{"title":"Short Path Distillation Systems","description":"","products":[{"product_id":"across-international-clear10v-ai-10-liter-short-path-distillation-kit-with-valved-adapters","title":"Across International Clear10v Ai 10 Liter Short Path Distillation Kit with Valved Adapters","description":"\u003cp data-start=\"681\" data-end=\"1111\"\u003eThe \u003cstrong data-start=\"685\" data-end=\"745\"\u003eAcross International Clear10 Short Path Distillation Kit\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"768\" data-end=\"805\"\u003e10L molecular distillation system\u003c\/strong\u003e designed for precise separation and purification of heat-sensitive compounds. Built with \u003cstrong data-start=\"895\" data-end=\"963\"\u003eheavy-wall borosilicate glass and vacuum jacketed vapor pathways\u003c\/strong\u003e, this short path distillation system provides superior thermal stability and efficient vapor condensation for laboratory and research applications.\u003c\/p\u003e\n\u003cp data-start=\"1113\" data-end=\"1419\"\u003eThe newly redesigned \u003cstrong data-start=\"1134\" data-end=\"1174\"\u003e5L vacuum jacketed distillation head\u003c\/strong\u003e features a larger vapor channel and increased internal diameter, allowing for improved vapor flow and more efficient fractionation during distillation. This enhanced design helps prevent clogging while improving overall distillation efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1421\" data-end=\"1800\"\u003eConstructed from \u003cstrong data-start=\"1438\" data-end=\"1477\"\u003ehigh-quality borosilicate glass 3.3\u003c\/strong\u003e, the Clear10 system is engineered for durability and optimal chemical resistance. The system includes a \u003cstrong data-start=\"1582\" data-end=\"1721\"\u003e10L 3-neck boiling flask, vacuum jacketed distillation head, receiving flasks, thermometer adapters, and laboratory support accessories\u003c\/strong\u003e, making it a complete solution for advanced laboratory distillation processes.\u003c\/p\u003e\n\u003chr data-start=\"1802\" data-end=\"1805\"\u003e\n\u003ch1 data-start=\"1807\" data-end=\"1821\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-start=\"1823\" data-end=\"1871\"\u003eRedesigned Vacuum Jacketed Distillation Head\u003c\/h3\u003e\n\u003cul data-start=\"1872\" data-end=\"2079\"\u003e\n\u003cli data-start=\"1872\" data-end=\"1931\"\u003e\n\u003cp data-start=\"1874\" data-end=\"1931\"\u003eNewly engineered \u003cstrong data-start=\"1891\" data-end=\"1931\"\u003e5L vacuum jacketed distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1932\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1934\" data-end=\"1978\"\u003eLarger vapor channel for improved vapor flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1979\" data-end=\"2039\"\u003e\n\u003cp data-start=\"1981\" data-end=\"2039\"\u003eIncreased internal diameter for more efficient fractioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2040\" data-end=\"2079\"\u003e\n\u003cp data-start=\"2042\" data-end=\"2079\"\u003ePrevents clogging during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2081\" data-end=\"2123\"\u003eHigh Efficiency Molecular Distillation\u003c\/h3\u003e\n\u003cul data-start=\"2124\" data-end=\"2245\"\u003e\n\u003cli data-start=\"2124\" data-end=\"2173\"\u003e\n\u003cp data-start=\"2126\" data-end=\"2173\"\u003eVacuum jacketed vapor channel reduces heat loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2174\" data-end=\"2208\"\u003e\n\u003cp data-start=\"2176\" data-end=\"2208\"\u003eImproved condensation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2209\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2211\" data-end=\"2245\"\u003eIdeal for heat-sensitive compounds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2247\" data-end=\"2282\"\u003eHeavy Wall Laboratory Glassware\u003c\/h3\u003e\n\u003cul data-start=\"2283\" data-end=\"2396\"\u003e\n\u003cli data-start=\"2283\" data-end=\"2326\"\u003e\n\u003cp data-start=\"2285\" data-end=\"2326\"\u003eMade from \u003cstrong data-start=\"2295\" data-end=\"2326\"\u003ehigh borosilicate glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2327\" data-end=\"2396\"\u003e\n\u003cp data-start=\"2329\" data-end=\"2396\"\u003eThick glass construction improves durability and thermal resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2398\" data-end=\"2429\"\u003ePrecision Thermometer Ports\u003c\/h3\u003e\n\u003cul data-start=\"2430\" data-end=\"2580\"\u003e\n\u003cli data-start=\"2430\" data-end=\"2509\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2509\"\u003eThermometer ports located on both the \u003cstrong data-start=\"2470\" data-end=\"2509\"\u003eboiling flask and distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2510\" data-end=\"2580\"\u003e\n\u003cp data-start=\"2512\" data-end=\"2580\"\u003ePTFE thermometer adapters with Viton gaskets ensure airtight sealing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2582\" data-end=\"2613\"\u003eFlexible System Connections\u003c\/h3\u003e\n\u003cul data-start=\"2614\" data-end=\"2743\"\u003e\n\u003cli data-start=\"2614\" data-end=\"2652\"\u003e\n\u003cp data-start=\"2616\" data-end=\"2652\"\u003eGL-16 recirculating fluid connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2653\" data-end=\"2688\"\u003e\n\u003cp data-start=\"2655\" data-end=\"2688\"\u003e3\/8\" hose barb vacuum connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2689\" data-end=\"2743\"\u003e\n\u003cp data-start=\"2691\" data-end=\"2743\"\u003eCompatible with laboratory chillers and vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2745\" data-end=\"2778\"\u003eOptional Cold Trap Protection\u003c\/h3\u003e\n\u003cul data-start=\"2779\" data-end=\"2914\"\u003e\n\u003cli data-start=\"2779\" data-end=\"2858\"\u003e\n\u003cp data-start=\"2781\" data-end=\"2858\"\u003eOptional \u003cstrong data-start=\"2790\" data-end=\"2814\"\u003eT1 or T40 cold traps\u003c\/strong\u003e prevent vapor contamination of vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2859\" data-end=\"2914\"\u003e\n\u003cp data-start=\"2861\" data-end=\"2914\"\u003eProtects vacuum pump components from condensed vapors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2916\" data-end=\"2919\"\u003e\n\u003ch1 data-start=\"2921\" data-end=\"2941\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cul data-start=\"2943\" data-end=\"3142\"\u003e\n\u003cli data-start=\"2943\" data-end=\"2969\"\u003e\n\u003cp data-start=\"2945\" data-end=\"2969\"\u003eMolecular distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2970\" data-end=\"3010\"\u003e\n\u003cp data-start=\"2972\" data-end=\"3010\"\u003eCannabis extraction and distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3011\" data-end=\"3041\"\u003e\n\u003cp data-start=\"3013\" data-end=\"3041\"\u003eEssential oil purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3042\" data-end=\"3069\"\u003e\n\u003cp data-start=\"3044\" data-end=\"3069\"\u003ePharmaceutical research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3070\" data-end=\"3104\"\u003e\n\u003cp data-start=\"3072\" data-end=\"3104\"\u003eChemical compound purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3105\" data-end=\"3142\"\u003e\n\u003cp data-start=\"3107\" data-end=\"3142\"\u003eLaboratory distillation processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3144\" data-end=\"3147\"\u003e\n\u003ch1 data-start=\"3149\" data-end=\"3175\"\u003eGlassware Specifications\u003c\/h1\u003e\n\u003cul data-start=\"3177\" data-end=\"3348\"\u003e\n\u003cli data-start=\"3177\" data-end=\"3221\"\u003e\n\u003cp data-start=\"3179\" data-end=\"3221\"\u003eGlass Material: \u003cstrong data-start=\"3195\" data-end=\"3221\"\u003eBorosilicate Glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3222\" data-end=\"3265\"\u003e\n\u003cp data-start=\"3224\" data-end=\"3265\"\u003eDistillation Head: \u003cstrong data-start=\"3243\" data-end=\"3265\"\u003e5L Vacuum Jacketed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3266\" data-end=\"3305\"\u003e\n\u003cp data-start=\"3268\" data-end=\"3305\"\u003eBoiling Flask Capacity: \u003cstrong data-start=\"3292\" data-end=\"3305\"\u003e10 Liters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3306\" data-end=\"3348\"\u003e\n\u003cp data-start=\"3308\" data-end=\"3348\"\u003eHeavy wall laboratory glass construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3350\" data-end=\"3353\"\u003e\n\u003ch1 data-start=\"3355\" data-end=\"3368\"\u003eJoint Sizes\u003c\/h1\u003e\n\u003cul data-start=\"3370\" data-end=\"3569\"\u003e\n\u003cli data-start=\"3370\" data-end=\"3423\"\u003e\n\u003cp data-start=\"3372\" data-end=\"3423\"\u003eBoiling Flask to Distillation Head: \u003cstrong data-start=\"3408\" data-end=\"3423\"\u003e34\/45 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3424\" data-end=\"3473\"\u003e\n\u003cp data-start=\"3426\" data-end=\"3473\"\u003eBoiling Flask Thermometer Port: \u003cstrong data-start=\"3458\" data-end=\"3473\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3474\" data-end=\"3527\"\u003e\n\u003cp data-start=\"3476\" data-end=\"3527\"\u003eDistillation Head Thermometer Port: \u003cstrong data-start=\"3512\" data-end=\"3527\"\u003e14\/20 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3528\" data-end=\"3569\"\u003e\n\u003cp data-start=\"3530\" data-end=\"3569\"\u003eReceiving Flask Ports: \u003cstrong data-start=\"3553\" data-end=\"3569\"\u003e24\/40 joints\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3571\" data-end=\"3574\"\u003e\n\u003ch1 data-start=\"3576\" data-end=\"3596\"\u003eSystem Connections\u003c\/h1\u003e\n\u003cul data-start=\"3598\" data-end=\"3689\"\u003e\n\u003cli data-start=\"3598\" data-end=\"3649\"\u003e\n\u003cp data-start=\"3600\" data-end=\"3649\"\u003eRecirculating Fluid Connection: \u003cstrong data-start=\"3632\" data-end=\"3649\"\u003eGL-16 adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3650\" data-end=\"3689\"\u003e\n\u003cp data-start=\"3652\" data-end=\"3689\"\u003eVacuum Connection: \u003cstrong data-start=\"3671\" data-end=\"3689\"\u003e3\/8\" hose barb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3691\" data-end=\"3694\"\u003e\n\u003ch1 data-start=\"3696\" data-end=\"3713\"\u003eWhat's Included\u003c\/h1\u003e\n\u003ch3 data-start=\"3715\" data-end=\"3745\"\u003eDistillation Head Assembly\u003c\/h3\u003e\n\u003cul data-start=\"3747\" data-end=\"3897\"\u003e\n\u003cli data-start=\"3747\" data-end=\"3897\"\u003e\n\u003cp data-start=\"3749\" data-end=\"3796\"\u003e\u003cstrong data-start=\"3749\" data-end=\"3796\"\u003e1 × Ai 5L Vacuum Jacketed Distillation Head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3799\" data-end=\"3897\"\u003e\n\u003cli data-start=\"3799\" data-end=\"3839\"\u003e\n\u003cp data-start=\"3801\" data-end=\"3839\"\u003eMultiple Vigreux fractionation columns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3842\" data-end=\"3870\"\u003e\n\u003cp data-start=\"3844\" data-end=\"3870\"\u003eIntegrated cooling channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3873\" data-end=\"3897\"\u003e\n\u003cp data-start=\"3875\" data-end=\"3897\"\u003e14\/20 thermometer port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3899\" data-end=\"3902\"\u003e\n\u003ch3 data-start=\"3904\" data-end=\"3921\"\u003eBoiling Flask\u003c\/h3\u003e\n\u003cul data-start=\"3923\" data-end=\"4050\"\u003e\n\u003cli data-start=\"3923\" data-end=\"4050\"\u003e\n\u003cp data-start=\"3925\" data-end=\"3973\"\u003e\u003cstrong data-start=\"3925\" data-end=\"3973\"\u003e1 × 10L Heavy Wall 3-Neck Round Bottom Flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3976\" data-end=\"4050\"\u003e\n\u003cli data-start=\"3976\" data-end=\"4012\"\u003e\n\u003cp data-start=\"3978\" data-end=\"4012\"\u003eOne vertical \u003cstrong data-start=\"3991\" data-end=\"4012\"\u003e24\/40 center neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4015\" data-end=\"4050\"\u003e\n\u003cp data-start=\"4017\" data-end=\"4050\"\u003eTwo vertical \u003cstrong data-start=\"4030\" data-end=\"4050\"\u003e34\/45 side necks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4052\" data-end=\"4055\"\u003e\n\u003ch3 data-start=\"4057\" data-end=\"4077\"\u003eReceiving System\u003c\/h3\u003e\n\u003cul data-start=\"4079\" data-end=\"4149\"\u003e\n\u003cli data-start=\"4079\" data-end=\"4149\"\u003e\n\u003cp data-start=\"4081\" data-end=\"4149\"\u003e\u003cstrong data-start=\"4081\" data-end=\"4149\"\u003e2 × 2000mL Heavy Wall Pear-Shaped Receiving Flasks (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4151\" data-end=\"4154\"\u003e\n\u003ch3 data-start=\"4156\" data-end=\"4177\"\u003eGlass Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4179\" data-end=\"4375\"\u003e\n\u003cli data-start=\"4179\" data-end=\"4225\"\u003e\n\u003cp data-start=\"4181\" data-end=\"4225\"\u003e\u003cstrong data-start=\"4181\" data-end=\"4225\"\u003e1 × 24\/40 Joint Round Top Feeding Funnel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4226\" data-end=\"4266\"\u003e\n\u003cp data-start=\"4228\" data-end=\"4266\"\u003e\u003cstrong data-start=\"4228\" data-end=\"4266\"\u003e2 × 24\/40 Pennyhead Glass Stoppers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4267\" data-end=\"4331\"\u003e\n\u003cp data-start=\"4269\" data-end=\"4331\"\u003e\u003cstrong data-start=\"4269\" data-end=\"4331\"\u003e2 × Valved Adapters with Two 24\/40 Ports and One GL16 Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4332\" data-end=\"4375\"\u003e\n\u003cp data-start=\"4334\" data-end=\"4375\"\u003e\u003cstrong data-start=\"4334\" data-end=\"4375\"\u003e3 × Glass 3\/8\" Hose Barb Tee Adapters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4377\" data-end=\"4380\"\u003e\n\u003ch3 data-start=\"4382\" data-end=\"4406\"\u003eThermometer Adapters\u003c\/h3\u003e\n\u003cul data-start=\"4408\" data-end=\"4474\"\u003e\n\u003cli data-start=\"4408\" data-end=\"4474\"\u003e\n\u003cp data-start=\"4410\" data-end=\"4474\"\u003e\u003cstrong data-start=\"4410\" data-end=\"4474\"\u003e3 × PTFE 24\/40 Thermometer Inlet Adapters with Viton Gaskets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4476\" data-end=\"4479\"\u003e\n\u003ch3 data-start=\"4481\" data-end=\"4504\"\u003eLaboratory Hardware\u003c\/h3\u003e\n\u003cul data-start=\"4506\" data-end=\"4626\"\u003e\n\u003cli data-start=\"4506\" data-end=\"4548\"\u003e\n\u003cp data-start=\"4508\" data-end=\"4548\"\u003e\u003cstrong data-start=\"4508\" data-end=\"4548\"\u003e2 × Stainless Steel 34\/45 Keck Clips\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4549\" data-end=\"4591\"\u003e\n\u003cp data-start=\"4551\" data-end=\"4591\"\u003e\u003cstrong data-start=\"4551\" data-end=\"4591\"\u003e2 × Stainless Steel 24\/40 Keck Clips\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4592\" data-end=\"4626\"\u003e\n\u003cp data-start=\"4594\" data-end=\"4626\"\u003e\u003cstrong data-start=\"4594\" data-end=\"4626\"\u003e2 × Plastic 24\/40 Keck Clips\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4628\" data-end=\"4631\"\u003e\n\u003ch3 data-start=\"4633\" data-end=\"4665\"\u003eLaboratory Support Equipment\u003c\/h3\u003e\n\u003cul data-start=\"4667\" data-end=\"4825\"\u003e\n\u003cli data-start=\"4667\" data-end=\"4725\"\u003e\n\u003cp data-start=\"4669\" data-end=\"4725\"\u003e\u003cstrong data-start=\"4669\" data-end=\"4725\"\u003e2 × Cork Ring Stands for 1L or 2L Pear-Shaped Flasks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4726\" data-end=\"4825\"\u003e\n\u003cp data-start=\"4728\" data-end=\"4769\"\u003e\u003cstrong data-start=\"4728\" data-end=\"4769\"\u003e2 × 6\" × 6\" Stainless Steel Lab Jacks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4772\" data-end=\"4825\"\u003e\n\u003cli data-start=\"4772\" data-end=\"4796\"\u003e\n\u003cp data-start=\"4774\" data-end=\"4796\"\u003eMinimum Height: \u003cstrong data-start=\"4790\" data-end=\"4796\"\u003e3\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4799\" data-end=\"4825\"\u003e\n\u003cp data-start=\"4801\" data-end=\"4825\"\u003eMaximum Height: \u003cstrong data-start=\"4817\" data-end=\"4825\"\u003e9.5\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4827\" data-end=\"4830\"\u003e\n\u003ch3 data-start=\"4832\" data-end=\"4861\"\u003eMeasurement \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4863\" data-end=\"4962\"\u003e\n\u003cli data-start=\"4863\" data-end=\"4912\"\u003e\n\u003cp data-start=\"4865\" data-end=\"4912\"\u003e\u003cstrong data-start=\"4865\" data-end=\"4912\"\u003e2 × Traceable Kangaroo Digital Thermometers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4913\" data-end=\"4962\"\u003e\n\u003cp data-start=\"4915\" data-end=\"4962\"\u003e\u003cstrong data-start=\"4915\" data-end=\"4962\"\u003e1 × Dow Corning High Vacuum Grease (5.3 oz)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4964\" data-end=\"4967\"\u003e\n\u003ch1 data-start=\"4969\" data-end=\"4987\"\u003eGlassware Notice\u003c\/h1\u003e\n\u003cp data-start=\"4989\" data-end=\"5121\"\u003eGlassware does \u003cstrong data-start=\"5004\" data-end=\"5043\"\u003enot include a manufacturer warranty\u003c\/strong\u003e.\u003cbr data-start=\"5044\" data-end=\"5047\"\u003eMinor cosmetic blemishes may be present but will not affect functionality.\u003c\/p\u003e\n\u003cp data-start=\"5123\" data-end=\"5226\"\u003eAll glassware is \u003cstrong data-start=\"5140\" data-end=\"5169\"\u003einspected before shipping\u003c\/strong\u003e to ensure no defective components are sent to customers.\u003c\/p\u003e\n\u003chr data-start=\"5228\" data-end=\"5231\"\u003e\n\u003ch1 data-start=\"5233\" data-end=\"5274\"\u003eRecommended Equipment (Sold Separately)\u003c\/h1\u003e\n\u003cp data-start=\"5276\" data-end=\"5330\"\u003eFor optimal operation, this system typically requires:\u003c\/p\u003e\n\u003cul data-start=\"5332\" data-end=\"5414\"\u003e\n\u003cli data-start=\"5332\" data-end=\"5349\"\u003e\n\u003cp data-start=\"5334\" data-end=\"5349\"\u003e\u003cstrong data-start=\"5334\" data-end=\"5349\"\u003eVacuum Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5350\" data-end=\"5377\"\u003e\n\u003cp data-start=\"5352\" data-end=\"5377\"\u003e\u003cstrong data-start=\"5352\" data-end=\"5377\"\u003eRecirculating Chiller\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5378\" data-end=\"5398\"\u003e\n\u003cp data-start=\"5380\" data-end=\"5398\"\u003e\u003cstrong data-start=\"5380\" data-end=\"5398\"\u003eHeating Mantle\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5399\" data-end=\"5414\"\u003e\n\u003cp data-start=\"5401\" data-end=\"5414\"\u003e\u003cstrong data-start=\"5401\" data-end=\"5414\"\u003eCold Trap\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52127694553410,"sku":null,"price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/clear10-vcow_clear10v_1_6e9f9c0b-dfa9-46ea-9264-c942cd2055b5.jpg?v=1773973905"},{"product_id":"across-international-clear2-ai-2l-short-path-distillation-kit-with-multiple-receiving-flasks","title":"Across International Clear2 Ai 2L Short Path Distillation Kit with Multiple Receiving Flasks","description":"\u003cp data-start=\"542\" data-end=\"960\"\u003eThe \u003cstrong data-start=\"546\" data-end=\"605\"\u003eAcross International Clear2 Short Path Distillation Kit\u003c\/strong\u003e is a compact \u003cstrong data-start=\"619\" data-end=\"655\"\u003e2L molecular distillation system\u003c\/strong\u003e designed for efficient purification and separation of heat-sensitive compounds in laboratory and research environments. Built with \u003cstrong data-start=\"787\" data-end=\"855\"\u003eheavy-wall borosilicate glass and vacuum-jacketed vapor pathways\u003c\/strong\u003e, this short path distillation system minimizes heat loss while maximizing vapor condensation efficiency.\u003c\/p\u003e\n\u003cp data-start=\"962\" data-end=\"1195\"\u003eThe newly redesigned \u003cstrong data-start=\"983\" data-end=\"1020\"\u003evacuum-jacketed distillation head\u003c\/strong\u003e features a larger vapor channel and increased internal diameter, allowing for improved vapor flow and more efficient fractionation while preventing clogging during operation.\u003c\/p\u003e\n\u003cp data-start=\"1197\" data-end=\"1362\"\u003eConstructed from \u003cstrong data-start=\"1214\" data-end=\"1253\"\u003ehigh-quality borosilicate glass 3.3\u003c\/strong\u003e, the Clear2 system is engineered for durability, chemical resistance, and consistent laboratory performance.\u003c\/p\u003e\n\u003cp data-start=\"1364\" data-end=\"1624\"\u003eThis kit includes the \u003cstrong data-start=\"1386\" data-end=\"1521\"\u003edistillation head, boiling flask, receiving flasks, distribution adapters, thermometer adapters, and laboratory support accessories\u003c\/strong\u003e, making it an excellent solution for \u003cstrong data-start=\"1559\" data-end=\"1623\"\u003esmall-scale molecular distillation and research applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1626\" data-end=\"1629\"\u003e\n\u003ch1 data-start=\"1631\" data-end=\"1645\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-start=\"1647\" data-end=\"1695\"\u003eRedesigned Vacuum Jacketed Distillation Head\u003c\/h3\u003e\n\u003cul data-start=\"1696\" data-end=\"1900\"\u003e\n\u003cli data-start=\"1696\" data-end=\"1738\"\u003e\n\u003cp data-start=\"1698\" data-end=\"1738\"\u003eLarger vapor channel improves vapor flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1802\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1802\"\u003eIncreased internal diameter enhances fractionation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1803\" data-end=\"1842\"\u003e\n\u003cp data-start=\"1805\" data-end=\"1842\"\u003ePrevents clogging during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1843\" data-end=\"1900\"\u003e\n\u003cp data-start=\"1845\" data-end=\"1900\"\u003eReduces heat loss through vacuum-jacketed vapor pathway\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1902\" data-end=\"1944\"\u003eHigh Efficiency Molecular Distillation\u003c\/h3\u003e\n\u003cul data-start=\"1945\" data-end=\"2060\"\u003e\n\u003cli data-start=\"1945\" data-end=\"2004\"\u003e\n\u003cp data-start=\"1947\" data-end=\"2004\"\u003eVacuum jacketed vapor channel maintains thermal stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2005\" data-end=\"2060\"\u003e\n\u003cp data-start=\"2007\" data-end=\"2060\"\u003eOptimized vapor condensation for efficient separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2062\" data-end=\"2097\"\u003eHeavy Wall Laboratory Glassware\u003c\/h3\u003e\n\u003cul data-start=\"2098\" data-end=\"2205\"\u003e\n\u003cli data-start=\"2098\" data-end=\"2136\"\u003e\n\u003cp data-start=\"2100\" data-end=\"2136\"\u003eMade from \u003cstrong data-start=\"2110\" data-end=\"2136\"\u003eborosilicate glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2137\" data-end=\"2205\"\u003e\n\u003cp data-start=\"2139\" data-end=\"2205\"\u003eThick wall construction improves durability and thermal resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2207\" data-end=\"2243\"\u003ePrecision Temperature Monitoring\u003c\/h3\u003e\n\u003cul data-start=\"2244\" data-end=\"2395\"\u003e\n\u003cli data-start=\"2244\" data-end=\"2323\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2323\"\u003eThermometer ports located on both the \u003cstrong data-start=\"2284\" data-end=\"2323\"\u003eboiling flask and distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2395\"\u003e\n\u003cp data-start=\"2326\" data-end=\"2395\"\u003ePTFE thermometer adapters with \u003cstrong data-start=\"2357\" data-end=\"2395\"\u003eViton gaskets for airtight sealing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2397\" data-end=\"2428\"\u003eFlexible System Connections\u003c\/h3\u003e\n\u003cul data-start=\"2429\" data-end=\"2568\"\u003e\n\u003cli data-start=\"2429\" data-end=\"2477\"\u003e\n\u003cp data-start=\"2431\" data-end=\"2477\"\u003eGL-16 adapters for recirculating cooling fluid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2478\" data-end=\"2513\"\u003e\n\u003cp data-start=\"2480\" data-end=\"2513\"\u003e3\/8\" hose barb vacuum connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2514\" data-end=\"2568\"\u003e\n\u003cp data-start=\"2516\" data-end=\"2568\"\u003eCompatible with laboratory chillers and vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2570\" data-end=\"2573\"\u003e\n\u003ch1 data-start=\"2575\" data-end=\"2595\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cul data-start=\"2597\" data-end=\"2796\"\u003e\n\u003cli data-start=\"2597\" data-end=\"2623\"\u003e\n\u003cp data-start=\"2599\" data-end=\"2623\"\u003eMolecular distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2624\" data-end=\"2656\"\u003e\n\u003cp data-start=\"2626\" data-end=\"2656\"\u003eCannabis extraction research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2657\" data-end=\"2687\"\u003e\n\u003cp data-start=\"2659\" data-end=\"2687\"\u003eEssential oil purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2688\" data-end=\"2724\"\u003e\n\u003cp data-start=\"2690\" data-end=\"2724\"\u003eLaboratory compound purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2725\" data-end=\"2759\"\u003e\n\u003cp data-start=\"2727\" data-end=\"2759\"\u003eChemical distillation research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2760\" data-end=\"2796\"\u003e\n\u003cp data-start=\"2762\" data-end=\"2796\"\u003ePilot scale distillation testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2798\" data-end=\"2801\"\u003e\n\u003ch1 data-start=\"2803\" data-end=\"2829\"\u003eGlassware Specifications\u003c\/h1\u003e\n\u003cul data-start=\"2831\" data-end=\"2960\"\u003e\n\u003cli data-start=\"2831\" data-end=\"2876\"\u003e\n\u003cp data-start=\"2833\" data-end=\"2876\"\u003eGlass Type: \u003cstrong data-start=\"2845\" data-end=\"2876\"\u003eHigh Borosilicate Glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2877\" data-end=\"2917\"\u003e\n\u003cp data-start=\"2879\" data-end=\"2917\"\u003eDistillation Head: \u003cstrong data-start=\"2898\" data-end=\"2917\"\u003eVacuum Jacketed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2918\" data-end=\"2960\"\u003e\n\u003cp data-start=\"2920\" data-end=\"2960\"\u003eHeavy wall laboratory glass construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2962\" data-end=\"2965\"\u003e\n\u003ch1 data-start=\"2967\" data-end=\"2980\"\u003eJoint Sizes\u003c\/h1\u003e\n\u003cul data-start=\"2982\" data-end=\"3187\"\u003e\n\u003cli data-start=\"2982\" data-end=\"3035\"\u003e\n\u003cp data-start=\"2984\" data-end=\"3035\"\u003eBoiling Flask to Distillation Head: \u003cstrong data-start=\"3020\" data-end=\"3035\"\u003e34\/45 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3036\" data-end=\"3089\"\u003e\n\u003cp data-start=\"3038\" data-end=\"3089\"\u003eDistillation Head Thermometer Port: \u003cstrong data-start=\"3074\" data-end=\"3089\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3090\" data-end=\"3139\"\u003e\n\u003cp data-start=\"3092\" data-end=\"3139\"\u003eBoiling Flask Thermometer Port: \u003cstrong data-start=\"3124\" data-end=\"3139\"\u003e24\/20 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3140\" data-end=\"3187\"\u003e\n\u003cp data-start=\"3142\" data-end=\"3187\"\u003eReceiving Flask Connections: \u003cstrong data-start=\"3171\" data-end=\"3187\"\u003e24\/40 joints\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3189\" data-end=\"3192\"\u003e\n\u003ch1 data-start=\"3194\" data-end=\"3214\"\u003eSystem Connections\u003c\/h1\u003e\n\u003cul data-start=\"3216\" data-end=\"3307\"\u003e\n\u003cli data-start=\"3216\" data-end=\"3267\"\u003e\n\u003cp data-start=\"3218\" data-end=\"3267\"\u003eRecirculating Fluid Connection: \u003cstrong data-start=\"3250\" data-end=\"3267\"\u003eGL-16 adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3268\" data-end=\"3307\"\u003e\n\u003cp data-start=\"3270\" data-end=\"3307\"\u003eVacuum Connection: \u003cstrong data-start=\"3289\" data-end=\"3307\"\u003e3\/8\" hose barb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3309\" data-end=\"3312\"\u003e\n\u003ch1 data-start=\"3314\" data-end=\"3336\"\u003eShipping Information\u003c\/h1\u003e\n\u003cul data-start=\"3338\" data-end=\"3413\"\u003e\n\u003cli data-start=\"3338\" data-end=\"3383\"\u003e\n\u003cp data-start=\"3340\" data-end=\"3383\"\u003eShipping Dimensions: \u003cstrong data-start=\"3361\" data-end=\"3383\"\u003e27 × 22 × 9 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3384\" data-end=\"3413\"\u003e\n\u003cp data-start=\"3386\" data-end=\"3413\"\u003eShipping Weight: \u003cstrong data-start=\"3403\" data-end=\"3413\"\u003e14 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3415\" data-end=\"3418\"\u003e\n\u003ch1 data-start=\"3420\" data-end=\"3437\"\u003eWhat's Included\u003c\/h1\u003e\n\u003ch3 data-start=\"3439\" data-end=\"3469\"\u003eDistillation Head Assembly\u003c\/h3\u003e\n\u003cul data-start=\"3471\" data-end=\"3615\"\u003e\n\u003cli data-start=\"3471\" data-end=\"3615\"\u003e\n\u003cp data-start=\"3473\" data-end=\"3525\"\u003e\u003cstrong data-start=\"3473\" data-end=\"3525\"\u003e1 × Heavy Wall Vacuum Jacketed Distillation Head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3528\" data-end=\"3615\"\u003e\n\u003cli data-start=\"3528\" data-end=\"3568\"\u003e\n\u003cp data-start=\"3530\" data-end=\"3568\"\u003eMultiple Vigreux fractionation columns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3571\" data-end=\"3588\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3588\"\u003eCooling channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3591\" data-end=\"3615\"\u003e\n\u003cp data-start=\"3593\" data-end=\"3615\"\u003eTemperature probe port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3617\" data-end=\"3620\"\u003e\n\u003ch3 data-start=\"3622\" data-end=\"3639\"\u003eBoiling Flask\u003c\/h3\u003e\n\u003cul data-start=\"3641\" data-end=\"3761\"\u003e\n\u003cli data-start=\"3641\" data-end=\"3761\"\u003e\n\u003cp data-start=\"3643\" data-end=\"3687\"\u003e\u003cstrong data-start=\"3643\" data-end=\"3687\"\u003e1 × Heavy Wall 2-Neck Round Bottom Flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3690\" data-end=\"3761\"\u003e\n\u003cli data-start=\"3690\" data-end=\"3726\"\u003e\n\u003cp data-start=\"3692\" data-end=\"3726\"\u003eOne \u003cstrong data-start=\"3696\" data-end=\"3726\"\u003e34\/45 vertical center neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3729\" data-end=\"3761\"\u003e\n\u003cp data-start=\"3731\" data-end=\"3761\"\u003eOne \u003cstrong data-start=\"3735\" data-end=\"3761\"\u003e24\/40 angled side neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3763\" data-end=\"3766\"\u003e\n\u003ch3 data-start=\"3768\" data-end=\"3792\"\u003eThermometer Adapters\u003c\/h3\u003e\n\u003cul data-start=\"3794\" data-end=\"3860\"\u003e\n\u003cli data-start=\"3794\" data-end=\"3860\"\u003e\n\u003cp data-start=\"3796\" data-end=\"3860\"\u003e\u003cstrong data-start=\"3796\" data-end=\"3860\"\u003e2 × PTFE 24\/40 Thermometer Inlet Adapters with Viton Gaskets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3862\" data-end=\"3865\"\u003e\n\u003ch3 data-start=\"3867\" data-end=\"3887\"\u003eReceiving System\u003c\/h3\u003e\n\u003cul data-start=\"3889\" data-end=\"4003\"\u003e\n\u003cli data-start=\"3889\" data-end=\"3946\"\u003e\n\u003cp data-start=\"3891\" data-end=\"3946\"\u003e\u003cstrong data-start=\"3891\" data-end=\"3946\"\u003e2 × 500mL Heavy Wall Receiving Flasks (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3947\" data-end=\"4003\"\u003e\n\u003cp data-start=\"3949\" data-end=\"4003\"\u003e\u003cstrong data-start=\"3949\" data-end=\"4003\"\u003e1 × 250mL Heavy Wall Receiving Flask (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4005\" data-end=\"4008\"\u003e\n\u003ch3 data-start=\"4010\" data-end=\"4035\"\u003eDistribution Adapters\u003c\/h3\u003e\n\u003cul data-start=\"4037\" data-end=\"4193\"\u003e\n\u003cli data-start=\"4037\" data-end=\"4113\"\u003e\n\u003cp data-start=\"4039\" data-end=\"4113\"\u003e\u003cstrong data-start=\"4039\" data-end=\"4113\"\u003e1 × 250mL Distribution Adapter with One Receiving Port and Vacuum Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4114\" data-end=\"4193\"\u003e\n\u003cp data-start=\"4116\" data-end=\"4193\"\u003e\u003cstrong data-start=\"4116\" data-end=\"4193\"\u003e1 × 250mL Distribution Adapter with Three Receiving Ports and Vacuum Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4195\" data-end=\"4198\"\u003e\n\u003ch3 data-start=\"4200\" data-end=\"4221\"\u003eGlass Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4223\" data-end=\"4352\"\u003e\n\u003cli data-start=\"4223\" data-end=\"4262\"\u003e\n\u003cp data-start=\"4225\" data-end=\"4262\"\u003e\u003cstrong data-start=\"4225\" data-end=\"4262\"\u003e1 × 24\/40 PennyHead Glass Stopper\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4263\" data-end=\"4309\"\u003e\n\u003cp data-start=\"4265\" data-end=\"4309\"\u003e\u003cstrong data-start=\"4265\" data-end=\"4309\"\u003e1 × 24\/40 Round Top Glass Feeding Funnel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4310\" data-end=\"4352\"\u003e\n\u003cp data-start=\"4312\" data-end=\"4352\"\u003e\u003cstrong data-start=\"4312\" data-end=\"4352\"\u003e1 × Glass 3\/8\" Hose Barb Tee Adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4354\" data-end=\"4357\"\u003e\n\u003ch3 data-start=\"4359\" data-end=\"4382\"\u003eLaboratory Hardware\u003c\/h3\u003e\n\u003cul data-start=\"4384\" data-end=\"4475\"\u003e\n\u003cli data-start=\"4384\" data-end=\"4438\"\u003e\n\u003cp data-start=\"4386\" data-end=\"4438\"\u003e\u003cstrong data-start=\"4386\" data-end=\"4438\"\u003e2 × Stainless Steel Keck Clips (24\/40 and 34\/45)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4439\" data-end=\"4475\"\u003e\n\u003cp data-start=\"4441\" data-end=\"4475\"\u003e\u003cstrong data-start=\"4441\" data-end=\"4475\"\u003e3 × Plastic Keck Clips (24\/40)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4477\" data-end=\"4480\"\u003e\n\u003ch3 data-start=\"4482\" data-end=\"4514\"\u003eLaboratory Support Equipment\u003c\/h3\u003e\n\u003cul data-start=\"4516\" data-end=\"4682\"\u003e\n\u003cli data-start=\"4516\" data-end=\"4591\"\u003e\n\u003cp data-start=\"4518\" data-end=\"4542\"\u003e\u003cstrong data-start=\"4518\" data-end=\"4542\"\u003e2 × Cork Ring Stands\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4545\" data-end=\"4591\"\u003e\n\u003cli data-start=\"4545\" data-end=\"4565\"\u003e\n\u003cp data-start=\"4547\" data-end=\"4565\"\u003e1 for \u003cstrong data-start=\"4553\" data-end=\"4565\"\u003e2L flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4568\" data-end=\"4591\"\u003e\n\u003cp data-start=\"4570\" data-end=\"4591\"\u003e1 for \u003cstrong data-start=\"4576\" data-end=\"4591\"\u003e500mL flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4593\" data-end=\"4682\"\u003e\n\u003cp data-start=\"4595\" data-end=\"4627\"\u003e\u003cstrong data-start=\"4595\" data-end=\"4627\"\u003e1 × Stainless Steel Lab Jack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4630\" data-end=\"4682\"\u003e\n\u003cli data-start=\"4630\" data-end=\"4649\"\u003e\n\u003cp data-start=\"4632\" data-end=\"4649\"\u003eSize: \u003cstrong data-start=\"4638\" data-end=\"4649\"\u003e4\" × 4\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4652\" data-end=\"4682\"\u003e\n\u003cp data-start=\"4654\" data-end=\"4682\"\u003eHeight Range: \u003cstrong data-start=\"4668\" data-end=\"4682\"\u003e1.75\" – 6\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4684\" data-end=\"4687\"\u003e\n\u003ch3 data-start=\"4689\" data-end=\"4718\"\u003eMeasurement \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4720\" data-end=\"4818\"\u003e\n\u003cli data-start=\"4720\" data-end=\"4768\"\u003e\n\u003cp data-start=\"4722\" data-end=\"4768\"\u003e\u003cstrong data-start=\"4722\" data-end=\"4768\"\u003e1 × Traceable Kangaroo Digital Thermometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4769\" data-end=\"4818\"\u003e\n\u003cp data-start=\"4771\" data-end=\"4818\"\u003e\u003cstrong data-start=\"4771\" data-end=\"4818\"\u003e1 × Dow Corning High Vacuum Grease (5.3 oz)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4820\" data-end=\"4823\"\u003e\n\u003ch1 data-start=\"4825\" data-end=\"4843\"\u003eGlassware Notice\u003c\/h1\u003e\n\u003cp data-start=\"4845\" data-end=\"4900\"\u003eGlassware \u003cstrong data-start=\"4855\" data-end=\"4899\"\u003edoes not include a manufacturer warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4902\" data-end=\"5097\"\u003eMinor cosmetic blemishes may be present but will \u003cstrong data-start=\"4951\" data-end=\"4994\"\u003enot affect performance or functionality\u003c\/strong\u003e. All glassware is inspected prior to shipping to ensure no defective components are sent to customers.\u003c\/p\u003e\n\u003chr data-start=\"5099\" data-end=\"5102\"\u003e\n\u003ch1 data-start=\"5104\" data-end=\"5145\"\u003eRecommended Equipment (Sold Separately)\u003c\/h1\u003e\n\u003cp data-start=\"5147\" data-end=\"5231\"\u003eFor optimal performance, the following equipment is typically used with this system:\u003c\/p\u003e\n\u003cul data-start=\"5233\" data-end=\"5307\"\u003e\n\u003cli data-start=\"5233\" data-end=\"5248\"\u003e\n\u003cp data-start=\"5235\" data-end=\"5248\"\u003eVacuum pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5249\" data-end=\"5274\"\u003e\n\u003cp data-start=\"5251\" data-end=\"5274\"\u003eRecirculating chiller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5275\" data-end=\"5293\"\u003e\n\u003cp data-start=\"5277\" data-end=\"5293\"\u003eHeating mantle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5294\" data-end=\"5307\"\u003e\n\u003cp data-start=\"5296\" data-end=\"5307\"\u003eCold trap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52127698813250,"sku":null,"price":790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/clear2_newstdhead_cow3_clear2_1.jpg?v=1772745323"},{"product_id":"across-international-clear2v-ai-2-liter-short-path-distillation-kit-with-valved-adapter","title":"Across International Clear2v Ai 2 Liter Short Path Distillation Kit with Valved Adapter","description":"\u003cp data-start=\"557\" data-end=\"917\"\u003eThe \u003cstrong data-start=\"561\" data-end=\"620\"\u003eAcross International Clear2 Short Path Distillation Kit\u003c\/strong\u003e is a compact laboratory distillation system designed for efficient purification and separation of heat-sensitive compounds. Built with \u003cstrong data-start=\"756\" data-end=\"825\"\u003eheavy-wall borosilicate glass and a vacuum-jacketed vapor pathway\u003c\/strong\u003e, this short path system minimizes heat loss while maximizing vapor condensation efficiency.\u003c\/p\u003e\n\u003cp data-start=\"919\" data-end=\"1136\"\u003eThe redesigned \u003cstrong data-start=\"934\" data-end=\"971\"\u003evacuum-jacketed distillation head\u003c\/strong\u003e features a larger vapor channel and increased internal diameter, allowing for improved vapor flow, more efficient fractionation, and zero clogging during operation.\u003c\/p\u003e\n\u003cp data-start=\"1138\" data-end=\"1402\"\u003eConstructed from \u003cstrong data-start=\"1155\" data-end=\"1194\"\u003ehigh-quality borosilicate glass 3.3\u003c\/strong\u003e, the Clear2 kit offers excellent thermal resistance and durability, making it ideal for \u003cstrong data-start=\"1283\" data-end=\"1401\"\u003elaboratory distillation, cannabis extraction research, chemical purification, and molecular distillation processes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1404\" data-end=\"1407\"\u003e\n\u003ch1 data-start=\"1409\" data-end=\"1423\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-start=\"1425\" data-end=\"1473\"\u003eRedesigned Vacuum Jacketed Distillation Head\u003c\/h3\u003e\n\u003cul data-start=\"1474\" data-end=\"1654\"\u003e\n\u003cli data-start=\"1474\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1476\" data-end=\"1516\"\u003eLarger vapor channel improves vapor flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1579\"\u003eIncreased internal diameter for more efficient fractionation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1580\" data-end=\"1618\"\u003e\n\u003cp data-start=\"1582\" data-end=\"1618\"\u003eReduces clogging during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1619\" data-end=\"1654\"\u003e\n\u003cp data-start=\"1621\" data-end=\"1654\"\u003eVacuum jacket minimizes heat loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1656\" data-end=\"1693\"\u003eHigh-Quality Laboratory Glassware\u003c\/h3\u003e\n\u003cul data-start=\"1694\" data-end=\"1817\"\u003e\n\u003cli data-start=\"1694\" data-end=\"1732\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1732\"\u003eMade from \u003cstrong data-start=\"1706\" data-end=\"1732\"\u003eborosilicate glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1733\" data-end=\"1778\"\u003e\n\u003cp data-start=\"1735\" data-end=\"1778\"\u003eHeavy wall construction improves durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1779\" data-end=\"1817\"\u003e\n\u003cp data-start=\"1781\" data-end=\"1817\"\u003eDesigned for repeated laboratory use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1819\" data-end=\"1855\"\u003eEfficient Molecular Distillation\u003c\/h3\u003e\n\u003cul data-start=\"1856\" data-end=\"1974\"\u003e\n\u003cli data-start=\"1856\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1920\"\u003eVacuum jacketed vapor channel improves condensation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1921\" data-end=\"1974\"\u003e\n\u003cp data-start=\"1923\" data-end=\"1974\"\u003eMaintains temperature stability during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1976\" data-end=\"2012\"\u003ePrecision Temperature Monitoring\u003c\/h3\u003e\n\u003cul data-start=\"2013\" data-end=\"2167\"\u003e\n\u003cli data-start=\"2013\" data-end=\"2092\"\u003e\n\u003cp data-start=\"2015\" data-end=\"2092\"\u003eThermometer ports located on both the \u003cstrong data-start=\"2053\" data-end=\"2092\"\u003eboiling flask and distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2093\" data-end=\"2167\"\u003e\n\u003cp data-start=\"2095\" data-end=\"2167\"\u003ePTFE thermometer adapters with \u003cstrong data-start=\"2126\" data-end=\"2143\"\u003eViton gaskets\u003c\/strong\u003e ensure airtight sealing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2169\" data-end=\"2200\"\u003eFlexible System Connections\u003c\/h3\u003e\n\u003cul data-start=\"2201\" data-end=\"2364\"\u003e\n\u003cli data-start=\"2201\" data-end=\"2257\"\u003e\n\u003cp data-start=\"2203\" data-end=\"2257\"\u003e\u003cstrong data-start=\"2203\" data-end=\"2221\"\u003eGL-16 adapters\u003c\/strong\u003e for recirculating fluid connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2258\" data-end=\"2309\"\u003e\n\u003cp data-start=\"2260\" data-end=\"2309\"\u003e\u003cstrong data-start=\"2260\" data-end=\"2290\"\u003e3\/8\" hose barb connections\u003c\/strong\u003e for vacuum systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2310\" data-end=\"2364\"\u003e\n\u003cp data-start=\"2312\" data-end=\"2364\"\u003eCompatible with laboratory chillers and vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2366\" data-end=\"2369\"\u003e\n\u003ch1 data-start=\"2371\" data-end=\"2391\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cul data-start=\"2393\" data-end=\"2592\"\u003e\n\u003cli data-start=\"2393\" data-end=\"2419\"\u003e\n\u003cp data-start=\"2395\" data-end=\"2419\"\u003eMolecular distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2420\" data-end=\"2452\"\u003e\n\u003cp data-start=\"2422\" data-end=\"2452\"\u003eCannabis extraction research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2453\" data-end=\"2483\"\u003e\n\u003cp data-start=\"2455\" data-end=\"2483\"\u003eEssential oil purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2484\" data-end=\"2518\"\u003e\n\u003cp data-start=\"2486\" data-end=\"2518\"\u003eLaboratory compound separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2519\" data-end=\"2554\"\u003e\n\u003cp data-start=\"2521\" data-end=\"2554\"\u003eChemical distillation processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2555\" data-end=\"2592\"\u003e\n\u003cp data-start=\"2557\" data-end=\"2592\"\u003eSmall-scale distillation research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2594\" data-end=\"2597\"\u003e\n\u003ch1 data-start=\"2599\" data-end=\"2625\"\u003eGlassware Specifications\u003c\/h1\u003e\n\u003cul data-start=\"2627\" data-end=\"2755\"\u003e\n\u003cli data-start=\"2627\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2629\" data-end=\"2671\"\u003eGlass Material: \u003cstrong data-start=\"2645\" data-end=\"2671\"\u003eBorosilicate Glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2712\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2712\"\u003eDistillation Head: \u003cstrong data-start=\"2693\" data-end=\"2712\"\u003eVacuum Jacketed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2713\" data-end=\"2755\"\u003e\n\u003cp data-start=\"2715\" data-end=\"2755\"\u003eHeavy-wall laboratory glass construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2757\" data-end=\"2760\"\u003e\n\u003ch1 data-start=\"2762\" data-end=\"2775\"\u003eJoint Sizes\u003c\/h1\u003e\n\u003cul data-start=\"2777\" data-end=\"2982\"\u003e\n\u003cli data-start=\"2777\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2779\" data-end=\"2830\"\u003eBoiling Flask to Distillation Head: \u003cstrong data-start=\"2815\" data-end=\"2830\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2831\" data-end=\"2884\"\u003e\n\u003cp data-start=\"2833\" data-end=\"2884\"\u003eDistillation Head Thermometer Port: \u003cstrong data-start=\"2869\" data-end=\"2884\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2885\" data-end=\"2934\"\u003e\n\u003cp data-start=\"2887\" data-end=\"2934\"\u003eBoiling Flask Thermometer Port: \u003cstrong data-start=\"2919\" data-end=\"2934\"\u003e24\/20 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2935\" data-end=\"2982\"\u003e\n\u003cp data-start=\"2937\" data-end=\"2982\"\u003eReceiving Flask Connections: \u003cstrong data-start=\"2966\" data-end=\"2982\"\u003e24\/40 joints\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2984\" data-end=\"2987\"\u003e\n\u003ch1 data-start=\"2989\" data-end=\"3009\"\u003eSystem Connections\u003c\/h1\u003e\n\u003cul data-start=\"3011\" data-end=\"3102\"\u003e\n\u003cli data-start=\"3011\" data-end=\"3062\"\u003e\n\u003cp data-start=\"3013\" data-end=\"3062\"\u003eRecirculating Fluid Connection: \u003cstrong data-start=\"3045\" data-end=\"3062\"\u003eGL-16 adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3063\" data-end=\"3102\"\u003e\n\u003cp data-start=\"3065\" data-end=\"3102\"\u003eVacuum Connection: \u003cstrong data-start=\"3084\" data-end=\"3102\"\u003e3\/8\" hose barb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3104\" data-end=\"3107\"\u003e\n\u003ch1 data-start=\"3109\" data-end=\"3126\"\u003eWhat's Included\u003c\/h1\u003e\n\u003ch3 data-start=\"3128\" data-end=\"3158\"\u003eDistillation Head Assembly\u003c\/h3\u003e\n\u003cul data-start=\"3160\" data-end=\"3315\"\u003e\n\u003cli data-start=\"3160\" data-end=\"3315\"\u003e\n\u003cp data-start=\"3162\" data-end=\"3214\"\u003e\u003cstrong data-start=\"3162\" data-end=\"3214\"\u003e1 × Heavy Wall Vacuum Jacketed Distillation Head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3217\" data-end=\"3315\"\u003e\n\u003cli data-start=\"3217\" data-end=\"3257\"\u003e\n\u003cp data-start=\"3219\" data-end=\"3257\"\u003eMultiple Vigreux fractionation columns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3260\" data-end=\"3288\"\u003e\n\u003cp data-start=\"3262\" data-end=\"3288\"\u003eIntegrated cooling channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3291\" data-end=\"3315\"\u003e\n\u003cp data-start=\"3293\" data-end=\"3315\"\u003eTemperature probe port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3317\" data-end=\"3320\"\u003e\n\u003ch3 data-start=\"3322\" data-end=\"3339\"\u003eBoiling Flask\u003c\/h3\u003e\n\u003cul data-start=\"3341\" data-end=\"3461\"\u003e\n\u003cli data-start=\"3341\" data-end=\"3461\"\u003e\n\u003cp data-start=\"3343\" data-end=\"3387\"\u003e\u003cstrong data-start=\"3343\" data-end=\"3387\"\u003e1 × Heavy Wall 2-Neck Round Bottom Flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3390\" data-end=\"3461\"\u003e\n\u003cli data-start=\"3390\" data-end=\"3426\"\u003e\n\u003cp data-start=\"3392\" data-end=\"3426\"\u003eOne \u003cstrong data-start=\"3396\" data-end=\"3426\"\u003e34\/45 vertical center neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3429\" data-end=\"3461\"\u003e\n\u003cp data-start=\"3431\" data-end=\"3461\"\u003eOne \u003cstrong data-start=\"3435\" data-end=\"3461\"\u003e24\/40 angled side neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3463\" data-end=\"3466\"\u003e\n\u003ch3 data-start=\"3468\" data-end=\"3492\"\u003eThermometer Adapters\u003c\/h3\u003e\n\u003cul data-start=\"3494\" data-end=\"3560\"\u003e\n\u003cli data-start=\"3494\" data-end=\"3560\"\u003e\n\u003cp data-start=\"3496\" data-end=\"3560\"\u003e\u003cstrong data-start=\"3496\" data-end=\"3560\"\u003e2 × PTFE 24\/40 Thermometer Inlet Adapters with Viton Gaskets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3562\" data-end=\"3565\"\u003e\n\u003ch3 data-start=\"3567\" data-end=\"3587\"\u003eReceiving System\u003c\/h3\u003e\n\u003cul data-start=\"3589\" data-end=\"3659\"\u003e\n\u003cli data-start=\"3589\" data-end=\"3659\"\u003e\n\u003cp data-start=\"3591\" data-end=\"3659\"\u003e\u003cstrong data-start=\"3591\" data-end=\"3659\"\u003e2 × 500mL Heavy Wall Round Bottom Receiving Flasks (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3661\" data-end=\"3664\"\u003e\n\u003ch3 data-start=\"3666\" data-end=\"3687\"\u003eGlass Accessories\u003c\/h3\u003e\n\u003cul data-start=\"3689\" data-end=\"3883\"\u003e\n\u003cli data-start=\"3689\" data-end=\"3728\"\u003e\n\u003cp data-start=\"3691\" data-end=\"3728\"\u003e\u003cstrong data-start=\"3691\" data-end=\"3728\"\u003e1 × 24\/40 PennyHead Glass Stopper\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3729\" data-end=\"3775\"\u003e\n\u003cp data-start=\"3731\" data-end=\"3775\"\u003e\u003cstrong data-start=\"3731\" data-end=\"3775\"\u003e1 × 24\/40 Round-Top Glass Feeding Funnel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3776\" data-end=\"3840\"\u003e\n\u003cp data-start=\"3778\" data-end=\"3840\"\u003e\u003cstrong data-start=\"3778\" data-end=\"3840\"\u003e1 × Valved Adapter with Two 24\/40 Joints and One GL16 Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3841\" data-end=\"3883\"\u003e\n\u003cp data-start=\"3843\" data-end=\"3883\"\u003e\u003cstrong data-start=\"3843\" data-end=\"3883\"\u003e1 × Glass 3\/8\" Hose Barb Tee Adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3885\" data-end=\"3888\"\u003e\n\u003ch3 data-start=\"3890\" data-end=\"3913\"\u003eLaboratory Hardware\u003c\/h3\u003e\n\u003cul data-start=\"3915\" data-end=\"4006\"\u003e\n\u003cli data-start=\"3915\" data-end=\"3969\"\u003e\n\u003cp data-start=\"3917\" data-end=\"3969\"\u003e\u003cstrong data-start=\"3917\" data-end=\"3969\"\u003e2 × Stainless Steel Keck Clips (24\/40 and 34\/45)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3970\" data-end=\"4006\"\u003e\n\u003cp data-start=\"3972\" data-end=\"4006\"\u003e\u003cstrong data-start=\"3972\" data-end=\"4006\"\u003e3 × Plastic Keck Clips (24\/40)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4008\" data-end=\"4011\"\u003e\n\u003ch3 data-start=\"4013\" data-end=\"4045\"\u003eLaboratory Support Equipment\u003c\/h3\u003e\n\u003cul data-start=\"4047\" data-end=\"4213\"\u003e\n\u003cli data-start=\"4047\" data-end=\"4122\"\u003e\n\u003cp data-start=\"4049\" data-end=\"4073\"\u003e\u003cstrong data-start=\"4049\" data-end=\"4073\"\u003e2 × Cork Ring Stands\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4076\" data-end=\"4122\"\u003e\n\u003cli data-start=\"4076\" data-end=\"4096\"\u003e\n\u003cp data-start=\"4078\" data-end=\"4096\"\u003e1 for \u003cstrong data-start=\"4084\" data-end=\"4096\"\u003e2L flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4099\" data-end=\"4122\"\u003e\n\u003cp data-start=\"4101\" data-end=\"4122\"\u003e1 for \u003cstrong data-start=\"4107\" data-end=\"4122\"\u003e500mL flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4124\" data-end=\"4213\"\u003e\n\u003cp data-start=\"4126\" data-end=\"4158\"\u003e\u003cstrong data-start=\"4126\" data-end=\"4158\"\u003e1 × Stainless Steel Lab Jack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4161\" data-end=\"4213\"\u003e\n\u003cli data-start=\"4161\" data-end=\"4180\"\u003e\n\u003cp data-start=\"4163\" data-end=\"4180\"\u003eSize: \u003cstrong data-start=\"4169\" data-end=\"4180\"\u003e4\" × 4\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4183\" data-end=\"4213\"\u003e\n\u003cp data-start=\"4185\" data-end=\"4213\"\u003eHeight Range: \u003cstrong data-start=\"4199\" data-end=\"4213\"\u003e1.75\" – 6\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4215\" data-end=\"4218\"\u003e\n\u003ch3 data-start=\"4220\" data-end=\"4249\"\u003eMeasurement \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4251\" data-end=\"4349\"\u003e\n\u003cli data-start=\"4251\" data-end=\"4299\"\u003e\n\u003cp data-start=\"4253\" data-end=\"4299\"\u003e\u003cstrong data-start=\"4253\" data-end=\"4299\"\u003e1 × Traceable Kangaroo Digital Thermometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4300\" data-end=\"4349\"\u003e\n\u003cp data-start=\"4302\" data-end=\"4349\"\u003e\u003cstrong data-start=\"4302\" data-end=\"4349\"\u003e1 × Dow Corning High Vacuum Grease (5.3 oz)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4351\" data-end=\"4354\"\u003e\n\u003ch1 data-start=\"4356\" data-end=\"4374\"\u003eGlassware Notice\u003c\/h1\u003e\n\u003cp data-start=\"4376\" data-end=\"4431\"\u003eGlassware \u003cstrong data-start=\"4386\" data-end=\"4430\"\u003edoes not include a manufacturer warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4433\" data-end=\"4640\"\u003eMinor cosmetic blemishes may occur during manufacturing but \u003cstrong data-start=\"4493\" data-end=\"4541\"\u003ewill not affect performance or functionality\u003c\/strong\u003e. All glassware is inspected before shipping to ensure no defective products are sent to customers.\u003c\/p\u003e\n\u003chr data-start=\"4642\" data-end=\"4645\"\u003e\n\u003ch1 data-start=\"4647\" data-end=\"4688\"\u003eRecommended Equipment (Sold Separately)\u003c\/h1\u003e\n\u003cp data-start=\"4690\" data-end=\"4756\"\u003eFor full system operation, the following equipment is recommended:\u003c\/p\u003e\n\u003cul data-start=\"4758\" data-end=\"4832\"\u003e\n\u003cli data-start=\"4758\" data-end=\"4773\"\u003e\n\u003cp data-start=\"4760\" data-end=\"4773\"\u003eVacuum pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4774\" data-end=\"4799\"\u003e\n\u003cp data-start=\"4776\" data-end=\"4799\"\u003eRecirculating chiller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4800\" data-end=\"4818\"\u003e\n\u003cp data-start=\"4802\" data-end=\"4818\"\u003eHeating mantle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4819\" data-end=\"4832\"\u003e\n\u003cp data-start=\"4821\" data-end=\"4832\"\u003eCold trap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52127702319426,"sku":null,"price":970.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/clear2_newstdhead_1__clear2v1.jpg?v=1772745520"},{"product_id":"across-international-clear5-ai-5l-short-path-distillation-kit-with-multiple-receiving-flasks","title":"Across International Clear5 Ai 5L Short Path Distillation Kit with Multiple Receiving Flasks","description":"\u003cp data-start=\"628\" data-end=\"1007\"\u003eThe \u003cstrong data-start=\"632\" data-end=\"691\"\u003eAcross International Clear5 Short Path Distillation Kit\u003c\/strong\u003e is a professional \u003cstrong data-start=\"710\" data-end=\"751\"\u003e5-liter molecular distillation system\u003c\/strong\u003e designed for efficient purification and separation of heat-sensitive compounds. Featuring \u003cstrong data-start=\"842\" data-end=\"911\"\u003eheavy-wall borosilicate glass and a vacuum-jacketed vapor pathway\u003c\/strong\u003e, this short path distillation kit minimizes heat loss while maximizing condensation efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1009\" data-end=\"1305\"\u003eThe newly redesigned \u003cstrong data-start=\"1030\" data-end=\"1067\"\u003evacuum-jacketed distillation head\u003c\/strong\u003e features an expanded vapor channel and increased internal diameter, allowing for improved vapor flow and more efficient fractionation during distillation. This design helps prevent clogging while ensuring smooth and consistent operation.\u003c\/p\u003e\n\u003cp data-start=\"1307\" data-end=\"1498\"\u003eConstructed from \u003cstrong data-start=\"1324\" data-end=\"1363\"\u003ehigh-quality borosilicate glass 3.3\u003c\/strong\u003e, the Clear5 system delivers excellent chemical resistance, thermal stability, and durability for laboratory and research environments.\u003c\/p\u003e\n\u003cp data-start=\"1500\" data-end=\"1749\"\u003eThis kit includes the \u003cstrong data-start=\"1522\" data-end=\"1658\"\u003edistillation head, 5L boiling flask, receiving flasks, distribution adapters, thermometer adapters, and laboratory support equipment\u003c\/strong\u003e, making it a complete solution for small-to-mid scale molecular distillation applications.\u003c\/p\u003e\n\u003chr data-start=\"1751\" data-end=\"1754\"\u003e\n\u003ch1 data-start=\"1756\" data-end=\"1770\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-start=\"1772\" data-end=\"1820\"\u003eRedesigned Vacuum Jacketed Distillation Head\u003c\/h3\u003e\n\u003cul data-start=\"1821\" data-end=\"2001\"\u003e\n\u003cli data-start=\"1821\" data-end=\"1863\"\u003e\n\u003cp data-start=\"1823\" data-end=\"1863\"\u003eLarger vapor channel improves vapor flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1866\" data-end=\"1927\"\u003eIncreased internal diameter enhances fractionation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1928\" data-end=\"1967\"\u003e\n\u003cp data-start=\"1930\" data-end=\"1967\"\u003ePrevents clogging during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1968\" data-end=\"2001\"\u003e\n\u003cp data-start=\"1970\" data-end=\"2001\"\u003eVacuum jacket reduces heat loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2003\" data-end=\"2038\"\u003eHeavy Wall Laboratory Glassware\u003c\/h3\u003e\n\u003cul data-start=\"2039\" data-end=\"2164\"\u003e\n\u003cli data-start=\"2039\" data-end=\"2077\"\u003e\n\u003cp data-start=\"2041\" data-end=\"2077\"\u003eMade from \u003cstrong data-start=\"2051\" data-end=\"2077\"\u003eborosilicate glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2078\" data-end=\"2123\"\u003e\n\u003cp data-start=\"2080\" data-end=\"2123\"\u003eThick wall construction improves durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2124\" data-end=\"2164\"\u003e\n\u003cp data-start=\"2126\" data-end=\"2164\"\u003eExcellent resistance to thermal stress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2166\" data-end=\"2208\"\u003eHigh Efficiency Molecular Distillation\u003c\/h3\u003e\n\u003cul data-start=\"2209\" data-end=\"2317\"\u003e\n\u003cli data-start=\"2209\" data-end=\"2268\"\u003e\n\u003cp data-start=\"2211\" data-end=\"2268\"\u003eVacuum jacketed vapor channel improves vapor condensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2269\" data-end=\"2317\"\u003e\n\u003cp data-start=\"2271\" data-end=\"2317\"\u003eMaintains stable temperatures during operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2319\" data-end=\"2355\"\u003ePrecision Temperature Monitoring\u003c\/h3\u003e\n\u003cul data-start=\"2356\" data-end=\"2510\"\u003e\n\u003cli data-start=\"2356\" data-end=\"2435\"\u003e\n\u003cp data-start=\"2358\" data-end=\"2435\"\u003eThermometer ports located on both the \u003cstrong data-start=\"2396\" data-end=\"2435\"\u003eboiling flask and distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2436\" data-end=\"2510\"\u003e\n\u003cp data-start=\"2438\" data-end=\"2510\"\u003ePTFE thermometer adapters with \u003cstrong data-start=\"2469\" data-end=\"2486\"\u003eViton gaskets\u003c\/strong\u003e ensure airtight sealing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2512\" data-end=\"2543\"\u003eFlexible System Connections\u003c\/h3\u003e\n\u003cul data-start=\"2544\" data-end=\"2695\"\u003e\n\u003cli data-start=\"2544\" data-end=\"2600\"\u003e\n\u003cp data-start=\"2546\" data-end=\"2600\"\u003e\u003cstrong data-start=\"2546\" data-end=\"2564\"\u003eGL-16 adapters\u003c\/strong\u003e for recirculating fluid connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2601\" data-end=\"2640\"\u003e\n\u003cp data-start=\"2603\" data-end=\"2640\"\u003e\u003cstrong data-start=\"2603\" data-end=\"2640\"\u003e3\/8\" hose barb vacuum connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2641\" data-end=\"2695\"\u003e\n\u003cp data-start=\"2643\" data-end=\"2695\"\u003eCompatible with laboratory chillers and vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2697\" data-end=\"2723\"\u003eVacuum Pump Protection\u003c\/h3\u003e\n\u003cul data-start=\"2724\" data-end=\"2825\"\u003e\n\u003cli data-start=\"2724\" data-end=\"2775\"\u003e\n\u003cp data-start=\"2726\" data-end=\"2775\"\u003eCompatible with \u003cstrong data-start=\"2742\" data-end=\"2775\"\u003eoptional T1 or T40 cold traps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2776\" data-end=\"2825\"\u003e\n\u003cp data-start=\"2778\" data-end=\"2825\"\u003ePrevents vapors from contaminating vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2827\" data-end=\"2830\"\u003e\n\u003ch1 data-start=\"2832\" data-end=\"2852\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cul data-start=\"2854\" data-end=\"3064\"\u003e\n\u003cli data-start=\"2854\" data-end=\"2880\"\u003e\n\u003cp data-start=\"2856\" data-end=\"2880\"\u003eMolecular distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2881\" data-end=\"2921\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2921\"\u003eCannabis extraction and distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2922\" data-end=\"2952\"\u003e\n\u003cp data-start=\"2924\" data-end=\"2952\"\u003eEssential oil purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2953\" data-end=\"2991\"\u003e\n\u003cp data-start=\"2955\" data-end=\"2991\"\u003ePharmaceutical compound separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2992\" data-end=\"3028\"\u003e\n\u003cp data-start=\"2994\" data-end=\"3028\"\u003eLaboratory distillation research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3029\" data-end=\"3064\"\u003e\n\u003cp data-start=\"3031\" data-end=\"3064\"\u003eChemical purification processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3066\" data-end=\"3069\"\u003e\n\u003ch1 data-start=\"3071\" data-end=\"3097\"\u003eGlassware Specifications\u003c\/h1\u003e\n\u003cul data-start=\"3099\" data-end=\"3235\"\u003e\n\u003cli data-start=\"3099\" data-end=\"3148\"\u003e\n\u003cp data-start=\"3101\" data-end=\"3148\"\u003eGlass Material: \u003cstrong data-start=\"3117\" data-end=\"3148\"\u003eHigh Borosilicate Glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3149\" data-end=\"3192\"\u003e\n\u003cp data-start=\"3151\" data-end=\"3192\"\u003eDistillation Head: \u003cstrong data-start=\"3170\" data-end=\"3192\"\u003e5L Vacuum Jacketed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3193\" data-end=\"3235\"\u003e\n\u003cp data-start=\"3195\" data-end=\"3235\"\u003eHeavy wall laboratory glass construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3237\" data-end=\"3240\"\u003e\n\u003ch1 data-start=\"3242\" data-end=\"3255\"\u003eJoint Sizes\u003c\/h1\u003e\n\u003cul data-start=\"3257\" data-end=\"3456\"\u003e\n\u003cli data-start=\"3257\" data-end=\"3310\"\u003e\n\u003cp data-start=\"3259\" data-end=\"3310\"\u003eBoiling Flask to Distillation Head: \u003cstrong data-start=\"3295\" data-end=\"3310\"\u003e34\/45 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3311\" data-end=\"3360\"\u003e\n\u003cp data-start=\"3313\" data-end=\"3360\"\u003eBoiling Flask Thermometer Port: \u003cstrong data-start=\"3345\" data-end=\"3360\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3361\" data-end=\"3414\"\u003e\n\u003cp data-start=\"3363\" data-end=\"3414\"\u003eDistillation Head Thermometer Port: \u003cstrong data-start=\"3399\" data-end=\"3414\"\u003e14\/20 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3415\" data-end=\"3456\"\u003e\n\u003cp data-start=\"3417\" data-end=\"3456\"\u003eReceiving Flask Ports: \u003cstrong data-start=\"3440\" data-end=\"3456\"\u003e24\/40 joints\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3458\" data-end=\"3461\"\u003e\n\u003ch1 data-start=\"3463\" data-end=\"3483\"\u003eSystem Connections\u003c\/h1\u003e\n\u003cul data-start=\"3485\" data-end=\"3576\"\u003e\n\u003cli data-start=\"3485\" data-end=\"3536\"\u003e\n\u003cp data-start=\"3487\" data-end=\"3536\"\u003eRecirculating Fluid Connection: \u003cstrong data-start=\"3519\" data-end=\"3536\"\u003eGL-16 adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3537\" data-end=\"3576\"\u003e\n\u003cp data-start=\"3539\" data-end=\"3576\"\u003eVacuum Connection: \u003cstrong data-start=\"3558\" data-end=\"3576\"\u003e3\/8\" hose barb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3578\" data-end=\"3581\"\u003e\n\u003ch1 data-start=\"3583\" data-end=\"3605\"\u003eShipping Information\u003c\/h1\u003e\n\u003cul data-start=\"3607\" data-end=\"3683\"\u003e\n\u003cli data-start=\"3607\" data-end=\"3653\"\u003e\n\u003cp data-start=\"3609\" data-end=\"3653\"\u003eShipping Dimensions: \u003cstrong data-start=\"3630\" data-end=\"3653\"\u003e29 × 23 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3654\" data-end=\"3683\"\u003e\n\u003cp data-start=\"3656\" data-end=\"3683\"\u003eShipping Weight: \u003cstrong data-start=\"3673\" data-end=\"3683\"\u003e20 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3685\" data-end=\"3688\"\u003e\n\u003ch1 data-start=\"3690\" data-end=\"3707\"\u003eWhat's Included\u003c\/h1\u003e\n\u003ch3 data-start=\"3709\" data-end=\"3739\"\u003eDistillation Head Assembly\u003c\/h3\u003e\n\u003cul data-start=\"3741\" data-end=\"3893\"\u003e\n\u003cli data-start=\"3741\" data-end=\"3893\"\u003e\n\u003cp data-start=\"3743\" data-end=\"3798\"\u003e\u003cstrong data-start=\"3743\" data-end=\"3798\"\u003e1 × Heavy Wall Vacuum Jacketed 5L Distillation Head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3801\" data-end=\"3893\"\u003e\n\u003cli data-start=\"3801\" data-end=\"3841\"\u003e\n\u003cp data-start=\"3803\" data-end=\"3841\"\u003eMultiple Vigreux fractionation columns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3844\" data-end=\"3872\"\u003e\n\u003cp data-start=\"3846\" data-end=\"3872\"\u003eIntegrated cooling channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3875\" data-end=\"3893\"\u003e\n\u003cp data-start=\"3877\" data-end=\"3893\"\u003eThermometer port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3895\" data-end=\"3898\"\u003e\n\u003ch3 data-start=\"3900\" data-end=\"3917\"\u003eBoiling Flask\u003c\/h3\u003e\n\u003cul data-start=\"3919\" data-end=\"4027\"\u003e\n\u003cli data-start=\"3919\" data-end=\"4027\"\u003e\n\u003cp data-start=\"3921\" data-end=\"3965\"\u003e\u003cstrong data-start=\"3921\" data-end=\"3965\"\u003e1 × Heavy Wall 2-Neck Round Bottom Flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3968\" data-end=\"4027\"\u003e\n\u003cli data-start=\"3968\" data-end=\"3998\"\u003e\n\u003cp data-start=\"3970\" data-end=\"3998\"\u003eOne \u003cstrong data-start=\"3974\" data-end=\"3998\"\u003evertical center neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4001\" data-end=\"4027\"\u003e\n\u003cp data-start=\"4003\" data-end=\"4027\"\u003eOne \u003cstrong data-start=\"4007\" data-end=\"4027\"\u003eangled side neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4029\" data-end=\"4032\"\u003e\n\u003ch3 data-start=\"4034\" data-end=\"4058\"\u003eThermometer Adapters\u003c\/h3\u003e\n\u003cul data-start=\"4060\" data-end=\"4126\"\u003e\n\u003cli data-start=\"4060\" data-end=\"4126\"\u003e\n\u003cp data-start=\"4062\" data-end=\"4126\"\u003e\u003cstrong data-start=\"4062\" data-end=\"4126\"\u003e2 × PTFE 24\/40 Thermometer Inlet Adapters with Viton Gaskets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4128\" data-end=\"4131\"\u003e\n\u003ch3 data-start=\"4133\" data-end=\"4153\"\u003eReceiving System\u003c\/h3\u003e\n\u003cul data-start=\"4155\" data-end=\"4294\"\u003e\n\u003cli data-start=\"4155\" data-end=\"4225\"\u003e\n\u003cp data-start=\"4157\" data-end=\"4225\"\u003e\u003cstrong data-start=\"4157\" data-end=\"4225\"\u003e2 × 1000mL Heavy Wall Pear-Shaped Receiving Flasks (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4226\" data-end=\"4294\"\u003e\n\u003cp data-start=\"4228\" data-end=\"4294\"\u003e\u003cstrong data-start=\"4228\" data-end=\"4294\"\u003e1 × 500mL Heavy Wall Pear-Shaped Receiving Flask (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4296\" data-end=\"4299\"\u003e\n\u003ch3 data-start=\"4301\" data-end=\"4326\"\u003eDistribution Adapters\u003c\/h3\u003e\n\u003cul data-start=\"4328\" data-end=\"4487\"\u003e\n\u003cli data-start=\"4328\" data-end=\"4407\"\u003e\n\u003cp data-start=\"4330\" data-end=\"4407\"\u003e\u003cstrong data-start=\"4330\" data-end=\"4407\"\u003e1 × 250mL Distribution Adapter with Single Receiving Port and Vacuum Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4408\" data-end=\"4487\"\u003e\n\u003cp data-start=\"4410\" data-end=\"4487\"\u003e\u003cstrong data-start=\"4410\" data-end=\"4487\"\u003e1 × 250mL Distribution Adapter with Three Receiving Ports and Vacuum Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4489\" data-end=\"4492\"\u003e\n\u003ch3 data-start=\"4494\" data-end=\"4515\"\u003eGlass Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4517\" data-end=\"4646\"\u003e\n\u003cli data-start=\"4517\" data-end=\"4556\"\u003e\n\u003cp data-start=\"4519\" data-end=\"4556\"\u003e\u003cstrong data-start=\"4519\" data-end=\"4556\"\u003e1 × 24\/40 Pennyhead Glass Stopper\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4557\" data-end=\"4603\"\u003e\n\u003cp data-start=\"4559\" data-end=\"4603\"\u003e\u003cstrong data-start=\"4559\" data-end=\"4603\"\u003e1 × 24\/40 Round-Top Glass Feeding Funnel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4604\" data-end=\"4646\"\u003e\n\u003cp data-start=\"4606\" data-end=\"4646\"\u003e\u003cstrong data-start=\"4606\" data-end=\"4646\"\u003e1 × Glass 3\/8\" Hose Barb Tee Adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4648\" data-end=\"4651\"\u003e\n\u003ch3 data-start=\"4653\" data-end=\"4676\"\u003eLaboratory Hardware\u003c\/h3\u003e\n\u003cul data-start=\"4678\" data-end=\"4769\"\u003e\n\u003cli data-start=\"4678\" data-end=\"4732\"\u003e\n\u003cp data-start=\"4680\" data-end=\"4732\"\u003e\u003cstrong data-start=\"4680\" data-end=\"4732\"\u003e2 × Stainless Steel Keck Clips (24\/40 and 34\/45)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4733\" data-end=\"4769\"\u003e\n\u003cp data-start=\"4735\" data-end=\"4769\"\u003e\u003cstrong data-start=\"4735\" data-end=\"4769\"\u003e3 × Plastic Keck Clips (24\/40)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4771\" data-end=\"4774\"\u003e\n\u003ch3 data-start=\"4776\" data-end=\"4808\"\u003eLaboratory Support Equipment\u003c\/h3\u003e\n\u003cul data-start=\"4810\" data-end=\"4991\"\u003e\n\u003cli data-start=\"4810\" data-end=\"4896\"\u003e\n\u003cp data-start=\"4812\" data-end=\"4836\"\u003e\u003cstrong data-start=\"4812\" data-end=\"4836\"\u003e2 × Cork Ring Stands\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4839\" data-end=\"4896\"\u003e\n\u003cli data-start=\"4839\" data-end=\"4861\"\u003e\n\u003cp data-start=\"4841\" data-end=\"4861\"\u003eOne for \u003cstrong data-start=\"4849\" data-end=\"4861\"\u003e5L flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4864\" data-end=\"4896\"\u003e\n\u003cp data-start=\"4866\" data-end=\"4896\"\u003eOne for \u003cstrong data-start=\"4874\" data-end=\"4896\"\u003e1L receiving flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4898\" data-end=\"4991\"\u003e\n\u003cp data-start=\"4900\" data-end=\"4932\"\u003e\u003cstrong data-start=\"4900\" data-end=\"4932\"\u003e1 × Stainless Steel Lab Jack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4935\" data-end=\"4991\"\u003e\n\u003cli data-start=\"4935\" data-end=\"4959\"\u003e\n\u003cp data-start=\"4937\" data-end=\"4959\"\u003eSize: \u003cstrong data-start=\"4943\" data-end=\"4959\"\u003e6 × 6 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4962\" data-end=\"4991\"\u003e\n\u003cp data-start=\"4964\" data-end=\"4991\"\u003eHeight Range: \u003cstrong data-start=\"4978\" data-end=\"4991\"\u003e3\" – 9.5\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4993\" data-end=\"4996\"\u003e\n\u003ch3 data-start=\"4998\" data-end=\"5027\"\u003eMeasurement \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul data-start=\"5029\" data-end=\"5127\"\u003e\n\u003cli data-start=\"5029\" data-end=\"5077\"\u003e\n\u003cp data-start=\"5031\" data-end=\"5077\"\u003e\u003cstrong data-start=\"5031\" data-end=\"5077\"\u003e1 × Traceable Kangaroo Digital Thermometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5078\" data-end=\"5127\"\u003e\n\u003cp data-start=\"5080\" data-end=\"5127\"\u003e\u003cstrong data-start=\"5080\" data-end=\"5127\"\u003e1 × Dow Corning High Vacuum Grease (5.3 oz)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5129\" data-end=\"5132\"\u003e\n\u003ch1 data-start=\"5134\" data-end=\"5152\"\u003eGlassware Notice\u003c\/h1\u003e\n\u003cp data-start=\"5154\" data-end=\"5209\"\u003eGlassware \u003cstrong data-start=\"5164\" data-end=\"5208\"\u003edoes not include a manufacturer warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5211\" data-end=\"5405\"\u003eMinor cosmetic blemishes may occur during manufacturing but \u003cstrong data-start=\"5271\" data-end=\"5304\"\u003ewill not affect functionality\u003c\/strong\u003e. All glassware is inspected before shipping to ensure no defective components are sent to customers.\u003c\/p\u003e\n\u003chr data-start=\"5407\" data-end=\"5410\"\u003e\n\u003ch1 data-start=\"5412\" data-end=\"5453\"\u003eRecommended Equipment (Sold Separately)\u003c\/h1\u003e\n\u003cp data-start=\"5455\" data-end=\"5525\"\u003eFor complete system operation, the following equipment is recommended:\u003c\/p\u003e\n\u003cul data-start=\"5527\" data-end=\"5601\"\u003e\n\u003cli data-start=\"5527\" data-end=\"5542\"\u003e\n\u003cp data-start=\"5529\" data-end=\"5542\"\u003eVacuum pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5543\" data-end=\"5568\"\u003e\n\u003cp data-start=\"5545\" data-end=\"5568\"\u003eRecirculating chiller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5569\" data-end=\"5587\"\u003e\n\u003cp data-start=\"5571\" data-end=\"5587\"\u003eHeating mantle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5588\" data-end=\"5601\"\u003e\n\u003cp data-start=\"5590\" data-end=\"5601\"\u003eCold trap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52127707758914,"sku":null,"price":1340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/clear5-b_clear5_1_af6306a0-333c-4d7e-b6eb-5d79d688e1d0.jpg?v=1773937436"},{"product_id":"across-international-clear5v-ai-5-liter-short-path-distillation-kit-with-valved-adapter","title":"Across International Clear5v Ai 5 Liter Short Path Distillation Kit with Valved Adapter","description":"\u003cp data-start=\"532\" data-end=\"910\"\u003eThe \u003cstrong data-start=\"536\" data-end=\"595\"\u003eAcross International Clear5 Short Path Distillation Kit\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"618\" data-end=\"654\"\u003e5L molecular distillation system\u003c\/strong\u003e designed for efficient purification and separation of heat-sensitive compounds. Built with \u003cstrong data-start=\"746\" data-end=\"815\"\u003eheavy-wall borosilicate glass and a vacuum-jacketed vapor pathway\u003c\/strong\u003e, this system minimizes heat loss while maximizing condensation efficiency during distillation.\u003c\/p\u003e\n\u003cp data-start=\"912\" data-end=\"1197\"\u003eThe redesigned \u003cstrong data-start=\"927\" data-end=\"964\"\u003evacuum jacketed distillation head\u003c\/strong\u003e features a larger vapor channel and increased internal diameter, allowing for improved vapor flow and more efficient fractionation. This design helps prevent clogging and ensures smooth operation throughout the distillation process.\u003c\/p\u003e\n\u003cp data-start=\"1199\" data-end=\"1377\"\u003eConstructed from \u003cstrong data-start=\"1216\" data-end=\"1255\"\u003ehigh-quality borosilicate glass 3.3\u003c\/strong\u003e, the Clear5 system provides excellent thermal stability, chemical resistance, and durability for laboratory environments.\u003c\/p\u003e\n\u003cp data-start=\"1379\" data-end=\"1668\"\u003eThis kit includes the \u003cstrong data-start=\"1401\" data-end=\"1512\"\u003e5L distillation head, boiling flask, receiving flasks, adapters, thermometer ports, and support accessories\u003c\/strong\u003e, making it an ideal solution for \u003cstrong data-start=\"1546\" data-end=\"1667\"\u003elaboratory distillation, cannabis extraction research, chemical purification, and molecular distillation applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1670\" data-end=\"1673\"\u003e\n\u003ch1 data-start=\"1675\" data-end=\"1689\"\u003eKey Features\u003c\/h1\u003e\n\u003ch3 data-start=\"1691\" data-end=\"1739\"\u003eRedesigned Vacuum Jacketed Distillation Head\u003c\/h3\u003e\n\u003cul data-start=\"1740\" data-end=\"1920\"\u003e\n\u003cli data-start=\"1740\" data-end=\"1782\"\u003e\n\u003cp data-start=\"1742\" data-end=\"1782\"\u003eLarger vapor channel improves vapor flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1846\"\u003e\n\u003cp data-start=\"1785\" data-end=\"1846\"\u003eIncreased internal diameter enhances fractionation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1847\" data-end=\"1886\"\u003e\n\u003cp data-start=\"1849\" data-end=\"1886\"\u003ePrevents clogging during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1887\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1889\" data-end=\"1920\"\u003eVacuum jacket reduces heat loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1922\" data-end=\"1957\"\u003eHeavy Wall Laboratory Glassware\u003c\/h3\u003e\n\u003cul data-start=\"1958\" data-end=\"2083\"\u003e\n\u003cli data-start=\"1958\" data-end=\"1996\"\u003e\n\u003cp data-start=\"1960\" data-end=\"1996\"\u003eMade from \u003cstrong data-start=\"1970\" data-end=\"1996\"\u003eborosilicate glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1997\" data-end=\"2042\"\u003e\n\u003cp data-start=\"1999\" data-end=\"2042\"\u003eThick wall construction improves durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2043\" data-end=\"2083\"\u003e\n\u003cp data-start=\"2045\" data-end=\"2083\"\u003eExcellent resistance to thermal stress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2085\" data-end=\"2121\"\u003eEfficient Molecular Distillation\u003c\/h3\u003e\n\u003cul data-start=\"2122\" data-end=\"2237\"\u003e\n\u003cli data-start=\"2122\" data-end=\"2186\"\u003e\n\u003cp data-start=\"2124\" data-end=\"2186\"\u003eVacuum jacketed vapor channel improves condensation efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2187\" data-end=\"2237\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2237\"\u003eMaintains stable temperature during distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2239\" data-end=\"2275\"\u003ePrecision Temperature Monitoring\u003c\/h3\u003e\n\u003cul data-start=\"2276\" data-end=\"2430\"\u003e\n\u003cli data-start=\"2276\" data-end=\"2355\"\u003e\n\u003cp data-start=\"2278\" data-end=\"2355\"\u003eThermometer ports located on both the \u003cstrong data-start=\"2316\" data-end=\"2355\"\u003eboiling flask and distillation head\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2356\" data-end=\"2430\"\u003e\n\u003cp data-start=\"2358\" data-end=\"2430\"\u003ePTFE thermometer adapters with \u003cstrong data-start=\"2389\" data-end=\"2406\"\u003eViton gaskets\u003c\/strong\u003e ensure airtight sealing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2432\" data-end=\"2463\"\u003eFlexible System Connections\u003c\/h3\u003e\n\u003cul data-start=\"2464\" data-end=\"2627\"\u003e\n\u003cli data-start=\"2464\" data-end=\"2520\"\u003e\n\u003cp data-start=\"2466\" data-end=\"2520\"\u003e\u003cstrong data-start=\"2466\" data-end=\"2484\"\u003eGL-16 adapters\u003c\/strong\u003e for recirculating fluid connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2521\" data-end=\"2572\"\u003e\n\u003cp data-start=\"2523\" data-end=\"2572\"\u003e\u003cstrong data-start=\"2523\" data-end=\"2553\"\u003e3\/8\" hose barb connections\u003c\/strong\u003e for vacuum systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2573\" data-end=\"2627\"\u003e\n\u003cp data-start=\"2575\" data-end=\"2627\"\u003eCompatible with laboratory chillers and vacuum pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2629\" data-end=\"2632\"\u003e\n\u003ch1 data-start=\"2634\" data-end=\"2654\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cul data-start=\"2656\" data-end=\"2866\"\u003e\n\u003cli data-start=\"2656\" data-end=\"2682\"\u003e\n\u003cp data-start=\"2658\" data-end=\"2682\"\u003eMolecular distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2683\" data-end=\"2723\"\u003e\n\u003cp data-start=\"2685\" data-end=\"2723\"\u003eCannabis extraction and distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2724\" data-end=\"2754\"\u003e\n\u003cp data-start=\"2726\" data-end=\"2754\"\u003eEssential oil purification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2755\" data-end=\"2793\"\u003e\n\u003cp data-start=\"2757\" data-end=\"2793\"\u003ePharmaceutical compound separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2794\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2796\" data-end=\"2830\"\u003eLaboratory distillation research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2831\" data-end=\"2866\"\u003e\n\u003cp data-start=\"2833\" data-end=\"2866\"\u003eChemical purification processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2868\" data-end=\"2871\"\u003e\n\u003ch1 data-start=\"2873\" data-end=\"2899\"\u003eGlassware Specifications\u003c\/h1\u003e\n\u003cul data-start=\"2901\" data-end=\"3034\"\u003e\n\u003cli data-start=\"2901\" data-end=\"2950\"\u003e\n\u003cp data-start=\"2903\" data-end=\"2950\"\u003eGlass Material: \u003cstrong data-start=\"2919\" data-end=\"2950\"\u003eHigh Borosilicate Glass 3.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2951\" data-end=\"2991\"\u003e\n\u003cp data-start=\"2953\" data-end=\"2991\"\u003eDistillation Head: \u003cstrong data-start=\"2972\" data-end=\"2991\"\u003eVacuum Jacketed\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2992\" data-end=\"3034\"\u003e\n\u003cp data-start=\"2994\" data-end=\"3034\"\u003eHeavy-wall laboratory glass construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3036\" data-end=\"3039\"\u003e\n\u003ch1 data-start=\"3041\" data-end=\"3054\"\u003eJoint Sizes\u003c\/h1\u003e\n\u003cul data-start=\"3056\" data-end=\"3255\"\u003e\n\u003cli data-start=\"3056\" data-end=\"3109\"\u003e\n\u003cp data-start=\"3058\" data-end=\"3109\"\u003eBoiling Flask to Distillation Head: \u003cstrong data-start=\"3094\" data-end=\"3109\"\u003e34\/45 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3110\" data-end=\"3159\"\u003e\n\u003cp data-start=\"3112\" data-end=\"3159\"\u003eBoiling Flask Thermometer Port: \u003cstrong data-start=\"3144\" data-end=\"3159\"\u003e24\/40 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3160\" data-end=\"3213\"\u003e\n\u003cp data-start=\"3162\" data-end=\"3213\"\u003eDistillation Head Thermometer Port: \u003cstrong data-start=\"3198\" data-end=\"3213\"\u003e14\/20 joint\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3214\" data-end=\"3255\"\u003e\n\u003cp data-start=\"3216\" data-end=\"3255\"\u003eReceiving Flask Ports: \u003cstrong data-start=\"3239\" data-end=\"3255\"\u003e24\/40 joints\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3257\" data-end=\"3260\"\u003e\n\u003ch1 data-start=\"3262\" data-end=\"3282\"\u003eSystem Connections\u003c\/h1\u003e\n\u003cul data-start=\"3284\" data-end=\"3375\"\u003e\n\u003cli data-start=\"3284\" data-end=\"3335\"\u003e\n\u003cp data-start=\"3286\" data-end=\"3335\"\u003eRecirculating Fluid Connection: \u003cstrong data-start=\"3318\" data-end=\"3335\"\u003eGL-16 adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3336\" data-end=\"3375\"\u003e\n\u003cp data-start=\"3338\" data-end=\"3375\"\u003eVacuum Connection: \u003cstrong data-start=\"3357\" data-end=\"3375\"\u003e3\/8\" hose barb\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3377\" data-end=\"3380\"\u003e\n\u003ch1 data-start=\"3382\" data-end=\"3399\"\u003eWhat's Included\u003c\/h1\u003e\n\u003ch3 data-start=\"3401\" data-end=\"3431\"\u003eDistillation Head Assembly\u003c\/h3\u003e\n\u003cul data-start=\"3433\" data-end=\"3591\"\u003e\n\u003cli data-start=\"3433\" data-end=\"3591\"\u003e\n\u003cp data-start=\"3435\" data-end=\"3490\"\u003e\u003cstrong data-start=\"3435\" data-end=\"3490\"\u003e1 × Heavy Wall Vacuum Jacketed 5L Distillation Head\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3493\" data-end=\"3591\"\u003e\n\u003cli data-start=\"3493\" data-end=\"3533\"\u003e\n\u003cp data-start=\"3495\" data-end=\"3533\"\u003eMultiple Vigreux fractionation columns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3536\" data-end=\"3564\"\u003e\n\u003cp data-start=\"3538\" data-end=\"3564\"\u003eIntegrated cooling channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3567\" data-end=\"3591\"\u003e\n\u003cp data-start=\"3569\" data-end=\"3591\"\u003e14\/20 thermometer port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3593\" data-end=\"3596\"\u003e\n\u003ch3 data-start=\"3598\" data-end=\"3615\"\u003eBoiling Flask\u003c\/h3\u003e\n\u003cul data-start=\"3617\" data-end=\"3725\"\u003e\n\u003cli data-start=\"3617\" data-end=\"3725\"\u003e\n\u003cp data-start=\"3619\" data-end=\"3663\"\u003e\u003cstrong data-start=\"3619\" data-end=\"3663\"\u003e1 × Heavy Wall 2-Neck Round Bottom Flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3666\" data-end=\"3725\"\u003e\n\u003cli data-start=\"3666\" data-end=\"3696\"\u003e\n\u003cp data-start=\"3668\" data-end=\"3696\"\u003eOne \u003cstrong data-start=\"3672\" data-end=\"3696\"\u003evertical center neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3699\" data-end=\"3725\"\u003e\n\u003cp data-start=\"3701\" data-end=\"3725\"\u003eOne \u003cstrong data-start=\"3705\" data-end=\"3725\"\u003eangled side neck\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3727\" data-end=\"3730\"\u003e\n\u003ch3 data-start=\"3732\" data-end=\"3756\"\u003eThermometer Adapters\u003c\/h3\u003e\n\u003cul data-start=\"3758\" data-end=\"3824\"\u003e\n\u003cli data-start=\"3758\" data-end=\"3824\"\u003e\n\u003cp data-start=\"3760\" data-end=\"3824\"\u003e\u003cstrong data-start=\"3760\" data-end=\"3824\"\u003e2 × PTFE 24\/40 Thermometer Inlet Adapters with Viton Gaskets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3826\" data-end=\"3829\"\u003e\n\u003ch3 data-start=\"3831\" data-end=\"3851\"\u003eReceiving System\u003c\/h3\u003e\n\u003cul data-start=\"3853\" data-end=\"3923\"\u003e\n\u003cli data-start=\"3853\" data-end=\"3923\"\u003e\n\u003cp data-start=\"3855\" data-end=\"3923\"\u003e\u003cstrong data-start=\"3855\" data-end=\"3923\"\u003e2 × 500mL Heavy Wall Round Bottom Receiving Flasks (24\/40 joint)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3925\" data-end=\"3928\"\u003e\n\u003ch3 data-start=\"3930\" data-end=\"3951\"\u003eGlass Accessories\u003c\/h3\u003e\n\u003cul data-start=\"3953\" data-end=\"4148\"\u003e\n\u003cli data-start=\"3953\" data-end=\"3992\"\u003e\n\u003cp data-start=\"3955\" data-end=\"3992\"\u003e\u003cstrong data-start=\"3955\" data-end=\"3992\"\u003e1 × 24\/40 Pennyhead Glass Stopper\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3993\" data-end=\"4039\"\u003e\n\u003cp data-start=\"3995\" data-end=\"4039\"\u003e\u003cstrong data-start=\"3995\" data-end=\"4039\"\u003e1 × 24\/40 Round-Top Glass Feeding Funnel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4040\" data-end=\"4105\"\u003e\n\u003cp data-start=\"4042\" data-end=\"4105\"\u003e\u003cstrong data-start=\"4042\" data-end=\"4105\"\u003e1 × Valved Adapter with Two 24\/40 Joints and One GL-16 Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4106\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4108\" data-end=\"4148\"\u003e\u003cstrong data-start=\"4108\" data-end=\"4148\"\u003e1 × Glass 3\/8\" Hose Barb Tee Adapter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4150\" data-end=\"4153\"\u003e\n\u003ch3 data-start=\"4155\" data-end=\"4178\"\u003eLaboratory Hardware\u003c\/h3\u003e\n\u003cul data-start=\"4180\" data-end=\"4271\"\u003e\n\u003cli data-start=\"4180\" data-end=\"4234\"\u003e\n\u003cp data-start=\"4182\" data-end=\"4234\"\u003e\u003cstrong data-start=\"4182\" data-end=\"4234\"\u003e2 × Stainless Steel Keck Clips (24\/40 and 34\/45)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4235\" data-end=\"4271\"\u003e\n\u003cp data-start=\"4237\" data-end=\"4271\"\u003e\u003cstrong data-start=\"4237\" data-end=\"4271\"\u003e3 × Plastic Keck Clips (24\/40)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4273\" data-end=\"4276\"\u003e\n\u003ch3 data-start=\"4278\" data-end=\"4310\"\u003eLaboratory Support Equipment\u003c\/h3\u003e\n\u003cul data-start=\"4312\" data-end=\"4493\"\u003e\n\u003cli data-start=\"4312\" data-end=\"4398\"\u003e\n\u003cp data-start=\"4314\" data-end=\"4338\"\u003e\u003cstrong data-start=\"4314\" data-end=\"4338\"\u003e2 × Cork Ring Stands\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4341\" data-end=\"4398\"\u003e\n\u003cli data-start=\"4341\" data-end=\"4363\"\u003e\n\u003cp data-start=\"4343\" data-end=\"4363\"\u003eOne for \u003cstrong data-start=\"4351\" data-end=\"4363\"\u003e5L flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4366\" data-end=\"4398\"\u003e\n\u003cp data-start=\"4368\" data-end=\"4398\"\u003eOne for \u003cstrong data-start=\"4376\" data-end=\"4398\"\u003e1L receiving flask\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4400\" data-end=\"4493\"\u003e\n\u003cp data-start=\"4402\" data-end=\"4434\"\u003e\u003cstrong data-start=\"4402\" data-end=\"4434\"\u003e1 × Stainless Steel Lab Jack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4437\" data-end=\"4493\"\u003e\n\u003cli data-start=\"4437\" data-end=\"4461\"\u003e\n\u003cp data-start=\"4439\" data-end=\"4461\"\u003eSize: \u003cstrong data-start=\"4445\" data-end=\"4461\"\u003e6 × 6 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4464\" data-end=\"4493\"\u003e\n\u003cp data-start=\"4466\" data-end=\"4493\"\u003eHeight Range: \u003cstrong data-start=\"4480\" data-end=\"4493\"\u003e3\" – 9.5\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4495\" data-end=\"4498\"\u003e\n\u003ch3 data-start=\"4500\" data-end=\"4529\"\u003eMeasurement \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul data-start=\"4531\" data-end=\"4629\"\u003e\n\u003cli data-start=\"4531\" data-end=\"4579\"\u003e\n\u003cp data-start=\"4533\" data-end=\"4579\"\u003e\u003cstrong data-start=\"4533\" data-end=\"4579\"\u003e1 × Traceable Kangaroo Digital Thermometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4580\" data-end=\"4629\"\u003e\n\u003cp data-start=\"4582\" data-end=\"4629\"\u003e\u003cstrong data-start=\"4582\" data-end=\"4629\"\u003e1 × Dow Corning High Vacuum Grease (5.3 oz)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4631\" data-end=\"4634\"\u003e\n\u003ch1 data-start=\"4636\" data-end=\"4654\"\u003eGlassware Notice\u003c\/h1\u003e\n\u003cp data-start=\"4656\" data-end=\"4711\"\u003eGlassware \u003cstrong data-start=\"4666\" data-end=\"4710\"\u003edoes not include a manufacturer warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4713\" data-end=\"4924\"\u003eMinor cosmetic blemishes may occur during manufacturing but \u003cstrong data-start=\"4773\" data-end=\"4821\"\u003ewill not affect performance or functionality\u003c\/strong\u003e. All glassware is inspected prior to shipping to ensure no defective components are sent to customers.\u003c\/p\u003e\n\u003chr data-start=\"4926\" data-end=\"4929\"\u003e\n\u003ch1 data-start=\"4931\" data-end=\"4972\"\u003eRecommended Equipment (Sold Separately)\u003c\/h1\u003e\n\u003cp data-start=\"4974\" data-end=\"5036\"\u003eFor optimal operation, the following equipment is recommended:\u003c\/p\u003e\n\u003cul data-start=\"5038\" data-end=\"5112\"\u003e\n\u003cli data-start=\"5038\" data-end=\"5053\"\u003e\n\u003cp data-start=\"5040\" data-end=\"5053\"\u003eVacuum pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5054\" data-end=\"5079\"\u003e\n\u003cp data-start=\"5056\" data-end=\"5079\"\u003eRecirculating chiller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5080\" data-end=\"5098\"\u003e\n\u003cp data-start=\"5082\" data-end=\"5098\"\u003eHeating mantle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5099\" data-end=\"5112\"\u003e\n\u003cp data-start=\"5101\" data-end=\"5112\"\u003eCold trap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52127710314818,"sku":null,"price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/clear5-vcow_clear5v_1_5261bbbf-f673-4bd7-910f-3111678fb715.jpg?v=1773972065"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/collections\/Short_Path_Distillation_Systems_with_white_back_round.jpg?v=1772745007","url":"https:\/\/summitsupplydirect.com\/collections\/short-path-distillation-systems.oembed","provider":"Summit Supply Direct","version":"1.0","type":"link"}