{"product_id":"across-international-acr1-110-biochromato-acr1-acid-resistant-bump-free-smart-evaporator","title":"Across International ACR1.110 BioChromato ACR1 Acid-Resistant Bump-Free Smart Evaporator","description":"\u003ch2 data-section-id=\"1abraqf\" data-start=\"430\" data-end=\"502\"\u003eAcid-Resistant Smart Evaporator for Safe Hydrolysis \u0026amp; Solvent Removal\u003c\/h2\u003e\n\u003cp data-start=\"504\" data-end=\"748\"\u003eThe \u003cstrong data-start=\"508\" data-end=\"560\"\u003eBioChromato ACR1 Acid-Resistant Smart Evaporator\u003c\/strong\u003e is a specialized \u003cstrong data-start=\"578\" data-end=\"610\"\u003ebump-free evaporation system\u003c\/strong\u003e designed for laboratories working with \u003cstrong data-start=\"650\" data-end=\"726\"\u003eacidic solvents, hydrochloric acid hydrolysis, and high-boiling solvents\u003c\/strong\u003e such as DMSO and DMF.\u003c\/p\u003e\n\u003cp data-start=\"750\" data-end=\"995\"\u003eUsing BioChromato’s proprietary \u003cstrong data-start=\"782\" data-end=\"839\"\u003eVacuum-Assisted Vortex Concentration (VVC) technology\u003c\/strong\u003e, the ACR1 creates a controlled vortex inside the sample container, allowing solvents and acids to evaporate efficiently \u003cstrong data-start=\"960\" data-end=\"994\"\u003ewithout bumping or sample loss\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"997\" data-end=\"1238\"\u003eThe device features \u003cstrong data-start=\"1017\" data-end=\"1085\"\u003eacid-resistant construction with fluorine-based resin components\u003c\/strong\u003e, making it ideal for applications involving \u003cstrong data-start=\"1130\" data-end=\"1237\"\u003eprotein hydrolysis, peptide hydrolysis, acidic solvent evaporation, and laboratory sample concentration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1240\" data-end=\"1514\"\u003eDesigned for flexibility, the ACR1 supports a wide variety of laboratory containers including \u003cstrong data-start=\"1334\" data-end=\"1396\"\u003eHPLC vials, Eppendorf tubes, conical tubes, and test tubes\u003c\/strong\u003e, allowing researchers to concentrate samples directly in their storage containers to minimize sample transfer losses.\u003c\/p\u003e\n\u003cp data-start=\"1516\" data-end=\"1675\"\u003eManufactured in \u003cstrong data-start=\"1532\" data-end=\"1556\"\u003eJapan by BioChromato\u003c\/strong\u003e, the ACR1 Smart Evaporator is widely used in \u003cstrong data-start=\"1602\" data-end=\"1674\"\u003epharmaceutical, food science, forensic, and biochemical laboratories\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1677\" data-end=\"1680\"\u003e\n\u003ch1 data-section-id=\"sjwc30\" data-start=\"1682\" data-end=\"1737\"\u003eKey Features of the BioChromato ACR1 Smart Evaporator\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1531w7b\" data-start=\"1739\" data-end=\"1764\"\u003eAcid-Resistant Design\u003c\/h3\u003e\n\u003cp data-start=\"1765\" data-end=\"1937\"\u003eThe gas-contacting components are constructed from \u003cstrong data-start=\"1816\" data-end=\"1872\"\u003efluorine-based resin with fluorine surface treatment\u003c\/strong\u003e, providing excellent resistance to corrosive acids and solvents.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16xbpqp\" data-start=\"1939\" data-end=\"1975\"\u003eBump-Free Evaporation Technology\u003c\/h3\u003e\n\u003cp data-start=\"1976\" data-end=\"2126\"\u003eBioChromato’s \u003cstrong data-start=\"1990\" data-end=\"2047\"\u003eVVC (Vacuum-Assisted Vortex Concentration) technology\u003c\/strong\u003e prevents solvent bumping and enables smooth evaporation under normal pressure.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1m1s5be\" data-start=\"2128\" data-end=\"2170\"\u003eIdeal for Acid Hydrolysis Applications\u003c\/h3\u003e\n\u003cp data-start=\"2171\" data-end=\"2306\"\u003eCommonly used for \u003cstrong data-start=\"2189\" data-end=\"2264\"\u003ehydrochloric acid hydrolysis of proteins, peptides, and other compounds\u003c\/strong\u003e requiring controlled solvent evaporation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"51lf4p\" data-start=\"2308\" data-end=\"2354\"\u003eEfficient Removal of High-Boiling Solvents\u003c\/h3\u003e\n\u003cp data-start=\"2355\" data-end=\"2407\"\u003eCapable of evaporating difficult solvents including:\u003c\/p\u003e\n\u003cul data-start=\"2409\" data-end=\"2467\"\u003e\n\u003cli data-section-id=\"9tcvj1\" data-start=\"2409\" data-end=\"2419\"\u003e\n\u003cp data-start=\"2411\" data-end=\"2419\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2419\"\u003eDMSO\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d7mm87\" data-start=\"2420\" data-end=\"2429\"\u003e\n\u003cp data-start=\"2422\" data-end=\"2429\"\u003e\u003cstrong data-start=\"2422\" data-end=\"2429\"\u003eDMF\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"199d3b1\" data-start=\"2430\" data-end=\"2441\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2441\"\u003e\u003cstrong data-start=\"2432\" data-end=\"2441\"\u003eWater\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10q3e4t\" data-start=\"2442\" data-end=\"2467\"\u003e\n\u003cp data-start=\"2444\" data-end=\"2467\"\u003eAcidic solvent mixtures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hh4wu\" data-start=\"2469\" data-end=\"2513\"\u003eCompatible with Multiple Container Types\u003c\/h3\u003e\n\u003cp data-start=\"2514\" data-end=\"2571\"\u003eSupports a wide range of laboratory containers including:\u003c\/p\u003e\n\u003cul data-start=\"2573\" data-end=\"2696\"\u003e\n\u003cli data-section-id=\"rifbpr\" data-start=\"2573\" data-end=\"2610\"\u003e\n\u003cp data-start=\"2575\" data-end=\"2610\"\u003e\u003cstrong data-start=\"2575\" data-end=\"2610\"\u003e1.5 mL \/ 2 mL HPLC sample vials\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"136gcdx\" data-start=\"2611\" data-end=\"2637\"\u003e\n\u003cp data-start=\"2613\" data-end=\"2637\"\u003e\u003cstrong data-start=\"2613\" data-end=\"2637\"\u003e5 mL and 20 mL vials\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"saqeq4\" data-start=\"2638\" data-end=\"2659\"\u003e\n\u003cp data-start=\"2640\" data-end=\"2659\"\u003e\u003cstrong data-start=\"2640\" data-end=\"2659\"\u003eEppendorf tubes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17rrrko\" data-start=\"2660\" data-end=\"2679\"\u003e\n\u003cp data-start=\"2662\" data-end=\"2679\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2679\"\u003eConical tubes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3d7y5n\" data-start=\"2680\" data-end=\"2696\"\u003e\n\u003cp data-start=\"2682\" data-end=\"2696\"\u003e\u003cstrong data-start=\"2682\" data-end=\"2696\"\u003eTest tubes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2698\" data-end=\"2800\"\u003eThis flexibility allows \u003cstrong data-start=\"2722\" data-end=\"2766\"\u003edirect in-container sample concentration\u003c\/strong\u003e, minimizing sample transfer loss.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n1ajjr\" data-start=\"2802\" data-end=\"2828\"\u003eSimplified Maintenance\u003c\/h3\u003e\n\u003cp data-start=\"2829\" data-end=\"2962\"\u003eThe gas contact system uses only \u003cstrong data-start=\"2862\" data-end=\"2924\"\u003etwo replaceable parts (Flow Control Valve and Spiral Plug)\u003c\/strong\u003e, making maintenance quick and simple.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mq3r1\" data-start=\"2964\" data-end=\"2992\"\u003eImproved Sample Recovery\u003c\/h3\u003e\n\u003cp data-start=\"2993\" data-end=\"3125\"\u003eBy concentrating samples directly inside storage containers, the system significantly \u003cstrong data-start=\"3079\" data-end=\"3124\"\u003ereduces sample loss during transfer steps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"3127\" data-end=\"3130\"\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"3132\" data-end=\"3154\"\u003eTypical Applications\u003c\/h1\u003e\n\u003cp data-start=\"3156\" data-end=\"3215\"\u003eThe BioChromato ACR1 Smart Evaporator is commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"3217\" data-end=\"3523\"\u003e\n\u003cli data-section-id=\"4jp8oa\" data-start=\"3217\" data-end=\"3259\"\u003e\n\u003cp data-start=\"3219\" data-end=\"3259\"\u003eHydrochloric acid hydrolysis of proteins\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xbq2te\" data-start=\"3260\" data-end=\"3285\"\u003e\n\u003cp data-start=\"3262\" data-end=\"3285\"\u003ePeptide bond hydrolysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o1z6sl\" data-start=\"3286\" data-end=\"3316\"\u003e\n\u003cp data-start=\"3288\" data-end=\"3316\"\u003eAcidic solvent concentration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ayahh3\" data-start=\"3317\" data-end=\"3349\"\u003e\n\u003cp data-start=\"3319\" data-end=\"3349\"\u003eRemoval of reaction impurities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ut4whc\" data-start=\"3350\" data-end=\"3399\"\u003e\n\u003cp data-start=\"3352\" data-end=\"3399\"\u003eReaction acceleration during chemical synthesis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i69hsa\" data-start=\"3400\" data-end=\"3447\"\u003e\n\u003cp data-start=\"3402\" data-end=\"3447\"\u003eSample concentration for analytical chemistry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xx9qm9\" data-start=\"3448\" data-end=\"3474\"\u003e\n\u003cp data-start=\"3450\" data-end=\"3474\"\u003epH adjustment procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lzzag3\" data-start=\"3475\" data-end=\"3523\"\u003e\n\u003cp data-start=\"3477\" data-end=\"3523\"\u003ePreparation of biological samples for analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3525\" data-end=\"3528\"\u003e\n\u003ch1 data-section-id=\"knfuej\" data-start=\"3530\" data-end=\"3553\"\u003eIdeal Research Fields\u003c\/h1\u003e\n\u003cp data-start=\"3555\" data-end=\"3599\"\u003eWidely used in laboratories specializing in:\u003c\/p\u003e\n\u003cul data-start=\"3601\" data-end=\"3727\"\u003e\n\u003cli data-section-id=\"25z60m\" data-start=\"3601\" data-end=\"3626\"\u003e\n\u003cp data-start=\"3603\" data-end=\"3626\"\u003ePharmaceutical research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15l7py6\" data-start=\"3627\" data-end=\"3641\"\u003e\n\u003cp data-start=\"3629\" data-end=\"3641\"\u003eFood science\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o1gt83\" data-start=\"3642\" data-end=\"3661\"\u003e\n\u003cp data-start=\"3644\" data-end=\"3661\"\u003eForensic analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ajyane\" data-start=\"3662\" data-end=\"3676\"\u003e\n\u003cp data-start=\"3664\" data-end=\"3676\"\u003eBiochemistry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s68vu9\" data-start=\"3677\" data-end=\"3696\"\u003e\n\u003cp data-start=\"3679\" data-end=\"3696\"\u003eOrganic chemistry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"t7gss3\" data-start=\"3697\" data-end=\"3727\"\u003e\n\u003cp data-start=\"3699\" data-end=\"3727\"\u003eProtein and peptide analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3729\" data-end=\"3732\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3734\" data-end=\"3760\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3762\" data-end=\"3770\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3771\" data-end=\"3808\"\u003e\u003cstrong data-start=\"3771\" data-end=\"3808\"\u003eBioChromato ACR1 Smart Evaporator\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3810\" data-end=\"3813\"\u003e\n\u003ch1 data-section-id=\"19z818b\" data-start=\"3815\" data-end=\"3831\"\u003eHeating System\u003c\/h1\u003e\n\u003cp data-start=\"3833\" data-end=\"3859\"\u003eHeating temperature range:\u003c\/p\u003e\n\u003cp data-start=\"3861\" data-end=\"3891\"\u003e\u003cstrong data-start=\"3861\" data-end=\"3891\"\u003eRoom temperature to 100 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3893\" data-end=\"3906\"\u003eHeater shape:\u003c\/p\u003e\n\u003cp data-start=\"3908\" data-end=\"3934\"\u003e\u003cstrong data-start=\"3908\" data-end=\"3934\"\u003eCircular heating block\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3936\" data-end=\"3952\"\u003eHeater diameter:\u003c\/p\u003e\n\u003cp data-start=\"3954\" data-end=\"3964\"\u003e\u003cstrong data-start=\"3954\" data-end=\"3964\"\u003eφ69 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3966\" data-end=\"3981\"\u003eHeating medium:\u003c\/p\u003e\n\u003cp data-start=\"3983\" data-end=\"4001\"\u003e\u003cstrong data-start=\"3983\" data-end=\"4001\"\u003eAluminum beads\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4003\" data-end=\"4006\"\u003e\n\u003ch1 data-section-id=\"17dvu82\" data-start=\"4008\" data-end=\"4035\"\u003eCompatible Container Size\u003c\/h1\u003e\n\u003cp data-start=\"4037\" data-end=\"4077\"\u003eInner diameter of compatible containers:\u003c\/p\u003e\n\u003cp data-start=\"4079\" data-end=\"4097\"\u003e\u003cstrong data-start=\"4079\" data-end=\"4097\"\u003eφ4 mm – φ32 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4099\" data-end=\"4116\"\u003eExamples include:\u003c\/p\u003e\n\u003cul data-start=\"4118\" data-end=\"4210\"\u003e\n\u003cli data-section-id=\"1d03kt4\" data-start=\"4118\" data-end=\"4137\"\u003e\n\u003cp data-start=\"4120\" data-end=\"4137\"\u003eHPLC sample vials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n902vg\" data-start=\"4138\" data-end=\"4155\"\u003e\n\u003cp data-start=\"4140\" data-end=\"4155\"\u003eEppendorf tubes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"134dzs\" data-start=\"4156\" data-end=\"4171\"\u003e\n\u003cp data-start=\"4158\" data-end=\"4171\"\u003eConical tubes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wold7\" data-start=\"4172\" data-end=\"4184\"\u003e\n\u003cp data-start=\"4174\" data-end=\"4184\"\u003eTest tubes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rjjtwn\" data-start=\"4185\" data-end=\"4210\"\u003e\n\u003cp data-start=\"4187\" data-end=\"4210\"\u003eAnalytical sample vials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4212\" data-end=\"4215\"\u003e\n\u003ch1 data-section-id=\"q7mkku\" data-start=\"4217\" data-end=\"4240\"\u003eOperating Environment\u003c\/h1\u003e\n\u003cp data-start=\"4242\" data-end=\"4264\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4266\" data-end=\"4283\"\u003e\u003cstrong data-start=\"4266\" data-end=\"4283\"\u003e10 °C – 40 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4285\" data-end=\"4288\"\u003e\n\u003ch1 data-section-id=\"q6znlx\" data-start=\"4290\" data-end=\"4302\"\u003eDimensions\u003c\/h1\u003e\n\u003cp data-start=\"4304\" data-end=\"4364\"\u003e\u003cstrong data-start=\"4304\" data-end=\"4333\"\u003e8 × 6 × 15 in (W × D × H)\u003c\/strong\u003e\u003cbr data-start=\"4333\" data-end=\"4336\"\u003e(excluding protruding parts)\u003c\/p\u003e\n\u003cp data-start=\"4366\" data-end=\"4395\"\u003eEquivalent metric dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4397\" data-end=\"4422\"\u003e\u003cstrong data-start=\"4397\" data-end=\"4422\"\u003eW205 × D150 × H379 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4424\" data-end=\"4427\"\u003e\n\u003ch1 data-section-id=\"en4152\" data-start=\"4429\" data-end=\"4437\"\u003eWeight\u003c\/h1\u003e\n\u003cp data-start=\"4439\" data-end=\"4459\"\u003e\u003cstrong data-start=\"4439\" data-end=\"4459\"\u003e4.6 lbs (2.1 kg)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4461\" data-end=\"4464\"\u003e\n\u003ch1 data-section-id=\"7ma9n\" data-start=\"4466\" data-end=\"4473\"\u003eColor\u003c\/h1\u003e\n\u003cp data-start=\"4475\" data-end=\"4487\"\u003eStone finish\u003c\/p\u003e\n\u003chr data-start=\"4489\" data-end=\"4492\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"4494\" data-end=\"4515\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"4517\" data-end=\"4702\"\u003e\n\u003cli data-section-id=\"1wvijeb\" data-start=\"4517\" data-end=\"4571\"\u003e\n\u003cp data-start=\"4519\" data-end=\"4571\"\u003eBioChromato ACR1 Acid-Resistant Smart Evaporator – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"x1c3pl\" data-start=\"4572\" data-end=\"4610\"\u003e\n\u003cp data-start=\"4574\" data-end=\"4610\"\u003eSpiral Plug Set (SP-P1 to SP-P5) – 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"flgvv4\" data-start=\"4611\" data-end=\"4644\"\u003e\n\u003cp data-start=\"4613\" data-end=\"4644\"\u003eAluminum Heating Beads – 1 pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7qu427\" data-start=\"4645\" data-end=\"4661\"\u003e\n\u003cp data-start=\"4647\" data-end=\"4661\"\u003ePower Cord – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o2k76w\" data-start=\"4662\" data-end=\"4677\"\u003e\n\u003cp data-start=\"4664\" data-end=\"4677\"\u003eHose Barb – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kmclxk\" data-start=\"4678\" data-end=\"4702\"\u003e\n\u003cp data-start=\"4680\" data-end=\"4702\"\u003eInstruction Manual – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4704\" data-end=\"4707\"\u003e\n\u003ch1 data-section-id=\"1fprf3z\" data-start=\"4709\" data-end=\"4752\"\u003eAdvantages of Smart Evaporator Technology\u003c\/h1\u003e\n\u003cp data-start=\"4754\" data-end=\"4831\"\u003eCompared with traditional evaporation methods, the Smart Evaporator provides:\u003c\/p\u003e\n\u003cul data-start=\"4833\" data-end=\"5045\"\u003e\n\u003cli data-section-id=\"5ypgtc\" data-start=\"4833\" data-end=\"4864\"\u003e\n\u003cp data-start=\"4835\" data-end=\"4864\"\u003eBump-free solvent evaporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1795fc8\" data-start=\"4865\" data-end=\"4894\"\u003e\n\u003cp data-start=\"4867\" data-end=\"4894\"\u003eFaster sample concentration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1383u3t\" data-start=\"4895\" data-end=\"4916\"\u003e\n\u003cp data-start=\"4897\" data-end=\"4916\"\u003eReduced sample loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o8eak9\" data-start=\"4917\" data-end=\"4952\"\u003e\n\u003cp data-start=\"4919\" data-end=\"4952\"\u003eDirect in-container concentration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dvwjx3\" data-start=\"4953\" data-end=\"4990\"\u003e\n\u003cp data-start=\"4955\" data-end=\"4990\"\u003eSimplified maintenance and cleaning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kvsw8t\" data-start=\"4991\" data-end=\"5045\"\u003e\n\u003cp data-start=\"4993\" data-end=\"5045\"\u003eSafe evaporation of high-boiling and acidic solvents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282531479874,"sku":null,"price":7126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/acr1.jpg?v=1773587071","url":"https:\/\/summitsupplydirect.com\/products\/across-international-acr1-110-biochromato-acr1-acid-resistant-bump-free-smart-evaporator","provider":"Summit Supply Direct","version":"1.0","type":"link"}