{"product_id":"across-international-b25-20l-ai-25-c-vip-insulated-20l-shipping-cube-with-rechargeable-pcm","title":"Across International B25-20L Ai -25°C VIP Insulated 20L Shipping Cube with Rechargeable PCM","description":"\u003cp data-start=\"391\" data-end=\"850\"\u003eThe \u003cstrong data-start=\"395\" data-end=\"452\"\u003eAcross International Ai B25-20L Thermal Shipping Cube\u003c\/strong\u003e is designed for \u003cstrong data-start=\"469\" data-end=\"592\"\u003esecure, temperature-controlled transport of sensitive materials requiring ultra-cold conditions between -25°C and -15°C\u003c\/strong\u003e. This \u003cstrong data-start=\"599\" data-end=\"635\"\u003eVIP-insulated shipping container\u003c\/strong\u003e utilizes \u003cstrong data-start=\"645\" data-end=\"699\"\u003erechargeable Phase Change Material (PCM) cold pads\u003c\/strong\u003e to maintain a stable temperature environment for up to \u003cstrong data-start=\"755\" data-end=\"767\"\u003e72 hours\u003c\/strong\u003e, ensuring safe transportation of valuable biological and pharmaceutical materials.\u003c\/p\u003e\n\u003cp data-start=\"852\" data-end=\"1252\"\u003eConstructed with \u003cstrong data-start=\"869\" data-end=\"921\"\u003eadvanced Vacuum Insulated Panel (VIP) technology\u003c\/strong\u003e, the shipping cube provides exceptional thermal performance. VIP insulation features a \u003cstrong data-start=\"1009\" data-end=\"1053\"\u003ethermal conductivity of only 0.004 W\/m·K\u003c\/strong\u003e, which is less than \u003cstrong data-start=\"1074\" data-end=\"1125\"\u003e20% of traditional polyurethane foam insulation\u003c\/strong\u003e, making it widely used in \u003cstrong data-start=\"1152\" data-end=\"1251\"\u003eultra-low temperature freezers, pharmaceutical cold chain logistics, and aerospace applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1254\" data-end=\"1483\"\u003eThis \u003cstrong data-start=\"1259\" data-end=\"1301\"\u003ereusable cold chain shipping container\u003c\/strong\u003e is ideal for transporting \u003cstrong data-start=\"1328\" data-end=\"1435\"\u003eclinical trial materials, vaccines, pharmaceutical products, laboratory samples, and research materials\u003c\/strong\u003e where precise temperature control is essential.\u003c\/p\u003e\n\u003chr data-start=\"1485\" data-end=\"1488\"\u003e\n\u003ch1 data-start=\"1490\" data-end=\"1504\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1506\" data-end=\"1981\"\u003e• \u003cstrong data-start=\"1508\" data-end=\"1557\"\u003eMaintains temperature between -25°C and -15°C\u003c\/strong\u003e\u003cbr data-start=\"1557\" data-end=\"1560\"\u003e• \u003cstrong data-start=\"1562\" data-end=\"1606\"\u003eUp to 72 hours of temperature protection\u003c\/strong\u003e\u003cbr data-start=\"1606\" data-end=\"1609\"\u003e• \u003cstrong data-start=\"1611\" data-end=\"1654\"\u003eIncludes six rechargeable PCM cold pads\u003c\/strong\u003e\u003cbr data-start=\"1654\" data-end=\"1657\"\u003e• \u003cstrong data-start=\"1659\" data-end=\"1726\"\u003eVacuum Insulated Panel (VIP) technology for superior insulation\u003c\/strong\u003e\u003cbr data-start=\"1726\" data-end=\"1729\"\u003e• \u003cstrong data-start=\"1731\" data-end=\"1787\"\u003eReusable and recyclable cold chain shipping solution\u003c\/strong\u003e\u003cbr data-start=\"1787\" data-end=\"1790\"\u003e• \u003cstrong data-start=\"1792\" data-end=\"1842\"\u003eIdeal for domestic and international shipments\u003c\/strong\u003e\u003cbr data-start=\"1842\" data-end=\"1845\"\u003e• \u003cstrong data-start=\"1847\" data-end=\"1918\"\u003eReliable temperature protection for high-value biological materials\u003c\/strong\u003e\u003cbr data-start=\"1918\" data-end=\"1921\"\u003e• \u003cstrong data-start=\"1923\" data-end=\"1981\"\u003eCompact, lightweight design for reduced shipping costs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1983\" data-end=\"1986\"\u003e\n\u003ch1 data-start=\"1988\" data-end=\"2008\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"2010\" data-end=\"2082\"\u003eThe Ai PCM Thermal Shipping Cube is designed for safe transportation of:\u003c\/p\u003e\n\u003cp data-start=\"2084\" data-end=\"2280\"\u003e• Vaccines\u003cbr data-start=\"2094\" data-end=\"2097\"\u003e• Clinical trial materials\u003cbr data-start=\"2123\" data-end=\"2126\"\u003e• Pharmaceutical products\u003cbr data-start=\"2151\" data-end=\"2154\"\u003e• Biological samples\u003cbr data-start=\"2174\" data-end=\"2177\"\u003e• Laboratory reagents\u003cbr data-start=\"2198\" data-end=\"2201\"\u003e• Research and development shipments\u003cbr data-start=\"2237\" data-end=\"2240\"\u003e• Temperature-sensitive medical supplies\u003c\/p\u003e\n\u003cp data-start=\"2282\" data-end=\"2393\"\u003eThis system is commonly used in \u003cstrong data-start=\"2314\" data-end=\"2392\"\u003epharmaceutical logistics, biotechnology research, and medical laboratories\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2395\" data-end=\"2398\"\u003e\n\u003ch1 data-start=\"2400\" data-end=\"2425\"\u003eTemperature Performance\u003c\/h1\u003e\n\u003cp data-start=\"2427\" data-end=\"2464\"\u003eTemperature Range: \u003cstrong data-start=\"2446\" data-end=\"2464\"\u003e-25°C to -15°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2466\" data-end=\"2496\"\u003eMinimum Temperature: \u003cstrong data-start=\"2487\" data-end=\"2496\"\u003e-25°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2498\" data-end=\"2538\"\u003eTemperature Duration: \u003cstrong data-start=\"2520\" data-end=\"2538\"\u003eUp to 72 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2540\" data-end=\"2679\"\u003eThe system is designed to maintain stable cold chain conditions even during \u003cstrong data-start=\"2616\" data-end=\"2678\"\u003eunexpected shipping delays or extreme ambient temperatures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"2681\" data-end=\"2684\"\u003e\n\u003ch1 data-start=\"2686\" data-end=\"2709\"\u003eCapacity \u0026amp; Dimensions\u003c\/h1\u003e\n\u003cp data-start=\"2711\" data-end=\"2763\"\u003eInterior Chamber Dimensions: \u003cstrong data-start=\"2740\" data-end=\"2763\"\u003e10 x 10 x 10 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2765\" data-end=\"2812\"\u003eInternal Volume: \u003cstrong data-start=\"2782\" data-end=\"2812\"\u003e20 liters (0.7 cubic feet)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2814\" data-end=\"2873\"\u003eUsable Volume After Cold Pads Installed: \u003cstrong data-start=\"2855\" data-end=\"2873\"\u003e0.6 cubic feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"2875\" data-end=\"2878\"\u003e\n\u003ch1 data-start=\"2880\" data-end=\"2895\"\u003ePCM Cold Pads\u003c\/h1\u003e\n\u003cp data-start=\"2897\" data-end=\"2922\"\u003eIncluded Cold Pads: \u003cstrong data-start=\"2917\" data-end=\"2922\"\u003e6\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2924\" data-end=\"2970\"\u003eThermal Fluid: \u003cstrong data-start=\"2939\" data-end=\"2970\"\u003ePhase Change Material (PCM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2972\" data-end=\"2987\"\u003eColor: \u003cstrong data-start=\"2979\" data-end=\"2987\"\u003eBlue\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2989\" data-end=\"3036\"\u003eOperating Temperature Range: \u003cstrong data-start=\"3018\" data-end=\"3036\"\u003e-25°C to -15°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3038\" data-end=\"3090\"\u003eCold Pad Dimensions: \u003cstrong data-start=\"3059\" data-end=\"3090\"\u003e10.25 x 10.25 x 0.75 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3092\" data-end=\"3113\"\u003eRechargeable: \u003cstrong data-start=\"3106\" data-end=\"3113\"\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3115\" data-end=\"3118\"\u003e\n\u003ch1 data-start=\"3120\" data-end=\"3139\"\u003eInsulation System\u003c\/h1\u003e\n\u003cp data-start=\"3141\" data-end=\"3190\"\u003eInsulation Type: \u003cstrong data-start=\"3158\" data-end=\"3190\"\u003eVacuum Insulated Panel (VIP)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3192\" data-end=\"3211\"\u003eTotal Panels: \u003cstrong data-start=\"3206\" data-end=\"3211\"\u003e6\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3213\" data-end=\"3240\"\u003ePanel Thickness: \u003cstrong data-start=\"3230\" data-end=\"3240\"\u003e1 inch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3242\" data-end=\"3279\"\u003eThermal Conductivity: \u003cstrong data-start=\"3264\" data-end=\"3279\"\u003e0.004 W\/m·K\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3281\" data-end=\"3460\"\u003eVIP insulation provides \u003cstrong data-start=\"3305\" data-end=\"3376\"\u003esuperior thermal protection compared to traditional foam insulation\u003c\/strong\u003e, helping maintain consistent internal temperatures for extended shipping durations.\u003c\/p\u003e\n\u003chr data-start=\"3462\" data-end=\"3465\"\u003e\n\u003ch1 data-start=\"3467\" data-end=\"3515\"\u003eStandard Operating Procedure (Recommended Use)\u003c\/h1\u003e\n\u003ch3 data-start=\"3517\" data-end=\"3543\"\u003eCharging PCM Cold Pads\u003c\/h3\u003e\n\u003cp data-start=\"3545\" data-end=\"3568\"\u003e\u003cstrong data-start=\"3545\" data-end=\"3568\"\u003eFor -25°C Shipping:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-start=\"3570\" data-end=\"3794\"\u003e\n\u003cli data-start=\"3570\" data-end=\"3630\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3630\"\u003ePlace PCM cold pads in a \u003cstrong data-start=\"3598\" data-end=\"3628\"\u003e-40°C freezer for 24 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3631\" data-end=\"3676\"\u003e\n\u003cp data-start=\"3634\" data-end=\"3676\"\u003ePosition pads \u003cstrong data-start=\"3648\" data-end=\"3674\"\u003esideways (not upright)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3677\" data-end=\"3728\"\u003e\n\u003cp data-start=\"3680\" data-end=\"3728\"\u003eLeave \u003cstrong data-start=\"3686\" data-end=\"3726\"\u003eat least 1 inch spacing between pads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3729\" data-end=\"3794\"\u003e\n\u003cp data-start=\"3732\" data-end=\"3794\"\u003ePCM is fully charged when the internal fluid becomes \u003cstrong data-start=\"3785\" data-end=\"3794\"\u003esolid\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"3796\" data-end=\"3824\"\u003eAfter removing from freezer:\u003c\/p\u003e\n\u003cp data-start=\"3826\" data-end=\"3909\"\u003e• Allow pads to sit at \u003cstrong data-start=\"3849\" data-end=\"3909\"\u003eroom temperature for approximately 15 minutes before use\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3911\" data-end=\"3914\"\u003e\n\u003ch3 data-start=\"3916\" data-end=\"3937\"\u003ePacking Procedure\u003c\/h3\u003e\n\u003col data-start=\"3939\" data-end=\"4242\"\u003e\n\u003cli data-start=\"3939\" data-end=\"3996\"\u003e\n\u003cp data-start=\"3942\" data-end=\"3996\"\u003ePlace \u003cstrong data-start=\"3948\" data-end=\"3994\"\u003eone PCM pad on the bottom of the container\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3997\" data-end=\"4047\"\u003e\n\u003cp data-start=\"4000\" data-end=\"4047\"\u003ePlace \u003cstrong data-start=\"4006\" data-end=\"4045\"\u003efour PCM pads along the inner walls\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4048\" data-end=\"4095\"\u003e\n\u003cp data-start=\"4051\" data-end=\"4095\"\u003eInsert the product load into the container\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4096\" data-end=\"4147\"\u003e\n\u003cp data-start=\"4099\" data-end=\"4147\"\u003ePlace a \u003cstrong data-start=\"4107\" data-end=\"4145\"\u003etemperature data logger (optional)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4148\" data-end=\"4199\"\u003e\n\u003cp data-start=\"4151\" data-end=\"4199\"\u003ePlace the \u003cstrong data-start=\"4161\" data-end=\"4197\"\u003esixth PCM pad on top of the load\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4200\" data-end=\"4242\"\u003e\n\u003cp data-start=\"4203\" data-end=\"4242\"\u003eClose the \u003cstrong data-start=\"4213\" data-end=\"4242\"\u003eVIP insulated lid tightly\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"4244\" data-end=\"4360\"\u003eAfter \u003cstrong data-start=\"4250\" data-end=\"4262\"\u003e72 hours\u003c\/strong\u003e, replace all PCM pads with \u003cstrong data-start=\"4290\" data-end=\"4314\"\u003efreshly charged pads\u003c\/strong\u003e if continued temperature control is required.\u003c\/p\u003e\n\u003chr data-start=\"4362\" data-end=\"4365\"\u003e\n\u003ch1 data-start=\"4367\" data-end=\"4402\"\u003eShipping Container Specifications\u003c\/h1\u003e\n\u003cp data-start=\"4404\" data-end=\"4429\"\u003eModel Number: \u003cstrong data-start=\"4418\" data-end=\"4429\"\u003eB25-20L\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4431\" data-end=\"4449\"\u003eWeight: \u003cstrong data-start=\"4439\" data-end=\"4449\"\u003e25 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4451\" data-end=\"4509\"\u003eExternal Dimensions: \u003cstrong data-start=\"4472\" data-end=\"4509\"\u003e16 x 13.5 x 14 inches (W x D x H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4511\" data-end=\"4560\"\u003eConstruction: \u003cstrong data-start=\"4525\" data-end=\"4560\"\u003eVIP insulated thermal container\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4562\" data-end=\"4579\"\u003eReusable: \u003cstrong data-start=\"4572\" data-end=\"4579\"\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4581\" data-end=\"4600\"\u003eRecyclable: \u003cstrong data-start=\"4593\" data-end=\"4600\"\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4602\" data-end=\"4605\"\u003e\n\u003ch1 data-start=\"4607\" data-end=\"4657\"\u003eAdvantages Over Traditional Cold Chain Packaging\u003c\/h1\u003e\n\u003cp data-start=\"4659\" data-end=\"4887\"\u003e• Lower shipping costs due to compact design\u003cbr data-start=\"4703\" data-end=\"4706\"\u003e• Longer temperature hold times than foam containers\u003cbr data-start=\"4758\" data-end=\"4761\"\u003e• Reusable PCM cold packs reduce long-term shipping costs\u003cbr data-start=\"4818\" data-end=\"4821\"\u003e• Reliable protection for sensitive medical and research materials\u003c\/p\u003e\n\u003chr data-start=\"4889\" data-end=\"4892\"\u003e\n\u003ch1 data-start=\"4894\" data-end=\"4911\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cp data-start=\"4913\" data-end=\"4951\"\u003e• \u003cstrong data-start=\"4915\" data-end=\"4951\"\u003eAi B25-20L Thermal Shipping Cube\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4953\" data-end=\"4993\"\u003e• \u003cstrong data-start=\"4955\" data-end=\"4993\"\u003eSix PCM cold pads (-25°C to -15°C)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4995\" data-end=\"5020\"\u003e• VIP insulated container\u003c\/p\u003e\n\u003chr data-start=\"5022\" data-end=\"5025\"\u003e\n\u003ch1 data-start=\"5027\" data-end=\"5037\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5039\" data-end=\"5071\"\u003e\u003cstrong data-start=\"5039\" data-end=\"5071\"\u003e1 Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52255833522498,"sku":null,"price":710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/b25-20l-inside_cut_b25-20l_1.jpg?v=1773024679","url":"https:\/\/summitsupplydirect.com\/products\/across-international-b25-20l-ai-25-c-vip-insulated-20l-shipping-cube-with-rechargeable-pcm","provider":"Summit Supply Direct","version":"1.0","type":"link"}