{"product_id":"across-international-as-220-x7-radwag-220g-capacity-0-1mg-readability-o4-analytical-balance-as-x7","title":"Across International AS 220.X7 Radwag 220g Capacity 0.1mg Readability ø4\" Analytical Balance AS X7","description":"\u003ch2 data-section-id=\"almo08\" data-start=\"403\" data-end=\"486\"\u003eHigh-Precision Analytical Balance with SMARTLab System and Touchscreen Interface\u003c\/h2\u003e\n\u003cp data-start=\"488\" data-end=\"822\"\u003eThe \u003cstrong data-start=\"492\" data-end=\"531\"\u003eRadwag AS 220.X7 Analytical Balance\u003c\/strong\u003e is a high-performance laboratory weighing instrument designed for \u003cstrong data-start=\"598\" data-end=\"671\"\u003eprecise mass determination with 0.1 mg readability and 220 g capacity\u003c\/strong\u003e. Built for professional analytical applications, the AS X7 series delivers excellent repeatability, high resolution, and advanced measurement control.\u003c\/p\u003e\n\u003cp data-start=\"824\" data-end=\"1217\"\u003eDesigned for laboratories in \u003cstrong data-start=\"853\" data-end=\"929\"\u003epharmacy, chemistry, physics, biology, medicine, and research facilities\u003c\/strong\u003e, this analytical balance combines precision engineering with modern smart technologies. The balance features a \u003cstrong data-start=\"1041\" data-end=\"1174\"\u003ecolor touchscreen interface, internal automatic calibration, LevelSENSING system, and SMARTLab measurement supervision technology\u003c\/strong\u003e to ensure reliable and repeatable results.\u003c\/p\u003e\n\u003cp data-start=\"1219\" data-end=\"1409\"\u003eWith advanced connectivity including \u003cstrong data-start=\"1256\" data-end=\"1291\"\u003eUSB, RS232, Ethernet, and Wi-Fi\u003c\/strong\u003e, the AS 220.X7 integrates easily into modern laboratory information systems and digital data management environments.\u003c\/p\u003e\n\u003chr data-start=\"1411\" data-end=\"1414\"\u003e\n\u003ch1 data-section-id=\"6zrs6l\" data-start=\"1416\" data-end=\"1473\"\u003eKey Features of the Radwag AS 220.X7 Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"7q2mrz\" data-start=\"1475\" data-end=\"1513\"\u003eHigh-Precision Analytical Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1514\" data-end=\"1636\"\u003eProvides \u003cstrong data-start=\"1523\" data-end=\"1565\"\u003e220 g capacity with 0.1 mg readability\u003c\/strong\u003e, making it ideal for accurate laboratory measurements of small masses.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gf5gh2\" data-start=\"1638\" data-end=\"1669\"\u003eErgonomic Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"1670\" data-end=\"1794\"\u003eThe spacious weighing chamber allows easy access to the weighing pan and accommodates laboratory glassware of various sizes.\u003c\/p\u003e\n\u003cp data-start=\"1796\" data-end=\"1954\"\u003eThe new \u003cstrong data-start=\"1804\" data-end=\"1853\"\u003ealuminum base construction improves stability\u003c\/strong\u003e, while innovative mechanical design increases durability and reliability during long-term operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2o7ypr\" data-start=\"1956\" data-end=\"1987\"\u003eDual-CLICK Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"1988\" data-end=\"2118\"\u003eThe \u003cstrong data-start=\"1992\" data-end=\"2013\"\u003eDual-CLICK system\u003c\/strong\u003e allows tool-free assembly and disassembly of the weighing chamber, simplifying cleaning and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"2120\" data-end=\"2203\"\u003eSpecial rim-free pane guides help maintain cleanliness inside the weighing chamber.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cg08g8\" data-start=\"2205\" data-end=\"2234\"\u003eColor Touchscreen Display\u003c\/h3\u003e\n\u003cp data-start=\"2235\" data-end=\"2340\"\u003eThe modern \u003cstrong data-start=\"2246\" data-end=\"2275\"\u003ecolor touchscreen display\u003c\/strong\u003e allows intuitive operation even while wearing laboratory gloves.\u003c\/p\u003e\n\u003cp data-start=\"2342\" data-end=\"2485\"\u003eCustomizable widgets and configurable buttons allow users to personalize the interface for faster access to frequently used weighing functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8umyam\" data-start=\"2487\" data-end=\"2510\"\u003eLevelSENSING System\u003c\/h3\u003e\n\u003cp data-start=\"2511\" data-end=\"2648\"\u003eThe integrated \u003cstrong data-start=\"2526\" data-end=\"2549\"\u003eLevelSENSING system\u003c\/strong\u003e monitors tilt using built-in sensors and displays a graphical warning if the balance is not level.\u003c\/p\u003e\n\u003cp data-start=\"2650\" data-end=\"2748\"\u003eThis ensures compliance with \u003cstrong data-start=\"2679\" data-end=\"2707\"\u003eGLP and GMP requirements\u003c\/strong\u003e while improving measurement reliability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1felwie\" data-start=\"2750\" data-end=\"2784\"\u003eInternal Automatic Calibration\u003c\/h3\u003e\n\u003cp data-start=\"2785\" data-end=\"2924\"\u003eInternal automatic adjustment compensates for environmental changes and ensures high accuracy even under challenging laboratory conditions.\u003c\/p\u003e\n\u003chr data-start=\"2926\" data-end=\"2929\"\u003e\n\u003ch1 data-section-id=\"1ws28l4\" data-start=\"2931\" data-end=\"2972\"\u003eSMARTLab Intelligent Measurement System\u003c\/h1\u003e\n\u003cp data-start=\"2974\" data-end=\"3085\"\u003eThe \u003cstrong data-start=\"2978\" data-end=\"2997\"\u003eSMARTLab system\u003c\/strong\u003e supervises the weighing process and reduces measurement errors caused by human factors.\u003c\/p\u003e\n\u003ch3 data-section-id=\"710qs4\" data-start=\"3087\" data-end=\"3111\"\u003eAutomatic Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3112\" data-end=\"3220\"\u003eInternal calibration automatically compensates for environmental changes and maintains measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o1yr05\" data-start=\"3222\" data-end=\"3245\"\u003eData Access Control\u003c\/h3\u003e\n\u003cp data-start=\"3246\" data-end=\"3343\"\u003eUser access is managed through multiple permission levels controlled by the system administrator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1bdb61b\" data-start=\"3345\" data-end=\"3369\"\u003eTouch-Free Operation\u003c\/h3\u003e\n\u003cp data-start=\"3370\" data-end=\"3487\"\u003eProgrammable sensors allow contactless operation of selected functions to improve workflow and prevent contamination.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ndwwwh\" data-start=\"3489\" data-end=\"3519\"\u003eAutomatic Weighing Records\u003c\/h3\u003e\n\u003cp data-start=\"3520\" data-end=\"3633\"\u003eMeasurement reports and weighing records can be automatically generated and exported to external devices via USB.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3635\" data-end=\"3651\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3652\" data-end=\"3775\"\u003eIntegrated \u003cstrong data-start=\"3663\" data-end=\"3710\"\u003eALIBI memory stores up to 500,000 weighings\u003c\/strong\u003e, ensuring long-term traceability and secure measurement records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tmn3z3\" data-start=\"3777\" data-end=\"3799\"\u003eWi-Fi Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3800\" data-end=\"3903\"\u003eBalances can be remotely controlled via devices running \u003cstrong data-start=\"3856\" data-end=\"3884\"\u003eAndroid, iOS, or Windows\u003c\/strong\u003e operating systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11v9zm\" data-start=\"3905\" data-end=\"3938\"\u003eAmbient Conditions Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"3939\" data-end=\"4077\"\u003eThe balance can communicate with a \u003cstrong data-start=\"3974\" data-end=\"4007\"\u003eRADWAG thermo-hygro-barometer\u003c\/strong\u003e to monitor environmental conditions such as temperature and humidity.\u003c\/p\u003e\n\u003chr data-start=\"4079\" data-end=\"4082\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"4084\" data-end=\"4119\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"4121\" data-end=\"4225\"\u003eThe AS X7 series includes a comprehensive database system supporting multi-user laboratory environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"4227\" data-end=\"4248\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"4250\" data-end=\"4574\"\u003e\n\u003cli data-section-id=\"b33a4d\" data-start=\"4250\" data-end=\"4279\"\u003e\n\u003cp data-start=\"4252\" data-end=\"4279\"\u003e\u003cstrong data-start=\"4252\" data-end=\"4265\"\u003eProducts:\u003c\/strong\u003e up to 5,000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k43mgv\" data-start=\"4280\" data-end=\"4304\"\u003e\n\u003cp data-start=\"4282\" data-end=\"4304\"\u003e\u003cstrong data-start=\"4282\" data-end=\"4292\"\u003eUsers:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cyfqnd\" data-start=\"4305\" data-end=\"4339\"\u003e\n\u003cp data-start=\"4307\" data-end=\"4339\"\u003e\u003cstrong data-start=\"4307\" data-end=\"4327\"\u003ePackaging types:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2wr2gm\" data-start=\"4340\" data-end=\"4370\"\u003e\n\u003cp data-start=\"4342\" data-end=\"4370\"\u003e\u003cstrong data-start=\"4342\" data-end=\"4356\"\u003eCustomers:\u003c\/strong\u003e up to 1,000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10dobr0\" data-start=\"4371\" data-end=\"4402\"\u003e\n\u003cp data-start=\"4373\" data-end=\"4402\"\u003e\u003cstrong data-start=\"4373\" data-end=\"4390\"\u003eFormulations:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nhfhhy\" data-start=\"4403\" data-end=\"4441\"\u003e\n\u003cp data-start=\"4405\" data-end=\"4441\"\u003e\u003cstrong data-start=\"4405\" data-end=\"4429\"\u003eFormulation reports:\u003c\/strong\u003e up to 500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sl9sgn\" data-start=\"4442\" data-end=\"4490\"\u003e\n\u003cp data-start=\"4444\" data-end=\"4490\"\u003e\u003cstrong data-start=\"4444\" data-end=\"4467\"\u003eAmbient conditions:\u003c\/strong\u003e up to 10,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11gcgwc\" data-start=\"4491\" data-end=\"4530\"\u003e\n\u003cp data-start=\"4493\" data-end=\"4530\"\u003e\u003cstrong data-start=\"4493\" data-end=\"4507\"\u003eWeighings:\u003c\/strong\u003e up to 50,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vrmwae\" data-start=\"4531\" data-end=\"4574\"\u003e\n\u003cp data-start=\"4533\" data-end=\"4574\"\u003e\u003cstrong data-start=\"4533\" data-end=\"4550\"\u003eALIBI memory:\u003c\/strong\u003e up to 512,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4576\" data-end=\"4668\"\u003eThese databases enable advanced analysis and traceability of laboratory weighing operations.\u003c\/p\u003e\n\u003chr data-start=\"4670\" data-end=\"4673\"\u003e\n\u003ch1 data-section-id=\"1409pu0\" data-start=\"4675\" data-end=\"4707\"\u003eCommunication and Connectivity\u003c\/h1\u003e\n\u003cp data-start=\"4709\" data-end=\"4785\"\u003eThe AS 220.X7 analytical balance supports multiple communication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4787\" data-end=\"4849\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"4787\" data-end=\"4798\"\u003e\n\u003cp data-start=\"4789\" data-end=\"4798\"\u003e\u003cstrong data-start=\"4789\" data-end=\"4798\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4799\" data-end=\"4810\"\u003e\n\u003cp data-start=\"4801\" data-end=\"4810\"\u003e\u003cstrong data-start=\"4801\" data-end=\"4810\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4811\" data-end=\"4822\"\u003e\n\u003cp data-start=\"4813\" data-end=\"4822\"\u003e\u003cstrong data-start=\"4813\" data-end=\"4822\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"4823\" data-end=\"4837\"\u003e\n\u003cp data-start=\"4825\" data-end=\"4837\"\u003e\u003cstrong data-start=\"4825\" data-end=\"4837\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"4838\" data-end=\"4849\"\u003e\n\u003cp data-start=\"4840\" data-end=\"4849\"\u003e\u003cstrong data-start=\"4840\" data-end=\"4849\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4851\" data-end=\"4930\"\u003eA front USB port enables fast data transfer and connection of external devices.\u003c\/p\u003e\n\u003cp data-start=\"4932\" data-end=\"5025\"\u003eThe balance also includes a \u003cstrong data-start=\"4960\" data-end=\"4984\"\u003eKensington Lock slot\u003c\/strong\u003e to protect against unauthorized removal.\u003c\/p\u003e\n\u003chr data-start=\"5027\" data-end=\"5030\"\u003e\n\u003ch1 data-section-id=\"n50ff3\" data-start=\"5032\" data-end=\"5051\"\u003eOptional Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"5053\" data-end=\"5075\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5076\" data-end=\"5180\"\u003eBalances manufactured after February 15, 2023 support under-pan weighing via an optional dedicated hook.\u003c\/p\u003e\n\u003ch3 data-section-id=\"z7ltoy\" data-start=\"5182\" data-end=\"5219\"\u003eTHBR 2.0 Environmental Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"5220\" data-end=\"5305\"\u003eCompatible with the \u003cstrong data-start=\"5240\" data-end=\"5259\"\u003eTHBR 2.0 system\u003c\/strong\u003e for monitoring ambient laboratory conditions.\u003c\/p\u003e\n\u003chr data-start=\"5307\" data-end=\"5310\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5312\" data-end=\"5332\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5334\" data-end=\"5392\"\u003eThe Radwag AS 220.X7 analytical balance is widely used in:\u003c\/p\u003e\n\u003cul data-start=\"5394\" data-end=\"5588\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"5394\" data-end=\"5425\"\u003e\n\u003cp data-start=\"5396\" data-end=\"5425\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"5426\" data-end=\"5460\"\u003e\n\u003cp data-start=\"5428\" data-end=\"5460\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"5461\" data-end=\"5493\"\u003e\n\u003cp data-start=\"5463\" data-end=\"5493\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1025s12\" data-start=\"5494\" data-end=\"5518\"\u003e\n\u003cp data-start=\"5496\" data-end=\"5518\"\u003eMedical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5519\" data-end=\"5551\"\u003e\n\u003cp data-start=\"5521\" data-end=\"5551\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2x2yph\" data-start=\"5552\" data-end=\"5588\"\u003e\n\u003cp data-start=\"5554\" data-end=\"5588\"\u003eScientific research institutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5590\" data-end=\"5593\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5595\" data-end=\"5621\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5623\" data-end=\"5631\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5632\" data-end=\"5645\"\u003e\u003cstrong data-start=\"5632\" data-end=\"5645\"\u003eAS 220.X7\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5647\" data-end=\"5675\"\u003ePart Number: \u003cstrong data-start=\"5660\" data-end=\"5675\"\u003eWL-113-0004\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5677\" data-end=\"5680\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5682\" data-end=\"5704\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5706\" data-end=\"5734\"\u003eMaximum capacity\u003cbr data-start=\"5722\" data-end=\"5725\"\u003e\u003cstrong data-start=\"5725\" data-end=\"5734\"\u003e220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5736\" data-end=\"5760\"\u003eMinimum load\u003cbr data-start=\"5748\" data-end=\"5751\"\u003e\u003cstrong data-start=\"5751\" data-end=\"5760\"\u003e10 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5762\" data-end=\"5786\"\u003eReadability\u003cbr data-start=\"5773\" data-end=\"5776\"\u003e\u003cstrong data-start=\"5776\" data-end=\"5786\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5788\" data-end=\"5820\"\u003eVerification unit (e)\u003cbr data-start=\"5809\" data-end=\"5812\"\u003e\u003cstrong data-start=\"5812\" data-end=\"5820\"\u003e1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5822\" data-end=\"5845\"\u003eTare range\u003cbr data-start=\"5832\" data-end=\"5835\"\u003e\u003cstrong data-start=\"5835\" data-end=\"5845\"\u003e−220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5847\" data-end=\"5850\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5852\" data-end=\"5862\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5864\" data-end=\"5900\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5886\" data-end=\"5889\"\u003e\u003cstrong data-start=\"5889\" data-end=\"5900\"\u003e0.06 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5902\" data-end=\"5935\"\u003eRepeatability (Max)\u003cbr data-start=\"5921\" data-end=\"5924\"\u003e\u003cstrong data-start=\"5924\" data-end=\"5935\"\u003e0.07 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5937\" data-end=\"5985\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"5971\" data-end=\"5974\"\u003e\u003cstrong data-start=\"5974\" data-end=\"5985\"\u003e0.09 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5987\" data-end=\"6031\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6018\" data-end=\"6021\"\u003e\u003cstrong data-start=\"6021\" data-end=\"6031\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6033\" data-end=\"6056\"\u003eLinearity\u003cbr data-start=\"6042\" data-end=\"6045\"\u003e\u003cstrong data-start=\"6045\" data-end=\"6056\"\u003e±0.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6058\" data-end=\"6092\"\u003eStabilization time\u003cbr data-start=\"6076\" data-end=\"6079\"\u003e\u003cstrong data-start=\"6079\" data-end=\"6092\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6094\" data-end=\"6097\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6099\" data-end=\"6122\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6124\" data-end=\"6155\"\u003eUSP minimum weight\u003cbr data-start=\"6142\" data-end=\"6145\"\u003e\u003cstrong data-start=\"6145\" data-end=\"6155\"\u003e120 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6157\" data-end=\"6199\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"6187\" data-end=\"6190\"\u003e\u003cstrong data-start=\"6190\" data-end=\"6199\"\u003e12 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6201\" data-end=\"6204\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6206\" data-end=\"6215\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6217\" data-end=\"6249\"\u003e\u003cstrong data-start=\"6217\" data-end=\"6249\"\u003eCapacitive color touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6251\" data-end=\"6254\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6256\" data-end=\"6270\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6272\" data-end=\"6304\"\u003eDiameter\u003cbr data-start=\"6280\" data-end=\"6283\"\u003e\u003cstrong data-start=\"6283\" data-end=\"6304\"\u003e4 inches (100 mm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6306\" data-end=\"6336\"\u003eMaterial\u003cbr data-start=\"6314\" data-end=\"6317\"\u003e\u003cstrong data-start=\"6317\" data-end=\"6336\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6338\" data-end=\"6341\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6343\" data-end=\"6357\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6359\" data-end=\"6384\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6386\" data-end=\"6448\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"6386\" data-end=\"6397\"\u003e\n\u003cp data-start=\"6388\" data-end=\"6397\"\u003e\u003cstrong data-start=\"6388\" data-end=\"6397\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6398\" data-end=\"6409\"\u003e\n\u003cp data-start=\"6400\" data-end=\"6409\"\u003e\u003cstrong data-start=\"6400\" data-end=\"6409\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6410\" data-end=\"6421\"\u003e\n\u003cp data-start=\"6412\" data-end=\"6421\"\u003e\u003cstrong data-start=\"6412\" data-end=\"6421\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"6422\" data-end=\"6436\"\u003e\n\u003cp data-start=\"6424\" data-end=\"6436\"\u003e\u003cstrong data-start=\"6424\" data-end=\"6436\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"6437\" data-end=\"6448\"\u003e\n\u003cp data-start=\"6439\" data-end=\"6448\"\u003e\u003cstrong data-start=\"6439\" data-end=\"6448\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6450\" data-end=\"6453\"\u003e\n\u003ch1 data-section-id=\"1u9wndv\" data-start=\"6455\" data-end=\"6464\"\u003eSensors\u003c\/h1\u003e\n\u003cp data-start=\"6466\" data-end=\"6513\"\u003e\u003cstrong data-start=\"6466\" data-end=\"6513\"\u003e2 infrared sensors for touch-free operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6515\" data-end=\"6518\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6520\" data-end=\"6540\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6542\" data-end=\"6567\"\u003e\u003cstrong data-start=\"6542\" data-end=\"6567\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6569\" data-end=\"6607\"\u003eMaximum power consumption\u003cbr data-start=\"6594\" data-end=\"6597\"\u003e\u003cstrong data-start=\"6597\" data-end=\"6607\"\u003e250 mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6609\" data-end=\"6612\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6614\" data-end=\"6636\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6638\" data-end=\"6677\"\u003eOperating temperature\u003cbr data-start=\"6659\" data-end=\"6662\"\u003e\u003cstrong data-start=\"6662\" data-end=\"6677\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6679\" data-end=\"6682\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6684\" data-end=\"6705\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6707\" data-end=\"6757\"\u003ePackage dimensions\u003cbr data-start=\"6725\" data-end=\"6728\"\u003e\u003cstrong data-start=\"6728\" data-end=\"6757\"\u003e19.5 × 15.5 × 20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6759\" data-end=\"6783\"\u003eUnit weight\u003cbr data-start=\"6770\" data-end=\"6773\"\u003e\u003cstrong data-start=\"6773\" data-end=\"6783\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6785\" data-end=\"6813\"\u003eShipping weight\u003cbr data-start=\"6800\" data-end=\"6803\"\u003e\u003cstrong data-start=\"6803\" data-end=\"6813\"\u003e21 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6815\" data-end=\"6818\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"6820\" data-end=\"6841\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"6843\" data-end=\"7011\"\u003e\n\u003cli data-section-id=\"1b4l0n5\" data-start=\"6843\" data-end=\"6886\"\u003e\n\u003cp data-start=\"6845\" data-end=\"6886\"\u003eRadwag AS 220.X7 Analytical Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yfw4sv\" data-start=\"6887\" data-end=\"6918\"\u003e\n\u003cp data-start=\"6889\" data-end=\"6918\"\u003eUniversal Power Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19f3x1w\" data-start=\"6919\" data-end=\"6947\"\u003e\n\u003cp data-start=\"6921\" data-end=\"6947\"\u003eDraft Shield for Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbmtyj\" data-start=\"6948\" data-end=\"6968\"\u003e\n\u003cp data-start=\"6950\" data-end=\"6968\"\u003ePan Assembly – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isa1dl\" data-start=\"6969\" data-end=\"6988\"\u003e\n\u003cp data-start=\"6971\" data-end=\"6988\"\u003eBalance Pad – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"6989\" data-end=\"7011\"\u003e\n\u003cp data-start=\"6991\" data-end=\"7011\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7013\" data-end=\"7016\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7018\" data-end=\"7028\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7030\" data-end=\"7062\"\u003e\u003cstrong data-start=\"7030\" data-end=\"7062\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282620936514,"sku":null,"price":2685.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/radwag_AS_X7_levelsensing4.png?v=1773590464","url":"https:\/\/summitsupplydirect.com\/products\/across-international-as-220-x7-radwag-220g-capacity-0-1mg-readability-o4-analytical-balance-as-x7","provider":"Summit Supply Direct","version":"1.0","type":"link"}