{"product_id":"across-international-as-120-r2-plus-radwag-120g-capacity-0-01mg-readability-o3-5-analytical-balance","title":"Across International AS 120.R2 PLUS Radwag 120g Capacity 0.01mg Readability ø3.5\" Analytical Balance","description":"\u003ch2 data-section-id=\"3i68pl\" data-start=\"390\" data-end=\"487\"\u003eUltra-High Precision Analytical Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"489\" data-end=\"927\"\u003eThe \u003cstrong data-start=\"493\" data-end=\"537\"\u003eRadwag AS 120.R2 PLUS Analytical Balance\u003c\/strong\u003e is a high-performance analytical weighing instrument designed for \u003cstrong data-start=\"604\" data-end=\"689\"\u003eultra-precise laboratory measurements with 0.01 mg readability and 120 g capacity\u003c\/strong\u003e. Part of the \u003cstrong data-start=\"703\" data-end=\"731\"\u003eSYNERGY LAB product line\u003c\/strong\u003e, the AS R2 PLUS series combines advanced mechanical design with intelligent data management and automation features to ensure \u003cstrong data-start=\"858\" data-end=\"926\"\u003emaximum measurement accuracy, reliability, and ease of operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"929\" data-end=\"1299\"\u003eThe spacious weighing chamber and \u003cstrong data-start=\"963\" data-end=\"993\"\u003eergonomic open-door design\u003c\/strong\u003e provide convenient access to the weighing pan, allowing the use of laboratory glassware of various sizes. A new \u003cstrong data-start=\"1106\" data-end=\"1136\"\u003ealuminum base construction\u003c\/strong\u003e enhances weighing stability, while the \u003cstrong data-start=\"1176\" data-end=\"1197\"\u003eDual-CLICK system\u003c\/strong\u003e enables tool-free assembly and disassembly of the weighing chamber for easy cleaning and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1301\" data-end=\"1634\"\u003eThe balance includes \u003cstrong data-start=\"1322\" data-end=\"1355\"\u003eautomatic internal adjustment\u003c\/strong\u003e, which compensates for environmental changes such as temperature fluctuations to maintain precise measurement results. Additionally, the \u003cstrong data-start=\"1493\" data-end=\"1545\"\u003eantistatic coating on the weighing chamber glass\u003c\/strong\u003e reduces electrostatic interference, improving weighing accuracy for ultra-light samples.\u003c\/p\u003e\n\u003cp data-start=\"1636\" data-end=\"1838\"\u003eEquipped with \u003cstrong data-start=\"1650\" data-end=\"1738\"\u003emultiple communication interfaces including RS232, USB, Ethernet, and optional Wi-Fi\u003c\/strong\u003e, the AS 120.R2 PLUS easily integrates with laboratory information systems, printers, and computers.\u003c\/p\u003e\n\u003chr data-start=\"1840\" data-end=\"1843\"\u003e\n\u003ch1 data-section-id=\"1k5e88r\" data-start=\"1845\" data-end=\"1907\"\u003eKey Features of the Radwag AS 120.R2 PLUS Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"popisn\" data-start=\"1909\" data-end=\"1945\"\u003eUltra-High Precision Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1946\" data-end=\"2081\"\u003eProvides \u003cstrong data-start=\"1955\" data-end=\"2006\"\u003e0.01 mg readability with 120 g maximum capacity\u003c\/strong\u003e, ideal for analytical laboratory applications requiring extreme precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11yfrj5\" data-start=\"2083\" data-end=\"2112\"\u003eSpacious Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2113\" data-end=\"2220\"\u003eLarge weighing chamber and wide door clearance allow convenient handling of laboratory vessels and samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1felwie\" data-start=\"2222\" data-end=\"2256\"\u003eInternal Automatic Calibration\u003c\/h3\u003e\n\u003cp data-start=\"2257\" data-end=\"2376\"\u003eModern internal adjustment system automatically compensates for environmental changes to maintain measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kevx82\" data-start=\"2378\" data-end=\"2407\"\u003eAnti-Static Glass Coating\u003c\/h3\u003e\n\u003cp data-start=\"2408\" data-end=\"2514\"\u003eSpecial \u003cstrong data-start=\"2416\" data-end=\"2443\"\u003eantistatic pane coating\u003c\/strong\u003e reduces electrostatic interference that could affect weighing results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t8icjt\" data-start=\"2516\" data-end=\"2553\"\u003eErgonomic Mechanical Construction\u003c\/h3\u003e\n\u003cp data-start=\"2554\" data-end=\"2625\"\u003eNew \u003cstrong data-start=\"2558\" data-end=\"2582\"\u003ealuminum base design\u003c\/strong\u003e improves balance stability and durability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zywr7y\" data-start=\"2627\" data-end=\"2656\"\u003eDual-CLICK Chamber System\u003c\/h3\u003e\n\u003cp data-start=\"2657\" data-end=\"2752\"\u003eAllows \u003cstrong data-start=\"2664\" data-end=\"2702\"\u003etool-free removal and installation\u003c\/strong\u003e of weighing chamber components for fast cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3o394\" data-start=\"2754\" data-end=\"2780\"\u003eFront Levelling System\u003c\/h3\u003e\n\u003cp data-start=\"2781\" data-end=\"2882\"\u003eTwo-point levelling system located at the front of the balance simplifies setup and level adjustment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"2884\" data-end=\"2907\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"2908\" data-end=\"3010\"\u003eClear \u003cstrong data-start=\"2914\" data-end=\"2937\"\u003ebacklit LCD display\u003c\/strong\u003e provides easy viewing of measurement results and additional information.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"3012\" data-end=\"3037\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3038\" data-end=\"3071\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"3073\" data-end=\"3158\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"3073\" data-end=\"3088\"\u003e\n\u003cp data-start=\"3075\" data-end=\"3088\"\u003e\u003cstrong data-start=\"3075\" data-end=\"3088\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"3089\" data-end=\"3105\"\u003e\n\u003cp data-start=\"3091\" data-end=\"3105\"\u003e\u003cstrong data-start=\"3091\" data-end=\"3105\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"3106\" data-end=\"3122\"\u003e\n\u003cp data-start=\"3108\" data-end=\"3122\"\u003e\u003cstrong data-start=\"3108\" data-end=\"3122\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"3123\" data-end=\"3137\"\u003e\n\u003cp data-start=\"3125\" data-end=\"3137\"\u003e\u003cstrong data-start=\"3125\" data-end=\"3137\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"3138\" data-end=\"3158\"\u003e\n\u003cp data-start=\"3140\" data-end=\"3158\"\u003e\u003cstrong data-start=\"3140\" data-end=\"3158\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3160\" data-end=\"3237\"\u003eA front USB port allows easy connection of flash drives and external devices.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pgakg8\" data-start=\"3239\" data-end=\"3258\"\u003eDevice Security\u003c\/h3\u003e\n\u003cp data-start=\"3259\" data-end=\"3333\"\u003eIntegrated \u003cstrong data-start=\"3270\" data-end=\"3294\"\u003eKensington Lock slot\u003c\/strong\u003e protects the instrument against theft.\u003c\/p\u003e\n\u003chr data-start=\"3335\" data-end=\"3338\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"3340\" data-end=\"3375\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"3377\" data-end=\"3489\"\u003eThe AS R2 PLUS series includes an advanced internal data system supporting multiple users and product databases.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"3491\" data-end=\"3512\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"3514\" data-end=\"3707\"\u003e\n\u003cli data-section-id=\"117fjp8\" data-start=\"3514\" data-end=\"3547\"\u003e\n\u003cp data-start=\"3516\" data-end=\"3547\"\u003e\u003cstrong data-start=\"3516\" data-end=\"3530\"\u003eOperators:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d70vn1\" data-start=\"3548\" data-end=\"3585\"\u003e\n\u003cp data-start=\"3550\" data-end=\"3585\"\u003e\u003cstrong data-start=\"3550\" data-end=\"3563\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r9m2z4\" data-start=\"3586\" data-end=\"3623\"\u003e\n\u003cp data-start=\"3588\" data-end=\"3623\"\u003e\u003cstrong data-start=\"3588\" data-end=\"3602\"\u003eWeighings:\u003c\/strong\u003e up to 5000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"3624\" data-end=\"3660\"\u003e\n\u003cp data-start=\"3626\" data-end=\"3660\"\u003e\u003cstrong data-start=\"3626\" data-end=\"3636\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g878ze\" data-start=\"3661\" data-end=\"3707\"\u003e\n\u003cp data-start=\"3663\" data-end=\"3707\"\u003e\u003cstrong data-start=\"3663\" data-end=\"3680\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3709\" data-end=\"3725\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3727\" data-end=\"3850\"\u003eThe built-in \u003cstrong data-start=\"3740\" data-end=\"3790\"\u003eALIBI memory securely records weighing results\u003c\/strong\u003e, ensuring long-term traceability and regulatory compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o5p3it\" data-start=\"3852\" data-end=\"3871\"\u003eData Protection\u003c\/h3\u003e\n\u003cp data-start=\"3873\" data-end=\"3992\"\u003eAccess to stored data requires user authentication, allowing administrators to manage user permissions and data access.\u003c\/p\u003e\n\u003chr data-start=\"3994\" data-end=\"3997\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3999\" data-end=\"4028\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"4030\" data-end=\"4114\"\u003eThe AS 120.R2 PLUS analytical balance supports multiple professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"4116\" data-end=\"4128\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"4129\" data-end=\"4248\"\u003eAutomatic diagnostic system verifying \u003cstrong data-start=\"4167\" data-end=\"4212\"\u003erepeatability and metrological parameters\u003c\/strong\u003e based on real operating conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"4250\" data-end=\"4260\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"4261\" data-end=\"4373\"\u003eAllows precise dosing based on \u003cstrong data-start=\"4292\" data-end=\"4332\"\u003ereference mass with tolerance limits\u003c\/strong\u003e, ideal for powders and liquid materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4375\" data-end=\"4395\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4396\" data-end=\"4474\"\u003eCompares sample mass to a reference mass and displays results as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"4476\" data-end=\"4490\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"4491\" data-end=\"4567\"\u003eAdds multiple measurements together to determine the total mass of mixtures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4569\" data-end=\"4587\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4588\" data-end=\"4679\"\u003eCalculates item quantity based on known unit weight with \u003cstrong data-start=\"4645\" data-end=\"4678\"\u003eautomatic accuracy correction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"4681\" data-end=\"4694\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"4695\" data-end=\"4772\"\u003eCaptures the \u003cstrong data-start=\"4708\" data-end=\"4747\"\u003ehighest temporary measurement value\u003c\/strong\u003e during dynamic weighing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u90ctf\" data-start=\"4774\" data-end=\"4788\"\u003eStatistics\u003c\/h3\u003e\n\u003cp data-start=\"4789\" data-end=\"4829\"\u003eProvides statistical analysis including:\u003c\/p\u003e\n\u003cul data-start=\"4831\" data-end=\"4937\"\u003e\n\u003cli data-section-id=\"tf72o5\" data-start=\"4831\" data-end=\"4861\"\u003e\n\u003cp data-start=\"4833\" data-end=\"4861\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"4862\" data-end=\"4879\"\u003e\n\u003cp data-start=\"4864\" data-end=\"4879\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"4880\" data-end=\"4902\"\u003e\n\u003cp data-start=\"4882\" data-end=\"4902\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"4903\" data-end=\"4915\"\u003e\n\u003cp data-start=\"4905\" data-end=\"4915\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"4916\" data-end=\"4937\"\u003e\n\u003cp data-start=\"4918\" data-end=\"4937\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4939\" data-end=\"4956\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4957\" data-end=\"5033\"\u003eDetermines whether a sample weight falls within predefined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"5035\" data-end=\"5057\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5058\" data-end=\"5143\"\u003eAllows suspended weighing of irregular objects or materials with magnetic properties.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"5145\" data-end=\"5164\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5165\" data-end=\"5235\"\u003eMeasures weight of moving samples by averaging measurements over time.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7ulzqj\" data-start=\"5237\" data-end=\"5262\"\u003eDensity Determination\u003c\/h3\u003e\n\u003cp data-start=\"5263\" data-end=\"5365\"\u003eDetermines density of solids and liquids using \u003cstrong data-start=\"5310\" data-end=\"5335\"\u003eArchimedes’ principle\u003c\/strong\u003e with an optional density kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"5367\" data-end=\"5384\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"5385\" data-end=\"5453\"\u003eSupports \u003cstrong data-start=\"5394\" data-end=\"5452\"\u003eGood Laboratory Practice (GLP) compliant documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5455\" data-end=\"5458\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5460\" data-end=\"5480\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5482\" data-end=\"5547\"\u003eThe Radwag AS 120.R2 PLUS analytical balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5549\" data-end=\"5750\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"5549\" data-end=\"5580\"\u003e\n\u003cp data-start=\"5551\" data-end=\"5580\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"5581\" data-end=\"5615\"\u003e\n\u003cp data-start=\"5583\" data-end=\"5615\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"5616\" data-end=\"5648\"\u003e\n\u003cp data-start=\"5618\" data-end=\"5648\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5649\" data-end=\"5681\"\u003e\n\u003cp data-start=\"5651\" data-end=\"5681\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pi1uj2\" data-start=\"5682\" data-end=\"5711\"\u003e\n\u003cp data-start=\"5684\" data-end=\"5711\"\u003eMaterial science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x51em9\" data-start=\"5712\" data-end=\"5750\"\u003e\n\u003cp data-start=\"5714\" data-end=\"5750\"\u003eIndustrial analytical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5752\" data-end=\"5755\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5757\" data-end=\"5783\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5785\" data-end=\"5793\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5794\" data-end=\"5812\"\u003e\u003cstrong data-start=\"5794\" data-end=\"5812\"\u003eAS 120.R2 PLUS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5814\" data-end=\"5842\"\u003ePart Number: \u003cstrong data-start=\"5827\" data-end=\"5842\"\u003eWL-104-0191\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5844\" data-end=\"5847\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5849\" data-end=\"5871\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5873\" data-end=\"5901\"\u003eMaximum capacity\u003cbr data-start=\"5889\" data-end=\"5892\"\u003e\u003cstrong data-start=\"5892\" data-end=\"5901\"\u003e120 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5903\" data-end=\"5926\"\u003eMinimum load\u003cbr data-start=\"5915\" data-end=\"5918\"\u003e\u003cstrong data-start=\"5918\" data-end=\"5926\"\u003e1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5928\" data-end=\"5953\"\u003eReadability\u003cbr data-start=\"5939\" data-end=\"5942\"\u003e\u003cstrong data-start=\"5942\" data-end=\"5953\"\u003e0.01 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5955\" data-end=\"5978\"\u003eTare range\u003cbr data-start=\"5965\" data-end=\"5968\"\u003e\u003cstrong data-start=\"5968\" data-end=\"5978\"\u003e−120 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5980\" data-end=\"5983\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5985\" data-end=\"5995\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5997\" data-end=\"6034\"\u003eRepeatability (5% Max)\u003cbr data-start=\"6019\" data-end=\"6022\"\u003e\u003cstrong data-start=\"6022\" data-end=\"6034\"\u003e0.015 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6036\" data-end=\"6069\"\u003eRepeatability (Max)\u003cbr data-start=\"6055\" data-end=\"6058\"\u003e\u003cstrong data-start=\"6058\" data-end=\"6069\"\u003e0.04 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6071\" data-end=\"6119\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"6105\" data-end=\"6108\"\u003e\u003cstrong data-start=\"6108\" data-end=\"6119\"\u003e0.02 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6121\" data-end=\"6166\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6152\" data-end=\"6155\"\u003e\u003cstrong data-start=\"6155\" data-end=\"6166\"\u003e0.05 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6168\" data-end=\"6192\"\u003eLinearity\u003cbr data-start=\"6177\" data-end=\"6180\"\u003e\u003cstrong data-start=\"6180\" data-end=\"6192\"\u003e±0.07 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6194\" data-end=\"6228\"\u003eStabilization time\u003cbr data-start=\"6212\" data-end=\"6215\"\u003e\u003cstrong data-start=\"6215\" data-end=\"6228\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6230\" data-end=\"6233\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6235\" data-end=\"6258\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6260\" data-end=\"6301\"\u003eStandard minimum weight (USP)\u003cbr data-start=\"6289\" data-end=\"6292\"\u003e\u003cstrong data-start=\"6292\" data-end=\"6301\"\u003e30 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6303\" data-end=\"6353\"\u003eStandard minimum weight (U = 1%, k = 2)\u003cbr data-start=\"6342\" data-end=\"6345\"\u003e\u003cstrong data-start=\"6345\" data-end=\"6353\"\u003e3 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6355\" data-end=\"6358\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"6360\" data-end=\"6372\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"6374\" data-end=\"6408\"\u003e\u003cstrong data-start=\"6374\" data-end=\"6408\"\u003eInternal automatic calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6410\" data-end=\"6413\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"6415\" data-end=\"6436\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"6438\" data-end=\"6449\"\u003e\u003cstrong data-start=\"6438\" data-end=\"6449\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6451\" data-end=\"6454\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6456\" data-end=\"6465\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6467\" data-end=\"6490\"\u003e\u003cstrong data-start=\"6467\" data-end=\"6490\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6492\" data-end=\"6495\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6497\" data-end=\"6511\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6513\" data-end=\"6538\"\u003eDiameter\u003cbr data-start=\"6521\" data-end=\"6524\"\u003e\u003cstrong data-start=\"6524\" data-end=\"6538\"\u003e3.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6540\" data-end=\"6570\"\u003eMaterial\u003cbr data-start=\"6548\" data-end=\"6551\"\u003e\u003cstrong data-start=\"6551\" data-end=\"6570\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6572\" data-end=\"6575\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6577\" data-end=\"6591\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6593\" data-end=\"6618\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6620\" data-end=\"6680\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"6620\" data-end=\"6635\"\u003e\n\u003cp data-start=\"6622\" data-end=\"6635\"\u003e\u003cstrong data-start=\"6622\" data-end=\"6635\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6636\" data-end=\"6647\"\u003e\n\u003cp data-start=\"6638\" data-end=\"6647\"\u003e\u003cstrong data-start=\"6638\" data-end=\"6647\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6648\" data-end=\"6659\"\u003e\n\u003cp data-start=\"6650\" data-end=\"6659\"\u003e\u003cstrong data-start=\"6650\" data-end=\"6659\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"6660\" data-end=\"6680\"\u003e\n\u003cp data-start=\"6662\" data-end=\"6680\"\u003e\u003cstrong data-start=\"6662\" data-end=\"6680\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6682\" data-end=\"6685\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6687\" data-end=\"6707\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6709\" data-end=\"6736\"\u003e\u003cstrong data-start=\"6709\" data-end=\"6736\"\u003e100 – 240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6738\" data-end=\"6741\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6743\" data-end=\"6765\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6767\" data-end=\"6806\"\u003eOperating temperature\u003cbr data-start=\"6788\" data-end=\"6791\"\u003e\u003cstrong data-start=\"6791\" data-end=\"6806\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6808\" data-end=\"6811\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6813\" data-end=\"6834\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6836\" data-end=\"6884\"\u003ePackage dimensions\u003cbr data-start=\"6854\" data-end=\"6857\"\u003e\u003cstrong data-start=\"6857\" data-end=\"6884\"\u003e19.5 × 15.5 × 20 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6886\" data-end=\"6910\"\u003eUnit weight\u003cbr data-start=\"6897\" data-end=\"6900\"\u003e\u003cstrong data-start=\"6900\" data-end=\"6910\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6912\" data-end=\"6940\"\u003eShipping weight\u003cbr data-start=\"6927\" data-end=\"6930\"\u003e\u003cstrong data-start=\"6930\" data-end=\"6940\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6942\" data-end=\"6945\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"6947\" data-end=\"6962\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"6964\" data-end=\"6982\"\u003e\u003cstrong data-start=\"6964\" data-end=\"6982\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6984\" data-end=\"6987\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"6989\" data-end=\"7010\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"7012\" data-end=\"7218\"\u003e\n\u003cli data-section-id=\"11ltq8n\" data-start=\"7012\" data-end=\"7060\"\u003e\n\u003cp data-start=\"7014\" data-end=\"7060\"\u003eRadwag AS 120.R2 PLUS Analytical Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g2t8jg\" data-start=\"7061\" data-end=\"7089\"\u003e\n\u003cp data-start=\"7063\" data-end=\"7089\"\u003eBalance Fabric Cover – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yfw4sv\" data-start=\"7090\" data-end=\"7121\"\u003e\n\u003cp data-start=\"7092\" data-end=\"7121\"\u003eUniversal Power Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbmtyj\" data-start=\"7122\" data-end=\"7142\"\u003e\n\u003cp data-start=\"7124\" data-end=\"7142\"\u003ePan Assembly – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1afvlpz\" data-start=\"7143\" data-end=\"7175\"\u003e\n\u003cp data-start=\"7145\" data-end=\"7175\"\u003ePan Draft Shields – 3 pieces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isa1dl\" data-start=\"7176\" data-end=\"7195\"\u003e\n\u003cp data-start=\"7178\" data-end=\"7195\"\u003eBalance Pad – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"7196\" data-end=\"7218\"\u003e\n\u003cp data-start=\"7198\" data-end=\"7218\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7220\" data-end=\"7223\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7225\" data-end=\"7235\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7237\" data-end=\"7269\"\u003e\u003cstrong data-start=\"7237\" data-end=\"7269\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282605568322,"sku":null,"price":3909.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/as_r2_plus_02_as-120-r2-plus--wl-104-0191-_1.jpg?v=1773589288","url":"https:\/\/summitsupplydirect.com\/products\/across-international-as-120-r2-plus-radwag-120g-capacity-0-01mg-readability-o3-5-analytical-balance","provider":"Summit Supply Direct","version":"1.0","type":"link"}