-start=\"5110\" data-end=\"5145\"\u003e\u003cstrong data-start=\"5110\" data-end=\"5145\"\u003e35.8 × 23.5 × 26 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5147\" data-end=\"5156\"\u003eMaterial:\u003c\/p\u003e\n\u003cp data-start=\"5158\" data-end=\"5181\"\u003e\u003cstrong data-start=\"5158\" data-end=\"5181\"\u003e304 Stainless Steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5183\" data-end=\"5192\"\u003eFeatures:\u003c\/p\u003e\n\u003cul data-start=\"5194\" data-end=\"5415\"\u003e\n\u003cli data-section-id=\"s03js1\" data-start=\"5194\" data-end=\"5231\"\u003e\n\u003cp data-start=\"5196\" data-end=\"5231\"\u003eFour internal power outlets (\u0026lt;500W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ixfs3r\" data-start=\"5232\" data-end=\"5262\"\u003e\n\u003cp data-start=\"5234\" data-end=\"5262\"\u003eStainless steel \u003cstrong data-start=\"5250\" data-end=\"5262\"\u003egas port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1998ep3\" data-start=\"5263\" data-end=\"5295\"\u003e\n\u003cp data-start=\"5265\" data-end=\"5295\"\u003eStainless steel \u003cstrong data-start=\"5281\" data-end=\"5295\"\u003ewater port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"km7pk9\" data-start=\"5296\" data-end=\"5343\"\u003e\n\u003cp data-start=\"5298\" data-end=\"5343\"\u003eStainless steel hanging bar with \u003cstrong data-start=\"5331\" data-end=\"5343\"\u003e10 hooks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5fk0xi\" data-start=\"5344\" data-end=\"5384\"\u003e\n\u003cp data-start=\"5346\" data-end=\"5384\"\u003eRemovable stainless steel work surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15ticne\" data-start=\"5385\" data-end=\"5415\"\u003e\n\u003cp data-start=\"5387\" data-end=\"5415\"\u003e\u003cstrong data-start=\"5387\" data-end=\"5415\"\u003e29.5 in ground clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5417\" data-end=\"5420\"\u003e\n\u003ch1 data-section-id=\"1sqsjx9\" data-start=\"5422\" data-end=\"5439\"\u003eLighting System\u003c\/h1\u003e\n\u003cp data-start=\"5441\" data-end=\"5454\"\u003eLED Lighting:\u003c\/p\u003e\n\u003cul data-start=\"5456\" data-end=\"5492\"\u003e\n\u003cli data-section-id=\"b9fd7f\" data-start=\"5456\" data-end=\"5469\"\u003e\n\u003cp data-start=\"5458\" data-end=\"5469\"\u003e\u003cstrong data-start=\"5458\" data-end=\"5469\"\u003e2 × 10W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x6abrz\" data-start=\"5470\" data-end=\"5492\"\u003e\n\u003cblockquote data-start=\"5472\" data-end=\"5492\"\u003e\n\u003cp data-start=\"5473\" data-end=\"5492\"\u003e1000 Lux brightness\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5494\" data-end=\"5511\"\u003eUV Sterilization:\u003c\/p\u003e\n\u003cul data-start=\"5513\" data-end=\"5606\"\u003e\n\u003cli data-section-id=\"1uxaheh\" data-start=\"5513\" data-end=\"5541\"\u003e\n\u003cp data-start=\"5515\" data-end=\"5541\"\u003e\u003cstrong data-start=\"5515\" data-end=\"5541\"\u003e20W germicidal UV lamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q9ul45\" data-start=\"5542\" data-end=\"5568\"\u003e\n\u003cp data-start=\"5544\" data-end=\"5568\"\u003eWavelength: \u003cstrong data-start=\"5556\" data-end=\"5568\"\u003e253.7 nm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17y7axi\" data-start=\"5569\" data-end=\"5606\"\u003e\n\u003cp data-start=\"5571\" data-end=\"5606\"\u003eReplacement interval: \u003cstrong data-start=\"5593\" data-end=\"5606\"\u003e600 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5608\" data-end=\"5611\"\u003e\n\u003ch1 data-section-id=\"16sr3qu\" data-start=\"5613\" data-end=\"5634\"\u003eAirflow Performance\u003c\/h1\u003e\n\u003cp data-start=\"5636\" data-end=\"5651\"\u003eAirflow Volume:\u003c\/p\u003e\n\u003cul data-start=\"5653\" data-end=\"5721\"\u003e\n\u003cli data-section-id=\"1ufdva5\" data-start=\"5653\" data-end=\"5674\"\u003e\n\u003cp data-start=\"5655\" data-end=\"5674\"\u003eInflow: \u003cstrong data-start=\"5663\" data-end=\"5674\"\u003e255 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8juke9\" data-start=\"5675\" data-end=\"5698\"\u003e\n\u003cp data-start=\"5677\" data-end=\"5698\"\u003eDownflow: \u003cstrong data-start=\"5687\" data-end=\"5698\"\u003e380 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fzb9xq\" data-start=\"5699\" data-end=\"5721\"\u003e\n\u003cp data-start=\"5701\" data-end=\"5721\"\u003eExhaust: \u003cstrong data-start=\"5710\" data-end=\"5721\"\u003e255 CFM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5723\" data-end=\"5737\"\u003eAirflow Speed:\u003c\/p\u003e\n\u003cul data-start=\"5739\" data-end=\"5790\"\u003e\n\u003cli data-section-id=\"j1kzym\" data-start=\"5739\" data-end=\"5764\"\u003e\n\u003cp data-start=\"5741\" data-end=\"5764\"\u003eInflow: \u003cstrong data-start=\"5749\" data-end=\"5764\"\u003e100–110 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sazy3f\" data-start=\"5765\" data-end=\"5790\"\u003e\n\u003cp data-start=\"5767\" data-end=\"5790\"\u003eDownflow: \u003cstrong data-start=\"5777\" data-end=\"5790\"\u003e60–70 FPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5792\" data-end=\"5809\"\u003eAir distribution:\u003c\/p\u003e\n\u003cul data-start=\"5811\" data-end=\"5853\"\u003e\n\u003cli data-section-id=\"19whf3f\" data-start=\"5811\" data-end=\"5833\"\u003e\n\u003cp data-start=\"5813\" data-end=\"5833\"\u003e\u003cstrong data-start=\"5813\" data-end=\"5833\"\u003e70% recirculated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cj7wo9\" data-start=\"5834\" data-end=\"5853\"\u003e\n\u003cp data-start=\"5836\" data-end=\"5853\"\u003e\u003cstrong data-start=\"5836\" data-end=\"5853\"\u003e30% exhausted\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5855\" data-end=\"5881\"\u003eRecommended top clearance:\u003c\/p\u003e\n\u003cp data-start=\"5883\" data-end=\"5896\"\u003e\u003cstrong data-start=\"5883\" data-end=\"5896\"\u003e12 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5898\" data-end=\"5901\"\u003e\n\u003ch1 data-section-id=\"ru67nm\" data-start=\"5903\" data-end=\"5920\"\u003eHEPA Filtration\u003c\/h1\u003e\n\u003cul data-start=\"5922\" data-end=\"6068\"\u003e\n\u003cli data-section-id=\"g8fg3v\" data-start=\"5922\" data-end=\"5940\"\u003e\n\u003cp data-start=\"5924\" data-end=\"5940\"\u003eTwo HEPA filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cipdus\" data-start=\"5941\" data-end=\"5975\"\u003e\n\u003cp data-start=\"5943\" data-end=\"5975\"\u003e\u003cstrong data-start=\"5943\" data-end=\"5975\"\u003e99.999% efficiency at 0.3 μm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yp1mfc\" data-start=\"5976\" data-end=\"6016\"\u003e\n\u003cp data-start=\"5978\" data-end=\"6016\"\u003eFilter hour indicator and life monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pyccd9\" data-start=\"6017\" data-end=\"6068\"\u003e\n\u003cp data-start=\"6019\" data-end=\"6068\"\u003eRecommended replacement interval: \u003cstrong data-start=\"6053\" data-end=\"6068\"\u003e4,000 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6070\" data-end=\"6073\"\u003e\n\u003ch1 data-section-id=\"17x59vr\" data-start=\"6075\" data-end=\"6101\"\u003eFront Safety Glass Panel\u003c\/h1\u003e\n\u003cp data-start=\"6103\" data-end=\"6112\"\u003eMaterial:\u003c\/p\u003e\n\u003cul data-start=\"6114\" data-end=\"6187\"\u003e\n\u003cli data-section-id=\"tpgp93\" data-start=\"6114\" data-end=\"6151\"\u003e\n\u003cp data-start=\"6116\" data-end=\"6151\"\u003eLaminated \u003cstrong data-start=\"6126\" data-end=\"6151\"\u003etempered safety glass\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rqbpo5\" data-start=\"6152\" data-end=\"6173\"\u003e\n\u003cp data-start=\"6154\" data-end=\"6173\"\u003eThickness \u003cstrong data-start=\"6164\" data-end=\"6173\"\u003e\u0026gt;5 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9rz3gi\" data-start=\"6174\" data-end=\"6187\"\u003e\n\u003cp data-start=\"6176\" data-end=\"6187\"\u003eUV blocking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6189\" data-end=\"6205\"\u003eOpening heights:\u003c\/p\u003e\n\u003cul data-start=\"6207\" data-end=\"6278\"\u003e\n\u003cli data-section-id=\"1hi92q0\" data-start=\"6207\" data-end=\"6243\"\u003e\n\u003cp data-start=\"6209\" data-end=\"6243\"\u003eRecommended opening: \u003cstrong data-start=\"6230\" data-end=\"6243\"\u003e10 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a9l759\" data-start=\"6244\" data-end=\"6278\"\u003e\n\u003cp data-start=\"6246\" data-end=\"6278\"\u003eMaximum opening: \u003cstrong data-start=\"6263\" data-end=\"6278\"\u003e20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6280\" data-end=\"6283\"\u003e\n\u003ch1 data-section-id=\"jrwzgb\" data-start=\"6285\" data-end=\"6299\"\u003eConstruction\u003c\/h1\u003e\n\u003cp data-start=\"6301\" data-end=\"6309\"\u003eChamber:\u003c\/p\u003e\n\u003cul data-start=\"6311\" data-end=\"6336\"\u003e\n\u003cli data-section-id=\"1yhrsjg\" data-start=\"6311\" data-end=\"6336\"\u003e\n\u003cp data-start=\"6313\" data-end=\"6336\"\u003e\u003cstrong data-start=\"6313\" data-end=\"6336\"\u003e304 stainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6338\" data-end=\"6355\"\u003eExterior cabinet:\u003c\/p\u003e\n\u003cul data-start=\"6357\" data-end=\"6382\"\u003e\n\u003cli data-section-id=\"4uf45c\" data-start=\"6357\" data-end=\"6382\"\u003e\n\u003cp data-start=\"6359\" data-end=\"6382\"\u003e\u003cstrong data-start=\"6359\" data-end=\"6382\"\u003ePowder coated steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6384\" data-end=\"6392\"\u003eCasters:\u003c\/p\u003e\n\u003cul data-start=\"6394\" data-end=\"6430\"\u003e\n\u003cli data-section-id=\"bcyt6t\" data-start=\"6394\" data-end=\"6430\"\u003e\n\u003cp data-start=\"6396\" data-end=\"6430\"\u003eFour casters with stabilizing feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6432\" data-end=\"6435\"\u003e\n\u003ch1 data-section-id=\"e0illa\" data-start=\"6437\" data-end=\"6450\"\u003eNoise Level\u003c\/h1\u003e\n\u003cp data-start=\"6452\" data-end=\"6466\"\u003e\u003cstrong data-start=\"6452\" data-end=\"6466\"\u003e\u0026lt; 65 dB(A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6468\" data-end=\"6471\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6473\" data-end=\"6494\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6496\" data-end=\"6508\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"6510\" data-end=\"6521\"\u003e\u003cstrong data-start=\"6510\" data-end=\"6521\"\u003e450 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6523\" data-end=\"6539\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"6541\" data-end=\"6552\"\u003e\u003cstrong data-start=\"6541\" data-end=\"6552\"\u003e595 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6554\" data-end=\"6570\"\u003eFully assembled:\u003c\/p\u003e\n\u003cp data-start=\"6572\" data-end=\"6607\"\u003e\u003cstrong data-start=\"6572\" data-end=\"6607\"\u003e42.8 × 30.5 × 89 in (W × D × H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6609\" data-end=\"6623\"\u003eWithout stand:\u003c\/p\u003e\n\u003cp data-start=\"6625\" data-end=\"6650\"\u003e\u003cstrong data-start=\"6625\" data-end=\"6650\"\u003e42.8 × 30.5 × 62.3 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6652\" data-end=\"6672\"\u003eShipping dimensions:\u003c\/p\u003e\n\u003cp data-start=\"6674\" data-end=\"6695\"\u003e\u003cstrong data-start=\"6674\" data-end=\"6695\"\u003e48 × 40 × 72.5 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6697\" data-end=\"6700\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"6702\" data-end=\"6719\"\u003eSafety Features\u003c\/h1\u003e\n\u003cul data-start=\"6721\" data-end=\"6814\"\u003e\n\u003cli data-section-id=\"okczb7\" data-start=\"6721\" data-end=\"6745\"\u003e\n\u003cp data-start=\"6723\" data-end=\"6745\"\u003eAbnormal airflow alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"79k0g5\" data-start=\"6746\" data-end=\"6772\"\u003e\n\u003cp data-start=\"6748\" data-end=\"6772\"\u003eFilter replacement alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fkffwq\" data-start=\"6773\" data-end=\"6814\"\u003e\n\u003cp data-start=\"6775\" data-end=\"6814\"\u003eFront glass panel unsafe height warning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6816\" data-end=\"6819\"\u003e\n\u003ch1 data-section-id=\"gk6d0t\" data-start=\"6821\" data-end=\"6837\"\u003eCertifications\u003c\/h1\u003e\n\u003cp data-start=\"6839\" data-end=\"6875\"\u003e\u003cstrong data-start=\"6839\" data-end=\"6875\"\u003eNSF\/ANSI 49 Certified (C0559576)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6877\" data-end=\"6880\"\u003e\n\u003ch1 data-section-id=\"1mk6eig\" data-start=\"6882\" data-end=\"6904\"\u003eIncluded Accessories\u003c\/h1\u003e\n\u003cul data-start=\"6906\" data-end=\"7246\"\u003e\n\u003cli data-section-id=\"6vim3z\" data-start=\"6906\" data-end=\"6933\"\u003e\n\u003cp data-start=\"6908\" data-end=\"6933\"\u003eAi 3 Ft Biosafety Cabinet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r26xpv\" data-start=\"6934\" data-end=\"6959\"\u003e\n\u003cp data-start=\"6936\" data-end=\"6959\"\u003eDetachable armrests (2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19larl4\" data-start=\"6960\" data-end=\"6997\"\u003e\n\u003cp data-start=\"6962\" data-end=\"6997\"\u003eFoot switch for glass panel control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lj6d2j\" data-start=\"6998\" data-end=\"7014\"\u003e\n\u003cp data-start=\"7000\" data-end=\"7014\"\u003eRemote control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ebodao\" data-start=\"7015\" data-end=\"7043\"\u003e\n\u003cp data-start=\"7017\" data-end=\"7043\"\u003eBottom drain port assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1npt8xp\" data-start=\"7044\" data-end=\"7066\"\u003e\n\u003cp data-start=\"7046\" data-end=\"7066\"\u003eBackup UV light tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vt82d4\" data-start=\"7067\" data-end=\"7079\"\u003e\n\u003cp data-start=\"7069\" data-end=\"7079\"\u003eHex wrench\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rvhpt4\" data-start=\"7080\" data-end=\"7115\"\u003e\n\u003cp data-start=\"7082\" data-end=\"7115\"\u003eGlass panel motor adjustment tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xbxkhn\" data-start=\"7116\" data-end=\"7141\"\u003e\n\u003cp data-start=\"7118\" data-end=\"7141\"\u003eControl board fuses (9)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qpk6kt\" data-start=\"7142\" data-end=\"7157\"\u003e\n\u003cp data-start=\"7144\" data-end=\"7157\"\u003eHex bolts (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n5o9at\" data-start=\"7158\" data-end=\"7175\"\u003e\n\u003cp data-start=\"7160\" data-end=\"7175\"\u003eWasher sets (7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tu4qog\" data-start=\"7176\" data-end=\"7202\"\u003e\n\u003cp data-start=\"7178\" data-end=\"7202\"\u003eStandard 110V power cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1islffd\" data-start=\"7203\" data-end=\"7232\"\u003e\n\u003cp data-start=\"7205\" data-end=\"7232\"\u003eStand assembly with casters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"7233\" data-end=\"7246\"\u003e\n\u003cp data-start=\"7235\" data-end=\"7246\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7248\" data-end=\"7251\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7253\" data-end=\"7263\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7265\" data-end=\"7297\"\u003e\u003cstrong data-start=\"7265\" data-end=\"7297\"\u003e1 Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282465583426,"sku":null,"price":7590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/bc-3f1.png?v=1773585005","url":"https:\/\/summitsupplydirect.com\/products\/across-international-bc-3f-110-nsf-certified-3-ft-class-ii-type-a2-biosafety-cabinet","provider":"Summit Supply Direct","version":"1.0","type":"link"}