{"title":"Laboratory Balances","description":"","products":[{"product_id":"across-international-wlc-60-c2-r-radwag-60kg-capacity-1g-readability-16x20-precision-balance","title":"Across International WLC 60\/C2\/R Radwag 60Kg Capacity 1g Readability 16x20\" Precision Balance","description":"\u003ch2 data-section-id=\"9rr9s2\" data-start=\"362\" data-end=\"435\"\u003eHigh-Capacity Precision Balance for Laboratory and Industrial Weighing\u003c\/h2\u003e\n\u003cp data-start=\"437\" data-end=\"783\"\u003eThe \u003cstrong data-start=\"441\" data-end=\"481\"\u003eRadwag WLC-60-C2-R Precision Balance\u003c\/strong\u003e is a high-performance laboratory balance designed for \u003cstrong data-start=\"536\" data-end=\"618\"\u003efast and accurate mass determination in laboratory and industrial environments\u003c\/strong\u003e. With a \u003cstrong data-start=\"627\" data-end=\"673\"\u003e60 kg maximum capacity and 1 g readability\u003c\/strong\u003e, this precision balance is ideal for weighing larger samples while maintaining reliable measurement accuracy.\u003c\/p\u003e\n\u003cp data-start=\"785\" data-end=\"1008\"\u003eThe balance features a \u003cstrong data-start=\"808\" data-end=\"927\"\u003edurable stainless steel weighing pan, backlit LCD display, RS232 connectivity, and an internal rechargeable battery\u003c\/strong\u003e, allowing operation even in environments where access to mains power is limited.\u003c\/p\u003e\n\u003cp data-start=\"1010\" data-end=\"1318\"\u003eEngineered by \u003cstrong data-start=\"1024\" data-end=\"1034\"\u003eRadwag\u003c\/strong\u003e, a global leader in precision weighing technology, the WLC series balances provide advanced weighing functions such as \u003cstrong data-start=\"1154\" data-end=\"1221\"\u003eparts counting, percent weighing, totalizing, and checkweighing\u003c\/strong\u003e, making them suitable for laboratories, production facilities, and quality control environments.\u003c\/p\u003e\n\u003chr data-start=\"1320\" data-end=\"1323\"\u003e\n\u003ch1 data-section-id=\"4fck0w\" data-start=\"1325\" data-end=\"1383\"\u003eKey Features of the Radwag WLC-60-C2-R Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1cka0dx\" data-start=\"1385\" data-end=\"1427\"\u003eHigh Capacity with Precise Readability\u003c\/h3\u003e\n\u003cp data-start=\"1428\" data-end=\"1545\"\u003eSupports \u003cstrong data-start=\"1437\" data-end=\"1469\"\u003eup to 60 kg maximum capacity\u003c\/strong\u003e with \u003cstrong data-start=\"1475\" data-end=\"1494\"\u003e1 g readability\u003c\/strong\u003e, providing accurate measurement for large samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"j0jxsj\" data-start=\"1547\" data-end=\"1590\"\u003eLarge Stainless Steel Weighing Platform\u003c\/h3\u003e\n\u003cp data-start=\"1591\" data-end=\"1691\"\u003eThe \u003cstrong data-start=\"1595\" data-end=\"1644\"\u003e15.7 × 19.7 inch stainless steel weighing pan\u003c\/strong\u003e provides ample space for weighing bulky items.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"1693\" data-end=\"1716\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1717\" data-end=\"1847\"\u003eHigh-contrast \u003cstrong data-start=\"1731\" data-end=\"1753\"\u003ebacklit LCD screen\u003c\/strong\u003e ensures clear reading of measurement results in laboratory or industrial lighting conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ype4r\" data-start=\"1849\" data-end=\"1882\"\u003eInternal Rechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"1883\" data-end=\"1989\"\u003eIntegrated \u003cstrong data-start=\"1894\" data-end=\"1928\"\u003esealed lead-acid (SLA) battery\u003c\/strong\u003e allows operation for up to \u003cstrong data-start=\"1956\" data-end=\"1988\"\u003e10 hours without mains power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1sypk8h\" data-start=\"1991\" data-end=\"2013\"\u003eRS232 Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2014\" data-end=\"2119\"\u003eBuilt-in \u003cstrong data-start=\"2023\" data-end=\"2042\"\u003eRS232 interface\u003c\/strong\u003e enables communication with computers, printers, and laboratory data systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"th3z8x\" data-start=\"2121\" data-end=\"2152\"\u003eOptional Wi-Fi Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2153\" data-end=\"2246\"\u003eOptional \u003cstrong data-start=\"2162\" data-end=\"2192\"\u003eWi-Fi communication module\u003c\/strong\u003e allows wireless integration with laboratory networks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"397j4q\" data-start=\"2248\" data-end=\"2277\"\u003eDurable Industrial Design\u003c\/h3\u003e\n\u003cp data-start=\"2278\" data-end=\"2372\"\u003eRated \u003cstrong data-start=\"2284\" data-end=\"2309\"\u003eIP43 protection class\u003c\/strong\u003e, offering protection against dust and light moisture exposure.\u003c\/p\u003e\n\u003chr data-start=\"2374\" data-end=\"2377\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"2379\" data-end=\"2408\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"2410\" data-end=\"2530\"\u003eThe WLC series balances include several professional weighing modes designed for laboratory and industrial applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlrqzv\" data-start=\"2532\" data-end=\"2570\"\u003eCheckweighing (Plus\/Minus Control)\u003c\/h3\u003e\n\u003cp data-start=\"2571\" data-end=\"2743\"\u003eAllows sample mass verification using \u003cstrong data-start=\"2609\" data-end=\"2643\"\u003edefined MIN and MAX thresholds\u003c\/strong\u003e. A visual \u003cstrong data-start=\"2654\" data-end=\"2677\"\u003ebar graph indicator\u003c\/strong\u003e shows whether the measured weight falls within acceptable limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"2745\" data-end=\"2765\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"2766\" data-end=\"2913\"\u003eEnables comparison of measured samples to a \u003cstrong data-start=\"2810\" data-end=\"2844\"\u003ereference mass standard (100%)\u003c\/strong\u003e, displaying results as a percentage relative to the reference value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"2915\" data-end=\"2929\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"2930\" data-end=\"3080\"\u003eAllows multiple measurements to be \u003cstrong data-start=\"2965\" data-end=\"2997\"\u003eadded together automatically\u003c\/strong\u003e, useful for determining the total mass of mixtures composed of several components.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3082\" data-end=\"3100\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3101\" data-end=\"3270\"\u003eCalculates the number of items based on total weight and known individual item mass. The system includes \u003cstrong data-start=\"3206\" data-end=\"3239\"\u003eautomatic accuracy correction\u003c\/strong\u003e to improve counting precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3272\" data-end=\"3285\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3286\" data-end=\"3426\"\u003eCaptures and displays the \u003cstrong data-start=\"3312\" data-end=\"3366\"\u003ehighest weight reading during the weighing process\u003c\/strong\u003e, commonly used in medical or dynamic weighing applications.\u003c\/p\u003e\n\u003chr data-start=\"3428\" data-end=\"3431\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3433\" data-end=\"3453\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3455\" data-end=\"3507\"\u003eThe Radwag WLC-60-C2-R balance is commonly used for:\u003c\/p\u003e\n\u003cul data-start=\"3509\" data-end=\"3736\"\u003e\n\u003cli data-section-id=\"c17ahl\" data-start=\"3509\" data-end=\"3537\"\u003e\n\u003cp data-start=\"3511\" data-end=\"3537\"\u003eLaboratory sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"52ibyd\" data-start=\"3538\" data-end=\"3566\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3566\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"faa4rs\" data-start=\"3567\" data-end=\"3600\"\u003e\n\u003cp data-start=\"3569\" data-end=\"3600\"\u003eParts counting in manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mb1wue\" data-start=\"3601\" data-end=\"3620\"\u003e\n\u003cp data-start=\"3603\" data-end=\"3620\"\u003eBatch formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gjfy1b\" data-start=\"3621\" data-end=\"3659\"\u003e\n\u003cp data-start=\"3623\" data-end=\"3659\"\u003eMaterial verification and inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"b1mq9g\" data-start=\"3660\" data-end=\"3698\"\u003e\n\u003cp data-start=\"3662\" data-end=\"3698\"\u003eChemical and pharmaceutical weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ebh4a\" data-start=\"3699\" data-end=\"3736\"\u003e\n\u003cp data-start=\"3701\" data-end=\"3736\"\u003eEducational laboratory environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3738\" data-end=\"3741\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3743\" data-end=\"3769\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3771\" data-end=\"3779\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3780\" data-end=\"3795\"\u003e\u003cstrong data-start=\"3780\" data-end=\"3795\"\u003eWLC-60-C2-R\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3797\" data-end=\"3825\"\u003ePart Number: \u003cstrong data-start=\"3810\" data-end=\"3825\"\u003eWL-206-0063\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3827\" data-end=\"3830\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"3832\" data-end=\"3851\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"3853\" data-end=\"3882\"\u003eMaximum capacity:\u003cbr data-start=\"3870\" data-end=\"3873\"\u003e\u003cstrong data-start=\"3873\" data-end=\"3882\"\u003e60 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3884\" data-end=\"3908\"\u003eMinimum load:\u003cbr data-start=\"3897\" data-end=\"3900\"\u003e\u003cstrong data-start=\"3900\" data-end=\"3908\"\u003e50 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3910\" data-end=\"3932\"\u003eReadability:\u003cbr data-start=\"3922\" data-end=\"3925\"\u003e\u003cstrong data-start=\"3925\" data-end=\"3932\"\u003e1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3934\" data-end=\"3958\"\u003eTare range:\u003cbr data-start=\"3945\" data-end=\"3948\"\u003e\u003cstrong data-start=\"3948\" data-end=\"3958\"\u003e-60 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3960\" data-end=\"3963\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"3965\" data-end=\"3975\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"3977\" data-end=\"4001\"\u003eRepeatability:\u003cbr data-start=\"3991\" data-end=\"3994\"\u003e\u003cstrong data-start=\"3994\" data-end=\"4001\"\u003e1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4003\" data-end=\"4024\"\u003eLinearity:\u003cbr data-start=\"4013\" data-end=\"4016\"\u003e\u003cstrong data-start=\"4016\" data-end=\"4024\"\u003e±2 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4026\" data-end=\"4061\"\u003eStabilization time:\u003cbr data-start=\"4045\" data-end=\"4048\"\u003e\u003cstrong data-start=\"4048\" data-end=\"4061\"\u003e3 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4063\" data-end=\"4066\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4068\" data-end=\"4077\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4079\" data-end=\"4102\"\u003e\u003cstrong data-start=\"4079\" data-end=\"4102\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4104\" data-end=\"4107\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4109\" data-end=\"4128\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4130\" data-end=\"4161\"\u003eMaterial:\u003cbr data-start=\"4139\" data-end=\"4142\"\u003e\u003cstrong data-start=\"4142\" data-end=\"4161\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4163\" data-end=\"4199\"\u003eDimensions:\u003cbr data-start=\"4174\" data-end=\"4177\"\u003e\u003cstrong data-start=\"4177\" data-end=\"4199\"\u003e15.7 × 19.7 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4201\" data-end=\"4204\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4206\" data-end=\"4220\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4222\" data-end=\"4241\"\u003eStandard interface:\u003c\/p\u003e\n\u003cul data-start=\"4243\" data-end=\"4254\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"4243\" data-end=\"4254\"\u003e\n\u003cp data-start=\"4245\" data-end=\"4254\"\u003e\u003cstrong data-start=\"4245\" data-end=\"4254\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4256\" data-end=\"4275\"\u003eOptional interface:\u003c\/p\u003e\n\u003cul data-start=\"4277\" data-end=\"4288\"\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"4277\" data-end=\"4288\"\u003e\n\u003cp data-start=\"4279\" data-end=\"4288\"\u003e\u003cstrong data-start=\"4279\" data-end=\"4288\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4290\" data-end=\"4339\"\u003eOptional additional \u003cstrong data-start=\"4310\" data-end=\"4339\"\u003eRS232 connector available\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4341\" data-end=\"4344\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4346\" data-end=\"4366\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4368\" data-end=\"4381\"\u003ePower supply:\u003c\/p\u003e\n\u003cp data-start=\"4383\" data-end=\"4408\"\u003e\u003cstrong data-start=\"4383\" data-end=\"4408\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4410\" data-end=\"4418\"\u003eBattery:\u003c\/p\u003e\n\u003cp data-start=\"4420\" data-end=\"4457\"\u003e\u003cstrong data-start=\"4420\" data-end=\"4457\"\u003eInternal sealed lead-acid battery\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4459\" data-end=\"4482\"\u003eBattery operating time:\u003c\/p\u003e\n\u003cp data-start=\"4484\" data-end=\"4504\"\u003e\u003cstrong data-start=\"4484\" data-end=\"4504\"\u003eApprox. 10 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4506\" data-end=\"4509\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4511\" data-end=\"4537\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4539\" data-end=\"4561\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4563\" data-end=\"4578\"\u003e\u003cstrong data-start=\"4563\" data-end=\"4578\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4580\" data-end=\"4598\"\u003eRelative humidity:\u003c\/p\u003e\n\u003cp data-start=\"4600\" data-end=\"4633\"\u003e\u003cstrong data-start=\"4600\" data-end=\"4633\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4635\" data-end=\"4638\"\u003e\n\u003ch1 data-section-id=\"1tt54le\" data-start=\"4640\" data-end=\"4659\"\u003eProtection Rating\u003c\/h1\u003e\n\u003cp data-start=\"4661\" data-end=\"4669\"\u003e\u003cstrong data-start=\"4661\" data-end=\"4669\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4671\" data-end=\"4674\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4676\" data-end=\"4697\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4699\" data-end=\"4718\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4720\" data-end=\"4744\"\u003e\u003cstrong data-start=\"4720\" data-end=\"4744\"\u003e28 × 23 × 8.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4746\" data-end=\"4758\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"4760\" data-end=\"4772\"\u003e\u003cstrong data-start=\"4760\" data-end=\"4772\"\u003e27.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4774\" data-end=\"4790\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"4792\" data-end=\"4802\"\u003e\u003cstrong data-start=\"4792\" data-end=\"4802\"\u003e33 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4804\" data-end=\"4807\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"4809\" data-end=\"4824\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"4826\" data-end=\"4859\"\u003e\u003cstrong data-start=\"4826\" data-end=\"4845\"\u003eNTEP Certified:\u003c\/strong\u003e Not available\u003c\/p\u003e\n\u003chr data-start=\"4861\" data-end=\"4864\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"4866\" data-end=\"4876\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"4878\" data-end=\"4910\"\u003e\u003cstrong data-start=\"4878\" data-end=\"4910\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282551730498,"sku":null,"price":1122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/precision-balance-wlc-r_wlc-60c2r--wl-206-0063-_1_3913fd0d-9574-4a50-a55d-84be243e5f46.jpg?v=1773587849"},{"product_id":"across-international-ps-1000-r2-radwag-1000g-capacity-0-001g-readability-5x5-precision-balance","title":"Across International PS 1000.R2 Radwag 1000g Capacity 0.001g Readability 5x5\" Precision Balance","description":"\u003ch2 data-section-id=\"178hp1o\" data-start=\"411\" data-end=\"502\"\u003eHigh-Precision Laboratory Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"504\" data-end=\"719\"\u003eThe \u003cstrong data-start=\"508\" data-end=\"547\"\u003eRadwag RS 1000.R2 Precision Balance\u003c\/strong\u003e from the \u003cstrong data-start=\"557\" data-end=\"573\"\u003ePS.R2 series\u003c\/strong\u003e represents a new generation of precision laboratory balances designed for \u003cstrong data-start=\"648\" data-end=\"718\"\u003ehigh-accuracy weighing, data management, and laboratory automation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"721\" data-end=\"963\"\u003eWith a \u003cstrong data-start=\"728\" data-end=\"778\"\u003e1000 g capacity and 0.001 g (1 mg) readability\u003c\/strong\u003e, the RS 1000.R2 delivers precise mass measurements for laboratory applications including \u003cstrong data-start=\"868\" data-end=\"962\"\u003epharmaceutical analysis, chemical research, quality control, and industrial weighing tasks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"965\" data-end=\"1151\"\u003eThe balance features \u003cstrong data-start=\"986\" data-end=\"1019\"\u003eautomatic internal adjustment\u003c\/strong\u003e, which continuously compensates for temperature fluctuations and time-related changes to ensure accurate and reliable measurements.\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1365\"\u003eEquipped with a \u003cstrong data-start=\"1169\" data-end=\"1225\"\u003ebacklit LCD display with additional information line\u003c\/strong\u003e, the system allows users to display important data such as \u003cstrong data-start=\"1285\" data-end=\"1341\"\u003eproduct names, tare values, and operational messages\u003c\/strong\u003e directly on the screen.\u003c\/p\u003e\n\u003cp data-start=\"1367\" data-end=\"1551\"\u003eWith \u003cstrong data-start=\"1372\" data-end=\"1459\"\u003emultiple communication interfaces including RS232, USB-A, USB-B, and optional Wi-Fi\u003c\/strong\u003e, the RS 1000.R2 easily integrates with laboratory software, computers, and network systems.\u003c\/p\u003e\n\u003chr data-start=\"1553\" data-end=\"1556\"\u003e\n\u003ch1 data-section-id=\"lqxm4e\" data-start=\"1558\" data-end=\"1615\"\u003eKey Features of the Radwag RS 1000.R2 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"6gfpsk\" data-start=\"1617\" data-end=\"1647\"\u003eHigh Precision Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1648\" data-end=\"1781\"\u003eDelivers \u003cstrong data-start=\"1657\" data-end=\"1687\"\u003e0.001 g readability (1 mg)\u003c\/strong\u003e with \u003cstrong data-start=\"1693\" data-end=\"1720\"\u003e1000 g maximum capacity\u003c\/strong\u003e, providing excellent accuracy for laboratory weighing tasks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qxdg43\" data-start=\"1783\" data-end=\"1816\"\u003eAutomatic Internal Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"1817\" data-end=\"1949\"\u003eThe internal calibration system compensates for \u003cstrong data-start=\"1865\" data-end=\"1903\"\u003etemperature changes and time drift\u003c\/strong\u003e, maintaining consistent measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ovztu1\" data-start=\"1951\" data-end=\"1975\"\u003eAdvanced LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1976\" data-end=\"2056\"\u003eLarge \u003cstrong data-start=\"1982\" data-end=\"2037\"\u003ebacklit LCD screen with additional information line\u003c\/strong\u003e allows display of:\u003c\/p\u003e\n\u003cul data-start=\"2058\" data-end=\"2132\"\u003e\n\u003cli data-section-id=\"82fg7r\" data-start=\"2058\" data-end=\"2073\"\u003e\n\u003cp data-start=\"2060\" data-end=\"2073\"\u003eProduct names\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p3jhea\" data-start=\"2074\" data-end=\"2087\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2087\"\u003eTare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lid7ns\" data-start=\"2088\" data-end=\"2110\"\u003e\n\u003cp data-start=\"2090\" data-end=\"2110\"\u003eOperational messages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1acayfs\" data-start=\"2111\" data-end=\"2132\"\u003e\n\u003cp data-start=\"2113\" data-end=\"2132\"\u003eMeasurement results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"savnnm\" data-start=\"2134\" data-end=\"2166\"\u003eMulti-Interface Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2167\" data-end=\"2209\"\u003eBuilt-in communication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2211\" data-end=\"2281\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2211\" data-end=\"2226\"\u003e\n\u003cp data-start=\"2213\" data-end=\"2226\"\u003e\u003cstrong data-start=\"2213\" data-end=\"2226\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2227\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2229\" data-end=\"2243\"\u003e\u003cstrong data-start=\"2229\" data-end=\"2243\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2244\" data-end=\"2260\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2260\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2260\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"2261\" data-end=\"2281\"\u003e\n\u003cp data-start=\"2263\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2263\" data-end=\"2281\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2283\" data-end=\"2377\"\u003eThese allow seamless integration with computers, printers, and laboratory information systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"186nltk\" data-start=\"2379\" data-end=\"2412\"\u003eUnder-Pan Weighing Capability\u003c\/h3\u003e\n\u003cp data-start=\"2413\" data-end=\"2526\"\u003eSupports \u003cstrong data-start=\"2422\" data-end=\"2444\"\u003eunder-pan weighing\u003c\/strong\u003e, allowing samples to be suspended below the balance for specialized measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rynjla\" data-start=\"2528\" data-end=\"2560\"\u003eStainless Steel Weighing Pan\u003c\/h3\u003e\n\u003cp data-start=\"2561\" data-end=\"2661\"\u003eDurable \u003cstrong data-start=\"2569\" data-end=\"2606\"\u003estainless steel weighing platform\u003c\/strong\u003e ensures corrosion resistance and long-term durability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"692exr\" data-start=\"2663\" data-end=\"2690\"\u003eDraft Shield Protection\u003c\/h3\u003e\n\u003cp data-start=\"2691\" data-end=\"2795\"\u003eBalances with smaller pans include a \u003cstrong data-start=\"2728\" data-end=\"2744\"\u003edraft shield\u003c\/strong\u003e to protect measurements from airflow disturbances.\u003c\/p\u003e\n\u003chr data-start=\"2797\" data-end=\"2800\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"2802\" data-end=\"2837\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"2839\" data-end=\"3008\"\u003eThe PS.R2 balance series includes an advanced \u003cstrong data-start=\"2885\" data-end=\"2940\"\u003edata management system with five internal databases\u003c\/strong\u003e, enabling efficient organization and traceability of weighing data.\u003c\/p\u003e\n\u003ch3 data-section-id=\"x21cix\" data-start=\"3010\" data-end=\"3033\"\u003eAvailable Databases\u003c\/h3\u003e\n\u003cp data-start=\"3035\" data-end=\"3088\"\u003eThe system can store data in five internal databases:\u003c\/p\u003e\n\u003cul data-start=\"3090\" data-end=\"3282\"\u003e\n\u003cli data-section-id=\"biapsd\" data-start=\"3090\" data-end=\"3117\"\u003e\n\u003cp data-start=\"3092\" data-end=\"3117\"\u003e\u003cstrong data-start=\"3092\" data-end=\"3102\"\u003eUsers:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6qakdp\" data-start=\"3118\" data-end=\"3153\"\u003e\n\u003cp data-start=\"3120\" data-end=\"3153\"\u003e\u003cstrong data-start=\"3120\" data-end=\"3133\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bc5kud\" data-start=\"3154\" data-end=\"3195\"\u003e\n\u003cp data-start=\"3156\" data-end=\"3195\"\u003e\u003cstrong data-start=\"3156\" data-end=\"3171\"\u003eWeighments:\u003c\/strong\u003e up to 5000 measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nh3aza\" data-start=\"3196\" data-end=\"3230\"\u003e\n\u003cp data-start=\"3198\" data-end=\"3230\"\u003e\u003cstrong data-start=\"3198\" data-end=\"3208\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g1mdbr\" data-start=\"3231\" data-end=\"3282\"\u003e\n\u003cp data-start=\"3233\" data-end=\"3282\"\u003e\u003cstrong data-start=\"3233\" data-end=\"3250\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighment records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"rz7j0t\" data-start=\"3284\" data-end=\"3307\"\u003eALIBI Memory System\u003c\/h3\u003e\n\u003cp data-start=\"3309\" data-end=\"3507\"\u003eThe integrated \u003cstrong data-start=\"3324\" data-end=\"3340\"\u003eALIBI memory\u003c\/strong\u003e stores up to \u003cstrong data-start=\"3354\" data-end=\"3383\"\u003e100,000 weighment records\u003c\/strong\u003e in a secure, tamper-proof data area, ensuring reliable record keeping for long-term traceability and regulatory compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b24h3h\" data-start=\"3509\" data-end=\"3537\"\u003eUSB Data Import \u0026amp; Export\u003c\/h3\u003e\n\u003cp data-start=\"3539\" data-end=\"3645\"\u003eDatabases can be \u003cstrong data-start=\"3556\" data-end=\"3603\"\u003eimported or exported using USB flash drives\u003c\/strong\u003e, enabling quick data transfer and backup.\u003c\/p\u003e\n\u003chr data-start=\"3647\" data-end=\"3650\"\u003e\n\u003ch1 data-section-id=\"cgez46\" data-start=\"3652\" data-end=\"3678\"\u003eEasy Access to Functions\u003c\/h1\u003e\n\u003cp data-start=\"3680\" data-end=\"3810\"\u003eThe balance features \u003cstrong data-start=\"3701\" data-end=\"3760\"\u003equick navigation keys and programmable function buttons\u003c\/strong\u003e, providing fast access to commonly used features.\u003c\/p\u003e\n\u003cul data-start=\"3812\" data-end=\"3924\"\u003e\n\u003cli data-section-id=\"su8a6k\" data-start=\"3812\" data-end=\"3844\"\u003e\n\u003cp data-start=\"3814\" data-end=\"3844\"\u003eDirect access to \u003cstrong data-start=\"3831\" data-end=\"3844\"\u003edatabases\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4se1al\" data-start=\"3845\" data-end=\"3885\"\u003e\n\u003cp data-start=\"3847\" data-end=\"3885\"\u003eDirect access to \u003cstrong data-start=\"3864\" data-end=\"3885\"\u003ebalance functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iia02z\" data-start=\"3886\" data-end=\"3924\"\u003e\n\u003cp data-start=\"3888\" data-end=\"3924\"\u003e\u003cstrong data-start=\"3888\" data-end=\"3924\"\u003eF1–F4 programmable function keys\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3926\" data-end=\"3929\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3931\" data-end=\"3951\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3953\" data-end=\"4013\"\u003eThe Radwag RS 1000.R2 precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"4015\" data-end=\"4183\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"4015\" data-end=\"4044\"\u003e\n\u003cp data-start=\"4017\" data-end=\"4044\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nbcj6d\" data-start=\"4045\" data-end=\"4064\"\u003e\n\u003cp data-start=\"4047\" data-end=\"4064\"\u003eChemical research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tnvors\" data-start=\"4065\" data-end=\"4088\"\u003e\n\u003cp data-start=\"4067\" data-end=\"4088\"\u003eAcademic laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"apgb38\" data-start=\"4089\" data-end=\"4119\"\u003e\n\u003cp data-start=\"4091\" data-end=\"4119\"\u003eQuality control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m7dh3m\" data-start=\"4120\" data-end=\"4151\"\u003e\n\u003cp data-start=\"4122\" data-end=\"4151\"\u003eMaterial science laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cqen8a\" data-start=\"4152\" data-end=\"4183\"\u003e\n\u003cp data-start=\"4154\" data-end=\"4183\"\u003eIndustrial testing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4185\" data-end=\"4188\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4190\" data-end=\"4216\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4218\" data-end=\"4226\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4227\" data-end=\"4241\"\u003e\u003cstrong data-start=\"4227\" data-end=\"4241\"\u003eRS 1000.R2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4243\" data-end=\"4271\"\u003ePart Number: \u003cstrong data-start=\"4256\" data-end=\"4271\"\u003eWL-212-0022\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4273\" data-end=\"4276\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"4278\" data-end=\"4297\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"4299\" data-end=\"4329\"\u003eMaximum capacity:\u003cbr data-start=\"4316\" data-end=\"4319\"\u003e\u003cstrong data-start=\"4319\" data-end=\"4329\"\u003e1000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4331\" data-end=\"4356\"\u003eMinimum load:\u003cbr data-start=\"4344\" data-end=\"4347\"\u003e\u003cstrong data-start=\"4347\" data-end=\"4356\"\u003e20 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4358\" data-end=\"4384\"\u003eReadability:\u003cbr data-start=\"4370\" data-end=\"4373\"\u003e\u003cstrong data-start=\"4373\" data-end=\"4384\"\u003e0.001 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4386\" data-end=\"4411\"\u003eTare range:\u003cbr data-start=\"4397\" data-end=\"4400\"\u003e\u003cstrong data-start=\"4400\" data-end=\"4411\"\u003e-1000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4413\" data-end=\"4416\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4418\" data-end=\"4428\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4430\" data-end=\"4465\"\u003eRepeatability (Max):\u003cbr data-start=\"4450\" data-end=\"4453\"\u003e\u003cstrong data-start=\"4453\" data-end=\"4465\"\u003e0.0015 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4467\" data-end=\"4505\"\u003eRepeatability (5% Max):\u003cbr data-start=\"4490\" data-end=\"4493\"\u003e\u003cstrong data-start=\"4493\" data-end=\"4505\"\u003e0.0005 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4507\" data-end=\"4532\"\u003eLinearity:\u003cbr data-start=\"4517\" data-end=\"4520\"\u003e\u003cstrong data-start=\"4520\" data-end=\"4532\"\u003e±0.003 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4534\" data-end=\"4569\"\u003eStabilization time:\u003cbr data-start=\"4553\" data-end=\"4556\"\u003e\u003cstrong data-start=\"4556\" data-end=\"4569\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4571\" data-end=\"4574\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4576\" data-end=\"4585\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4587\" data-end=\"4632\"\u003e\u003cstrong data-start=\"4587\" data-end=\"4632\"\u003eBacklit LCD display with information line\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4634\" data-end=\"4637\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4639\" data-end=\"4658\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4660\" data-end=\"4675\"\u003ePan dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4677\" data-end=\"4708\"\u003e\u003cstrong data-start=\"4677\" data-end=\"4708\"\u003e5 × 5 inches (128 × 128 mm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4710\" data-end=\"4719\"\u003eMaterial:\u003c\/p\u003e\n\u003cp data-start=\"4721\" data-end=\"4740\"\u003e\u003cstrong data-start=\"4721\" data-end=\"4740\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4742\" data-end=\"4745\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4747\" data-end=\"4761\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4763\" data-end=\"4788\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4790\" data-end=\"4850\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4790\" data-end=\"4805\"\u003e\n\u003cp data-start=\"4792\" data-end=\"4805\"\u003e\u003cstrong data-start=\"4792\" data-end=\"4805\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4806\" data-end=\"4817\"\u003e\n\u003cp data-start=\"4808\" data-end=\"4817\"\u003e\u003cstrong data-start=\"4808\" data-end=\"4817\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4818\" data-end=\"4829\"\u003e\n\u003cp data-start=\"4820\" data-end=\"4829\"\u003e\u003cstrong data-start=\"4820\" data-end=\"4829\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4830\" data-end=\"4850\"\u003e\n\u003cp data-start=\"4832\" data-end=\"4850\"\u003e\u003cstrong data-start=\"4832\" data-end=\"4850\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4852\" data-end=\"4855\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4857\" data-end=\"4877\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4879\" data-end=\"4904\"\u003e\u003cstrong data-start=\"4879\" data-end=\"4904\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4906\" data-end=\"4909\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"4911\" data-end=\"4933\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4935\" data-end=\"4957\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4959\" data-end=\"4974\"\u003e\u003cstrong data-start=\"4959\" data-end=\"4974\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4976\" data-end=\"4994\"\u003eRelative humidity:\u003c\/p\u003e\n\u003cp data-start=\"4996\" data-end=\"5029\"\u003e\u003cstrong data-start=\"4996\" data-end=\"5029\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5031\" data-end=\"5034\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5036\" data-end=\"5057\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5059\" data-end=\"5078\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"5080\" data-end=\"5105\"\u003e\u003cstrong data-start=\"5080\" data-end=\"5105\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5107\" data-end=\"5119\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"5121\" data-end=\"5132\"\u003e\u003cstrong data-start=\"5121\" data-end=\"5132\"\u003e8.6 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5134\" data-end=\"5150\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"5152\" data-end=\"5162\"\u003e\u003cstrong data-start=\"5152\" data-end=\"5162\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5164\" data-end=\"5167\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"5169\" data-end=\"5184\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"5186\" data-end=\"5204\"\u003e\u003cstrong data-start=\"5186\" data-end=\"5204\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5206\" data-end=\"5209\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5211\" data-end=\"5232\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5234\" data-end=\"5456\"\u003e\n\u003cli data-section-id=\"6j1aky\" data-start=\"5234\" data-end=\"5275\"\u003e\n\u003cp data-start=\"5236\" data-end=\"5275\"\u003eRadwag RS 1000.R2 Precision Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qb4yqq\" data-start=\"5276\" data-end=\"5310\"\u003e\n\u003cp data-start=\"5278\" data-end=\"5310\"\u003eStainless Steel Weighing Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kofcw1\" data-start=\"5311\" data-end=\"5328\"\u003e\n\u003cp data-start=\"5313\" data-end=\"5328\"\u003eWind Shield – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hio71s\" data-start=\"5329\" data-end=\"5347\"\u003e\n\u003cp data-start=\"5331\" data-end=\"5347\"\u003eDraft Shield – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"299y06\" data-start=\"5348\" data-end=\"5384\"\u003e\n\u003cp data-start=\"5350\" data-end=\"5384\"\u003eGrounding Foot (Spring Center) – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xyedi2\" data-start=\"5385\" data-end=\"5395\"\u003e\n\u003cp data-start=\"5387\" data-end=\"5395\"\u003eFeet – 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nfnlhe\" data-start=\"5396\" data-end=\"5415\"\u003e\n\u003cp data-start=\"5398\" data-end=\"5415\"\u003ePower Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"yvpyh1\" data-start=\"5416\" data-end=\"5435\"\u003e\n\u003cp data-start=\"5418\" data-end=\"5435\"\u003ePlug Adapters – 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w7k5o8\" data-start=\"5436\" data-end=\"5456\"\u003e\n\u003cp data-start=\"5438\" data-end=\"5456\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5458\" data-end=\"5461\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5463\" data-end=\"5473\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5475\" data-end=\"5507\"\u003e\u003cstrong data-start=\"5475\" data-end=\"5507\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5509\" data-end=\"5512\"\u003e\n\u003ch1 data-section-id=\"1wnlmxt\" data-start=\"5514\" data-end=\"5525\"\u003eDownloads\u003c\/h1\u003e\n\u003cul data-start=\"5527\" data-end=\"5596\"\u003e\n\u003cli data-section-id=\"10sdtyb\" data-start=\"5527\" data-end=\"5540\"\u003e\n\u003cp data-start=\"5529\" data-end=\"5540\"\u003eUser Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pz8bpx\" data-start=\"5541\" data-end=\"5559\"\u003e\n\u003cp data-start=\"5543\" data-end=\"5559\"\u003eProduct Brochure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"oi2zwy\" data-start=\"5560\" data-end=\"5572\"\u003e\n\u003cp data-start=\"5562\" data-end=\"5572\"\u003eUSB Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18bkez1\" data-start=\"5573\" data-end=\"5596\"\u003e\n\u003cp data-start=\"5575\" data-end=\"5596\"\u003eALIBI Reader Software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282557104450,"sku":null,"price":1478.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ps-r1_ps-1000-r2--wl-212-0022-_1.jpg?v=1773588051"},{"product_id":"across-international-as-220-r2-plus-radwag-220g-capacity-0-1mg-readability-o4-analytical-balance","title":"Across International AS 220.R2 PLUS Radwag 220g Capacity 0.1mg Readability ø4\" Analytical Balance","description":"\u003ch2 data-section-id=\"t1oao7\" data-start=\"375\" data-end=\"466\"\u003eHigh-Precision Analytical Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"468\" data-end=\"877\"\u003eThe \u003cstrong data-start=\"472\" data-end=\"516\"\u003eRadwag AS 220.R2 PLUS Analytical Balance\u003c\/strong\u003e is a high-precision laboratory weighing instrument designed for \u003cstrong data-start=\"581\" data-end=\"672\"\u003eaccurate analytical measurements in pharmaceutical, chemical, and research laboratories\u003c\/strong\u003e. Part of the \u003cstrong data-start=\"686\" data-end=\"706\"\u003eSYNERGY LAB line\u003c\/strong\u003e, the AS R2 PLUS series combines advanced mechanical design with intelligent data management features to deliver exceptional reliability, precision, and ease of operation.\u003c\/p\u003e\n\u003cp data-start=\"879\" data-end=\"1221\"\u003eWith a \u003cstrong data-start=\"886\" data-end=\"935\"\u003e220 g maximum capacity and 0.1 mg readability\u003c\/strong\u003e, this analytical balance ensures extremely accurate measurements while maintaining fast stabilization times. The spacious \u003cstrong data-start=\"1058\" data-end=\"1109\"\u003eweighing chamber and ergonomic open-door design\u003c\/strong\u003e allow convenient access to the weighing pan, making it easy to work with laboratory glassware of various sizes.\u003c\/p\u003e\n\u003cp data-start=\"1223\" data-end=\"1424\"\u003eThe balance includes \u003cstrong data-start=\"1244\" data-end=\"1277\"\u003eautomatic internal adjustment\u003c\/strong\u003e, which compensates for temperature changes and time drift to maintain consistent measurement accuracy even in challenging laboratory environments.\u003c\/p\u003e\n\u003cp data-start=\"1426\" data-end=\"1628\"\u003eMultiple communication interfaces—including \u003cstrong data-start=\"1470\" data-end=\"1523\"\u003eRS232, USB-A, USB-B, Ethernet, and optional Wi-Fi\u003c\/strong\u003e—allow seamless integration with computers, laboratory information systems, and data management software.\u003c\/p\u003e\n\u003chr data-start=\"1630\" data-end=\"1633\"\u003e\n\u003ch1 data-section-id=\"rz21k\" data-start=\"1635\" data-end=\"1697\"\u003eKey Features of the Radwag AS 220.R2 PLUS Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"nn2xxg\" data-start=\"1699\" data-end=\"1728\"\u003eUltra-Precise Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1729\" data-end=\"1830\"\u003eProvides \u003cstrong data-start=\"1738\" data-end=\"1780\"\u003e0.1 mg readability with 220 g capacity\u003c\/strong\u003e, ideal for high-accuracy laboratory measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11yfrj5\" data-start=\"1832\" data-end=\"1861\"\u003eSpacious Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"1862\" data-end=\"1975\"\u003eThe large weighing chamber and wide door opening allow easy access and convenient handling of laboratory vessels.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qxdg43\" data-start=\"1977\" data-end=\"2010\"\u003eAutomatic Internal Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"2011\" data-end=\"2141\"\u003eAn advanced \u003cstrong data-start=\"2023\" data-end=\"2054\"\u003einternal calibration system\u003c\/strong\u003e automatically adjusts the balance to maintain precision despite environmental changes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kevx82\" data-start=\"2143\" data-end=\"2172\"\u003eAnti-Static Glass Coating\u003c\/h3\u003e\n\u003cp data-start=\"2173\" data-end=\"2287\"\u003eSpecial \u003cstrong data-start=\"2181\" data-end=\"2208\"\u003eantistatic pane coating\u003c\/strong\u003e reduces electrostatic influence on measurements, improving weighing stability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gf5gh2\" data-start=\"2289\" data-end=\"2320\"\u003eErgonomic Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"2321\" data-end=\"2472\"\u003eA new \u003cstrong data-start=\"2327\" data-end=\"2357\"\u003ealuminum base construction\u003c\/strong\u003e enhances stability while the \u003cstrong data-start=\"2387\" data-end=\"2408\"\u003eDual-CLICK system\u003c\/strong\u003e allows tool-free assembly and cleaning of the weighing chamber.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3o394\" data-start=\"2474\" data-end=\"2500\"\u003eFront Levelling System\u003c\/h3\u003e\n\u003cp data-start=\"2501\" data-end=\"2624\"\u003eA simplified \u003cstrong data-start=\"2514\" data-end=\"2543\"\u003etwo-point leveling system\u003c\/strong\u003e located at the front of the weighing chamber allows quick and accurate leveling.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1i6cb4v\" data-start=\"2626\" data-end=\"2649\"\u003eSecure ALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"2650\" data-end=\"2788\"\u003eThe integrated \u003cstrong data-start=\"2665\" data-end=\"2721\"\u003eALIBI memory system records up to 100,000 weighments\u003c\/strong\u003e, ensuring secure long-term data storage for regulatory compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"2790\" data-end=\"2815\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2816\" data-end=\"2849\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2851\" data-end=\"2926\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2851\" data-end=\"2866\"\u003e\n\u003cp data-start=\"2853\" data-end=\"2866\"\u003e\u003cstrong data-start=\"2853\" data-end=\"2866\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"2867\" data-end=\"2878\"\u003e\n\u003cp data-start=\"2869\" data-end=\"2878\"\u003e\u003cstrong data-start=\"2869\" data-end=\"2878\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"2879\" data-end=\"2890\"\u003e\n\u003cp data-start=\"2881\" data-end=\"2890\"\u003e\u003cstrong data-start=\"2881\" data-end=\"2890\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"2891\" data-end=\"2905\"\u003e\n\u003cp data-start=\"2893\" data-end=\"2905\"\u003e\u003cstrong data-start=\"2893\" data-end=\"2905\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"2906\" data-end=\"2926\"\u003e\n\u003cp data-start=\"2908\" data-end=\"2926\"\u003e\u003cstrong data-start=\"2908\" data-end=\"2926\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2928\" data-end=\"3006\"\u003eA front USB port allows quick connection to flash drives and external devices.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tqvlp\" data-start=\"3008\" data-end=\"3036\"\u003eKensington Lock Security\u003c\/h3\u003e\n\u003cp data-start=\"3037\" data-end=\"3125\"\u003eThe balance includes a \u003cstrong data-start=\"3060\" data-end=\"3084\"\u003eKensington lock slot\u003c\/strong\u003e to protect the instrument against theft.\u003c\/p\u003e\n\u003chr data-start=\"3127\" data-end=\"3130\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"3132\" data-end=\"3167\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"3169\" data-end=\"3253\"\u003eThe AS R2 PLUS series includes an advanced internal data system with five databases.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"3255\" data-end=\"3276\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"3278\" data-end=\"3483\"\u003e\n\u003cli data-section-id=\"117fjp8\" data-start=\"3278\" data-end=\"3311\"\u003e\n\u003cp data-start=\"3280\" data-end=\"3311\"\u003e\u003cstrong data-start=\"3280\" data-end=\"3294\"\u003eOperators:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d70vn1\" data-start=\"3312\" data-end=\"3349\"\u003e\n\u003cp data-start=\"3314\" data-end=\"3349\"\u003e\u003cstrong data-start=\"3314\" data-end=\"3327\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lznc7r\" data-start=\"3350\" data-end=\"3392\"\u003e\n\u003cp data-start=\"3352\" data-end=\"3392\"\u003e\u003cstrong data-start=\"3352\" data-end=\"3366\"\u003eWeighings:\u003c\/strong\u003e up to 5000 measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"3393\" data-end=\"3429\"\u003e\n\u003cp data-start=\"3395\" data-end=\"3429\"\u003e\u003cstrong data-start=\"3395\" data-end=\"3405\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1texeyf\" data-start=\"3430\" data-end=\"3483\"\u003e\n\u003cp data-start=\"3432\" data-end=\"3483\"\u003e\u003cstrong data-start=\"3432\" data-end=\"3449\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighment records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3485\" data-end=\"3598\"\u003eThis system enables multiple users to work with multiple product databases while maintaining secure traceability.\u003c\/p\u003e\n\u003chr data-start=\"3600\" data-end=\"3603\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3605\" data-end=\"3634\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"3636\" data-end=\"3725\"\u003eThe AS R2 PLUS analytical balance supports a wide range of laboratory weighing functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"3727\" data-end=\"3739\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"3740\" data-end=\"3866\"\u003eAutomatic diagnostic function that verifies \u003cstrong data-start=\"3784\" data-end=\"3833\"\u003emetrological parameters such as repeatability\u003c\/strong\u003e under real operating conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"3868\" data-end=\"3878\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"3879\" data-end=\"4011\"\u003ePrecise dosing function using a \u003cstrong data-start=\"3911\" data-end=\"3949\"\u003ereference mass and tolerance range\u003c\/strong\u003e, ideal for weighing powders, liquids, and granular materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4013\" data-end=\"4033\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4034\" data-end=\"4119\"\u003eCompares sample weight to a reference value (100%) to determine percentage deviation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"4121\" data-end=\"4135\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"4136\" data-end=\"4212\"\u003eAdds multiple weighing results together to determine total mass of mixtures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4214\" data-end=\"4232\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4233\" data-end=\"4340\"\u003eCounts items based on total weight and known individual unit weight with \u003cstrong data-start=\"4306\" data-end=\"4339\"\u003eautomatic accuracy correction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"4342\" data-end=\"4355\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"4356\" data-end=\"4430\"\u003eCaptures and holds the highest weight reading during dynamic measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u90ctf\" data-start=\"4432\" data-end=\"4446\"\u003eStatistics\u003c\/h3\u003e\n\u003cp data-start=\"4447\" data-end=\"4503\"\u003eProvides statistical analysis of measurements including:\u003c\/p\u003e\n\u003cul data-start=\"4505\" data-end=\"4601\"\u003e\n\u003cli data-section-id=\"1tpje4l\" data-start=\"4505\" data-end=\"4533\"\u003e\n\u003cp data-start=\"4507\" data-end=\"4533\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s9zm9s\" data-start=\"4534\" data-end=\"4549\"\u003e\n\u003cp data-start=\"4536\" data-end=\"4549\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvyhm8\" data-start=\"4550\" data-end=\"4570\"\u003e\n\u003cp data-start=\"4552\" data-end=\"4570\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwk9jh\" data-start=\"4571\" data-end=\"4581\"\u003e\n\u003cp data-start=\"4573\" data-end=\"4581\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xk4t9\" data-start=\"4582\" data-end=\"4601\"\u003e\n\u003cp data-start=\"4584\" data-end=\"4601\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4603\" data-end=\"4620\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4621\" data-end=\"4726\"\u003eAllows verification of whether sample mass falls within predefined \u003cstrong data-start=\"4688\" data-end=\"4725\"\u003eLOW (LO) and HIGH (HI) thresholds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"4728\" data-end=\"4750\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4751\" data-end=\"4817\"\u003eSupports suspended weighing for \u003cstrong data-start=\"4783\" data-end=\"4816\"\u003enon-standard or large objects\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"4819\" data-end=\"4838\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4839\" data-end=\"4926\"\u003eDetermines mass of moving samples by averaging measurements over a defined time period.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7ulzqj\" data-start=\"4928\" data-end=\"4953\"\u003eDensity Determination\u003c\/h3\u003e\n\u003cp data-start=\"4954\" data-end=\"5061\"\u003eAllows measurement of \u003cstrong data-start=\"4976\" data-end=\"5031\"\u003esolid or liquid density using Archimedes’ principle\u003c\/strong\u003e with an optional density kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kvw8o3\" data-start=\"5063\" data-end=\"5081\"\u003eGLP Procedures\u003c\/h3\u003e\n\u003cp data-start=\"5082\" data-end=\"5168\"\u003eAutomatically generates \u003cstrong data-start=\"5106\" data-end=\"5167\"\u003eGood Laboratory Practice (GLP) compliant weighing reports\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5170\" data-end=\"5173\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5175\" data-end=\"5195\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5197\" data-end=\"5262\"\u003eThe Radwag AS 220.R2 PLUS analytical balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5264\" data-end=\"5437\"\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"5264\" data-end=\"5293\"\u003e\n\u003cp data-start=\"5266\" data-end=\"5293\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q12ni6\" data-start=\"5294\" data-end=\"5313\"\u003e\n\u003cp data-start=\"5296\" data-end=\"5313\"\u003eChemical analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iigjch\" data-start=\"5314\" data-end=\"5346\"\u003e\n\u003cp data-start=\"5316\" data-end=\"5346\"\u003eAcademic research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ilif90\" data-start=\"5347\" data-end=\"5372\"\u003e\n\u003cp data-start=\"5349\" data-end=\"5372\"\u003eQuality control testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"196xs9a\" data-start=\"5373\" data-end=\"5400\"\u003e\n\u003cp data-start=\"5375\" data-end=\"5400\"\u003eMaterial science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t7a66i\" data-start=\"5401\" data-end=\"5437\"\u003e\n\u003cp data-start=\"5403\" data-end=\"5437\"\u003eIndustrial laboratory environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5439\" data-end=\"5442\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5444\" data-end=\"5470\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5472\" data-end=\"5480\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5481\" data-end=\"5499\"\u003e\u003cstrong data-start=\"5481\" data-end=\"5499\"\u003eAS 220.R2 PLUS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5501\" data-end=\"5529\"\u003ePart Number: \u003cstrong data-start=\"5514\" data-end=\"5529\"\u003eWL-104-0177\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5531\" data-end=\"5534\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"5536\" data-end=\"5555\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"5557\" data-end=\"5586\"\u003eMaximum capacity:\u003cbr data-start=\"5574\" data-end=\"5577\"\u003e\u003cstrong data-start=\"5577\" data-end=\"5586\"\u003e220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5588\" data-end=\"5613\"\u003eMinimum load:\u003cbr data-start=\"5601\" data-end=\"5604\"\u003e\u003cstrong data-start=\"5604\" data-end=\"5613\"\u003e10 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5615\" data-end=\"5640\"\u003eReadability:\u003cbr data-start=\"5627\" data-end=\"5630\"\u003e\u003cstrong data-start=\"5630\" data-end=\"5640\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5642\" data-end=\"5666\"\u003eTare range:\u003cbr data-start=\"5653\" data-end=\"5656\"\u003e\u003cstrong data-start=\"5656\" data-end=\"5666\"\u003e−220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5668\" data-end=\"5671\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5673\" data-end=\"5683\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5685\" data-end=\"5722\"\u003eRepeatability (5% Max):\u003cbr data-start=\"5708\" data-end=\"5711\"\u003e\u003cstrong data-start=\"5711\" data-end=\"5722\"\u003e0.07 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5724\" data-end=\"5758\"\u003eRepeatability (Max):\u003cbr data-start=\"5744\" data-end=\"5747\"\u003e\u003cstrong data-start=\"5747\" data-end=\"5758\"\u003e0.08 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5760\" data-end=\"5809\"\u003ePermissible repeatability (5% Max):\u003cbr data-start=\"5795\" data-end=\"5798\"\u003e\u003cstrong data-start=\"5798\" data-end=\"5809\"\u003e0.09 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5811\" data-end=\"5856\"\u003ePermissible repeatability (Max):\u003cbr data-start=\"5843\" data-end=\"5846\"\u003e\u003cstrong data-start=\"5846\" data-end=\"5856\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5858\" data-end=\"5882\"\u003eLinearity:\u003cbr data-start=\"5868\" data-end=\"5871\"\u003e\u003cstrong data-start=\"5871\" data-end=\"5882\"\u003e±0.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5884\" data-end=\"5919\"\u003eStabilization time:\u003cbr data-start=\"5903\" data-end=\"5906\"\u003e\u003cstrong data-start=\"5906\" data-end=\"5919\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5921\" data-end=\"5924\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"5926\" data-end=\"5949\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"5951\" data-end=\"5994\"\u003eStandard minimum weight (USP):\u003cbr data-start=\"5981\" data-end=\"5984\"\u003e\u003cstrong data-start=\"5984\" data-end=\"5994\"\u003e140 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5996\" data-end=\"6048\"\u003eStandard minimum weight (U = 1%, k = 2):\u003cbr data-start=\"6036\" data-end=\"6039\"\u003e\u003cstrong data-start=\"6039\" data-end=\"6048\"\u003e14 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6050\" data-end=\"6053\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6055\" data-end=\"6064\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6066\" data-end=\"6089\"\u003e\u003cstrong data-start=\"6066\" data-end=\"6089\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6091\" data-end=\"6094\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6096\" data-end=\"6110\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6112\" data-end=\"6136\"\u003eDiameter:\u003cbr data-start=\"6121\" data-end=\"6124\"\u003e\u003cstrong data-start=\"6124\" data-end=\"6136\"\u003e4 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6138\" data-end=\"6169\"\u003eMaterial:\u003cbr data-start=\"6147\" data-end=\"6150\"\u003e\u003cstrong data-start=\"6150\" data-end=\"6169\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6171\" data-end=\"6174\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6176\" data-end=\"6190\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6192\" data-end=\"6217\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6219\" data-end=\"6294\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"6219\" data-end=\"6234\"\u003e\n\u003cp data-start=\"6221\" data-end=\"6234\"\u003e\u003cstrong data-start=\"6221\" data-end=\"6234\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6235\" data-end=\"6246\"\u003e\n\u003cp data-start=\"6237\" data-end=\"6246\"\u003e\u003cstrong data-start=\"6237\" data-end=\"6246\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6247\" data-end=\"6258\"\u003e\n\u003cp data-start=\"6249\" data-end=\"6258\"\u003e\u003cstrong data-start=\"6249\" data-end=\"6258\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"6259\" data-end=\"6273\"\u003e\n\u003cp data-start=\"6261\" data-end=\"6273\"\u003e\u003cstrong data-start=\"6261\" data-end=\"6273\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"6274\" data-end=\"6294\"\u003e\n\u003cp data-start=\"6276\" data-end=\"6294\"\u003e\u003cstrong data-start=\"6276\" data-end=\"6294\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6296\" data-end=\"6299\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6301\" data-end=\"6321\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6323\" data-end=\"6348\"\u003e\u003cstrong data-start=\"6323\" data-end=\"6348\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6350\" data-end=\"6353\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6355\" data-end=\"6377\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6379\" data-end=\"6401\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"6403\" data-end=\"6418\"\u003e\u003cstrong data-start=\"6403\" data-end=\"6418\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6420\" data-end=\"6423\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6425\" data-end=\"6446\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6448\" data-end=\"6467\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"6469\" data-end=\"6498\"\u003e\u003cstrong data-start=\"6469\" data-end=\"6498\"\u003e19.5 × 15.5 × 20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6500\" data-end=\"6512\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"6514\" data-end=\"6524\"\u003e\u003cstrong data-start=\"6514\" data-end=\"6524\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6526\" data-end=\"6542\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"6544\" data-end=\"6554\"\u003e\u003cstrong data-start=\"6544\" data-end=\"6554\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6556\" data-end=\"6559\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"6561\" data-end=\"6576\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"6578\" data-end=\"6596\"\u003e\u003cstrong data-start=\"6578\" data-end=\"6596\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6598\" data-end=\"6601\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"6603\" data-end=\"6624\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"6626\" data-end=\"6799\"\u003e\n\u003cli data-section-id=\"4i1r1w\" data-start=\"6626\" data-end=\"6674\"\u003e\n\u003cp data-start=\"6628\" data-end=\"6674\"\u003eRadwag AS 220.R2 PLUS Analytical Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yfw4sv\" data-start=\"6675\" data-end=\"6706\"\u003e\n\u003cp data-start=\"6677\" data-end=\"6706\"\u003eUniversal Power Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19f3x1w\" data-start=\"6707\" data-end=\"6735\"\u003e\n\u003cp data-start=\"6709\" data-end=\"6735\"\u003eDraft Shield for Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbmtyj\" data-start=\"6736\" data-end=\"6756\"\u003e\n\u003cp data-start=\"6738\" data-end=\"6756\"\u003ePan Assembly – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isa1dl\" data-start=\"6757\" data-end=\"6776\"\u003e\n\u003cp data-start=\"6759\" data-end=\"6776\"\u003eBalance Pad – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"6777\" data-end=\"6799\"\u003e\n\u003cp data-start=\"6779\" data-end=\"6799\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6801\" data-end=\"6804\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"6806\" data-end=\"6816\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"6818\" data-end=\"6850\"\u003e\u003cstrong data-start=\"6818\" data-end=\"6850\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6852\" data-end=\"6855\"\u003e\n\u003ch1 data-section-id=\"1wnlmxt\" data-start=\"6857\" data-end=\"6868\"\u003eDownloads\u003c\/h1\u003e\n\u003cul data-start=\"6870\" data-end=\"6947\"\u003e\n\u003cli data-section-id=\"16w5ib\" data-start=\"6870\" data-end=\"6885\"\u003e\n\u003cp data-start=\"6872\" data-end=\"6885\"\u003eUser Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fdudlh\" data-start=\"6886\" data-end=\"6906\"\u003e\n\u003cp data-start=\"6888\" data-end=\"6906\"\u003eProduct Brochure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1affvma\" data-start=\"6907\" data-end=\"6921\"\u003e\n\u003cp data-start=\"6909\" data-end=\"6921\"\u003eUSB Driver\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"163nhta\" data-start=\"6922\" data-end=\"6947\"\u003e\n\u003cp data-start=\"6924\" data-end=\"6947\"\u003eALIBI Reader Tutorial\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282571194690,"sku":null,"price":2251.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/as_r2_plus_01_as-220-r2-plus--wl-104-0177-_1.jpg?v=1773588363"},{"product_id":"across-international-wlc-6-a2-radwag-6000g-capacity-0-1g-readability-8x8-precision-balance","title":"Across International WLC 6\/A2 Radwag 6000g Capacity 0.1g Readability 8x8\" Precision Balance","description":"\u003ch2 data-section-id=\"1wokn4d\" data-start=\"379\" data-end=\"447\"\u003eReliable Precision Balance for Laboratory and Industrial Weighing\u003c\/h2\u003e\n\u003cp data-start=\"449\" data-end=\"814\"\u003eThe \u003cstrong data-start=\"453\" data-end=\"490\"\u003eRadwag WLC 6\/A2 Precision Balance\u003c\/strong\u003e is a versatile laboratory and industrial weighing solution designed for \u003cstrong data-start=\"563\" data-end=\"639\"\u003efast and accurate mass determination up to 6000 g with 0.1 g readability\u003c\/strong\u003e. Built for both laboratory and production environments, this precision balance combines reliable weighing performance with advanced data management and connectivity features.\u003c\/p\u003e\n\u003cp data-start=\"816\" data-end=\"1037\"\u003eThe balance includes a \u003cstrong data-start=\"839\" data-end=\"965\"\u003estainless steel weighing pan, backlit LCD display, multiple communication interfaces, and an internal rechargeable battery\u003c\/strong\u003e, allowing operation even in locations where mains power is unavailable.\u003c\/p\u003e\n\u003cp data-start=\"1039\" data-end=\"1303\"\u003eEquipped with \u003cstrong data-start=\"1053\" data-end=\"1171\"\u003eRS232 and USB connectivity, ALIBI memory, and advanced weighing functions such as parts counting and checkweighing\u003c\/strong\u003e, the WLC 6\/A2 balance integrates easily into laboratory workflows, quality control processes, and industrial weighing applications.\u003c\/p\u003e\n\u003chr data-start=\"1305\" data-end=\"1308\"\u003e\n\u003ch1 data-section-id=\"1eyj7vm\" data-start=\"1310\" data-end=\"1365\"\u003eKey Features of the Radwag WLC 6\/A2 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"10fpop6\" data-start=\"1367\" data-end=\"1406\"\u003eHigh Capacity with Fine Readability\u003c\/h3\u003e\n\u003cp data-start=\"1407\" data-end=\"1549\"\u003eProvides \u003cstrong data-start=\"1416\" data-end=\"1466\"\u003e6000 g maximum capacity with 0.1 g readability\u003c\/strong\u003e, ideal for weighing laboratory samples, production components, and bulk materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1o65ju6\" data-start=\"1551\" data-end=\"1588\"\u003eStainless Steel Weighing Platform\u003c\/h3\u003e\n\u003cp data-start=\"1589\" data-end=\"1691\"\u003eDurable \u003cstrong data-start=\"1597\" data-end=\"1644\"\u003e7.7 × 7.7 inch stainless steel weighing pan\u003c\/strong\u003e offers corrosion resistance and easy cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"1693\" data-end=\"1716\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1717\" data-end=\"1827\"\u003eLarge \u003cstrong data-start=\"1723\" data-end=\"1745\"\u003ebacklit LCD screen\u003c\/strong\u003e ensures clear visibility of measurement results in various lighting environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ype4r\" data-start=\"1829\" data-end=\"1862\"\u003eInternal Rechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"1863\" data-end=\"1969\"\u003eIntegrated \u003cstrong data-start=\"1874\" data-end=\"1908\"\u003esealed lead-acid (SLA) battery\u003c\/strong\u003e enables up to \u003cstrong data-start=\"1923\" data-end=\"1968\"\u003e15 hours of operation without mains power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"1971\" data-end=\"1996\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"1997\" data-end=\"2030\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2032\" data-end=\"2102\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2032\" data-end=\"2047\"\u003e\n\u003cp data-start=\"2034\" data-end=\"2047\"\u003e\u003cstrong data-start=\"2034\" data-end=\"2047\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2048\" data-end=\"2064\"\u003e\n\u003cp data-start=\"2050\" data-end=\"2064\"\u003e\u003cstrong data-start=\"2050\" data-end=\"2064\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2065\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2067\" data-end=\"2081\"\u003e\u003cstrong data-start=\"2067\" data-end=\"2081\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"2082\" data-end=\"2102\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2102\"\u003e\u003cstrong data-start=\"2084\" data-end=\"2102\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2104\" data-end=\"2187\"\u003eThese allow connection to printers, computers, USB drives, and additional displays.\u003c\/p\u003e\n\u003ch3 data-section-id=\"rz7j0t\" data-start=\"2189\" data-end=\"2212\"\u003eALIBI Memory System\u003c\/h3\u003e\n\u003cp data-start=\"2213\" data-end=\"2333\"\u003eIntegrated \u003cstrong data-start=\"2224\" data-end=\"2282\"\u003eALIBI memory records and securely stores weighing data\u003c\/strong\u003e, ensuring reliable documentation and traceability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r9401y\" data-start=\"2335\" data-end=\"2362\"\u003eOptional Industrial I\/O\u003c\/h3\u003e\n\u003cp data-start=\"2363\" data-end=\"2477\"\u003eThe system can optionally support \u003cstrong data-start=\"2397\" data-end=\"2425\"\u003e4 IN \/ 4 OUT connections\u003c\/strong\u003e for integration with industrial automation systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"2479\" data-end=\"2501\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"2502\" data-end=\"2603\"\u003eIncludes \u003cstrong data-start=\"2511\" data-end=\"2541\"\u003eunderhook weighing adapter\u003c\/strong\u003e, allowing suspended weighing of irregular or oversized items.\u003c\/p\u003e\n\u003chr data-start=\"2605\" data-end=\"2608\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"2610\" data-end=\"2639\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"2641\" data-end=\"2759\"\u003eThe WLC series balances provide multiple professional weighing modes suitable for laboratory and industrial workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlrqzv\" data-start=\"2761\" data-end=\"2799\"\u003eCheckweighing (Plus\/Minus Control)\u003c\/h3\u003e\n\u003cp data-start=\"2800\" data-end=\"2942\"\u003eAllows verification of sample mass against predefined \u003cstrong data-start=\"2854\" data-end=\"2880\"\u003eMIN and MAX thresholds\u003c\/strong\u003e, with visual feedback displayed as a \u003cstrong data-start=\"2918\" data-end=\"2941\"\u003ebar graph indicator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"2944\" data-end=\"2964\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"2965\" data-end=\"3089\"\u003eCompares sample weight with a reference mass standard, displaying the result as a percentage relative to the standard value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"3091\" data-end=\"3105\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"3106\" data-end=\"3197\"\u003eAdds multiple weighing results together to determine the total mass of mixtures or batches.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3199\" data-end=\"3217\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3218\" data-end=\"3380\"\u003eDetermines the quantity of items based on total mass and known individual item weight. Includes \u003cstrong data-start=\"3314\" data-end=\"3347\"\u003eautomatic accuracy correction\u003c\/strong\u003e for improved counting precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3382\" data-end=\"3395\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3396\" data-end=\"3490\"\u003eCaptures and holds the \u003cstrong data-start=\"3419\" data-end=\"3455\"\u003ehighest temporary weight reading\u003c\/strong\u003e during dynamic weighing processes.\u003c\/p\u003e\n\u003chr data-start=\"3492\" data-end=\"3495\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3497\" data-end=\"3517\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3519\" data-end=\"3575\"\u003eThe Radwag WLC 6\/A2 precision balance is widely used in:\u003c\/p\u003e\n\u003cul data-start=\"3577\" data-end=\"3782\"\u003e\n\u003cli data-section-id=\"c17ahl\" data-start=\"3577\" data-end=\"3605\"\u003e\n\u003cp data-start=\"3579\" data-end=\"3605\"\u003eLaboratory sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"52ibyd\" data-start=\"3606\" data-end=\"3634\"\u003e\n\u003cp data-start=\"3608\" data-end=\"3634\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t4lz9r\" data-start=\"3635\" data-end=\"3665\"\u003e\n\u003cp data-start=\"3637\" data-end=\"3665\"\u003eManufacturing parts counting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xj3yhp\" data-start=\"3666\" data-end=\"3687\"\u003e\n\u003cp data-start=\"3668\" data-end=\"3687\"\u003eMaterial inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ony6z2\" data-start=\"3688\" data-end=\"3712\"\u003e\n\u003cp data-start=\"3690\" data-end=\"3712\"\u003ePackaging verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ww9539\" data-start=\"3713\" data-end=\"3755\"\u003e\n\u003cp data-start=\"3715\" data-end=\"3755\"\u003eChemical and pharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n3djqi\" data-start=\"3756\" data-end=\"3782\"\u003e\n\u003cp data-start=\"3758\" data-end=\"3782\"\u003eEducational laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3784\" data-end=\"3787\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3789\" data-end=\"3815\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3817\" data-end=\"3825\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3826\" data-end=\"3838\"\u003e\u003cstrong data-start=\"3826\" data-end=\"3838\"\u003eWLC 6\/A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3840\" data-end=\"3868\"\u003ePart Number: \u003cstrong data-start=\"3853\" data-end=\"3868\"\u003eWL-206-0003\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3870\" data-end=\"3873\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"3875\" data-end=\"3894\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"3896\" data-end=\"3926\"\u003eMaximum capacity:\u003cbr data-start=\"3913\" data-end=\"3916\"\u003e\u003cstrong data-start=\"3916\" data-end=\"3926\"\u003e6000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3928\" data-end=\"3951\"\u003eMinimum load:\u003cbr data-start=\"3941\" data-end=\"3944\"\u003e\u003cstrong data-start=\"3944\" data-end=\"3951\"\u003e5 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3953\" data-end=\"3977\"\u003eReadability:\u003cbr data-start=\"3965\" data-end=\"3968\"\u003e\u003cstrong data-start=\"3968\" data-end=\"3977\"\u003e0.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3979\" data-end=\"4002\"\u003eTare range:\u003cbr data-start=\"3990\" data-end=\"3993\"\u003e\u003cstrong data-start=\"3993\" data-end=\"4002\"\u003e−6 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4004\" data-end=\"4007\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4009\" data-end=\"4019\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4021\" data-end=\"4047\"\u003eRepeatability:\u003cbr data-start=\"4035\" data-end=\"4038\"\u003e\u003cstrong data-start=\"4038\" data-end=\"4047\"\u003e0.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4049\" data-end=\"4072\"\u003eLinearity:\u003cbr data-start=\"4059\" data-end=\"4062\"\u003e\u003cstrong data-start=\"4062\" data-end=\"4072\"\u003e±0.2 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4074\" data-end=\"4109\"\u003eStabilization time:\u003cbr data-start=\"4093\" data-end=\"4096\"\u003e\u003cstrong data-start=\"4096\" data-end=\"4109\"\u003e3 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4111\" data-end=\"4114\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4116\" data-end=\"4125\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4127\" data-end=\"4150\"\u003e\u003cstrong data-start=\"4127\" data-end=\"4150\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4152\" data-end=\"4155\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4157\" data-end=\"4176\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4178\" data-end=\"4212\"\u003eDimensions:\u003cbr data-start=\"4189\" data-end=\"4192\"\u003e\u003cstrong data-start=\"4192\" data-end=\"4212\"\u003e7.7 × 7.7 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4214\" data-end=\"4245\"\u003eMaterial:\u003cbr data-start=\"4223\" data-end=\"4226\"\u003e\u003cstrong data-start=\"4226\" data-end=\"4245\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4247\" data-end=\"4250\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4252\" data-end=\"4266\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4268\" data-end=\"4293\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4295\" data-end=\"4355\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4295\" data-end=\"4310\"\u003e\n\u003cp data-start=\"4297\" data-end=\"4310\"\u003e\u003cstrong data-start=\"4297\" data-end=\"4310\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4311\" data-end=\"4322\"\u003e\n\u003cp data-start=\"4313\" data-end=\"4322\"\u003e\u003cstrong data-start=\"4313\" data-end=\"4322\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4323\" data-end=\"4334\"\u003e\n\u003cp data-start=\"4325\" data-end=\"4334\"\u003e\u003cstrong data-start=\"4325\" data-end=\"4334\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4335\" data-end=\"4355\"\u003e\n\u003cp data-start=\"4337\" data-end=\"4355\"\u003e\u003cstrong data-start=\"4337\" data-end=\"4355\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4357\" data-end=\"4403\"\u003eOptional \u003cstrong data-start=\"4366\" data-end=\"4403\"\u003e4 IN \/ 4 OUT industrial interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4405\" data-end=\"4408\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4410\" data-end=\"4430\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4432\" data-end=\"4457\"\u003e\u003cstrong data-start=\"4432\" data-end=\"4457\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4459\" data-end=\"4482\"\u003eBattery operation time:\u003c\/p\u003e\n\u003cp data-start=\"4484\" data-end=\"4504\"\u003e\u003cstrong data-start=\"4484\" data-end=\"4504\"\u003eApprox. 15 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4506\" data-end=\"4509\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4511\" data-end=\"4537\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4539\" data-end=\"4561\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4563\" data-end=\"4578\"\u003e\u003cstrong data-start=\"4563\" data-end=\"4578\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4580\" data-end=\"4598\"\u003eRelative humidity:\u003c\/p\u003e\n\u003cp data-start=\"4600\" data-end=\"4633\"\u003e\u003cstrong data-start=\"4600\" data-end=\"4633\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4635\" data-end=\"4638\"\u003e\n\u003ch1 data-section-id=\"1tt54le\" data-start=\"4640\" data-end=\"4659\"\u003eProtection Rating\u003c\/h1\u003e\n\u003cp data-start=\"4661\" data-end=\"4669\"\u003e\u003cstrong data-start=\"4661\" data-end=\"4669\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4671\" data-end=\"4674\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4676\" data-end=\"4697\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4699\" data-end=\"4718\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4720\" data-end=\"4745\"\u003e\u003cstrong data-start=\"4720\" data-end=\"4745\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4747\" data-end=\"4759\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"4761\" data-end=\"4770\"\u003e\u003cstrong data-start=\"4761\" data-end=\"4770\"\u003e5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4772\" data-end=\"4788\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"4790\" data-end=\"4801\"\u003e\u003cstrong data-start=\"4790\" data-end=\"4801\"\u003e9.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4803\" data-end=\"4806\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"4808\" data-end=\"4823\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"4825\" data-end=\"4853\"\u003e\u003cstrong data-start=\"4825\" data-end=\"4844\"\u003eNTEP Certified:\u003c\/strong\u003e Optional\u003c\/p\u003e\n\u003chr data-start=\"4855\" data-end=\"4858\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"4860\" data-end=\"4881\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"4883\" data-end=\"5126\"\u003e\n\u003cli data-section-id=\"i0707i\" data-start=\"4883\" data-end=\"4924\"\u003e\n\u003cp data-start=\"4885\" data-end=\"4924\"\u003eRadwag WLC 6\/A2 Precision Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kemj4y\" data-start=\"4925\" data-end=\"4961\"\u003e\n\u003cp data-start=\"4927\" data-end=\"4961\"\u003eStainless Steel Weighing Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17jzr3a\" data-start=\"4962\" data-end=\"5000\"\u003e\n\u003cp data-start=\"4964\" data-end=\"5000\"\u003eGrounding Foot (Spring Center) – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k4km4t\" data-start=\"5001\" data-end=\"5024\"\u003e\n\u003cp data-start=\"5003\" data-end=\"5024\"\u003eAdjustable Feet – 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v7a5cy\" data-start=\"5025\" data-end=\"5059\"\u003e\n\u003cp data-start=\"5027\" data-end=\"5059\"\u003eUnderhook Weighing Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"khd6o2\" data-start=\"5060\" data-end=\"5081\"\u003e\n\u003cp data-start=\"5062\" data-end=\"5081\"\u003ePower Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j22hfp\" data-start=\"5082\" data-end=\"5103\"\u003e\n\u003cp data-start=\"5084\" data-end=\"5103\"\u003ePlug Adapters – 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"5104\" data-end=\"5126\"\u003e\n\u003cp data-start=\"5106\" data-end=\"5126\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5128\" data-end=\"5131\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5133\" data-end=\"5143\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5145\" data-end=\"5177\"\u003e\u003cstrong data-start=\"5145\" data-end=\"5177\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282580861250,"sku":null,"price":713.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/wlca-2-10b_wlc-6a2--wl-206-0003-1.jpg?v=1773588604"},{"product_id":"across-international-wlc-2-a2-radwag-2000g-capacity-0-01g-readability-8x8-precision-balance","title":"Across International WLC 2\/A2 Radwag 2000g Capacity 0.01g Readability 8x8\" Precision Balance","description":"\u003ch2 data-section-id=\"spff9n\" data-start=\"382\" data-end=\"455\"\u003eHigh-Accuracy Precision Balance for Laboratory and Industrial Weighing\u003c\/h2\u003e\n\u003cp data-start=\"457\" data-end=\"806\"\u003eThe \u003cstrong data-start=\"461\" data-end=\"498\"\u003eRadwag WLC 2\/A2 Precision Balance\u003c\/strong\u003e is a reliable weighing solution designed for \u003cstrong data-start=\"544\" data-end=\"628\"\u003eaccurate mass determination in laboratory, research, and industrial environments\u003c\/strong\u003e. With a \u003cstrong data-start=\"637\" data-end=\"690\"\u003emaximum capacity of 2000 g and 0.01 g readability\u003c\/strong\u003e, this balance provides precise measurement results while maintaining fast stabilization and consistent performance.\u003c\/p\u003e\n\u003cp data-start=\"808\" data-end=\"1003\"\u003eThe device features a \u003cstrong data-start=\"830\" data-end=\"926\"\u003edurable stainless steel weighing pan, backlit LCD display, and internal rechargeable battery\u003c\/strong\u003e, allowing operation even in environments where mains power is not available.\u003c\/p\u003e\n\u003cp data-start=\"1005\" data-end=\"1267\"\u003eEquipped with \u003cstrong data-start=\"1019\" data-end=\"1061\"\u003eRS232 and USB communication interfaces\u003c\/strong\u003e, the WLC 2\/A2 balance easily connects to computers, printers, USB drives, and additional displays. Integrated \u003cstrong data-start=\"1172\" data-end=\"1208\"\u003eALIBI memory and real-time clock\u003c\/strong\u003e enable secure recording and traceability of weighing data.\u003c\/p\u003e\n\u003cp data-start=\"1269\" data-end=\"1436\"\u003eDesigned for flexibility and reliability, this precision balance is suitable for \u003cstrong data-start=\"1350\" data-end=\"1435\"\u003elaboratory weighing, quality control, manufacturing, and educational environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1438\" data-end=\"1441\"\u003e\n\u003ch1 data-section-id=\"1nz1mhy\" data-start=\"1443\" data-end=\"1498\"\u003eKey Features of the Radwag WLC 2\/A2 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1id2ox0\" data-start=\"1500\" data-end=\"1536\"\u003ePrecise and Reliable Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1537\" data-end=\"1660\"\u003eProvides \u003cstrong data-start=\"1546\" data-end=\"1589\"\u003e2000 g capacity with 0.01 g readability\u003c\/strong\u003e, ensuring accurate results for laboratory and industrial applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1o65ju6\" data-start=\"1662\" data-end=\"1699\"\u003eStainless Steel Weighing Platform\u003c\/h3\u003e\n\u003cp data-start=\"1700\" data-end=\"1813\"\u003eThe \u003cstrong data-start=\"1704\" data-end=\"1751\"\u003e7.7 × 7.7 inch stainless steel weighing pan\u003c\/strong\u003e provides durability, corrosion resistance, and easy cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"1815\" data-end=\"1838\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1839\" data-end=\"1943\"\u003eClear \u003cstrong data-start=\"1845\" data-end=\"1867\"\u003ebacklit LCD screen\u003c\/strong\u003e ensures easy reading of measurement results in various lighting conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ype4r\" data-start=\"1945\" data-end=\"1978\"\u003eInternal Rechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"1979\" data-end=\"2131\"\u003eIntegrated \u003cstrong data-start=\"1990\" data-end=\"2018\"\u003esealed lead-acid battery\u003c\/strong\u003e enables up to \u003cstrong data-start=\"2033\" data-end=\"2078\"\u003e15 hours of operation without mains power\u003c\/strong\u003e, ideal for portable or remote weighing applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"2133\" data-end=\"2158\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2159\" data-end=\"2201\"\u003eBuilt-in communication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2203\" data-end=\"2273\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2203\" data-end=\"2218\"\u003e\n\u003cp data-start=\"2205\" data-end=\"2218\"\u003e\u003cstrong data-start=\"2205\" data-end=\"2218\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2219\" data-end=\"2235\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2235\"\u003e\u003cstrong data-start=\"2221\" data-end=\"2235\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2236\" data-end=\"2252\"\u003e\n\u003cp data-start=\"2238\" data-end=\"2252\"\u003e\u003cstrong data-start=\"2238\" data-end=\"2252\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"2253\" data-end=\"2273\"\u003e\n\u003cp data-start=\"2255\" data-end=\"2273\"\u003e\u003cstrong data-start=\"2255\" data-end=\"2273\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2275\" data-end=\"2376\"\u003eThese interfaces allow seamless integration with laboratory systems, printers, and external displays.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1abnyzw\" data-start=\"2378\" data-end=\"2403\"\u003eSecure Data Recording\u003c\/h3\u003e\n\u003cp data-start=\"2404\" data-end=\"2533\"\u003eThe balance includes \u003cstrong data-start=\"2425\" data-end=\"2463\"\u003eALIBI memory and a real-time clock\u003c\/strong\u003e, ensuring reliable data storage and traceability of weighing results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"186nltk\" data-start=\"2535\" data-end=\"2568\"\u003eUnder-Pan Weighing Capability\u003c\/h3\u003e\n\u003cp data-start=\"2569\" data-end=\"2675\"\u003eIncludes an \u003cstrong data-start=\"2581\" data-end=\"2611\"\u003eunderhook weighing adapter\u003c\/strong\u003e, allowing suspended weighing of irregular or oversized objects.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1r9401y\" data-start=\"2677\" data-end=\"2704\"\u003eOptional Industrial I\/O\u003c\/h3\u003e\n\u003cp data-start=\"2705\" data-end=\"2819\"\u003eThe system can optionally support \u003cstrong data-start=\"2739\" data-end=\"2767\"\u003e4 IN \/ 4 OUT connections\u003c\/strong\u003e for integration with industrial automation systems.\u003c\/p\u003e\n\u003chr data-start=\"2821\" data-end=\"2824\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"2826\" data-end=\"2855\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"2857\" data-end=\"2987\"\u003eThe WLC series precision balances include several professional weighing modes suitable for laboratory and production environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlrqzv\" data-start=\"2989\" data-end=\"3027\"\u003eCheckweighing (Plus\/Minus Control)\u003c\/h3\u003e\n\u003cp data-start=\"3028\" data-end=\"3171\"\u003eAllows verification of sample mass using predefined \u003cstrong data-start=\"3080\" data-end=\"3114\"\u003eminimum and maximum thresholds\u003c\/strong\u003e, with results displayed using a \u003cstrong data-start=\"3147\" data-end=\"3170\"\u003ebar graph indicator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"3173\" data-end=\"3193\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3194\" data-end=\"3319\"\u003eCompares the weight of a sample with a reference mass standard, displaying the result as a percentage of the reference value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"3321\" data-end=\"3335\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"3336\" data-end=\"3444\"\u003eAutomatically adds multiple weighing results together, enabling accurate measurement of mixtures or batches.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3446\" data-end=\"3464\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3465\" data-end=\"3625\"\u003eCalculates the quantity of items based on total weight and known unit mass. The system includes \u003cstrong data-start=\"3561\" data-end=\"3594\"\u003eautomatic accuracy correction\u003c\/strong\u003e to improve counting precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3627\" data-end=\"3640\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3641\" data-end=\"3733\"\u003eCaptures and holds the \u003cstrong data-start=\"3664\" data-end=\"3698\"\u003ehighest temporary weight value\u003c\/strong\u003e during dynamic weighing processes.\u003c\/p\u003e\n\u003chr data-start=\"3735\" data-end=\"3738\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3740\" data-end=\"3760\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3762\" data-end=\"3820\"\u003eThe Radwag WLC 2\/A2 precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3822\" data-end=\"4038\"\u003e\n\u003cli data-section-id=\"c17ahl\" data-start=\"3822\" data-end=\"3850\"\u003e\n\u003cp data-start=\"3824\" data-end=\"3850\"\u003eLaboratory sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"52ibyd\" data-start=\"3851\" data-end=\"3879\"\u003e\n\u003cp data-start=\"3853\" data-end=\"3879\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t4lz9r\" data-start=\"3880\" data-end=\"3910\"\u003e\n\u003cp data-start=\"3882\" data-end=\"3910\"\u003eManufacturing parts counting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xj3yhp\" data-start=\"3911\" data-end=\"3932\"\u003e\n\u003cp data-start=\"3913\" data-end=\"3932\"\u003eMaterial inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ony6z2\" data-start=\"3933\" data-end=\"3957\"\u003e\n\u003cp data-start=\"3935\" data-end=\"3957\"\u003ePackaging verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dyy1et\" data-start=\"3958\" data-end=\"4000\"\u003e\n\u003cp data-start=\"3960\" data-end=\"4000\"\u003ePharmaceutical and chemical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ebh4a\" data-start=\"4001\" data-end=\"4038\"\u003e\n\u003cp data-start=\"4003\" data-end=\"4038\"\u003eEducational laboratory environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4040\" data-end=\"4043\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4045\" data-end=\"4071\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4073\" data-end=\"4081\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4082\" data-end=\"4094\"\u003e\u003cstrong data-start=\"4082\" data-end=\"4094\"\u003eWLC 2\/A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4096\" data-end=\"4124\"\u003ePart Number: \u003cstrong data-start=\"4109\" data-end=\"4124\"\u003eWL-206-0039\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4126\" data-end=\"4129\"\u003e\n\u003ch1 data-section-id=\"1rg7kg6\" data-start=\"4131\" data-end=\"4150\"\u003eWeighing Capacity\u003c\/h1\u003e\n\u003cp data-start=\"4152\" data-end=\"4182\"\u003eMaximum capacity:\u003cbr data-start=\"4169\" data-end=\"4172\"\u003e\u003cstrong data-start=\"4172\" data-end=\"4182\"\u003e2000 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4184\" data-end=\"4209\"\u003eReadability:\u003cbr data-start=\"4196\" data-end=\"4199\"\u003e\u003cstrong data-start=\"4199\" data-end=\"4209\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4211\" data-end=\"4234\"\u003eTare range:\u003cbr data-start=\"4222\" data-end=\"4225\"\u003e\u003cstrong data-start=\"4225\" data-end=\"4234\"\u003e−2 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4236\" data-end=\"4239\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4241\" data-end=\"4251\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4253\" data-end=\"4280\"\u003eRepeatability:\u003cbr data-start=\"4267\" data-end=\"4270\"\u003e\u003cstrong data-start=\"4270\" data-end=\"4280\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4282\" data-end=\"4306\"\u003eLinearity:\u003cbr data-start=\"4292\" data-end=\"4295\"\u003e\u003cstrong data-start=\"4295\" data-end=\"4306\"\u003e±0.03 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4308\" data-end=\"4343\"\u003eStabilization time:\u003cbr data-start=\"4327\" data-end=\"4330\"\u003e\u003cstrong data-start=\"4330\" data-end=\"4343\"\u003e3 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4345\" data-end=\"4348\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4350\" data-end=\"4359\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4361\" data-end=\"4384\"\u003e\u003cstrong data-start=\"4361\" data-end=\"4384\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4386\" data-end=\"4389\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4391\" data-end=\"4410\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4412\" data-end=\"4446\"\u003eDimensions:\u003cbr data-start=\"4423\" data-end=\"4426\"\u003e\u003cstrong data-start=\"4426\" data-end=\"4446\"\u003e7.7 × 7.7 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4448\" data-end=\"4479\"\u003eMaterial:\u003cbr data-start=\"4457\" data-end=\"4460\"\u003e\u003cstrong data-start=\"4460\" data-end=\"4479\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4481\" data-end=\"4484\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4486\" data-end=\"4500\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4502\" data-end=\"4527\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4529\" data-end=\"4589\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4529\" data-end=\"4544\"\u003e\n\u003cp data-start=\"4531\" data-end=\"4544\"\u003e\u003cstrong data-start=\"4531\" data-end=\"4544\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4545\" data-end=\"4556\"\u003e\n\u003cp data-start=\"4547\" data-end=\"4556\"\u003e\u003cstrong data-start=\"4547\" data-end=\"4556\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4557\" data-end=\"4568\"\u003e\n\u003cp data-start=\"4559\" data-end=\"4568\"\u003e\u003cstrong data-start=\"4559\" data-end=\"4568\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4569\" data-end=\"4589\"\u003e\n\u003cp data-start=\"4571\" data-end=\"4589\"\u003e\u003cstrong data-start=\"4571\" data-end=\"4589\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4591\" data-end=\"4637\"\u003eOptional \u003cstrong data-start=\"4600\" data-end=\"4637\"\u003e4 IN \/ 4 OUT industrial interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4639\" data-end=\"4642\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4644\" data-end=\"4664\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4666\" data-end=\"4691\"\u003e\u003cstrong data-start=\"4666\" data-end=\"4691\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4693\" data-end=\"4716\"\u003eBattery operation time:\u003c\/p\u003e\n\u003cp data-start=\"4718\" data-end=\"4738\"\u003e\u003cstrong data-start=\"4718\" data-end=\"4738\"\u003eApprox. 15 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4740\" data-end=\"4743\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4745\" data-end=\"4771\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4773\" data-end=\"4795\"\u003eOperating temperature:\u003c\/p\u003e\n\u003cp data-start=\"4797\" data-end=\"4812\"\u003e\u003cstrong data-start=\"4797\" data-end=\"4812\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4814\" data-end=\"4832\"\u003eRelative humidity:\u003c\/p\u003e\n\u003cp data-start=\"4834\" data-end=\"4867\"\u003e\u003cstrong data-start=\"4834\" data-end=\"4867\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4869\" data-end=\"4872\"\u003e\n\u003ch1 data-section-id=\"1tt54le\" data-start=\"4874\" data-end=\"4893\"\u003eProtection Rating\u003c\/h1\u003e\n\u003cp data-start=\"4895\" data-end=\"4903\"\u003e\u003cstrong data-start=\"4895\" data-end=\"4903\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4905\" data-end=\"4908\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4910\" data-end=\"4931\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4933\" data-end=\"4952\"\u003ePackage dimensions:\u003c\/p\u003e\n\u003cp data-start=\"4954\" data-end=\"4979\"\u003e\u003cstrong data-start=\"4954\" data-end=\"4979\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4981\" data-end=\"4993\"\u003eUnit weight:\u003c\/p\u003e\n\u003cp data-start=\"4995\" data-end=\"5004\"\u003e\u003cstrong data-start=\"4995\" data-end=\"5004\"\u003e5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5006\" data-end=\"5022\"\u003eShipping weight:\u003c\/p\u003e\n\u003cp data-start=\"5024\" data-end=\"5035\"\u003e\u003cstrong data-start=\"5024\" data-end=\"5035\"\u003e9.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5037\" data-end=\"5040\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"5042\" data-end=\"5057\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"5059\" data-end=\"5092\"\u003e\u003cstrong data-start=\"5059\" data-end=\"5078\"\u003eNTEP Certified:\u003c\/strong\u003e Not available\u003c\/p\u003e\n\u003chr data-start=\"5094\" data-end=\"5097\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5099\" data-end=\"5120\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5122\" data-end=\"5365\"\u003e\n\u003cli data-section-id=\"11oo9qi\" data-start=\"5122\" data-end=\"5163\"\u003e\n\u003cp data-start=\"5124\" data-end=\"5163\"\u003eRadwag WLC 2\/A2 Precision Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kemj4y\" data-start=\"5164\" data-end=\"5200\"\u003e\n\u003cp data-start=\"5166\" data-end=\"5200\"\u003eStainless Steel Weighing Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17jzr3a\" data-start=\"5201\" data-end=\"5239\"\u003e\n\u003cp data-start=\"5203\" data-end=\"5239\"\u003eGrounding Foot (Spring Center) – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k4km4t\" data-start=\"5240\" data-end=\"5263\"\u003e\n\u003cp data-start=\"5242\" data-end=\"5263\"\u003eAdjustable Feet – 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v7a5cy\" data-start=\"5264\" data-end=\"5298\"\u003e\n\u003cp data-start=\"5266\" data-end=\"5298\"\u003eUnderhook Weighing Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"khd6o2\" data-start=\"5299\" data-end=\"5320\"\u003e\n\u003cp data-start=\"5301\" data-end=\"5320\"\u003ePower Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j22hfp\" data-start=\"5321\" data-end=\"5342\"\u003e\n\u003cp data-start=\"5323\" data-end=\"5342\"\u003ePlug Adapters – 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"5343\" data-end=\"5365\"\u003e\n\u003cp data-start=\"5345\" data-end=\"5365\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5367\" data-end=\"5370\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5372\" data-end=\"5382\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5384\" data-end=\"5416\"\u003e\u003cstrong data-start=\"5384\" data-end=\"5416\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282586595650,"sku":null,"price":757.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/wlca-2-10b_wlc-2a2--wl-206-0039-1.jpg?v=1773588816"},{"product_id":"across-international-ps-2100-r2-m-radwag-r2-2100g-capacity-0-01g-readability-8x8-precision-balance","title":"Across International PS 2100.R2.M Radwag R2 2100g Capacity 0.01g Readability 8x8\" Precision Balance","description":"\u003ch2 data-section-id=\"ddww4w\" data-start=\"361\" data-end=\"430\"\u003eHigh-Resolution Precision Balance with RADWAG MonoBLOCK Technology\u003c\/h2\u003e\n\u003cp data-start=\"432\" data-end=\"779\"\u003eThe \u003cstrong data-start=\"436\" data-end=\"477\"\u003eRadwag RS 2100.R2.M Precision Balance\u003c\/strong\u003e is a high-resolution laboratory weighing instrument designed for \u003cstrong data-start=\"543\" data-end=\"611\"\u003eaccurate mass determination up to 2100 g with 0.01 g readability\u003c\/strong\u003e. Built using \u003cstrong data-start=\"625\" data-end=\"656\"\u003eRADWAG MonoBLOCK technology\u003c\/strong\u003e, the RS R2.M series delivers exceptional measurement stability, repeatability, and resistance to environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"781\" data-end=\"1071\"\u003eThe innovative \u003cstrong data-start=\"796\" data-end=\"842\"\u003esingle-point weighing pan fastening system\u003c\/strong\u003e ensures excellent weighing geometry while minimizing eccentricity errors. Additionally, the \u003cstrong data-start=\"935\" data-end=\"971\"\u003elabyrinth-style fastening design\u003c\/strong\u003e protects the weighing mechanism from contamination, improving long-term durability and reliability.\u003c\/p\u003e\n\u003cp data-start=\"1073\" data-end=\"1269\"\u003eAn advanced \u003cstrong data-start=\"1085\" data-end=\"1125\"\u003einternal automatic adjustment system\u003c\/strong\u003e continuously maintains precision across the entire measurement range, ensuring consistent results even under changing environmental conditions.\u003c\/p\u003e\n\u003cp data-start=\"1271\" data-end=\"1467\"\u003eWith \u003cstrong data-start=\"1276\" data-end=\"1353\"\u003eintegrated databases, ALIBI memory, and multiple communication interfaces\u003c\/strong\u003e, the RS 2100.R2.M precision balance integrates easily into laboratory data systems and quality control workflows.\u003c\/p\u003e\n\u003chr data-start=\"1469\" data-end=\"1472\"\u003e\n\u003ch1 data-section-id=\"6czv7j\" data-start=\"1474\" data-end=\"1533\"\u003eKey Features of the Radwag RS 2100.R2.M Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"6gfpsk\" data-start=\"1535\" data-end=\"1565\"\u003eHigh Precision Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1566\" data-end=\"1676\"\u003eProvides \u003cstrong data-start=\"1575\" data-end=\"1618\"\u003e2100 g capacity with 0.01 g readability\u003c\/strong\u003e, making it ideal for precision laboratory weighing tasks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xds5ho\" data-start=\"1678\" data-end=\"1709\"\u003eRADWAG MonoBLOCK Technology\u003c\/h3\u003e\n\u003cp data-start=\"1710\" data-end=\"1754\"\u003eAdvanced MonoBLOCK weighing system improves:\u003c\/p\u003e\n\u003cul data-start=\"1756\" data-end=\"1824\"\u003e\n\u003cli data-section-id=\"a5fohz\" data-start=\"1756\" data-end=\"1779\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1779\"\u003eMeasurement stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ie87av\" data-start=\"1780\" data-end=\"1798\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1798\"\u003eShock resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sbupkk\" data-start=\"1799\" data-end=\"1824\"\u003e\n\u003cp data-start=\"1801\" data-end=\"1824\"\u003eLong-term repeatability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1eug8ab\" data-start=\"1826\" data-end=\"1859\"\u003eInternal Automatic Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"1860\" data-end=\"1959\"\u003eInternal calibration ensures \u003cstrong data-start=\"1889\" data-end=\"1958\"\u003ehigh accuracy and repeatability across the entire measuring range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ye59w6\" data-start=\"1961\" data-end=\"1990\"\u003eDurable Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"1991\" data-end=\"2073\"\u003eRigid base construction provides excellent stability and resistance to vibrations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"owdhd4\" data-start=\"2075\" data-end=\"2112\"\u003eContamination-Resistant Pan Mount\u003c\/h3\u003e\n\u003cp data-start=\"2113\" data-end=\"2209\"\u003eThe \u003cstrong data-start=\"2117\" data-end=\"2157\"\u003elabyrinth-style pan fastening system\u003c\/strong\u003e protects the weighing mechanism from contamination.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"2211\" data-end=\"2234\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"2235\" data-end=\"2331\"\u003eLarge \u003cstrong data-start=\"2241\" data-end=\"2263\"\u003ebacklit LCD screen\u003c\/strong\u003e provides clear measurement results and intuitive data presentation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2bc4pe\" data-start=\"2333\" data-end=\"2359\"\u003eQuick Access Operation\u003c\/h3\u003e\n\u003cp data-start=\"2360\" data-end=\"2405\"\u003eDedicated function keys allow fast access to:\u003c\/p\u003e\n\u003cul data-start=\"2407\" data-end=\"2461\"\u003e\n\u003cli data-section-id=\"1tig6nz\" data-start=\"2407\" data-end=\"2426\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2426\"\u003eBalance functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w57mf2\" data-start=\"2427\" data-end=\"2438\"\u003e\n\u003cp data-start=\"2429\" data-end=\"2438\"\u003eDatabases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s5jls7\" data-start=\"2439\" data-end=\"2461\"\u003e\n\u003cp data-start=\"2441\" data-end=\"2461\"\u003eMeasurement settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"2463\" data-end=\"2488\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2489\" data-end=\"2522\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2524\" data-end=\"2607\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2524\" data-end=\"2539\"\u003e\n\u003cp data-start=\"2526\" data-end=\"2539\"\u003e\u003cstrong data-start=\"2526\" data-end=\"2539\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2540\" data-end=\"2556\"\u003e\n\u003cp data-start=\"2542\" data-end=\"2556\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2556\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2557\" data-end=\"2573\"\u003e\n\u003cp data-start=\"2559\" data-end=\"2573\"\u003e\u003cstrong data-start=\"2559\" data-end=\"2573\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cq3jcv\" data-start=\"2574\" data-end=\"2607\"\u003e\n\u003cp data-start=\"2576\" data-end=\"2607\"\u003e\u003cstrong data-start=\"2576\" data-end=\"2607\"\u003eOptional Wi-Fi connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2609\" data-end=\"2696\"\u003eThese allow connection to computers, printers, USB drives, and laboratory data systems.\u003c\/p\u003e\n\u003chr data-start=\"2698\" data-end=\"2701\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"2703\" data-end=\"2738\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"2740\" data-end=\"2851\"\u003eThe RS R2.M balance series includes an advanced internal database system for measurement tracking and analysis.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"2853\" data-end=\"2874\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"2876\" data-end=\"3023\"\u003e\n\u003cli data-section-id=\"bsi9cc\" data-start=\"2876\" data-end=\"2910\"\u003e\n\u003cp data-start=\"2878\" data-end=\"2910\"\u003e\u003cstrong data-start=\"2878\" data-end=\"2892\"\u003eOperators:\u003c\/strong\u003e up to 100 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d70vn1\" data-start=\"2911\" data-end=\"2948\"\u003e\n\u003cp data-start=\"2913\" data-end=\"2948\"\u003e\u003cstrong data-start=\"2913\" data-end=\"2926\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r9m2z4\" data-start=\"2949\" data-end=\"2986\"\u003e\n\u003cp data-start=\"2951\" data-end=\"2986\"\u003e\u003cstrong data-start=\"2951\" data-end=\"2965\"\u003eWeighings:\u003c\/strong\u003e up to 5000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"2987\" data-end=\"3023\"\u003e\n\u003cp data-start=\"2989\" data-end=\"3023\"\u003e\u003cstrong data-start=\"2989\" data-end=\"2999\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3025\" data-end=\"3041\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3043\" data-end=\"3217\"\u003eThe built-in \u003cstrong data-start=\"3056\" data-end=\"3114\"\u003eALIBI memory securely records up to 100,000 weighments\u003c\/strong\u003e, ensuring reliable long-term data traceability and compliance with laboratory documentation standards.\u003c\/p\u003e\n\u003chr data-start=\"3219\" data-end=\"3222\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3224\" data-end=\"3253\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"3255\" data-end=\"3347\"\u003eThe RS 2100.R2.M precision balance supports a wide range of professional weighing functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"3349\" data-end=\"3361\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"3362\" data-end=\"3488\"\u003eAutomatic diagnostic function that evaluates \u003cstrong data-start=\"3407\" data-end=\"3452\"\u003erepeatability and metrological parameters\u003c\/strong\u003e based on real operating conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"3490\" data-end=\"3500\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"3501\" data-end=\"3626\"\u003eAllows precise dosing using a \u003cstrong data-start=\"3531\" data-end=\"3573\"\u003ereference mass with tolerance settings\u003c\/strong\u003e, ideal for powders, liquids, and granular materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"3628\" data-end=\"3648\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3649\" data-end=\"3732\"\u003eCompares measured samples to a reference mass and displays results as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"3734\" data-end=\"3748\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"3749\" data-end=\"3822\"\u003eAdds multiple weighings together to determine the total mass of mixtures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3824\" data-end=\"3842\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3843\" data-end=\"3956\"\u003eDetermines item quantity based on total weight and individual unit weight with \u003cstrong data-start=\"3922\" data-end=\"3955\"\u003eautomatic accuracy correction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3958\" data-end=\"3971\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3972\" data-end=\"4059\"\u003eCaptures the \u003cstrong data-start=\"3985\" data-end=\"4024\"\u003ehighest temporary measurement value\u003c\/strong\u003e during dynamic weighing processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u90ctf\" data-start=\"4061\" data-end=\"4075\"\u003eStatistics\u003c\/h3\u003e\n\u003cp data-start=\"4076\" data-end=\"4116\"\u003eProvides statistical analysis including:\u003c\/p\u003e\n\u003cul data-start=\"4118\" data-end=\"4224\"\u003e\n\u003cli data-section-id=\"tf72o5\" data-start=\"4118\" data-end=\"4148\"\u003e\n\u003cp data-start=\"4120\" data-end=\"4148\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"4149\" data-end=\"4166\"\u003e\n\u003cp data-start=\"4151\" data-end=\"4166\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"4167\" data-end=\"4189\"\u003e\n\u003cp data-start=\"4169\" data-end=\"4189\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"4190\" data-end=\"4202\"\u003e\n\u003cp data-start=\"4192\" data-end=\"4202\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"4203\" data-end=\"4224\"\u003e\n\u003cp data-start=\"4205\" data-end=\"4224\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4226\" data-end=\"4243\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4244\" data-end=\"4316\"\u003eVerifies whether sample weight falls within predefined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"4318\" data-end=\"4340\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4341\" data-end=\"4401\"\u003eAllows suspended weighing of irregular or oversized objects.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7ulzqj\" data-start=\"4403\" data-end=\"4428\"\u003eDensity Determination\u003c\/h3\u003e\n\u003cp data-start=\"4429\" data-end=\"4519\"\u003eSupports density measurement using \u003cstrong data-start=\"4464\" data-end=\"4489\"\u003eArchimedes’ principle\u003c\/strong\u003e with an optional density kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"4521\" data-end=\"4538\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"4539\" data-end=\"4624\"\u003eAllows generation of \u003cstrong data-start=\"4560\" data-end=\"4594\"\u003eGLP-compliant weighing reports\u003c\/strong\u003e for laboratory documentation.\u003c\/p\u003e\n\u003chr data-start=\"4626\" data-end=\"4629\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"4631\" data-end=\"4651\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"4653\" data-end=\"4715\"\u003eThe Radwag RS 2100.R2.M precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"4717\" data-end=\"4894\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"4717\" data-end=\"4748\"\u003e\n\u003cp data-start=\"4719\" data-end=\"4748\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14jqfya\" data-start=\"4749\" data-end=\"4775\"\u003e\n\u003cp data-start=\"4751\" data-end=\"4775\"\u003eChemical analysis labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8x7nhw\" data-start=\"4776\" data-end=\"4803\"\u003e\n\u003cp data-start=\"4778\" data-end=\"4803\"\u003eQuality control testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pi1uj2\" data-start=\"4804\" data-end=\"4833\"\u003e\n\u003cp data-start=\"4806\" data-end=\"4833\"\u003eMaterial science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y847d6\" data-start=\"4834\" data-end=\"4861\"\u003e\n\u003cp data-start=\"4836\" data-end=\"4861\"\u003eIndustrial laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"4862\" data-end=\"4894\"\u003e\n\u003cp data-start=\"4864\" data-end=\"4894\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4896\" data-end=\"4899\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4901\" data-end=\"4927\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4929\" data-end=\"4937\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4938\" data-end=\"4954\"\u003e\u003cstrong data-start=\"4938\" data-end=\"4954\"\u003eRS 2100.R2.M\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4956\" data-end=\"4984\"\u003ePart Number: \u003cstrong data-start=\"4969\" data-end=\"4984\"\u003eWL-212-0170\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4986\" data-end=\"4989\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"4991\" data-end=\"5013\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5015\" data-end=\"5044\"\u003eMaximum capacity\u003cbr data-start=\"5031\" data-end=\"5034\"\u003e\u003cstrong data-start=\"5034\" data-end=\"5044\"\u003e2100 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5046\" data-end=\"5071\"\u003eMinimum load\u003cbr data-start=\"5058\" data-end=\"5061\"\u003e\u003cstrong data-start=\"5061\" data-end=\"5071\"\u003e500 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5073\" data-end=\"5097\"\u003eReadability\u003cbr data-start=\"5084\" data-end=\"5087\"\u003e\u003cstrong data-start=\"5087\" data-end=\"5097\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5099\" data-end=\"5123\"\u003eTare range\u003cbr data-start=\"5109\" data-end=\"5112\"\u003e\u003cstrong data-start=\"5112\" data-end=\"5123\"\u003e−2100 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5125\" data-end=\"5128\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5130\" data-end=\"5140\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5142\" data-end=\"5175\"\u003eRepeatability (Max)\u003cbr data-start=\"5161\" data-end=\"5164\"\u003e\u003cstrong data-start=\"5164\" data-end=\"5175\"\u003e0.008 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5177\" data-end=\"5213\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5199\" data-end=\"5202\"\u003e\u003cstrong data-start=\"5202\" data-end=\"5213\"\u003e0.005 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5215\" data-end=\"5238\"\u003eLinearity\u003cbr data-start=\"5224\" data-end=\"5227\"\u003e\u003cstrong data-start=\"5227\" data-end=\"5238\"\u003e±0.02 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5240\" data-end=\"5276\"\u003eStabilization time\u003cbr data-start=\"5258\" data-end=\"5261\"\u003e\u003cstrong data-start=\"5261\" data-end=\"5276\"\u003e1.5 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5278\" data-end=\"5281\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"5283\" data-end=\"5295\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"5297\" data-end=\"5331\"\u003e\u003cstrong data-start=\"5297\" data-end=\"5331\"\u003eInternal automatic calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5333\" data-end=\"5336\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"5338\" data-end=\"5347\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"5349\" data-end=\"5372\"\u003e\u003cstrong data-start=\"5349\" data-end=\"5372\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5374\" data-end=\"5377\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"5379\" data-end=\"5398\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"5400\" data-end=\"5437\"\u003ePan dimensions\u003cbr data-start=\"5414\" data-end=\"5417\"\u003e\u003cstrong data-start=\"5417\" data-end=\"5437\"\u003e7.7 × 7.7 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5439\" data-end=\"5469\"\u003eMaterial\u003cbr data-start=\"5447\" data-end=\"5450\"\u003e\u003cstrong data-start=\"5450\" data-end=\"5469\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5471\" data-end=\"5474\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"5476\" data-end=\"5490\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"5492\" data-end=\"5517\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"5519\" data-end=\"5579\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"5519\" data-end=\"5534\"\u003e\n\u003cp data-start=\"5521\" data-end=\"5534\"\u003e\u003cstrong data-start=\"5521\" data-end=\"5534\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"5535\" data-end=\"5546\"\u003e\n\u003cp data-start=\"5537\" data-end=\"5546\"\u003e\u003cstrong data-start=\"5537\" data-end=\"5546\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"5547\" data-end=\"5558\"\u003e\n\u003cp data-start=\"5549\" data-end=\"5558\"\u003e\u003cstrong data-start=\"5549\" data-end=\"5558\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"5559\" data-end=\"5579\"\u003e\n\u003cp data-start=\"5561\" data-end=\"5579\"\u003e\u003cstrong data-start=\"5561\" data-end=\"5579\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5581\" data-end=\"5584\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"5586\" data-end=\"5612\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"5614\" data-end=\"5653\"\u003eOperating temperature\u003cbr data-start=\"5635\" data-end=\"5638\"\u003e\u003cstrong data-start=\"5638\" data-end=\"5653\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5655\" data-end=\"5708\"\u003eRelative humidity\u003cbr data-start=\"5672\" data-end=\"5675\"\u003e\u003cstrong data-start=\"5675\" data-end=\"5708\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5710\" data-end=\"5713\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"5715\" data-end=\"5735\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"5737\" data-end=\"5764\"\u003e\u003cstrong data-start=\"5737\" data-end=\"5764\"\u003e100 – 240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5766\" data-end=\"5769\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5771\" data-end=\"5792\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5794\" data-end=\"5840\"\u003ePackage dimensions\u003cbr data-start=\"5812\" data-end=\"5815\"\u003e\u003cstrong data-start=\"5815\" data-end=\"5840\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5842\" data-end=\"5867\"\u003eUnit weight\u003cbr data-start=\"5853\" data-end=\"5856\"\u003e\u003cstrong data-start=\"5856\" data-end=\"5867\"\u003e9.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5869\" data-end=\"5897\"\u003eShipping weight\u003cbr data-start=\"5884\" data-end=\"5887\"\u003e\u003cstrong data-start=\"5887\" data-end=\"5897\"\u003e13 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5899\" data-end=\"5902\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"5904\" data-end=\"5919\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"5921\" data-end=\"5939\"\u003e\u003cstrong data-start=\"5921\" data-end=\"5939\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5941\" data-end=\"5944\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5946\" data-end=\"5956\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5958\" data-end=\"5990\"\u003e\u003cstrong data-start=\"5958\" data-end=\"5990\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282596131138,"sku":null,"price":1329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/ps-r2-nowe_ps-2100-r2-m--wl-212-0170-_1.jpg?v=1773589077"},{"product_id":"across-international-as-120-r2-plus-radwag-120g-capacity-0-01mg-readability-o3-5-analytical-balance","title":"Across International AS 120.R2 PLUS Radwag 120g Capacity 0.01mg Readability ø3.5\" Analytical Balance","description":"\u003ch2 data-section-id=\"3i68pl\" data-start=\"390\" data-end=\"487\"\u003eUltra-High Precision Analytical Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"489\" data-end=\"927\"\u003eThe \u003cstrong data-start=\"493\" data-end=\"537\"\u003eRadwag AS 120.R2 PLUS Analytical Balance\u003c\/strong\u003e is a high-performance analytical weighing instrument designed for \u003cstrong data-start=\"604\" data-end=\"689\"\u003eultra-precise laboratory measurements with 0.01 mg readability and 120 g capacity\u003c\/strong\u003e. Part of the \u003cstrong data-start=\"703\" data-end=\"731\"\u003eSYNERGY LAB product line\u003c\/strong\u003e, the AS R2 PLUS series combines advanced mechanical design with intelligent data management and automation features to ensure \u003cstrong data-start=\"858\" data-end=\"926\"\u003emaximum measurement accuracy, reliability, and ease of operation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"929\" data-end=\"1299\"\u003eThe spacious weighing chamber and \u003cstrong data-start=\"963\" data-end=\"993\"\u003eergonomic open-door design\u003c\/strong\u003e provide convenient access to the weighing pan, allowing the use of laboratory glassware of various sizes. A new \u003cstrong data-start=\"1106\" data-end=\"1136\"\u003ealuminum base construction\u003c\/strong\u003e enhances weighing stability, while the \u003cstrong data-start=\"1176\" data-end=\"1197\"\u003eDual-CLICK system\u003c\/strong\u003e enables tool-free assembly and disassembly of the weighing chamber for easy cleaning and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1301\" data-end=\"1634\"\u003eThe balance includes \u003cstrong data-start=\"1322\" data-end=\"1355\"\u003eautomatic internal adjustment\u003c\/strong\u003e, which compensates for environmental changes such as temperature fluctuations to maintain precise measurement results. Additionally, the \u003cstrong data-start=\"1493\" data-end=\"1545\"\u003eantistatic coating on the weighing chamber glass\u003c\/strong\u003e reduces electrostatic interference, improving weighing accuracy for ultra-light samples.\u003c\/p\u003e\n\u003cp data-start=\"1636\" data-end=\"1838\"\u003eEquipped with \u003cstrong data-start=\"1650\" data-end=\"1738\"\u003emultiple communication interfaces including RS232, USB, Ethernet, and optional Wi-Fi\u003c\/strong\u003e, the AS 120.R2 PLUS easily integrates with laboratory information systems, printers, and computers.\u003c\/p\u003e\n\u003chr data-start=\"1840\" data-end=\"1843\"\u003e\n\u003ch1 data-section-id=\"1k5e88r\" data-start=\"1845\" data-end=\"1907\"\u003eKey Features of the Radwag AS 120.R2 PLUS Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"popisn\" data-start=\"1909\" data-end=\"1945\"\u003eUltra-High Precision Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1946\" data-end=\"2081\"\u003eProvides \u003cstrong data-start=\"1955\" data-end=\"2006\"\u003e0.01 mg readability with 120 g maximum capacity\u003c\/strong\u003e, ideal for analytical laboratory applications requiring extreme precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11yfrj5\" data-start=\"2083\" data-end=\"2112\"\u003eSpacious Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2113\" data-end=\"2220\"\u003eLarge weighing chamber and wide door clearance allow convenient handling of laboratory vessels and samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1felwie\" data-start=\"2222\" data-end=\"2256\"\u003eInternal Automatic Calibration\u003c\/h3\u003e\n\u003cp data-start=\"2257\" data-end=\"2376\"\u003eModern internal adjustment system automatically compensates for environmental changes to maintain measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kevx82\" data-start=\"2378\" data-end=\"2407\"\u003eAnti-Static Glass Coating\u003c\/h3\u003e\n\u003cp data-start=\"2408\" data-end=\"2514\"\u003eSpecial \u003cstrong data-start=\"2416\" data-end=\"2443\"\u003eantistatic pane coating\u003c\/strong\u003e reduces electrostatic interference that could affect weighing results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t8icjt\" data-start=\"2516\" data-end=\"2553\"\u003eErgonomic Mechanical Construction\u003c\/h3\u003e\n\u003cp data-start=\"2554\" data-end=\"2625\"\u003eNew \u003cstrong data-start=\"2558\" data-end=\"2582\"\u003ealuminum base design\u003c\/strong\u003e improves balance stability and durability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zywr7y\" data-start=\"2627\" data-end=\"2656\"\u003eDual-CLICK Chamber System\u003c\/h3\u003e\n\u003cp data-start=\"2657\" data-end=\"2752\"\u003eAllows \u003cstrong data-start=\"2664\" data-end=\"2702\"\u003etool-free removal and installation\u003c\/strong\u003e of weighing chamber components for fast cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3o394\" data-start=\"2754\" data-end=\"2780\"\u003eFront Levelling System\u003c\/h3\u003e\n\u003cp data-start=\"2781\" data-end=\"2882\"\u003eTwo-point levelling system located at the front of the balance simplifies setup and level adjustment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"2884\" data-end=\"2907\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"2908\" data-end=\"3010\"\u003eClear \u003cstrong data-start=\"2914\" data-end=\"2937\"\u003ebacklit LCD display\u003c\/strong\u003e provides easy viewing of measurement results and additional information.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"3012\" data-end=\"3037\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3038\" data-end=\"3071\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"3073\" data-end=\"3158\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"3073\" data-end=\"3088\"\u003e\n\u003cp data-start=\"3075\" data-end=\"3088\"\u003e\u003cstrong data-start=\"3075\" data-end=\"3088\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"3089\" data-end=\"3105\"\u003e\n\u003cp data-start=\"3091\" data-end=\"3105\"\u003e\u003cstrong data-start=\"3091\" data-end=\"3105\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"3106\" data-end=\"3122\"\u003e\n\u003cp data-start=\"3108\" data-end=\"3122\"\u003e\u003cstrong data-start=\"3108\" data-end=\"3122\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"3123\" data-end=\"3137\"\u003e\n\u003cp data-start=\"3125\" data-end=\"3137\"\u003e\u003cstrong data-start=\"3125\" data-end=\"3137\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"3138\" data-end=\"3158\"\u003e\n\u003cp data-start=\"3140\" data-end=\"3158\"\u003e\u003cstrong data-start=\"3140\" data-end=\"3158\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3160\" data-end=\"3237\"\u003eA front USB port allows easy connection of flash drives and external devices.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pgakg8\" data-start=\"3239\" data-end=\"3258\"\u003eDevice Security\u003c\/h3\u003e\n\u003cp data-start=\"3259\" data-end=\"3333\"\u003eIntegrated \u003cstrong data-start=\"3270\" data-end=\"3294\"\u003eKensington Lock slot\u003c\/strong\u003e protects the instrument against theft.\u003c\/p\u003e\n\u003chr data-start=\"3335\" data-end=\"3338\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"3340\" data-end=\"3375\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"3377\" data-end=\"3489\"\u003eThe AS R2 PLUS series includes an advanced internal data system supporting multiple users and product databases.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"3491\" data-end=\"3512\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"3514\" data-end=\"3707\"\u003e\n\u003cli data-section-id=\"117fjp8\" data-start=\"3514\" data-end=\"3547\"\u003e\n\u003cp data-start=\"3516\" data-end=\"3547\"\u003e\u003cstrong data-start=\"3516\" data-end=\"3530\"\u003eOperators:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d70vn1\" data-start=\"3548\" data-end=\"3585\"\u003e\n\u003cp data-start=\"3550\" data-end=\"3585\"\u003e\u003cstrong data-start=\"3550\" data-end=\"3563\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r9m2z4\" data-start=\"3586\" data-end=\"3623\"\u003e\n\u003cp data-start=\"3588\" data-end=\"3623\"\u003e\u003cstrong data-start=\"3588\" data-end=\"3602\"\u003eWeighings:\u003c\/strong\u003e up to 5000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"3624\" data-end=\"3660\"\u003e\n\u003cp data-start=\"3626\" data-end=\"3660\"\u003e\u003cstrong data-start=\"3626\" data-end=\"3636\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g878ze\" data-start=\"3661\" data-end=\"3707\"\u003e\n\u003cp data-start=\"3663\" data-end=\"3707\"\u003e\u003cstrong data-start=\"3663\" data-end=\"3680\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3709\" data-end=\"3725\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3727\" data-end=\"3850\"\u003eThe built-in \u003cstrong data-start=\"3740\" data-end=\"3790\"\u003eALIBI memory securely records weighing results\u003c\/strong\u003e, ensuring long-term traceability and regulatory compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o5p3it\" data-start=\"3852\" data-end=\"3871\"\u003eData Protection\u003c\/h3\u003e\n\u003cp data-start=\"3873\" data-end=\"3992\"\u003eAccess to stored data requires user authentication, allowing administrators to manage user permissions and data access.\u003c\/p\u003e\n\u003chr data-start=\"3994\" data-end=\"3997\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3999\" data-end=\"4028\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"4030\" data-end=\"4114\"\u003eThe AS 120.R2 PLUS analytical balance supports multiple professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"4116\" data-end=\"4128\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"4129\" data-end=\"4248\"\u003eAutomatic diagnostic system verifying \u003cstrong data-start=\"4167\" data-end=\"4212\"\u003erepeatability and metrological parameters\u003c\/strong\u003e based on real operating conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"4250\" data-end=\"4260\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"4261\" data-end=\"4373\"\u003eAllows precise dosing based on \u003cstrong data-start=\"4292\" data-end=\"4332\"\u003ereference mass with tolerance limits\u003c\/strong\u003e, ideal for powders and liquid materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4375\" data-end=\"4395\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4396\" data-end=\"4474\"\u003eCompares sample mass to a reference mass and displays results as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"4476\" data-end=\"4490\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"4491\" data-end=\"4567\"\u003eAdds multiple measurements together to determine the total mass of mixtures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4569\" data-end=\"4587\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4588\" data-end=\"4679\"\u003eCalculates item quantity based on known unit weight with \u003cstrong data-start=\"4645\" data-end=\"4678\"\u003eautomatic accuracy correction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"4681\" data-end=\"4694\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"4695\" data-end=\"4772\"\u003eCaptures the \u003cstrong data-start=\"4708\" data-end=\"4747\"\u003ehighest temporary measurement value\u003c\/strong\u003e during dynamic weighing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u90ctf\" data-start=\"4774\" data-end=\"4788\"\u003eStatistics\u003c\/h3\u003e\n\u003cp data-start=\"4789\" data-end=\"4829\"\u003eProvides statistical analysis including:\u003c\/p\u003e\n\u003cul data-start=\"4831\" data-end=\"4937\"\u003e\n\u003cli data-section-id=\"tf72o5\" data-start=\"4831\" data-end=\"4861\"\u003e\n\u003cp data-start=\"4833\" data-end=\"4861\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"4862\" data-end=\"4879\"\u003e\n\u003cp data-start=\"4864\" data-end=\"4879\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"4880\" data-end=\"4902\"\u003e\n\u003cp data-start=\"4882\" data-end=\"4902\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"4903\" data-end=\"4915\"\u003e\n\u003cp data-start=\"4905\" data-end=\"4915\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"4916\" data-end=\"4937\"\u003e\n\u003cp data-start=\"4918\" data-end=\"4937\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4939\" data-end=\"4956\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4957\" data-end=\"5033\"\u003eDetermines whether a sample weight falls within predefined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"5035\" data-end=\"5057\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5058\" data-end=\"5143\"\u003eAllows suspended weighing of irregular objects or materials with magnetic properties.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"5145\" data-end=\"5164\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5165\" data-end=\"5235\"\u003eMeasures weight of moving samples by averaging measurements over time.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7ulzqj\" data-start=\"5237\" data-end=\"5262\"\u003eDensity Determination\u003c\/h3\u003e\n\u003cp data-start=\"5263\" data-end=\"5365\"\u003eDetermines density of solids and liquids using \u003cstrong data-start=\"5310\" data-end=\"5335\"\u003eArchimedes’ principle\u003c\/strong\u003e with an optional density kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"5367\" data-end=\"5384\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"5385\" data-end=\"5453\"\u003eSupports \u003cstrong data-start=\"5394\" data-end=\"5452\"\u003eGood Laboratory Practice (GLP) compliant documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5455\" data-end=\"5458\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5460\" data-end=\"5480\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5482\" data-end=\"5547\"\u003eThe Radwag AS 120.R2 PLUS analytical balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5549\" data-end=\"5750\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"5549\" data-end=\"5580\"\u003e\n\u003cp data-start=\"5551\" data-end=\"5580\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"5581\" data-end=\"5615\"\u003e\n\u003cp data-start=\"5583\" data-end=\"5615\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"5616\" data-end=\"5648\"\u003e\n\u003cp data-start=\"5618\" data-end=\"5648\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5649\" data-end=\"5681\"\u003e\n\u003cp data-start=\"5651\" data-end=\"5681\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pi1uj2\" data-start=\"5682\" data-end=\"5711\"\u003e\n\u003cp data-start=\"5684\" data-end=\"5711\"\u003eMaterial science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x51em9\" data-start=\"5712\" data-end=\"5750\"\u003e\n\u003cp data-start=\"5714\" data-end=\"5750\"\u003eIndustrial analytical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5752\" data-end=\"5755\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5757\" data-end=\"5783\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5785\" data-end=\"5793\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5794\" data-end=\"5812\"\u003e\u003cstrong data-start=\"5794\" data-end=\"5812\"\u003eAS 120.R2 PLUS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5814\" data-end=\"5842\"\u003ePart Number: \u003cstrong data-start=\"5827\" data-end=\"5842\"\u003eWL-104-0191\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5844\" data-end=\"5847\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5849\" data-end=\"5871\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5873\" data-end=\"5901\"\u003eMaximum capacity\u003cbr data-start=\"5889\" data-end=\"5892\"\u003e\u003cstrong data-start=\"5892\" data-end=\"5901\"\u003e120 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5903\" data-end=\"5926\"\u003eMinimum load\u003cbr data-start=\"5915\" data-end=\"5918\"\u003e\u003cstrong data-start=\"5918\" data-end=\"5926\"\u003e1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5928\" data-end=\"5953\"\u003eReadability\u003cbr data-start=\"5939\" data-end=\"5942\"\u003e\u003cstrong data-start=\"5942\" data-end=\"5953\"\u003e0.01 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5955\" data-end=\"5978\"\u003eTare range\u003cbr data-start=\"5965\" data-end=\"5968\"\u003e\u003cstrong data-start=\"5968\" data-end=\"5978\"\u003e−120 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5980\" data-end=\"5983\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5985\" data-end=\"5995\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5997\" data-end=\"6034\"\u003eRepeatability (5% Max)\u003cbr data-start=\"6019\" data-end=\"6022\"\u003e\u003cstrong data-start=\"6022\" data-end=\"6034\"\u003e0.015 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6036\" data-end=\"6069\"\u003eRepeatability (Max)\u003cbr data-start=\"6055\" data-end=\"6058\"\u003e\u003cstrong data-start=\"6058\" data-end=\"6069\"\u003e0.04 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6071\" data-end=\"6119\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"6105\" data-end=\"6108\"\u003e\u003cstrong data-start=\"6108\" data-end=\"6119\"\u003e0.02 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6121\" data-end=\"6166\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6152\" data-end=\"6155\"\u003e\u003cstrong data-start=\"6155\" data-end=\"6166\"\u003e0.05 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6168\" data-end=\"6192\"\u003eLinearity\u003cbr data-start=\"6177\" data-end=\"6180\"\u003e\u003cstrong data-start=\"6180\" data-end=\"6192\"\u003e±0.07 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6194\" data-end=\"6228\"\u003eStabilization time\u003cbr data-start=\"6212\" data-end=\"6215\"\u003e\u003cstrong data-start=\"6215\" data-end=\"6228\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6230\" data-end=\"6233\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6235\" data-end=\"6258\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6260\" data-end=\"6301\"\u003eStandard minimum weight (USP)\u003cbr data-start=\"6289\" data-end=\"6292\"\u003e\u003cstrong data-start=\"6292\" data-end=\"6301\"\u003e30 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6303\" data-end=\"6353\"\u003eStandard minimum weight (U = 1%, k = 2)\u003cbr data-start=\"6342\" data-end=\"6345\"\u003e\u003cstrong data-start=\"6345\" data-end=\"6353\"\u003e3 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6355\" data-end=\"6358\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"6360\" data-end=\"6372\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"6374\" data-end=\"6408\"\u003e\u003cstrong data-start=\"6374\" data-end=\"6408\"\u003eInternal automatic calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6410\" data-end=\"6413\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"6415\" data-end=\"6436\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"6438\" data-end=\"6449\"\u003e\u003cstrong data-start=\"6438\" data-end=\"6449\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6451\" data-end=\"6454\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6456\" data-end=\"6465\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6467\" data-end=\"6490\"\u003e\u003cstrong data-start=\"6467\" data-end=\"6490\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6492\" data-end=\"6495\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6497\" data-end=\"6511\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6513\" data-end=\"6538\"\u003eDiameter\u003cbr data-start=\"6521\" data-end=\"6524\"\u003e\u003cstrong data-start=\"6524\" data-end=\"6538\"\u003e3.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6540\" data-end=\"6570\"\u003eMaterial\u003cbr data-start=\"6548\" data-end=\"6551\"\u003e\u003cstrong data-start=\"6551\" data-end=\"6570\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6572\" data-end=\"6575\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6577\" data-end=\"6591\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6593\" data-end=\"6618\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6620\" data-end=\"6680\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"6620\" data-end=\"6635\"\u003e\n\u003cp data-start=\"6622\" data-end=\"6635\"\u003e\u003cstrong data-start=\"6622\" data-end=\"6635\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6636\" data-end=\"6647\"\u003e\n\u003cp data-start=\"6638\" data-end=\"6647\"\u003e\u003cstrong data-start=\"6638\" data-end=\"6647\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6648\" data-end=\"6659\"\u003e\n\u003cp data-start=\"6650\" data-end=\"6659\"\u003e\u003cstrong data-start=\"6650\" data-end=\"6659\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"6660\" data-end=\"6680\"\u003e\n\u003cp data-start=\"6662\" data-end=\"6680\"\u003e\u003cstrong data-start=\"6662\" data-end=\"6680\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6682\" data-end=\"6685\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6687\" data-end=\"6707\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6709\" data-end=\"6736\"\u003e\u003cstrong data-start=\"6709\" data-end=\"6736\"\u003e100 – 240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6738\" data-end=\"6741\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6743\" data-end=\"6765\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6767\" data-end=\"6806\"\u003eOperating temperature\u003cbr data-start=\"6788\" data-end=\"6791\"\u003e\u003cstrong data-start=\"6791\" data-end=\"6806\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6808\" data-end=\"6811\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6813\" data-end=\"6834\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6836\" data-end=\"6884\"\u003ePackage dimensions\u003cbr data-start=\"6854\" data-end=\"6857\"\u003e\u003cstrong data-start=\"6857\" data-end=\"6884\"\u003e19.5 × 15.5 × 20 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6886\" data-end=\"6910\"\u003eUnit weight\u003cbr data-start=\"6897\" data-end=\"6900\"\u003e\u003cstrong data-start=\"6900\" data-end=\"6910\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6912\" data-end=\"6940\"\u003eShipping weight\u003cbr data-start=\"6927\" data-end=\"6930\"\u003e\u003cstrong data-start=\"6930\" data-end=\"6940\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6942\" data-end=\"6945\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"6947\" data-end=\"6962\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"6964\" data-end=\"6982\"\u003e\u003cstrong data-start=\"6964\" data-end=\"6982\"\u003eNTEP Certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6984\" data-end=\"6987\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"6989\" data-end=\"7010\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"7012\" data-end=\"7218\"\u003e\n\u003cli data-section-id=\"11ltq8n\" data-start=\"7012\" data-end=\"7060\"\u003e\n\u003cp data-start=\"7014\" data-end=\"7060\"\u003eRadwag AS 120.R2 PLUS Analytical Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g2t8jg\" data-start=\"7061\" data-end=\"7089\"\u003e\n\u003cp data-start=\"7063\" data-end=\"7089\"\u003eBalance Fabric Cover – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yfw4sv\" data-start=\"7090\" data-end=\"7121\"\u003e\n\u003cp data-start=\"7092\" data-end=\"7121\"\u003eUniversal Power Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbmtyj\" data-start=\"7122\" data-end=\"7142\"\u003e\n\u003cp data-start=\"7124\" data-end=\"7142\"\u003ePan Assembly – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1afvlpz\" data-start=\"7143\" data-end=\"7175\"\u003e\n\u003cp data-start=\"7145\" data-end=\"7175\"\u003ePan Draft Shields – 3 pieces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isa1dl\" data-start=\"7176\" data-end=\"7195\"\u003e\n\u003cp data-start=\"7178\" data-end=\"7195\"\u003eBalance Pad – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"7196\" data-end=\"7218\"\u003e\n\u003cp data-start=\"7198\" data-end=\"7218\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7220\" data-end=\"7223\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7225\" data-end=\"7235\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7237\" data-end=\"7269\"\u003e\u003cstrong data-start=\"7237\" data-end=\"7269\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282605568322,"sku":null,"price":3909.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/as_r2_plus_02_as-120-r2-plus--wl-104-0191-_1.jpg?v=1773589288"},{"product_id":"across-international-as-60-220-r2-plus-radwag-60g-capacity-0-01mg-readability-o3-5-analytical-balance","title":"Across International AS 60\/220.R2 PLUS Radwag 60g Capacity 0.01mg Readability ø3.5\" Analytical Balance","description":"\u003ch2 data-section-id=\"5msm64\" data-start=\"397\" data-end=\"484\"\u003eDual-Range Analytical Balance with Internal Calibration and Advanced Data Management\u003c\/h2\u003e\n\u003cp data-start=\"486\" data-end=\"955\"\u003eThe \u003cstrong data-start=\"490\" data-end=\"537\"\u003eRadwag AS 60\/220.R2 PLUS Analytical Balance\u003c\/strong\u003e is a high-precision laboratory weighing instrument from the \u003cstrong data-start=\"598\" data-end=\"620\"\u003eSYNERGY LAB series\u003c\/strong\u003e, designed to deliver exceptional accuracy, reliability, and ease of operation. Featuring \u003cstrong data-start=\"710\" data-end=\"744\"\u003edual-range weighing capability\u003c\/strong\u003e, this analytical balance provides \u003cstrong data-start=\"779\" data-end=\"848\"\u003e0.01 mg readability up to 60 g and 0.1 mg readability up to 220 g\u003c\/strong\u003e, making it ideal for laboratories that require ultra-precise measurements across multiple weighing ranges.\u003c\/p\u003e\n\u003cp data-start=\"957\" data-end=\"1451\"\u003eThe AS R2 PLUS series incorporates modern mechanical and electronic innovations that enhance stability, durability, and measurement accuracy. A spacious weighing chamber with wide door clearance allows easy access to the weighing pan and accommodates laboratory glassware of various sizes. The new \u003cstrong data-start=\"1255\" data-end=\"1285\"\u003ealuminum base construction\u003c\/strong\u003e provides enhanced stability, while the \u003cstrong data-start=\"1325\" data-end=\"1346\"\u003eDual-CLICK system\u003c\/strong\u003e allows tool-free assembly and removal of weighing chamber components for quick cleaning and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1453\" data-end=\"1815\"\u003eTo ensure accurate results even under changing environmental conditions, the balance features \u003cstrong data-start=\"1547\" data-end=\"1581\"\u003eautomatic internal calibration\u003c\/strong\u003e, which compensates for temperature fluctuations and time-related drift. Additionally, \u003cstrong data-start=\"1668\" data-end=\"1720\"\u003eantistatic coating on the weighing chamber glass\u003c\/strong\u003e minimizes electrostatic interference that could otherwise affect extremely small measurements.\u003c\/p\u003e\n\u003cp data-start=\"1817\" data-end=\"2016\"\u003eWith \u003cstrong data-start=\"1822\" data-end=\"1905\"\u003eadvanced connectivity options including RS232, USB-A, USB-B, and optional Wi-Fi\u003c\/strong\u003e, the AS 60\/220.R2 PLUS integrates seamlessly with laboratory computers, printers, and data management systems.\u003c\/p\u003e\n\u003chr data-start=\"2018\" data-end=\"2021\"\u003e\n\u003ch1 data-section-id=\"6ha1kh\" data-start=\"2023\" data-end=\"2088\"\u003eKey Features of the Radwag AS 60\/220.R2 PLUS Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"hl58ru\" data-start=\"2090\" data-end=\"2130\"\u003eDual-Range Ultra-Precise Measurement\u003c\/h3\u003e\n\u003cp data-start=\"2131\" data-end=\"2161\"\u003eOffers two measurement ranges:\u003c\/p\u003e\n\u003cul data-start=\"2163\" data-end=\"2239\"\u003e\n\u003cli data-section-id=\"1q7fv1p\" data-start=\"2163\" data-end=\"2200\"\u003e\n\u003cp data-start=\"2165\" data-end=\"2200\"\u003e\u003cstrong data-start=\"2165\" data-end=\"2200\"\u003e0–60 g with 0.01 mg readability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xpagn1\" data-start=\"2201\" data-end=\"2239\"\u003e\n\u003cp data-start=\"2203\" data-end=\"2239\"\u003e\u003cstrong data-start=\"2203\" data-end=\"2239\"\u003e60–220 g with 0.1 mg readability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2241\" data-end=\"2334\"\u003eThis dual-range capability provides both ultra-high precision and extended weighing capacity.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11yfrj5\" data-start=\"2336\" data-end=\"2365\"\u003eSpacious Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2366\" data-end=\"2475\"\u003eThe large weighing chamber and wide door opening allow convenient handling of laboratory vessels and samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u9y5ti\" data-start=\"2477\" data-end=\"2511\"\u003eAutomatic Internal Calibration\u003c\/h3\u003e\n\u003cp data-start=\"2512\" data-end=\"2631\"\u003eInternal adjustment automatically compensates for environmental changes, ensuring accurate and repeatable measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kevx82\" data-start=\"2633\" data-end=\"2662\"\u003eAnti-Static Glass Coating\u003c\/h3\u003e\n\u003cp data-start=\"2663\" data-end=\"2775\"\u003eSpecial antistatic pane coating reduces electrostatic interference that can affect microgram-level measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gf5gh2\" data-start=\"2777\" data-end=\"2808\"\u003eErgonomic Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"2809\" data-end=\"2913\"\u003eNew \u003cstrong data-start=\"2813\" data-end=\"2843\"\u003ealuminum base construction\u003c\/strong\u003e improves balance stability and durability during long-term operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zywr7y\" data-start=\"2915\" data-end=\"2944\"\u003eDual-CLICK Chamber System\u003c\/h3\u003e\n\u003cp data-start=\"2945\" data-end=\"3045\"\u003eTool-free assembly and disassembly of weighing chamber components for fast cleaning and maintenance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3o394\" data-start=\"3047\" data-end=\"3073\"\u003eFront Levelling System\u003c\/h3\u003e\n\u003cp data-start=\"3074\" data-end=\"3185\"\u003eSimplified \u003cstrong data-start=\"3085\" data-end=\"3114\"\u003etwo-point leveling system\u003c\/strong\u003e located at the front of the balance allows quick and precise leveling.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"3187\" data-end=\"3210\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"3211\" data-end=\"3316\"\u003eHigh-contrast \u003cstrong data-start=\"3225\" data-end=\"3248\"\u003ebacklit LCD display\u003c\/strong\u003e ensures clear presentation of weighing results and additional data.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"3318\" data-end=\"3343\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3344\" data-end=\"3377\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"3379\" data-end=\"3449\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"3379\" data-end=\"3394\"\u003e\n\u003cp data-start=\"3381\" data-end=\"3394\"\u003e\u003cstrong data-start=\"3381\" data-end=\"3394\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"3395\" data-end=\"3411\"\u003e\n\u003cp data-start=\"3397\" data-end=\"3411\"\u003e\u003cstrong data-start=\"3397\" data-end=\"3411\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"3412\" data-end=\"3428\"\u003e\n\u003cp data-start=\"3414\" data-end=\"3428\"\u003e\u003cstrong data-start=\"3414\" data-end=\"3428\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"3429\" data-end=\"3449\"\u003e\n\u003cp data-start=\"3431\" data-end=\"3449\"\u003e\u003cstrong data-start=\"3431\" data-end=\"3449\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3451\" data-end=\"3549\"\u003eA front USB port enables quick data transfer using flash drives or connection to external devices.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pgakg8\" data-start=\"3551\" data-end=\"3570\"\u003eDevice Security\u003c\/h3\u003e\n\u003cp data-start=\"3571\" data-end=\"3656\"\u003eThe balance includes a \u003cstrong data-start=\"3594\" data-end=\"3618\"\u003eKensington lock slot\u003c\/strong\u003e to protect the instrument from theft.\u003c\/p\u003e\n\u003chr data-start=\"3658\" data-end=\"3661\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"3663\" data-end=\"3698\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"3700\" data-end=\"3822\"\u003eThe AS R2 PLUS series features an advanced internal database system for managing users, products, and measurement records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"3824\" data-end=\"3845\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"3847\" data-end=\"4039\"\u003e\n\u003cli data-section-id=\"117fjp8\" data-start=\"3847\" data-end=\"3880\"\u003e\n\u003cp data-start=\"3849\" data-end=\"3880\"\u003e\u003cstrong data-start=\"3849\" data-end=\"3863\"\u003eOperators:\u003c\/strong\u003e up to 10 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d70vn1\" data-start=\"3881\" data-end=\"3918\"\u003e\n\u003cp data-start=\"3883\" data-end=\"3918\"\u003e\u003cstrong data-start=\"3883\" data-end=\"3896\"\u003eProducts:\u003c\/strong\u003e up to 1000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r9m2z4\" data-start=\"3919\" data-end=\"3956\"\u003e\n\u003cp data-start=\"3921\" data-end=\"3956\"\u003e\u003cstrong data-start=\"3921\" data-end=\"3935\"\u003eWeighings:\u003c\/strong\u003e up to 5000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"3957\" data-end=\"3993\"\u003e\n\u003cp data-start=\"3959\" data-end=\"3993\"\u003e\u003cstrong data-start=\"3959\" data-end=\"3969\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ev0zns\" data-start=\"3994\" data-end=\"4039\"\u003e\n\u003cp data-start=\"3996\" data-end=\"4039\"\u003e\u003cstrong data-start=\"3996\" data-end=\"4013\"\u003eALIBI memory:\u003c\/strong\u003e up to 100,000 weighings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"4041\" data-end=\"4057\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"4059\" data-end=\"4199\"\u003eThe built-in \u003cstrong data-start=\"4072\" data-end=\"4088\"\u003eALIBI memory\u003c\/strong\u003e securely records weighing data and ensures long-term traceability for laboratory documentation and compliance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o5p3it\" data-start=\"4201\" data-end=\"4220\"\u003eData Protection\u003c\/h3\u003e\n\u003cp data-start=\"4222\" data-end=\"4321\"\u003eUser authentication allows administrators to control access to stored data and measurement records.\u003c\/p\u003e\n\u003chr data-start=\"4323\" data-end=\"4326\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"4328\" data-end=\"4357\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"4359\" data-end=\"4446\"\u003eThe AS 60\/220.R2 PLUS analytical balance supports multiple professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"4448\" data-end=\"4460\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"4461\" data-end=\"4545\"\u003eAutomatic diagnostic system verifying metrological parameters such as repeatability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"4547\" data-end=\"4557\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"4558\" data-end=\"4636\"\u003eAllows precise dosing based on a reference mass with defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4638\" data-end=\"4658\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4659\" data-end=\"4726\"\u003eDisplays sample mass as a percentage relative to a reference value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"4728\" data-end=\"4742\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"4743\" data-end=\"4819\"\u003eAdds multiple measurements together to determine the total mass of mixtures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4821\" data-end=\"4839\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4840\" data-end=\"4927\"\u003eDetermines item quantity based on known unit weight with automatic accuracy correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"4929\" data-end=\"4942\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"4943\" data-end=\"5015\"\u003eCaptures the highest temporary weight value during dynamic measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u90ctf\" data-start=\"5017\" data-end=\"5031\"\u003eStatistics\u003c\/h3\u003e\n\u003cp data-start=\"5032\" data-end=\"5068\"\u003eProvides statistical data including:\u003c\/p\u003e\n\u003cul data-start=\"5070\" data-end=\"5176\"\u003e\n\u003cli data-section-id=\"tf72o5\" data-start=\"5070\" data-end=\"5100\"\u003e\n\u003cp data-start=\"5072\" data-end=\"5100\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"5101\" data-end=\"5118\"\u003e\n\u003cp data-start=\"5103\" data-end=\"5118\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"5119\" data-end=\"5141\"\u003e\n\u003cp data-start=\"5121\" data-end=\"5141\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"5142\" data-end=\"5154\"\u003e\n\u003cp data-start=\"5144\" data-end=\"5154\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"5155\" data-end=\"5176\"\u003e\n\u003cp data-start=\"5157\" data-end=\"5176\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"5178\" data-end=\"5195\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"5196\" data-end=\"5270\"\u003eVerifies whether a sample falls within predefined weight tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"5272\" data-end=\"5294\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5295\" data-end=\"5380\"\u003eAllows suspended weighing of irregular objects or materials with magnetic properties.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"5382\" data-end=\"5401\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5402\" data-end=\"5474\"\u003eDetermines weight of moving samples by averaging measurements over time.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7ulzqj\" data-start=\"5476\" data-end=\"5501\"\u003eDensity Determination\u003c\/h3\u003e\n\u003cp data-start=\"5502\" data-end=\"5625\"\u003eAllows determination of \u003cstrong data-start=\"5526\" data-end=\"5581\"\u003esolid or liquid density using Archimedes’ principle\u003c\/strong\u003e with an optional density determination kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"5627\" data-end=\"5644\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"5645\" data-end=\"5706\"\u003eSupports generation of \u003cstrong data-start=\"5668\" data-end=\"5705\"\u003eGLP-compliant measurement reports\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5708\" data-end=\"5711\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5713\" data-end=\"5733\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5735\" data-end=\"5803\"\u003eThe Radwag AS 60\/220.R2 PLUS analytical balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5805\" data-end=\"6006\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"5805\" data-end=\"5836\"\u003e\n\u003cp data-start=\"5807\" data-end=\"5836\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"5837\" data-end=\"5871\"\u003e\n\u003cp data-start=\"5839\" data-end=\"5871\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"5872\" data-end=\"5904\"\u003e\n\u003cp data-start=\"5874\" data-end=\"5904\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5905\" data-end=\"5937\"\u003e\n\u003cp data-start=\"5907\" data-end=\"5937\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pi1uj2\" data-start=\"5938\" data-end=\"5967\"\u003e\n\u003cp data-start=\"5940\" data-end=\"5967\"\u003eMaterial science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x51em9\" data-start=\"5968\" data-end=\"6006\"\u003e\n\u003cp data-start=\"5970\" data-end=\"6006\"\u003eIndustrial analytical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6008\" data-end=\"6011\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"6013\" data-end=\"6039\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"6041\" data-end=\"6049\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"6050\" data-end=\"6071\"\u003e\u003cstrong data-start=\"6050\" data-end=\"6071\"\u003eAS 60\/220.R2 PLUS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6073\" data-end=\"6101\"\u003ePart Number: \u003cstrong data-start=\"6086\" data-end=\"6101\"\u003eWL-104-1052\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6103\" data-end=\"6106\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"6108\" data-end=\"6130\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"6132\" data-end=\"6165\"\u003eMaximum capacity\u003cbr data-start=\"6148\" data-end=\"6151\"\u003e\u003cstrong data-start=\"6151\" data-end=\"6165\"\u003e60 \/ 220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6167\" data-end=\"6190\"\u003eMinimum load\u003cbr data-start=\"6179\" data-end=\"6182\"\u003e\u003cstrong data-start=\"6182\" data-end=\"6190\"\u003e1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6192\" data-end=\"6226\"\u003eReadability\u003cbr data-start=\"6203\" data-end=\"6206\"\u003e\u003cstrong data-start=\"6206\" data-end=\"6226\"\u003e0.01 mg \/ 0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6228\" data-end=\"6251\"\u003eTare range\u003cbr data-start=\"6238\" data-end=\"6241\"\u003e\u003cstrong data-start=\"6241\" data-end=\"6251\"\u003e−220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6253\" data-end=\"6256\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"6258\" data-end=\"6268\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"6270\" data-end=\"6307\"\u003eRepeatability (5% Max)\u003cbr data-start=\"6292\" data-end=\"6295\"\u003e\u003cstrong data-start=\"6295\" data-end=\"6307\"\u003e0.015 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6309\" data-end=\"6342\"\u003eRepeatability (Max)\u003cbr data-start=\"6328\" data-end=\"6331\"\u003e\u003cstrong data-start=\"6331\" data-end=\"6342\"\u003e0.08 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6344\" data-end=\"6392\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"6378\" data-end=\"6381\"\u003e\u003cstrong data-start=\"6381\" data-end=\"6392\"\u003e0.02 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6394\" data-end=\"6438\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6425\" data-end=\"6428\"\u003e\u003cstrong data-start=\"6428\" data-end=\"6438\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6440\" data-end=\"6471\"\u003eLinearity\u003cbr data-start=\"6449\" data-end=\"6452\"\u003e\u003cstrong data-start=\"6452\" data-end=\"6471\"\u003e±0.05 \/ ±0.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6473\" data-end=\"6507\"\u003eStabilization time\u003cbr data-start=\"6491\" data-end=\"6494\"\u003e\u003cstrong data-start=\"6494\" data-end=\"6507\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6509\" data-end=\"6512\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"6514\" data-end=\"6526\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"6528\" data-end=\"6562\"\u003e\u003cstrong data-start=\"6528\" data-end=\"6562\"\u003eInternal automatic calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6564\" data-end=\"6567\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"6569\" data-end=\"6590\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"6592\" data-end=\"6603\"\u003e\u003cstrong data-start=\"6592\" data-end=\"6603\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6605\" data-end=\"6608\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6610\" data-end=\"6619\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6621\" data-end=\"6644\"\u003e\u003cstrong data-start=\"6621\" data-end=\"6644\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6646\" data-end=\"6649\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6651\" data-end=\"6665\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6667\" data-end=\"6692\"\u003eDiameter\u003cbr data-start=\"6675\" data-end=\"6678\"\u003e\u003cstrong data-start=\"6678\" data-end=\"6692\"\u003e3.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6694\" data-end=\"6724\"\u003eMaterial\u003cbr data-start=\"6702\" data-end=\"6705\"\u003e\u003cstrong data-start=\"6705\" data-end=\"6724\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6726\" data-end=\"6729\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6731\" data-end=\"6745\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6747\" data-end=\"6772\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6774\" data-end=\"6834\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"6774\" data-end=\"6789\"\u003e\n\u003cp data-start=\"6776\" data-end=\"6789\"\u003e\u003cstrong data-start=\"6776\" data-end=\"6789\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6790\" data-end=\"6801\"\u003e\n\u003cp data-start=\"6792\" data-end=\"6801\"\u003e\u003cstrong data-start=\"6792\" data-end=\"6801\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6802\" data-end=\"6813\"\u003e\n\u003cp data-start=\"6804\" data-end=\"6813\"\u003e\u003cstrong data-start=\"6804\" data-end=\"6813\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"6814\" data-end=\"6834\"\u003e\n\u003cp data-start=\"6816\" data-end=\"6834\"\u003e\u003cstrong data-start=\"6816\" data-end=\"6834\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6836\" data-end=\"6839\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6841\" data-end=\"6861\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6863\" data-end=\"6888\"\u003e\u003cstrong data-start=\"6863\" data-end=\"6888\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6890\" data-end=\"6893\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6895\" data-end=\"6917\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6919\" data-end=\"6958\"\u003eOperating temperature\u003cbr data-start=\"6940\" data-end=\"6943\"\u003e\u003cstrong data-start=\"6943\" data-end=\"6958\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6960\" data-end=\"6963\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6965\" data-end=\"6986\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6988\" data-end=\"7036\"\u003ePackage dimensions\u003cbr data-start=\"7006\" data-end=\"7009\"\u003e\u003cstrong data-start=\"7009\" data-end=\"7036\"\u003e19.5 × 15.5 × 20 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7038\" data-end=\"7062\"\u003eUnit weight\u003cbr data-start=\"7049\" data-end=\"7052\"\u003e\u003cstrong data-start=\"7052\" data-end=\"7062\"\u003e12 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7064\" data-end=\"7092\"\u003eShipping weight\u003cbr data-start=\"7079\" data-end=\"7082\"\u003e\u003cstrong data-start=\"7082\" data-end=\"7092\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7094\" data-end=\"7097\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7099\" data-end=\"7109\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7111\" data-end=\"7143\"\u003e\u003cstrong data-start=\"7111\" data-end=\"7143\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282607763778,"sku":null,"price":2997.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/as_r2_plus_02_as-60220-r2-plus--wl-104-1052-_1.jpg?v=1773589488"},{"product_id":"across-international-wtc-600-radwag-600g-capacity-0-01g-readability-5x5-precision-balance","title":"Across International WTC 600 Radwag 600g Capacity 0.01g Readability 5x5\" Precision Balance","description":"\u003ch2 data-section-id=\"qqaluk\" data-start=\"361\" data-end=\"439\"\u003eCompact Laboratory Precision Balance with Internal Battery and ALIBI Memory\u003c\/h2\u003e\n\u003cp data-start=\"441\" data-end=\"800\"\u003eThe \u003cstrong data-start=\"445\" data-end=\"481\"\u003eRadwag WTC 600 Precision Balance\u003c\/strong\u003e is a reliable laboratory weighing instrument designed for \u003cstrong data-start=\"540\" data-end=\"607\"\u003eaccurate mass determination up to 600 g with 0.01 g readability\u003c\/strong\u003e. Built for laboratory environments, this compact precision balance delivers fast, stable measurements while maintaining excellent portability thanks to its \u003cstrong data-start=\"764\" data-end=\"799\"\u003eintegrated rechargeable battery\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"802\" data-end=\"1132\"\u003eThe balance features a \u003cstrong data-start=\"825\" data-end=\"889\"\u003estainless steel weighing pan and a clear backlit LCD display\u003c\/strong\u003e, ensuring accurate measurements and easy readability in various laboratory conditions. With \u003cstrong data-start=\"982\" data-end=\"1024\"\u003eRS232 and USB communication interfaces\u003c\/strong\u003e, the WTC 600 can easily connect to printers, computers, USB drives, and laboratory data management systems.\u003c\/p\u003e\n\u003cp data-start=\"1134\" data-end=\"1527\"\u003eAn integrated \u003cstrong data-start=\"1148\" data-end=\"1219\"\u003eALIBI memory system stores up to 100,000 measurements automatically\u003c\/strong\u003e, ensuring traceability and compliance with laboratory documentation standards. Combined with advanced weighing functions such as \u003cstrong data-start=\"1349\" data-end=\"1419\"\u003echeckweighing, percent weighing, parts counting, and GLP reporting\u003c\/strong\u003e, the WTC 600 is ideal for laboratories, research environments, and industrial quality control applications.\u003c\/p\u003e\n\u003chr data-start=\"1529\" data-end=\"1532\"\u003e\n\u003ch1 data-section-id=\"1t4gukm\" data-start=\"1534\" data-end=\"1588\"\u003eKey Features of the Radwag WTC 600 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"yfk4p3\" data-start=\"1590\" data-end=\"1622\"\u003eAccurate Laboratory Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1623\" data-end=\"1720\"\u003eProvides \u003cstrong data-start=\"1632\" data-end=\"1674\"\u003e600 g capacity with 0.01 g readability\u003c\/strong\u003e, ideal for routine laboratory weighing tasks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rynjla\" data-start=\"1722\" data-end=\"1754\"\u003eStainless Steel Weighing Pan\u003c\/h3\u003e\n\u003cp data-start=\"1755\" data-end=\"1858\"\u003eDurable \u003cstrong data-start=\"1763\" data-end=\"1811\"\u003e5 × 5 inch stainless steel weighing platform\u003c\/strong\u003e offers corrosion resistance and easy cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"1860\" data-end=\"1883\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1884\" data-end=\"1971\"\u003eHigh-contrast \u003cstrong data-start=\"1898\" data-end=\"1920\"\u003ebacklit LCD screen\u003c\/strong\u003e ensures clear presentation of measurement results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ype4r\" data-start=\"1973\" data-end=\"2006\"\u003eInternal Rechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"2007\" data-end=\"2132\"\u003eIntegrated battery enables \u003cstrong data-start=\"2034\" data-end=\"2065\"\u003eup to 15 hours of operation\u003c\/strong\u003e, allowing the balance to operate where mains power is unavailable.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"2134\" data-end=\"2159\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2160\" data-end=\"2193\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2195\" data-end=\"2274\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"2195\" data-end=\"2206\"\u003e\n\u003cp data-start=\"2197\" data-end=\"2206\"\u003e\u003cstrong data-start=\"2197\" data-end=\"2206\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2207\" data-end=\"2223\"\u003e\n\u003cp data-start=\"2209\" data-end=\"2223\"\u003e\u003cstrong data-start=\"2209\" data-end=\"2223\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2224\" data-end=\"2240\"\u003e\n\u003cp data-start=\"2226\" data-end=\"2240\"\u003e\u003cstrong data-start=\"2226\" data-end=\"2240\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cq3jcv\" data-start=\"2241\" data-end=\"2274\"\u003e\n\u003cp data-start=\"2243\" data-end=\"2274\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2274\"\u003eOptional Wi-Fi connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2276\" data-end=\"2363\"\u003eThese allow easy integration with printers, computers, and laboratory software systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1bl50s\" data-start=\"2365\" data-end=\"2384\"\u003eReal-Time Clock\u003c\/h3\u003e\n\u003cp data-start=\"2385\" data-end=\"2482\"\u003eBuilt-in clock records \u003cstrong data-start=\"2408\" data-end=\"2446\"\u003edate and time for each measurement\u003c\/strong\u003e, supporting traceable data records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13izteo\" data-start=\"2484\" data-end=\"2506\"\u003eALIBI Data Storage\u003c\/h3\u003e\n\u003cp data-start=\"2507\" data-end=\"2643\"\u003eInternal \u003cstrong data-start=\"2516\" data-end=\"2580\"\u003eALIBI memory stores up to 100,000 measurements automatically\u003c\/strong\u003e, providing secure data recording for laboratory documentation.\u003c\/p\u003e\n\u003chr data-start=\"2645\" data-end=\"2648\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"2650\" data-end=\"2679\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"2681\" data-end=\"2805\"\u003eThe WTC series precision balances include a range of professional weighing modes suitable for laboratory and industrial use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlrqzv\" data-start=\"2807\" data-end=\"2845\"\u003eCheckweighing (Plus\/Minus Control)\u003c\/h3\u003e\n\u003cp data-start=\"2846\" data-end=\"2996\"\u003eAllows verification of sample mass against predefined \u003cstrong data-start=\"2900\" data-end=\"2934\"\u003eminimum and maximum thresholds\u003c\/strong\u003e, with results displayed visually using a bar graph indicator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"2998\" data-end=\"3018\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3019\" data-end=\"3099\"\u003eCompares sample mass with a reference mass and displays results as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3101\" data-end=\"3119\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3120\" data-end=\"3231\"\u003eDetermines item quantity based on total mass and individual item weight with \u003cstrong data-start=\"3197\" data-end=\"3230\"\u003eautomatic accuracy correction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3233\" data-end=\"3246\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3247\" data-end=\"3331\"\u003eCaptures the \u003cstrong data-start=\"3260\" data-end=\"3296\"\u003ehighest temporary weight reading\u003c\/strong\u003e during dynamic weighing processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kvw8o3\" data-start=\"3333\" data-end=\"3351\"\u003eGLP Procedures\u003c\/h3\u003e\n\u003cp data-start=\"3352\" data-end=\"3477\"\u003eSupports \u003cstrong data-start=\"3361\" data-end=\"3409\"\u003eGood Laboratory Practice (GLP) documentation\u003c\/strong\u003e, allowing measurements to be recorded and printed for traceability.\u003c\/p\u003e\n\u003chr data-start=\"3479\" data-end=\"3482\"\u003e\n\u003ch1 data-section-id=\"1gt51nx\" data-start=\"3484\" data-end=\"3505\"\u003eALIBI Memory System\u003c\/h1\u003e\n\u003cp data-start=\"3507\" data-end=\"3618\"\u003eThe built-in \u003cstrong data-start=\"3520\" data-end=\"3536\"\u003eALIBI memory\u003c\/strong\u003e automatically records measurement data without requiring additional user actions.\u003c\/p\u003e\n\u003cp data-start=\"3620\" data-end=\"3641\"\u003eStored data includes:\u003c\/p\u003e\n\u003cul data-start=\"3643\" data-end=\"3757\"\u003e\n\u003cli data-section-id=\"1is1fee\" data-start=\"3643\" data-end=\"3663\"\u003e\n\u003cp data-start=\"3645\" data-end=\"3663\"\u003eMeasurement date\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t9zz2v\" data-start=\"3664\" data-end=\"3684\"\u003e\n\u003cp data-start=\"3666\" data-end=\"3684\"\u003eMeasurement time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u6k41k\" data-start=\"3685\" data-end=\"3702\"\u003e\n\u003cp data-start=\"3687\" data-end=\"3702\"\u003eMeasured mass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rdpcox\" data-start=\"3703\" data-end=\"3717\"\u003e\n\u003cp data-start=\"3705\" data-end=\"3717\"\u003eTare value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z378kg\" data-start=\"3718\" data-end=\"3740\"\u003e\n\u003cp data-start=\"3720\" data-end=\"3740\"\u003eLogged-in operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h4tn38\" data-start=\"3741\" data-end=\"3757\"\u003e\n\u003cp data-start=\"3743\" data-end=\"3757\"\u003eProduct name\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3759\" data-end=\"4018\"\u003eThe memory stores \u003cstrong data-start=\"3777\" data-end=\"3807\"\u003eup to 100,000 measurements\u003c\/strong\u003e using a continuous loop system. When the memory reaches capacity, the oldest measurement is automatically replaced by the newest entry. Stored records cannot be deleted manually, ensuring secure data integrity.\u003c\/p\u003e\n\u003chr data-start=\"4020\" data-end=\"4023\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"4025\" data-end=\"4045\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"4047\" data-end=\"4104\"\u003eThe Radwag WTC 600 precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"4106\" data-end=\"4284\"\u003e\n\u003cli data-section-id=\"aigv49\" data-start=\"4106\" data-end=\"4131\"\u003e\n\u003cp data-start=\"4108\" data-end=\"4131\"\u003eChemical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"4132\" data-end=\"4163\"\u003e\n\u003cp data-start=\"4134\" data-end=\"4163\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1munbrc\" data-start=\"4164\" data-end=\"4190\"\u003e\n\u003cp data-start=\"4166\" data-end=\"4190\"\u003eAcademic research labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fivdhh\" data-start=\"4191\" data-end=\"4221\"\u003e\n\u003cp data-start=\"4193\" data-end=\"4221\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1apzouo\" data-start=\"4222\" data-end=\"4255\"\u003e\n\u003cp data-start=\"4224\" data-end=\"4255\"\u003eMaterial testing laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"46ykkq\" data-start=\"4256\" data-end=\"4284\"\u003e\n\u003cp data-start=\"4258\" data-end=\"4284\"\u003eEducational laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4286\" data-end=\"4289\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"4291\" data-end=\"4317\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"4319\" data-end=\"4327\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"4328\" data-end=\"4339\"\u003e\u003cstrong data-start=\"4328\" data-end=\"4339\"\u003eWTC 600\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4341\" data-end=\"4369\"\u003ePart Number: \u003cstrong data-start=\"4354\" data-end=\"4369\"\u003eWL-210-0003\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4371\" data-end=\"4374\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"4376\" data-end=\"4398\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"4400\" data-end=\"4428\"\u003eMaximum capacity\u003cbr data-start=\"4416\" data-end=\"4419\"\u003e\u003cstrong data-start=\"4419\" data-end=\"4428\"\u003e600 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4430\" data-end=\"4454\"\u003eMinimum load\u003cbr data-start=\"4442\" data-end=\"4445\"\u003e\u003cstrong data-start=\"4445\" data-end=\"4454\"\u003e0.5 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4456\" data-end=\"4480\"\u003eReadability\u003cbr data-start=\"4467\" data-end=\"4470\"\u003e\u003cstrong data-start=\"4470\" data-end=\"4480\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4482\" data-end=\"4505\"\u003eTare range\u003cbr data-start=\"4492\" data-end=\"4495\"\u003e\u003cstrong data-start=\"4495\" data-end=\"4505\"\u003e−600 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4507\" data-end=\"4510\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4512\" data-end=\"4522\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4524\" data-end=\"4550\"\u003eRepeatability\u003cbr data-start=\"4537\" data-end=\"4540\"\u003e\u003cstrong data-start=\"4540\" data-end=\"4550\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4552\" data-end=\"4575\"\u003eLinearity\u003cbr data-start=\"4561\" data-end=\"4564\"\u003e\u003cstrong data-start=\"4564\" data-end=\"4575\"\u003e±0.02 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4577\" data-end=\"4611\"\u003eStabilization time\u003cbr data-start=\"4595\" data-end=\"4598\"\u003e\u003cstrong data-start=\"4598\" data-end=\"4611\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4613\" data-end=\"4616\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4618\" data-end=\"4627\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4629\" data-end=\"4652\"\u003e\u003cstrong data-start=\"4629\" data-end=\"4652\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4654\" data-end=\"4657\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4659\" data-end=\"4678\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4680\" data-end=\"4709\"\u003eDimensions\u003cbr data-start=\"4690\" data-end=\"4693\"\u003e\u003cstrong data-start=\"4693\" data-end=\"4709\"\u003e5 × 5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4711\" data-end=\"4741\"\u003eMaterial\u003cbr data-start=\"4719\" data-end=\"4722\"\u003e\u003cstrong data-start=\"4722\" data-end=\"4741\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4743\" data-end=\"4746\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4748\" data-end=\"4762\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4764\" data-end=\"4789\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4791\" data-end=\"4847\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"4791\" data-end=\"4802\"\u003e\n\u003cp data-start=\"4793\" data-end=\"4802\"\u003e\u003cstrong data-start=\"4793\" data-end=\"4802\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4803\" data-end=\"4814\"\u003e\n\u003cp data-start=\"4805\" data-end=\"4814\"\u003e\u003cstrong data-start=\"4805\" data-end=\"4814\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4815\" data-end=\"4826\"\u003e\n\u003cp data-start=\"4817\" data-end=\"4826\"\u003e\u003cstrong data-start=\"4817\" data-end=\"4826\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4827\" data-end=\"4847\"\u003e\n\u003cp data-start=\"4829\" data-end=\"4847\"\u003e\u003cstrong data-start=\"4829\" data-end=\"4847\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4849\" data-end=\"4852\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4854\" data-end=\"4874\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4876\" data-end=\"4901\"\u003e\u003cstrong data-start=\"4876\" data-end=\"4901\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4903\" data-end=\"4938\"\u003eMaximum power consumption\u003cbr data-start=\"4928\" data-end=\"4931\"\u003e\u003cstrong data-start=\"4931\" data-end=\"4938\"\u003e6 W\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4940\" data-end=\"4985\"\u003eBattery operation time\u003cbr data-start=\"4962\" data-end=\"4965\"\u003e\u003cstrong data-start=\"4965\" data-end=\"4985\"\u003eApprox. 15 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4987\" data-end=\"4990\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4992\" data-end=\"5018\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"5020\" data-end=\"5059\"\u003eOperating temperature\u003cbr data-start=\"5041\" data-end=\"5044\"\u003e\u003cstrong data-start=\"5044\" data-end=\"5059\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5061\" data-end=\"5088\"\u003eProtection class\u003cbr data-start=\"5077\" data-end=\"5080\"\u003e\u003cstrong data-start=\"5080\" data-end=\"5088\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5090\" data-end=\"5093\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"5095\" data-end=\"5116\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"5118\" data-end=\"5162\"\u003ePackage dimensions\u003cbr data-start=\"5136\" data-end=\"5139\"\u003e\u003cstrong data-start=\"5139\" data-end=\"5162\"\u003e13 × 9 × 5.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5164\" data-end=\"5187\"\u003eUnit weight\u003cbr data-start=\"5175\" data-end=\"5178\"\u003e\u003cstrong data-start=\"5178\" data-end=\"5187\"\u003e3 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5189\" data-end=\"5218\"\u003eShipping weight\u003cbr data-start=\"5204\" data-end=\"5207\"\u003e\u003cstrong data-start=\"5207\" data-end=\"5218\"\u003e4.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5220\" data-end=\"5223\"\u003e\n\u003ch1 data-section-id=\"1kgrdy6\" data-start=\"5225\" data-end=\"5240\"\u003eCertification\u003c\/h1\u003e\n\u003cp data-start=\"5242\" data-end=\"5274\"\u003e\u003cstrong data-start=\"5242\" data-end=\"5274\"\u003eNTEP Certification: Optional\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5276\" data-end=\"5279\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5281\" data-end=\"5291\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5293\" data-end=\"5325\"\u003e\u003cstrong data-start=\"5293\" data-end=\"5325\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282609697090,"sku":null,"price":488.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/wtc_wtc-600--wl-210-0003-1.jpg?v=1773589766"},{"product_id":"across-international-wlc-20-a2-radwag-20kg-capacity-0-1g-readability-8x8-precision-balance","title":"Across International WLC 20\/A2 Radwag 20kg Capacity 0.1g Readability 8x8\" Precision Balance","description":"\u003ch2 data-section-id=\"9rr9s2\" data-start=\"308\" data-end=\"381\"\u003eHigh-Capacity Precision Balance for Laboratory and Industrial Weighing\u003c\/h2\u003e\n\u003cp data-start=\"383\" data-end=\"741\"\u003eThe \u003cstrong data-start=\"387\" data-end=\"425\"\u003eRadwag WLC 20\/A2 Precision Balance\u003c\/strong\u003e is a versatile laboratory and industrial weighing solution designed for \u003cstrong data-start=\"498\" data-end=\"573\"\u003efast and accurate mass determination up to 20 kg with 0.1 g readability\u003c\/strong\u003e. Built for demanding laboratory and production environments, the WLC 20\/A2 combines precision measurement with durable construction and advanced connectivity features.\u003c\/p\u003e\n\u003cp data-start=\"743\" data-end=\"1039\"\u003eEquipped with a \u003cstrong data-start=\"759\" data-end=\"817\"\u003estainless steel weighing pan and a backlit LCD display\u003c\/strong\u003e, the balance ensures clear and reliable weighing results. The integrated \u003cstrong data-start=\"891\" data-end=\"959\"\u003erechargeable internal battery allows up to 15 hours of operation\u003c\/strong\u003e, making the device suitable for locations without direct access to mains power.\u003c\/p\u003e\n\u003cp data-start=\"1041\" data-end=\"1329\"\u003eWith \u003cstrong data-start=\"1046\" data-end=\"1088\"\u003eRS232 and USB communication interfaces\u003c\/strong\u003e, the WLC 20\/A2 easily integrates with printers, computers, USB drives, and external displays. Additionally, the balance features \u003cstrong data-start=\"1218\" data-end=\"1268\"\u003ereal-time clock functionality and ALIBI memory\u003c\/strong\u003e, providing secure data storage and measurement traceability.\u003c\/p\u003e\n\u003chr data-start=\"1331\" data-end=\"1334\"\u003e\n\u003ch1 data-section-id=\"1bmffo6\" data-start=\"1336\" data-end=\"1392\"\u003eKey Features of the Radwag WLC 20\/A2 Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"7e8g86\" data-start=\"1394\" data-end=\"1431\"\u003eHigh-Capacity Laboratory Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1432\" data-end=\"1578\"\u003eOffers \u003cstrong data-start=\"1439\" data-end=\"1488\"\u003e20 kg maximum capacity with 0.1 g readability\u003c\/strong\u003e, ideal for weighing larger laboratory samples, industrial components, and bulk materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1o65ju6\" data-start=\"1580\" data-end=\"1617\"\u003eStainless Steel Weighing Platform\u003c\/h3\u003e\n\u003cp data-start=\"1618\" data-end=\"1722\"\u003eDurable \u003cstrong data-start=\"1626\" data-end=\"1673\"\u003e7.7 × 7.7 inch stainless steel weighing pan\u003c\/strong\u003e provides corrosion resistance and easy cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t1dhsd\" data-start=\"1724\" data-end=\"1747\"\u003eBacklit LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"1748\" data-end=\"1857\"\u003eClear \u003cstrong data-start=\"1754\" data-end=\"1776\"\u003ebacklit LCD screen\u003c\/strong\u003e ensures excellent visibility of weighing results in various lighting conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ype4r\" data-start=\"1859\" data-end=\"1892\"\u003eInternal Rechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"1893\" data-end=\"1996\"\u003eBuilt-in \u003cstrong data-start=\"1902\" data-end=\"1933\"\u003eSLA 6V rechargeable battery\u003c\/strong\u003e allows up to \u003cstrong data-start=\"1947\" data-end=\"1972\"\u003e15 hours of operation\u003c\/strong\u003e without external power.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"1998\" data-end=\"2023\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2024\" data-end=\"2057\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"2059\" data-end=\"2142\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"2059\" data-end=\"2074\"\u003e\n\u003cp data-start=\"2061\" data-end=\"2074\"\u003e\u003cstrong data-start=\"2061\" data-end=\"2074\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"2075\" data-end=\"2091\"\u003e\n\u003cp data-start=\"2077\" data-end=\"2091\"\u003e\u003cstrong data-start=\"2077\" data-end=\"2091\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"2092\" data-end=\"2108\"\u003e\n\u003cp data-start=\"2094\" data-end=\"2108\"\u003e\u003cstrong data-start=\"2094\" data-end=\"2108\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cq3jcv\" data-start=\"2109\" data-end=\"2142\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2142\"\u003e\u003cstrong data-start=\"2111\" data-end=\"2142\"\u003eOptional Wi-Fi connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2144\" data-end=\"2234\"\u003eThese allow integration with printers, computers, USB flash drives, and external displays.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9kus6c\" data-start=\"2236\" data-end=\"2270\"\u003eALIBI Memory \u0026amp; Real-Time Clock\u003c\/h3\u003e\n\u003cp data-start=\"2271\" data-end=\"2408\"\u003eIntegrated \u003cstrong data-start=\"2282\" data-end=\"2343\"\u003eALIBI memory system stores measurement data automatically\u003c\/strong\u003e, ensuring traceability and documentation of weighing operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9cp72p\" data-start=\"2410\" data-end=\"2445\"\u003eOptional Industrial Integration\u003c\/h3\u003e\n\u003cp data-start=\"2446\" data-end=\"2580\"\u003eThe WLC series balances can optionally be equipped with \u003cstrong data-start=\"2502\" data-end=\"2529\"\u003e4 IN \/ 4 OUT interfaces\u003c\/strong\u003e for automation and industrial process integration.\u003c\/p\u003e\n\u003chr data-start=\"2582\" data-end=\"2585\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"2587\" data-end=\"2616\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"2618\" data-end=\"2744\"\u003eThe WLC 20\/A2 precision balance includes several professional weighing modes designed for laboratory and industrial workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rlrqzv\" data-start=\"2746\" data-end=\"2784\"\u003eCheckweighing (Plus\/Minus Control)\u003c\/h3\u003e\n\u003cp data-start=\"2785\" data-end=\"2934\"\u003eVerifies whether a sample mass falls within predefined \u003cstrong data-start=\"2840\" data-end=\"2874\"\u003eminimum and maximum thresholds\u003c\/strong\u003e, with results displayed visually via a bar graph indicator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"2936\" data-end=\"2956\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"2957\" data-end=\"3051\"\u003eCompares measured samples with a reference mass standard and displays results as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nc2x9z\" data-start=\"3053\" data-end=\"3067\"\u003eTotalizing\u003c\/h3\u003e\n\u003cp data-start=\"3068\" data-end=\"3155\"\u003eAdds multiple measurements together to determine the total mass of mixtures or batches.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3157\" data-end=\"3175\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3176\" data-end=\"3330\"\u003eCalculates the quantity of items based on total weight and individual item mass. Includes \u003cstrong data-start=\"3266\" data-end=\"3299\"\u003eautomatic accuracy correction\u003c\/strong\u003e to improve counting precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t1527q\" data-start=\"3332\" data-end=\"3345\"\u003ePeak Hold\u003c\/h3\u003e\n\u003cp data-start=\"3346\" data-end=\"3440\"\u003eCaptures and holds the \u003cstrong data-start=\"3369\" data-end=\"3405\"\u003ehighest temporary weight reading\u003c\/strong\u003e during dynamic weighing processes.\u003c\/p\u003e\n\u003chr data-start=\"3442\" data-end=\"3445\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3447\" data-end=\"3467\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3469\" data-end=\"3528\"\u003eThe Radwag WLC 20\/A2 precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3530\" data-end=\"3765\"\u003e\n\u003cli data-section-id=\"4dd1au\" data-start=\"3530\" data-end=\"3566\"\u003e\n\u003cp data-start=\"3532\" data-end=\"3566\"\u003eLaboratory weighing applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fivdhh\" data-start=\"3567\" data-end=\"3597\"\u003e\n\u003cp data-start=\"3569\" data-end=\"3597\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"og9uu2\" data-start=\"3598\" data-end=\"3640\"\u003e\n\u003cp data-start=\"3600\" data-end=\"3640\"\u003eManufacturing and packaging operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"j1l0jp\" data-start=\"3641\" data-end=\"3685\"\u003e\n\u003cp data-start=\"3643\" data-end=\"3685\"\u003eChemical and pharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n0axfw\" data-start=\"3686\" data-end=\"3723\"\u003e\n\u003cp data-start=\"3688\" data-end=\"3723\"\u003eParts counting and batch weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13c49rs\" data-start=\"3724\" data-end=\"3765\"\u003e\n\u003cp data-start=\"3726\" data-end=\"3765\"\u003eEducational and research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3767\" data-end=\"3770\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3772\" data-end=\"3798\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3800\" data-end=\"3808\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3809\" data-end=\"3822\"\u003e\u003cstrong data-start=\"3809\" data-end=\"3822\"\u003eWLC 20\/A2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3824\" data-end=\"3852\"\u003ePart Number: \u003cstrong data-start=\"3837\" data-end=\"3852\"\u003eWL-206-0022\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3854\" data-end=\"3857\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"3859\" data-end=\"3881\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"3883\" data-end=\"3911\"\u003eMaximum capacity\u003cbr data-start=\"3899\" data-end=\"3902\"\u003e\u003cstrong data-start=\"3902\" data-end=\"3911\"\u003e20 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3913\" data-end=\"3936\"\u003eReadability\u003cbr data-start=\"3924\" data-end=\"3927\"\u003e\u003cstrong data-start=\"3927\" data-end=\"3936\"\u003e0.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3938\" data-end=\"3961\"\u003eTare range\u003cbr data-start=\"3948\" data-end=\"3951\"\u003e\u003cstrong data-start=\"3951\" data-end=\"3961\"\u003e−20 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3963\" data-end=\"3966\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"3968\" data-end=\"3978\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"3980\" data-end=\"4005\"\u003eRepeatability\u003cbr data-start=\"3993\" data-end=\"3996\"\u003e\u003cstrong data-start=\"3996\" data-end=\"4005\"\u003e0.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4007\" data-end=\"4029\"\u003eLinearity\u003cbr data-start=\"4016\" data-end=\"4019\"\u003e\u003cstrong data-start=\"4019\" data-end=\"4029\"\u003e±0.3 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4031\" data-end=\"4065\"\u003eStabilization time\u003cbr data-start=\"4049\" data-end=\"4052\"\u003e\u003cstrong data-start=\"4052\" data-end=\"4065\"\u003e3 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4067\" data-end=\"4070\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4072\" data-end=\"4081\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4083\" data-end=\"4106\"\u003e\u003cstrong data-start=\"4083\" data-end=\"4106\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4108\" data-end=\"4111\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4113\" data-end=\"4132\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4134\" data-end=\"4167\"\u003eDimensions\u003cbr data-start=\"4144\" data-end=\"4147\"\u003e\u003cstrong data-start=\"4147\" data-end=\"4167\"\u003e7.7 × 7.7 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4169\" data-end=\"4199\"\u003eMaterial\u003cbr data-start=\"4177\" data-end=\"4180\"\u003e\u003cstrong data-start=\"4180\" data-end=\"4199\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4201\" data-end=\"4204\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4206\" data-end=\"4220\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4222\" data-end=\"4247\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4249\" data-end=\"4309\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4249\" data-end=\"4264\"\u003e\n\u003cp data-start=\"4251\" data-end=\"4264\"\u003e\u003cstrong data-start=\"4251\" data-end=\"4264\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4265\" data-end=\"4276\"\u003e\n\u003cp data-start=\"4267\" data-end=\"4276\"\u003e\u003cstrong data-start=\"4267\" data-end=\"4276\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4277\" data-end=\"4288\"\u003e\n\u003cp data-start=\"4279\" data-end=\"4288\"\u003e\u003cstrong data-start=\"4279\" data-end=\"4288\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4289\" data-end=\"4309\"\u003e\n\u003cp data-start=\"4291\" data-end=\"4309\"\u003e\u003cstrong data-start=\"4291\" data-end=\"4309\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4311\" data-end=\"4314\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4316\" data-end=\"4336\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4338\" data-end=\"4363\"\u003e\u003cstrong data-start=\"4338\" data-end=\"4363\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4365\" data-end=\"4410\"\u003eBattery operation time\u003cbr data-start=\"4387\" data-end=\"4390\"\u003e\u003cstrong data-start=\"4390\" data-end=\"4410\"\u003eApprox. 15 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4412\" data-end=\"4415\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4417\" data-end=\"4443\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4445\" data-end=\"4484\"\u003eOperating temperature\u003cbr data-start=\"4466\" data-end=\"4469\"\u003e\u003cstrong data-start=\"4469\" data-end=\"4484\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4486\" data-end=\"4539\"\u003eRelative humidity\u003cbr data-start=\"4503\" data-end=\"4506\"\u003e\u003cstrong data-start=\"4506\" data-end=\"4539\"\u003e10% – 85% RH (non-condensing)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4541\" data-end=\"4568\"\u003eProtection class\u003cbr data-start=\"4557\" data-end=\"4560\"\u003e\u003cstrong data-start=\"4560\" data-end=\"4568\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4570\" data-end=\"4573\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4575\" data-end=\"4596\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4598\" data-end=\"4644\"\u003ePackage dimensions\u003cbr data-start=\"4616\" data-end=\"4619\"\u003e\u003cstrong data-start=\"4619\" data-end=\"4644\"\u003e18.5 × 15 × 13 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4646\" data-end=\"4669\"\u003eUnit weight\u003cbr data-start=\"4657\" data-end=\"4660\"\u003e\u003cstrong data-start=\"4660\" data-end=\"4669\"\u003e6 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4671\" data-end=\"4700\"\u003eShipping weight\u003cbr data-start=\"4686\" data-end=\"4689\"\u003e\u003cstrong data-start=\"4689\" data-end=\"4700\"\u003e9.5 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4702\" data-end=\"4705\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"4707\" data-end=\"4728\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"4730\" data-end=\"4974\"\u003e\n\u003cli data-section-id=\"17nfq2i\" data-start=\"4730\" data-end=\"4772\"\u003e\n\u003cp data-start=\"4732\" data-end=\"4772\"\u003eRadwag WLC 20\/A2 Precision Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kemj4y\" data-start=\"4773\" data-end=\"4809\"\u003e\n\u003cp data-start=\"4775\" data-end=\"4809\"\u003eStainless Steel Weighing Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"17jzr3a\" data-start=\"4810\" data-end=\"4848\"\u003e\n\u003cp data-start=\"4812\" data-end=\"4848\"\u003eGrounding Foot (Spring Center) – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k4km4t\" data-start=\"4849\" data-end=\"4872\"\u003e\n\u003cp data-start=\"4851\" data-end=\"4872\"\u003eAdjustable Feet – 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v7a5cy\" data-start=\"4873\" data-end=\"4907\"\u003e\n\u003cp data-start=\"4875\" data-end=\"4907\"\u003eUnderhook Weighing Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"khd6o2\" data-start=\"4908\" data-end=\"4929\"\u003e\n\u003cp data-start=\"4910\" data-end=\"4929\"\u003ePower Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j22hfp\" data-start=\"4930\" data-end=\"4951\"\u003e\n\u003cp data-start=\"4932\" data-end=\"4951\"\u003ePlug Adapters – 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"4952\" data-end=\"4974\"\u003e\n\u003cp data-start=\"4954\" data-end=\"4974\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4976\" data-end=\"4979\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"4981\" data-end=\"4991\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"4993\" data-end=\"5025\"\u003e\u003cstrong data-start=\"4993\" data-end=\"5025\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282610581826,"sku":null,"price":802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/wlca-2-10b_wlc-20a2--wl-206-0022-1.jpg?v=1773589938"},{"product_id":"across-international-mya-5-5y-radwag-5-1g-capacity-1µg-readability-o1-microbalance","title":"Across International MYA 5.5Y Radwag 5.1g Capacity 1µg Readability Ø1\" MicroBalance","description":"\u003ch2 data-section-id=\"itikbh\" data-start=\"520\" data-end=\"596\"\u003eUltra-Precision Microbalance with ELLIPSIS Technology and 10″ Touchscreen\u003c\/h2\u003e\n\u003cp data-start=\"598\" data-end=\"943\"\u003eThe \u003cstrong data-start=\"602\" data-end=\"634\"\u003eRadwag MYA 5.5Y Microbalance\u003c\/strong\u003e is a state-of-the-art ultra-precision weighing instrument designed for laboratories requiring \u003cstrong data-start=\"729\" data-end=\"769\"\u003emicrogram-level measurement accuracy\u003c\/strong\u003e. With \u003cstrong data-start=\"776\" data-end=\"815\"\u003e1 µg readability and 5.1 g capacity\u003c\/strong\u003e, the MYA 5.5Y is ideal for pharmaceutical research, analytical chemistry, nanotechnology, and advanced scientific applications.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"1207\"\u003ePart of the \u003cstrong data-start=\"957\" data-end=\"983\"\u003eRadwag ELLIPSIS series\u003c\/strong\u003e, this microbalance features a powerful \u003cstrong data-start=\"1023\" data-end=\"1056\"\u003e10-inch touchscreen interface\u003c\/strong\u003e, advanced environmental compensation technologies, and intelligent software designed to improve measurement accuracy, traceability, and user workflow.\u003c\/p\u003e\n\u003cp data-start=\"1209\" data-end=\"1443\"\u003eInnovations such as \u003cstrong data-start=\"1229\" data-end=\"1357\"\u003eDigital Weighing Auditor, ReflexLEVEL automatic leveling system, Smart Minimum Weight monitoring, and air density correction\u003c\/strong\u003e ensure that the balance continuously verifies measurement conditions and performance.\u003c\/p\u003e\n\u003cp data-start=\"1445\" data-end=\"1632\"\u003eWith \u003cstrong data-start=\"1450\" data-end=\"1530\"\u003eadvanced connectivity including USB, Ethernet, Wi-Fi, and hotspot capability\u003c\/strong\u003e, the MYA 5.5Y integrates seamlessly into modern laboratory information systems and digital workflows.\u003c\/p\u003e\n\u003chr data-start=\"1634\" data-end=\"1637\"\u003e\n\u003ch1 data-section-id=\"jh92xq\" data-start=\"1639\" data-end=\"1689\"\u003eKey Features of the Radwag MYA 5.5Y Microbalance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"5d6a8p\" data-start=\"1691\" data-end=\"1724\"\u003eUltra-High Precision Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1725\" data-end=\"1871\"\u003eProvides \u003cstrong data-start=\"1734\" data-end=\"1782\"\u003e1 µg readability with 5.1 g maximum capacity\u003c\/strong\u003e, enabling extremely precise mass measurements for high-accuracy laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbskc8\" data-start=\"1873\" data-end=\"1901\"\u003eDigital Weighing Auditor\u003c\/h3\u003e\n\u003cp data-start=\"1902\" data-end=\"2119\"\u003eThe built-in \u003cstrong data-start=\"1915\" data-end=\"1943\"\u003eDigital Weighing Auditor\u003c\/strong\u003e continuously verifies that the balance is ready for use and compensates for \u003cstrong data-start=\"2020\" data-end=\"2049\"\u003eair buoyancy in real time\u003c\/strong\u003e. It also alerts users when inspection or calibration may be required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16mi94l\" data-start=\"2121\" data-end=\"2155\"\u003eLarge 10″ ELLIPSIS Touchscreen\u003c\/h3\u003e\n\u003cp data-start=\"2156\" data-end=\"2223\"\u003eThe advanced \u003cstrong data-start=\"2169\" data-end=\"2201\"\u003e10-inch touchscreen terminal\u003c\/strong\u003e allows users to view:\u003c\/p\u003e\n\u003cul data-start=\"2225\" data-end=\"2376\"\u003e\n\u003cli data-section-id=\"1jocsql\" data-start=\"2225\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2227\" data-end=\"2245\"\u003eMeasurement graphs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6or1s5\" data-start=\"2246\" data-end=\"2273\"\u003e\n\u003cp data-start=\"2248\" data-end=\"2273\"\u003eProcess status indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oqmbag\" data-start=\"2274\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2276\" data-end=\"2305\"\u003eNotes and measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p00g57\" data-start=\"2306\" data-end=\"2339\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2339\"\u003eMultiple widgets and dashboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1eyo9bf\" data-start=\"2340\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2342\" data-end=\"2376\"\u003eUp to three screens simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17ceyjf\" data-start=\"2378\" data-end=\"2412\"\u003eReflexLEVEL Automatic Leveling\u003c\/h3\u003e\n\u003cp data-start=\"2413\" data-end=\"2537\"\u003eThe \u003cstrong data-start=\"2417\" data-end=\"2472\"\u003eReflexLEVEL system automatically levels the balance\u003c\/strong\u003e, eliminating manual leveling and improving measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"q2j805\" data-start=\"2539\" data-end=\"2577\"\u003eAmbient Light Communication System\u003c\/h3\u003e\n\u003cp data-start=\"2578\" data-end=\"2701\"\u003eAn integrated \u003cstrong data-start=\"2592\" data-end=\"2619\"\u003eambient light indicator\u003c\/strong\u003e communicates balance status, measurement results, and alerts using color signals.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rwqjgl\" data-start=\"2703\" data-end=\"2738\"\u003eSmart Minimum Weight Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"2739\" data-end=\"2869\"\u003eDisplays whether the current sample weight is \u003cstrong data-start=\"2785\" data-end=\"2832\"\u003eabove or below the minimum weight threshold\u003c\/strong\u003e, ensuring valid measurement results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1re5pow\" data-start=\"2871\" data-end=\"2901\"\u003eAdvanced User Verification\u003c\/h3\u003e\n\u003cp data-start=\"2902\" data-end=\"2939\"\u003eSupports secure authentication using:\u003c\/p\u003e\n\u003cul data-start=\"2941\" data-end=\"3052\"\u003e\n\u003cli data-section-id=\"1rs2y50\" data-start=\"2941\" data-end=\"2959\"\u003e\n\u003cp data-start=\"2943\" data-end=\"2959\"\u003ePassword login\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vu9j8l\" data-start=\"2960\" data-end=\"2973\"\u003e\n\u003cp data-start=\"2962\" data-end=\"2973\"\u003eRFID card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1swv6dr\" data-start=\"2974\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2976\" data-end=\"3001\"\u003eFingerprint recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11aaju7\" data-start=\"3002\" data-end=\"3024\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3024\"\u003eFacial recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2ssl4b\" data-start=\"3025\" data-end=\"3052\"\u003e\n\u003cp data-start=\"3027\" data-end=\"3052\"\u003eMulti-factor combinations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ah7r85\" data-start=\"3054\" data-end=\"3077\"\u003eRFID Identification\u003c\/h3\u003e\n\u003cp data-start=\"3078\" data-end=\"3103\"\u003eRFID tags can be used to:\u003c\/p\u003e\n\u003cul data-start=\"3105\" data-end=\"3204\"\u003e\n\u003cli data-section-id=\"1rv64ha\" data-start=\"3105\" data-end=\"3121\"\u003e\n\u003cp data-start=\"3107\" data-end=\"3121\"\u003eIdentify users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gzd2u\" data-start=\"3122\" data-end=\"3162\"\u003e\n\u003cp data-start=\"3124\" data-end=\"3162\"\u003eTag samples or formulation ingredients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1spqsn6\" data-start=\"3163\" data-end=\"3204\"\u003e\n\u003cp data-start=\"3165\" data-end=\"3204\"\u003eTrack materials in the balance database\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"hd4mdk\" data-start=\"3206\" data-end=\"3230\"\u003eHotspot Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3231\" data-end=\"3345\"\u003eThe balance can create its own \u003cstrong data-start=\"3262\" data-end=\"3279\"\u003eWi-Fi hotspot\u003c\/strong\u003e, allowing smartphones, tablets, or computers to connect directly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzkj2r\" data-start=\"3347\" data-end=\"3361\"\u003eLive Notes\u003c\/h3\u003e\n\u003cp data-start=\"3362\" data-end=\"3455\"\u003eUsers can attach \u003cstrong data-start=\"3379\" data-end=\"3411\"\u003evoice notes or text comments\u003c\/strong\u003e to measurement series or procedure reports.\u003c\/p\u003e\n\u003ch3 data-section-id=\"48055v\" data-start=\"3457\" data-end=\"3474\"\u003eHandy Library\u003c\/h3\u003e\n\u003cp data-start=\"3475\" data-end=\"3500\"\u003eProvides quick access to:\u003c\/p\u003e\n\u003cul data-start=\"3502\" data-end=\"3609\"\u003e\n\u003cli data-section-id=\"ccgq5n\" data-start=\"3502\" data-end=\"3530\"\u003e\n\u003cp data-start=\"3504\" data-end=\"3530\"\u003eRecent measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fqz3zv\" data-start=\"3531\" data-end=\"3568\"\u003e\n\u003cp data-start=\"3533\" data-end=\"3568\"\u003eReports ready for digital signature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kzpfxy\" data-start=\"3569\" data-end=\"3609\"\u003e\n\u003cp data-start=\"3571\" data-end=\"3609\"\u003eData compliant with \u003cstrong data-start=\"3591\" data-end=\"3609\"\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"yt04p0\" data-start=\"3611\" data-end=\"3635\"\u003eTwo-Point Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3636\" data-end=\"3740\"\u003eCalibration performed at \u003cstrong data-start=\"3661\" data-end=\"3687\"\u003etwo measurement points\u003c\/strong\u003e improves precision across the entire weighing range.\u003c\/p\u003e\n\u003chr data-start=\"3742\" data-end=\"3745\"\u003e\n\u003ch1 data-section-id=\"nj2mc6\" data-start=\"3747\" data-end=\"3777\"\u003eCompliance and Data Security\u003c\/h1\u003e\n\u003cp data-start=\"3779\" data-end=\"3936\"\u003eThe MYA 5.5Y microbalance supports optional \u003cstrong data-start=\"3823\" data-end=\"3852\"\u003e21 CFR Part 11 compliance\u003c\/strong\u003e, making it suitable for regulated environments such as pharmaceutical laboratories.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ea5lk6\" data-start=\"3938\" data-end=\"3968\"\u003eCompliance Module Features\u003c\/h3\u003e\n\u003cul data-start=\"3970\" data-end=\"4135\"\u003e\n\u003cli data-section-id=\"4lnuvx\" data-start=\"3970\" data-end=\"3993\"\u003e\n\u003cp data-start=\"3972\" data-end=\"3993\"\u003eElectronic signatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fbl7wq\" data-start=\"3994\" data-end=\"4024\"\u003e\n\u003cp data-start=\"3996\" data-end=\"4024\"\u003eAdvanced password protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nl5kvf\" data-start=\"4025\" data-end=\"4054\"\u003e\n\u003cp data-start=\"4027\" data-end=\"4054\"\u003eControlled user permissions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s01jpb\" data-start=\"4055\" data-end=\"4073\"\u003e\n\u003cp data-start=\"4057\" data-end=\"4073\"\u003eAutomatic logout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jm4kdm\" data-start=\"4074\" data-end=\"4097\"\u003e\n\u003cp data-start=\"4076\" data-end=\"4097\"\u003eAudit Trail recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16qwjei\" data-start=\"4098\" data-end=\"4135\"\u003e\n\u003cp data-start=\"4100\" data-end=\"4135\"\u003eBackup and data management controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4137\" data-end=\"4207\"\u003eThe \u003cstrong data-start=\"4141\" data-end=\"4195\"\u003eAudit Trail system records every data modification\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"4209\" data-end=\"4281\"\u003e\n\u003cli data-section-id=\"cehz8i\" data-start=\"4209\" data-end=\"4224\"\u003e\n\u003cp data-start=\"4211\" data-end=\"4224\"\u003eDate and time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hf6dju\" data-start=\"4225\" data-end=\"4241\"\u003e\n\u003cp data-start=\"4227\" data-end=\"4241\"\u003eOriginal value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jhndj6\" data-start=\"4242\" data-end=\"4258\"\u003e\n\u003cp data-start=\"4244\" data-end=\"4258\"\u003eModified value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2d2bik\" data-start=\"4259\" data-end=\"4281\"\u003e\n\u003cp data-start=\"4261\" data-end=\"4281\"\u003eResponsible operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4283\" data-end=\"4348\"\u003eAudit data can be exported in \u003cstrong data-start=\"4313\" data-end=\"4347\"\u003ePDF, XLS, CSV, or HTML formats\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4350\" data-end=\"4353\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"4355\" data-end=\"4384\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"4386\" data-end=\"4472\"\u003eThe MYA 5.5Y microbalance includes a comprehensive set of professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"4474\" data-end=\"4486\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"4487\" data-end=\"4566\"\u003eAutomatic diagnostics evaluate repeatability and optimize weighing performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"4568\" data-end=\"4578\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"4579\" data-end=\"4679\"\u003eAllows controlled weighing of powders, liquids, or granular materials with defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"4681\" data-end=\"4701\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4702\" data-end=\"4768\"\u003eDisplays sample mass as a percentage relative to a reference mass.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"4770\" data-end=\"4788\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"4789\" data-end=\"4876\"\u003eDetermines item quantity based on known unit weight with automatic accuracy correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nnh1is\" data-start=\"4878\" data-end=\"4893\"\u003eFormulation\u003c\/h3\u003e\n\u003cp data-start=\"4894\" data-end=\"4965\"\u003eSupports multi-component mixture preparation with tolerance monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1agpw9b\" data-start=\"4967\" data-end=\"4991\"\u003eStatistical Analysis\u003c\/h3\u003e\n\u003cp data-start=\"4992\" data-end=\"5028\"\u003eProvides statistical data including:\u003c\/p\u003e\n\u003cul data-start=\"5030\" data-end=\"5126\"\u003e\n\u003cli data-section-id=\"1tpje4l\" data-start=\"5030\" data-end=\"5058\"\u003e\n\u003cp data-start=\"5032\" data-end=\"5058\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s9zm9s\" data-start=\"5059\" data-end=\"5074\"\u003e\n\u003cp data-start=\"5061\" data-end=\"5074\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvyhm8\" data-start=\"5075\" data-end=\"5095\"\u003e\n\u003cp data-start=\"5077\" data-end=\"5095\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwk9jh\" data-start=\"5096\" data-end=\"5106\"\u003e\n\u003cp data-start=\"5098\" data-end=\"5106\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xk4t9\" data-start=\"5107\" data-end=\"5126\"\u003e\n\u003cp data-start=\"5109\" data-end=\"5126\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"a1clir\" data-start=\"5128\" data-end=\"5153\"\u003eDifferential Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5154\" data-end=\"5221\"\u003eDetermines mass variation during manufacturing or processing steps.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ly0npz\" data-start=\"5223\" data-end=\"5254\"\u003eStatistical Quality Control\u003c\/h3\u003e\n\u003cp data-start=\"5255\" data-end=\"5321\"\u003eMonitors production batches with automated statistical evaluation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"5323\" data-end=\"5340\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"5341\" data-end=\"5403\"\u003eIndicates whether a sample falls within defined weight limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n8woyc\" data-start=\"5405\" data-end=\"5424\"\u003eAnimal Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5425\" data-end=\"5478\"\u003eAllows accurate mass determination of moving samples.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nmwv3m\" data-start=\"5480\" data-end=\"5506\"\u003eAir Density Correction\u003c\/h3\u003e\n\u003cp data-start=\"5507\" data-end=\"5580\"\u003eCorrects measurement results by accounting for environmental air density.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1b1e0do\" data-start=\"5582\" data-end=\"5603\"\u003eIR Sensor Control\u003c\/h3\u003e\n\u003cp data-start=\"5604\" data-end=\"5658\"\u003eTouch-free infrared sensors enable operations such as:\u003c\/p\u003e\n\u003cul data-start=\"5660\" data-end=\"5713\"\u003e\n\u003cli data-section-id=\"18leszv\" data-start=\"5660\" data-end=\"5683\"\u003e\n\u003cp data-start=\"5662\" data-end=\"5683\"\u003eOpening chamber doors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q29ch6\" data-start=\"5684\" data-end=\"5693\"\u003e\n\u003cp data-start=\"5686\" data-end=\"5693\"\u003eZeroing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5ro1vz\" data-start=\"5694\" data-end=\"5702\"\u003e\n\u003cp data-start=\"5696\" data-end=\"5702\"\u003eTaring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1goa1q1\" data-start=\"5703\" data-end=\"5713\"\u003e\n\u003cp data-start=\"5705\" data-end=\"5713\"\u003ePrinting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"5715\" data-end=\"5732\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"5733\" data-end=\"5785\"\u003eSupports \u003cstrong data-start=\"5742\" data-end=\"5784\"\u003eGood Laboratory Practice documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5787\" data-end=\"5790\"\u003e\n\u003ch1 data-section-id=\"ggdxdk\" data-start=\"5792\" data-end=\"5811\"\u003eALIBI Data Memory\u003c\/h1\u003e\n\u003cp data-start=\"5813\" data-end=\"5905\"\u003eThe integrated \u003cstrong data-start=\"5828\" data-end=\"5893\"\u003eALIBI memory automatically records up to 100,000 measurements\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"5907\" data-end=\"6005\"\u003e\n\u003cli data-section-id=\"1obhcxi\" data-start=\"5907\" data-end=\"5925\"\u003e\n\u003cp data-start=\"5909\" data-end=\"5925\"\u003eMeasurement date\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j4crzx\" data-start=\"5926\" data-end=\"5932\"\u003e\n\u003cp data-start=\"5928\" data-end=\"5932\"\u003eTime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ie1rkd\" data-start=\"5933\" data-end=\"5946\"\u003e\n\u003cp data-start=\"5935\" data-end=\"5946\"\u003eMass result\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14lfw5d\" data-start=\"5947\" data-end=\"5959\"\u003e\n\u003cp data-start=\"5949\" data-end=\"5959\"\u003eTare value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a2rsbk\" data-start=\"5960\" data-end=\"5980\"\u003e\n\u003cp data-start=\"5962\" data-end=\"5980\"\u003eLogged-in operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y91o3t\" data-start=\"5981\" data-end=\"6005\"\u003e\n\u003cp data-start=\"5983\" data-end=\"6005\"\u003eProduct identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6007\" data-end=\"6093\"\u003eStored measurements cannot be manually deleted, ensuring \u003cstrong data-start=\"6064\" data-end=\"6092\"\u003esecure data traceability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"6095\" data-end=\"6098\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"6100\" data-end=\"6120\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"6122\" data-end=\"6175\"\u003eThe Radwag MYA 5.5Y microbalance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"6177\" data-end=\"6380\"\u003e\n\u003cli data-section-id=\"1hipxyr\" data-start=\"6177\" data-end=\"6217\"\u003e\n\u003cp data-start=\"6179\" data-end=\"6217\"\u003ePharmaceutical research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ktawpv\" data-start=\"6218\" data-end=\"6255\"\u003e\n\u003cp data-start=\"6220\" data-end=\"6255\"\u003eAnalytical chemistry laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"126lv89\" data-start=\"6256\" data-end=\"6283\"\u003e\n\u003cp data-start=\"6258\" data-end=\"6283\"\u003eNanotechnology research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6eze3\" data-start=\"6284\" data-end=\"6309\"\u003e\n\u003cp data-start=\"6286\" data-end=\"6309\"\u003eMicro-sample analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"6310\" data-end=\"6342\"\u003e\n\u003cp data-start=\"6312\" data-end=\"6342\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xykno0\" data-start=\"6343\" data-end=\"6380\"\u003e\n\u003cp data-start=\"6345\" data-end=\"6380\"\u003eBiotechnology research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6382\" data-end=\"6385\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"6387\" data-end=\"6413\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"6415\" data-end=\"6423\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"6424\" data-end=\"6436\"\u003e\u003cstrong data-start=\"6424\" data-end=\"6436\"\u003eMYA 5.5Y\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6438\" data-end=\"6466\"\u003ePart Number: \u003cstrong data-start=\"6451\" data-end=\"6466\"\u003eWL-109-0006\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6468\" data-end=\"6471\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"6473\" data-end=\"6495\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"6497\" data-end=\"6525\"\u003eMaximum capacity\u003cbr data-start=\"6513\" data-end=\"6516\"\u003e\u003cstrong data-start=\"6516\" data-end=\"6525\"\u003e5.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6527\" data-end=\"6552\"\u003eMinimum load\u003cbr data-start=\"6539\" data-end=\"6542\"\u003e\u003cstrong data-start=\"6542\" data-end=\"6552\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6554\" data-end=\"6576\"\u003eReadability\u003cbr data-start=\"6565\" data-end=\"6568\"\u003e\u003cstrong data-start=\"6568\" data-end=\"6576\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6578\" data-end=\"6601\"\u003eTare range\u003cbr data-start=\"6588\" data-end=\"6591\"\u003e\u003cstrong data-start=\"6591\" data-end=\"6601\"\u003e−5.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6603\" data-end=\"6606\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"6608\" data-end=\"6618\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"6620\" data-end=\"6655\"\u003eRepeatability (5% Max)\u003cbr data-start=\"6642\" data-end=\"6645\"\u003e\u003cstrong data-start=\"6645\" data-end=\"6655\"\u003e0.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6657\" data-end=\"6689\"\u003eRepeatability (Max)\u003cbr data-start=\"6676\" data-end=\"6679\"\u003e\u003cstrong data-start=\"6679\" data-end=\"6689\"\u003e1.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6691\" data-end=\"6738\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"6725\" data-end=\"6728\"\u003e\u003cstrong data-start=\"6728\" data-end=\"6738\"\u003e1.2 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6740\" data-end=\"6784\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6771\" data-end=\"6774\"\u003e\u003cstrong data-start=\"6774\" data-end=\"6784\"\u003e2.4 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6786\" data-end=\"6807\"\u003eLinearity\u003cbr data-start=\"6795\" data-end=\"6798\"\u003e\u003cstrong data-start=\"6798\" data-end=\"6807\"\u003e±5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6809\" data-end=\"6851\"\u003eStabilization time\u003cbr data-start=\"6827\" data-end=\"6830\"\u003e\u003cstrong data-start=\"6830\" data-end=\"6851\"\u003eMaximum 8 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6853\" data-end=\"6856\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6858\" data-end=\"6881\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6883\" data-end=\"6914\"\u003eUSP minimum weight\u003cbr data-start=\"6901\" data-end=\"6904\"\u003e\u003cstrong data-start=\"6904\" data-end=\"6914\"\u003e1.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6916\" data-end=\"6960\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"6946\" data-end=\"6949\"\u003e\u003cstrong data-start=\"6949\" data-end=\"6960\"\u003e0.12 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6962\" data-end=\"6965\"\u003e\n\u003ch1 data-section-id=\"1mcqff0\" data-start=\"6967\" data-end=\"6980\"\u003eCalibration\u003c\/h1\u003e\n\u003cp data-start=\"6982\" data-end=\"7015\"\u003e\u003cstrong data-start=\"6982\" data-end=\"7015\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7017\" data-end=\"7020\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"7022\" data-end=\"7043\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"7045\" data-end=\"7056\"\u003e\u003cstrong data-start=\"7045\" data-end=\"7056\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7058\" data-end=\"7061\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"7063\" data-end=\"7072\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"7074\" data-end=\"7117\"\u003e\u003cstrong data-start=\"7074\" data-end=\"7117\"\u003e10-inch touchscreen (ELLIPSIS terminal)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7119\" data-end=\"7122\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"7124\" data-end=\"7138\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"7140\" data-end=\"7173\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"7175\" data-end=\"7266\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"7175\" data-end=\"7189\"\u003e\n\u003cp data-start=\"7177\" data-end=\"7189\"\u003e\u003cstrong data-start=\"7177\" data-end=\"7189\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"7190\" data-end=\"7201\"\u003e\n\u003cp data-start=\"7192\" data-end=\"7201\"\u003e\u003cstrong data-start=\"7192\" data-end=\"7201\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"7202\" data-end=\"7212\"\u003e\n\u003cp data-start=\"7204\" data-end=\"7212\"\u003e\u003cstrong data-start=\"7204\" data-end=\"7212\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"7213\" data-end=\"7227\"\u003e\n\u003cp data-start=\"7215\" data-end=\"7227\"\u003e\u003cstrong data-start=\"7215\" data-end=\"7227\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"7228\" data-end=\"7239\"\u003e\n\u003cp data-start=\"7230\" data-end=\"7239\"\u003e\u003cstrong data-start=\"7230\" data-end=\"7239\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"7240\" data-end=\"7266\"\u003e\n\u003cp data-start=\"7242\" data-end=\"7266\"\u003e\u003cstrong data-start=\"7242\" data-end=\"7266\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7268\" data-end=\"7271\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"7273\" data-end=\"7295\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"7297\" data-end=\"7336\"\u003eOperating temperature\u003cbr data-start=\"7318\" data-end=\"7321\"\u003e\u003cstrong data-start=\"7321\" data-end=\"7336\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7338\" data-end=\"7393\"\u003eTemperature stability requirement\u003cbr data-start=\"7371\" data-end=\"7374\"\u003e\u003cstrong data-start=\"7374\" data-end=\"7393\"\u003e±0.3°C per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7395\" data-end=\"7428\"\u003eRelative humidity\u003cbr data-start=\"7412\" data-end=\"7415\"\u003e\u003cstrong data-start=\"7415\" data-end=\"7428\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7430\" data-end=\"7469\"\u003eHumidity change rate\u003cbr data-start=\"7450\" data-end=\"7453\"\u003e\u003cstrong data-start=\"7453\" data-end=\"7469\"\u003e±1% per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7471\" data-end=\"7474\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"7476\" data-end=\"7494\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"7496\" data-end=\"7520\"\u003ePan diameter\u003cbr data-start=\"7508\" data-end=\"7511\"\u003e\u003cstrong data-start=\"7511\" data-end=\"7520\"\u003e26 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7522\" data-end=\"7557\"\u003eChamber dimensions\u003cbr data-start=\"7540\" data-end=\"7543\"\u003e\u003cstrong data-start=\"7543\" data-end=\"7557\"\u003e90 × 90 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7559\" data-end=\"7562\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"7564\" data-end=\"7585\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"7587\" data-end=\"7630\"\u003ePackage dimensions\u003cbr data-start=\"7605\" data-end=\"7608\"\u003e\u003cstrong data-start=\"7608\" data-end=\"7630\"\u003e655 × 755 × 445 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7632\" data-end=\"7656\"\u003eUnit weight\u003cbr data-start=\"7643\" data-end=\"7646\"\u003e\u003cstrong data-start=\"7646\" data-end=\"7656\"\u003e45 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7658\" data-end=\"7686\"\u003eShipping weight\u003cbr data-start=\"7673\" data-end=\"7676\"\u003e\u003cstrong data-start=\"7676\" data-end=\"7686\"\u003e75 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7688\" data-end=\"7691\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"7693\" data-end=\"7713\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"7715\" data-end=\"7750\"\u003eAdapter\u003cbr data-start=\"7722\" data-end=\"7725\"\u003e\u003cstrong data-start=\"7725\" data-end=\"7750\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7752\" data-end=\"7781\"\u003eBalance input\u003cbr data-start=\"7765\" data-end=\"7768\"\u003e\u003cstrong data-start=\"7768\" data-end=\"7781\"\u003e12–15V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"7783\" data-end=\"7786\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7788\" data-end=\"7798\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7800\" data-end=\"7832\"\u003e\u003cstrong data-start=\"7800\" data-end=\"7832\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282613367106,"sku":null,"price":24961.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/MYA_5.5Y__WL-109-0006_-removebg-preview.png?v=1773590093"},{"product_id":"across-international-mya-2-5y-radwag-2-1-g-capacity-0-1-µg-readability-o16-mm-microbalance","title":"Across International MYA 2.5Y Radwag 2.1 g Capacity 0.1 µg Readability ø16 mm Microbalance","description":"\u003ch2 data-section-id=\"15o89qi\" data-start=\"373\" data-end=\"460\"\u003eUltra-High Precision Microbalance with 10″ Touchscreen and ELLIPSIS Smart Technology\u003c\/h2\u003e\n\u003cp data-start=\"462\" data-end=\"838\"\u003eThe \u003cstrong data-start=\"466\" data-end=\"498\"\u003eRadwag MYA 2.5Y Microbalance\u003c\/strong\u003e is an ultra-precision laboratory balance designed for applications requiring \u003cstrong data-start=\"576\" data-end=\"604\"\u003emicrogram-level accuracy\u003c\/strong\u003e. With \u003cstrong data-start=\"611\" data-end=\"650\"\u003e1 µg readability and 2.1 g capacity\u003c\/strong\u003e, the MYA 2.5Y is ideal for high-precision research environments including pharmaceutical laboratories, analytical chemistry labs, nanotechnology research, and advanced scientific testing.\u003c\/p\u003e\n\u003cp data-start=\"840\" data-end=\"1146\"\u003ePart of the \u003cstrong data-start=\"852\" data-end=\"878\"\u003eRadwag ELLIPSIS series\u003c\/strong\u003e, this microbalance integrates innovative smart technologies including a \u003cstrong data-start=\"951\" data-end=\"1079\"\u003eDigital Weighing Auditor, ReflexLEVEL automatic leveling system, Smart Minimum Weight monitoring, and air density correction\u003c\/strong\u003e to ensure optimal weighing conditions and measurement reliability.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1401\"\u003eThe balance features an advanced \u003cstrong data-start=\"1181\" data-end=\"1213\"\u003e10-inch touchscreen terminal\u003c\/strong\u003e, intuitive user interface, and powerful connectivity options such as \u003cstrong data-start=\"1283\" data-end=\"1333\"\u003eUSB, Ethernet, Wi-Fi, and hotspot connectivity\u003c\/strong\u003e, enabling seamless integration with modern laboratory data systems.\u003c\/p\u003e\n\u003chr data-start=\"1403\" data-end=\"1406\"\u003e\n\u003ch1 data-section-id=\"1wfr49l\" data-start=\"1408\" data-end=\"1458\"\u003eKey Features of the Radwag MYA 2.5Y Microbalance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"8qg2xb\" data-start=\"1460\" data-end=\"1500\"\u003eUltra-Precision Weighing Performance\u003c\/h3\u003e\n\u003cp data-start=\"1501\" data-end=\"1646\"\u003eProvides \u003cstrong data-start=\"1510\" data-end=\"1558\"\u003e1 µg readability with 2.1 g maximum capacity\u003c\/strong\u003e, enabling extremely precise mass determination for micro-scale laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbskc8\" data-start=\"1648\" data-end=\"1676\"\u003eDigital Weighing Auditor\u003c\/h3\u003e\n\u003cp data-start=\"1677\" data-end=\"1900\"\u003eThe integrated \u003cstrong data-start=\"1692\" data-end=\"1720\"\u003eDigital Weighing Auditor\u003c\/strong\u003e continuously monitors the balance’s readiness and compensates for \u003cstrong data-start=\"1787\" data-end=\"1816\"\u003eair buoyancy in real time\u003c\/strong\u003e. It also alerts users when balance inspection or accuracy verification is required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iecdcq\" data-start=\"1902\" data-end=\"1934\"\u003e10-Inch ELLIPSIS Touchscreen\u003c\/h3\u003e\n\u003cp data-start=\"1935\" data-end=\"1997\"\u003eThe large \u003cstrong data-start=\"1945\" data-end=\"1972\"\u003e10″ touchscreen display\u003c\/strong\u003e allows users to monitor:\u003c\/p\u003e\n\u003cul data-start=\"1999\" data-end=\"2148\"\u003e\n\u003cli data-section-id=\"jmr6pt\" data-start=\"1999\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2001\" data-end=\"2046\"\u003eMultiple measurement screens simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3iyw9g\" data-start=\"2047\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2081\"\u003eGraphs and measurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ud9594\" data-start=\"2082\" data-end=\"2114\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2114\"\u003eStatus indicators and alerts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1i7jsoo\" data-start=\"2115\" data-end=\"2148\"\u003e\n\u003cp data-start=\"2117\" data-end=\"2148\"\u003eCustom widgets and dashboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"mm5au6\" data-start=\"2150\" data-end=\"2191\"\u003eReflexLEVEL Automatic Leveling System\u003c\/h3\u003e\n\u003cp data-start=\"2192\" data-end=\"2320\"\u003eThe \u003cstrong data-start=\"2196\" data-end=\"2251\"\u003eReflexLEVEL system automatically levels the balance\u003c\/strong\u003e, eliminating manual adjustments and improving measurement precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1k202xs\" data-start=\"2322\" data-end=\"2353\"\u003eAmbient Light Communication\u003c\/h3\u003e\n\u003cp data-start=\"2354\" data-end=\"2495\"\u003eIntegrated ambient lighting communicates balance status through color signals indicating process results, alerts, and measurement conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14xsojt\" data-start=\"2497\" data-end=\"2529\"\u003eAdvanced User Authentication\u003c\/h3\u003e\n\u003cp data-start=\"2530\" data-end=\"2570\"\u003eSupports secure user identification via:\u003c\/p\u003e\n\u003cul data-start=\"2572\" data-end=\"2701\"\u003e\n\u003cli data-section-id=\"1rs2y50\" data-start=\"2572\" data-end=\"2590\"\u003e\n\u003cp data-start=\"2574\" data-end=\"2590\"\u003ePassword login\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10s7sja\" data-start=\"2591\" data-end=\"2605\"\u003e\n\u003cp data-start=\"2593\" data-end=\"2605\"\u003eRFID cards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1swv6dr\" data-start=\"2606\" data-end=\"2633\"\u003e\n\u003cp data-start=\"2608\" data-end=\"2633\"\u003eFingerprint recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11aaju7\" data-start=\"2634\" data-end=\"2656\"\u003e\n\u003cp data-start=\"2636\" data-end=\"2656\"\u003eFacial recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1eacdkb\" data-start=\"2657\" data-end=\"2701\"\u003e\n\u003cp data-start=\"2659\" data-end=\"2701\"\u003eMulti-factor authentication combinations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hdcg1t\" data-start=\"2703\" data-end=\"2723\"\u003eRFID Integration\u003c\/h3\u003e\n\u003cp data-start=\"2724\" data-end=\"2766\"\u003eRFID technology enables identification of:\u003c\/p\u003e\n\u003cul data-start=\"2768\" data-end=\"2817\"\u003e\n\u003cli data-section-id=\"15qgrd6\" data-start=\"2768\" data-end=\"2777\"\u003e\n\u003cp data-start=\"2770\" data-end=\"2777\"\u003eUsers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lt94cd\" data-start=\"2778\" data-end=\"2789\"\u003e\n\u003cp data-start=\"2780\" data-end=\"2789\"\u003eSamples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pd5uek\" data-start=\"2790\" data-end=\"2817\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2817\"\u003eFormulation ingredients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2819\" data-end=\"2899\"\u003eRFID tags can be linked to balance databases for improved workflow traceability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hd4mdk\" data-start=\"2901\" data-end=\"2925\"\u003eHotspot Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"2926\" data-end=\"3043\"\u003eThe balance can create its own \u003cstrong data-start=\"2957\" data-end=\"2977\"\u003ewireless hotspot\u003c\/strong\u003e, allowing smartphones, tablets, or computers to connect directly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzkj2r\" data-start=\"3045\" data-end=\"3059\"\u003eLive Notes\u003c\/h3\u003e\n\u003cp data-start=\"3060\" data-end=\"3150\"\u003eUsers can attach \u003cstrong data-start=\"3077\" data-end=\"3106\"\u003evoice memos or text notes\u003c\/strong\u003e to measurement series or procedure reports.\u003c\/p\u003e\n\u003ch3 data-section-id=\"48055v\" data-start=\"3152\" data-end=\"3169\"\u003eHandy Library\u003c\/h3\u003e\n\u003cp data-start=\"3170\" data-end=\"3177\"\u003eStores:\u003c\/p\u003e\n\u003cul data-start=\"3179\" data-end=\"3299\"\u003e\n\u003cli data-section-id=\"7isb2v\" data-start=\"3179\" data-end=\"3209\"\u003e\n\u003cp data-start=\"3181\" data-end=\"3209\"\u003eRecent measurement records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wjyol7\" data-start=\"3210\" data-end=\"3249\"\u003e\n\u003cp data-start=\"3212\" data-end=\"3249\"\u003eReports ready for digital signature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"55fpuc\" data-start=\"3250\" data-end=\"3299\"\u003e\n\u003cp data-start=\"3252\" data-end=\"3299\"\u003eDocumentation compliant with \u003cstrong data-start=\"3281\" data-end=\"3299\"\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rwqjgl\" data-start=\"3301\" data-end=\"3336\"\u003eSmart Minimum Weight Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"3337\" data-end=\"3446\"\u003eDisplays whether the sample weight is above the required \u003cstrong data-start=\"3394\" data-end=\"3422\"\u003eminimum weight threshold\u003c\/strong\u003e for valid measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yt04p0\" data-start=\"3448\" data-end=\"3472\"\u003eTwo-Point Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3473\" data-end=\"3578\"\u003eCalibration at \u003cstrong data-start=\"3488\" data-end=\"3514\"\u003etwo measurement points\u003c\/strong\u003e improves measurement accuracy across the entire weighing range.\u003c\/p\u003e\n\u003chr data-start=\"3580\" data-end=\"3583\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3585\" data-end=\"3614\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"3616\" data-end=\"3695\"\u003eThe MYA 2.5Y microbalance supports a wide range of professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"3697\" data-end=\"3709\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"3710\" data-end=\"3789\"\u003eAutomatic diagnostic function evaluating balance repeatability and performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"3791\" data-end=\"3801\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"3802\" data-end=\"3862\"\u003ePrecise dosing based on reference mass and tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"3864\" data-end=\"3884\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3885\" data-end=\"3954\"\u003eDisplays sample weight as a percentage relative to a reference value.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3956\" data-end=\"3974\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3975\" data-end=\"4058\"\u003eDetermines item quantity based on individual unit weight with automatic correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nnh1is\" data-start=\"4060\" data-end=\"4075\"\u003eFormulation\u003c\/h3\u003e\n\u003cp data-start=\"4076\" data-end=\"4149\"\u003eSupports multi-component formulation processes with tolerance monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1agpw9b\" data-start=\"4151\" data-end=\"4175\"\u003eStatistical Analysis\u003c\/h3\u003e\n\u003cp data-start=\"4176\" data-end=\"4212\"\u003eProvides statistical data including:\u003c\/p\u003e\n\u003cul data-start=\"4214\" data-end=\"4320\"\u003e\n\u003cli data-section-id=\"1s8fw79\" data-start=\"4214\" data-end=\"4244\"\u003e\n\u003cp data-start=\"4216\" data-end=\"4244\"\u003eMinimum and maximum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wqiow0\" data-start=\"4245\" data-end=\"4262\"\u003e\n\u003cp data-start=\"4247\" data-end=\"4262\"\u003eAverage value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zb8w\" data-start=\"4263\" data-end=\"4285\"\u003e\n\u003cp data-start=\"4265\" data-end=\"4285\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7dum31\" data-start=\"4286\" data-end=\"4298\"\u003e\n\u003cp data-start=\"4288\" data-end=\"4298\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189ryot\" data-start=\"4299\" data-end=\"4320\"\u003e\n\u003cp data-start=\"4301\" data-end=\"4320\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"a1clir\" data-start=\"4322\" data-end=\"4347\"\u003eDifferential Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4348\" data-end=\"4415\"\u003eMeasures mass variation during manufacturing or research processes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ly0npz\" data-start=\"4417\" data-end=\"4448\"\u003eStatistical Quality Control\u003c\/h3\u003e\n\u003cp data-start=\"4449\" data-end=\"4510\"\u003eProvides statistical batch control for production monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4512\" data-end=\"4529\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4530\" data-end=\"4600\"\u003eIndicates whether sample weight falls within defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1b1e0do\" data-start=\"4602\" data-end=\"4623\"\u003eIR Sensor Control\u003c\/h3\u003e\n\u003cp data-start=\"4624\" data-end=\"4712\"\u003eTouch-free infrared sensors allow users to operate the balance without physical contact.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"4714\" data-end=\"4731\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"4732\" data-end=\"4784\"\u003eSupports \u003cstrong data-start=\"4741\" data-end=\"4783\"\u003eGood Laboratory Practice documentation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4786\" data-end=\"4789\"\u003e\n\u003ch1 data-section-id=\"ggdxdk\" data-start=\"4791\" data-end=\"4810\"\u003eALIBI Data Memory\u003c\/h1\u003e\n\u003cp data-start=\"4812\" data-end=\"4911\"\u003eThe integrated \u003cstrong data-start=\"4827\" data-end=\"4899\"\u003eALIBI memory system automatically records up to 100,000 measurements\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"4913\" data-end=\"5021\"\u003e\n\u003cli data-section-id=\"fxyqbs\" data-start=\"4913\" data-end=\"4942\"\u003e\n\u003cp data-start=\"4915\" data-end=\"4942\"\u003eMeasurement date and time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l91jg3\" data-start=\"4943\" data-end=\"4966\"\u003e\n\u003cp data-start=\"4945\" data-end=\"4966\"\u003eMeasured mass value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rdpcox\" data-start=\"4967\" data-end=\"4981\"\u003e\n\u003cp data-start=\"4969\" data-end=\"4981\"\u003eTare value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z378kg\" data-start=\"4982\" data-end=\"5004\"\u003e\n\u003cp data-start=\"4984\" data-end=\"5004\"\u003eLogged-in operator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h4tn38\" data-start=\"5005\" data-end=\"5021\"\u003e\n\u003cp data-start=\"5007\" data-end=\"5021\"\u003eProduct name\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5023\" data-end=\"5100\"\u003eStored measurements cannot be manually deleted, ensuring secure traceability.\u003c\/p\u003e\n\u003chr data-start=\"5102\" data-end=\"5105\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5107\" data-end=\"5127\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5129\" data-end=\"5182\"\u003eThe Radwag MYA 2.5Y microbalance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"5184\" data-end=\"5401\"\u003e\n\u003cli data-section-id=\"1hipxyr\" data-start=\"5184\" data-end=\"5224\"\u003e\n\u003cp data-start=\"5186\" data-end=\"5224\"\u003ePharmaceutical research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qm6p7e\" data-start=\"5225\" data-end=\"5254\"\u003e\n\u003cp data-start=\"5227\" data-end=\"5254\"\u003eAnalytical chemistry labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"muciv2\" data-start=\"5255\" data-end=\"5304\"\u003e\n\u003cp data-start=\"5257\" data-end=\"5304\"\u003eNanotechnology and materials science research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cac3vx\" data-start=\"5305\" data-end=\"5330\"\u003e\n\u003cp data-start=\"5307\" data-end=\"5330\"\u003eMicro-sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xykno0\" data-start=\"5331\" data-end=\"5368\"\u003e\n\u003cp data-start=\"5333\" data-end=\"5368\"\u003eBiotechnology research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5369\" data-end=\"5401\"\u003e\n\u003cp data-start=\"5371\" data-end=\"5401\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5403\" data-end=\"5406\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5408\" data-end=\"5434\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5436\" data-end=\"5444\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5445\" data-end=\"5457\"\u003e\u003cstrong data-start=\"5445\" data-end=\"5457\"\u003eMYA 2.5Y\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5459\" data-end=\"5487\"\u003ePart Number: \u003cstrong data-start=\"5472\" data-end=\"5487\"\u003eWL-109-0004\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5489\" data-end=\"5492\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5494\" data-end=\"5516\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5518\" data-end=\"5546\"\u003eMaximum capacity\u003cbr data-start=\"5534\" data-end=\"5537\"\u003e\u003cstrong data-start=\"5537\" data-end=\"5546\"\u003e2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5548\" data-end=\"5573\"\u003eMinimum load\u003cbr data-start=\"5560\" data-end=\"5563\"\u003e\u003cstrong data-start=\"5563\" data-end=\"5573\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5575\" data-end=\"5597\"\u003eReadability\u003cbr data-start=\"5586\" data-end=\"5589\"\u003e\u003cstrong data-start=\"5589\" data-end=\"5597\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5599\" data-end=\"5622\"\u003eTare range\u003cbr data-start=\"5609\" data-end=\"5612\"\u003e\u003cstrong data-start=\"5612\" data-end=\"5622\"\u003e−2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5624\" data-end=\"5627\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5629\" data-end=\"5639\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5641\" data-end=\"5677\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5663\" data-end=\"5666\"\u003e\u003cstrong data-start=\"5666\" data-end=\"5677\"\u003e0.41 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5679\" data-end=\"5709\"\u003eRepeatability (Max)\u003cbr data-start=\"5698\" data-end=\"5701\"\u003e\u003cstrong data-start=\"5701\" data-end=\"5709\"\u003e1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5711\" data-end=\"5758\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"5745\" data-end=\"5748\"\u003e\u003cstrong data-start=\"5748\" data-end=\"5758\"\u003e0.8 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5760\" data-end=\"5804\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"5791\" data-end=\"5794\"\u003e\u003cstrong data-start=\"5794\" data-end=\"5804\"\u003e1.5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5806\" data-end=\"5827\"\u003eLinearity\u003cbr data-start=\"5815\" data-end=\"5818\"\u003e\u003cstrong data-start=\"5818\" data-end=\"5827\"\u003e±3 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5829\" data-end=\"5871\"\u003eStabilization time\u003cbr data-start=\"5847\" data-end=\"5850\"\u003e\u003cstrong data-start=\"5850\" data-end=\"5871\"\u003eMaximum 8 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5873\" data-end=\"5876\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"5878\" data-end=\"5901\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"5903\" data-end=\"5935\"\u003eUSP minimum weight\u003cbr data-start=\"5921\" data-end=\"5924\"\u003e\u003cstrong data-start=\"5924\" data-end=\"5935\"\u003e0.82 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5937\" data-end=\"5982\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"5967\" data-end=\"5970\"\u003e\u003cstrong data-start=\"5970\" data-end=\"5982\"\u003e0.082 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5984\" data-end=\"5987\"\u003e\n\u003ch1 data-section-id=\"1mcqff0\" data-start=\"5989\" data-end=\"6002\"\u003eCalibration\u003c\/h1\u003e\n\u003cp data-start=\"6004\" data-end=\"6037\"\u003e\u003cstrong data-start=\"6004\" data-end=\"6037\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6039\" data-end=\"6042\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"6044\" data-end=\"6065\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"6067\" data-end=\"6078\"\u003e\u003cstrong data-start=\"6067\" data-end=\"6078\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6080\" data-end=\"6083\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6085\" data-end=\"6094\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6096\" data-end=\"6139\"\u003e\u003cstrong data-start=\"6096\" data-end=\"6139\"\u003e10-inch touchscreen (ELLIPSIS terminal)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6141\" data-end=\"6144\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6146\" data-end=\"6160\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6162\" data-end=\"6195\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"6197\" data-end=\"6288\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"6197\" data-end=\"6211\"\u003e\n\u003cp data-start=\"6199\" data-end=\"6211\"\u003e\u003cstrong data-start=\"6199\" data-end=\"6211\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"6212\" data-end=\"6223\"\u003e\n\u003cp data-start=\"6214\" data-end=\"6223\"\u003e\u003cstrong data-start=\"6214\" data-end=\"6223\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"6224\" data-end=\"6234\"\u003e\n\u003cp data-start=\"6226\" data-end=\"6234\"\u003e\u003cstrong data-start=\"6226\" data-end=\"6234\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"6235\" data-end=\"6249\"\u003e\n\u003cp data-start=\"6237\" data-end=\"6249\"\u003e\u003cstrong data-start=\"6237\" data-end=\"6249\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"6250\" data-end=\"6261\"\u003e\n\u003cp data-start=\"6252\" data-end=\"6261\"\u003e\u003cstrong data-start=\"6252\" data-end=\"6261\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"6262\" data-end=\"6288\"\u003e\n\u003cp data-start=\"6264\" data-end=\"6288\"\u003e\u003cstrong data-start=\"6264\" data-end=\"6288\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6290\" data-end=\"6293\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6295\" data-end=\"6317\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6319\" data-end=\"6358\"\u003eOperating temperature\u003cbr data-start=\"6340\" data-end=\"6343\"\u003e\u003cstrong data-start=\"6343\" data-end=\"6358\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6360\" data-end=\"6405\"\u003eTemperature change rate\u003cbr data-start=\"6383\" data-end=\"6386\"\u003e\u003cstrong data-start=\"6386\" data-end=\"6405\"\u003e±0.3°C per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6407\" data-end=\"6440\"\u003eRelative humidity\u003cbr data-start=\"6424\" data-end=\"6427\"\u003e\u003cstrong data-start=\"6427\" data-end=\"6440\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6442\" data-end=\"6481\"\u003eHumidity change rate\u003cbr data-start=\"6462\" data-end=\"6465\"\u003e\u003cstrong data-start=\"6465\" data-end=\"6481\"\u003e±1% per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6483\" data-end=\"6486\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"6488\" data-end=\"6506\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"6508\" data-end=\"6534\"\u003ePan diameter\u003cbr data-start=\"6520\" data-end=\"6523\"\u003e\u003cstrong data-start=\"6523\" data-end=\"6534\"\u003e0.16 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6536\" data-end=\"6571\"\u003eChamber dimensions\u003cbr data-start=\"6554\" data-end=\"6557\"\u003e\u003cstrong data-start=\"6557\" data-end=\"6571\"\u003e90 × 90 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6573\" data-end=\"6576\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6578\" data-end=\"6599\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6601\" data-end=\"6666\"\u003ePackage dimensions\u003cbr data-start=\"6619\" data-end=\"6622\"\u003e\u003cstrong data-start=\"6622\" data-end=\"6666\"\u003e655 × 755 × 445 mm (26 × 30 × 18 inches)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6668\" data-end=\"6692\"\u003eUnit weight\u003cbr data-start=\"6679\" data-end=\"6682\"\u003e\u003cstrong data-start=\"6682\" data-end=\"6692\"\u003e20 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6694\" data-end=\"6722\"\u003eShipping weight\u003cbr data-start=\"6709\" data-end=\"6712\"\u003e\u003cstrong data-start=\"6712\" data-end=\"6722\"\u003e38 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6724\" data-end=\"6727\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6729\" data-end=\"6749\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6751\" data-end=\"6786\"\u003eAdapter\u003cbr data-start=\"6758\" data-end=\"6761\"\u003e\u003cstrong data-start=\"6761\" data-end=\"6786\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6788\" data-end=\"6817\"\u003eBalance input\u003cbr data-start=\"6801\" data-end=\"6804\"\u003e\u003cstrong data-start=\"6804\" data-end=\"6817\"\u003e12–15V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6819\" data-end=\"6822\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"6824\" data-end=\"6834\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"6836\" data-end=\"6868\"\u003e\u003cstrong data-start=\"6836\" data-end=\"6868\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282614481218,"sku":null,"price":22720.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/MYA_2.5Y__WL-109-0004_-removebg-preview.webp?v=1773590246"},{"product_id":"across-international-as-220-x7-radwag-220g-capacity-0-1mg-readability-o4-analytical-balance-as-x7","title":"Across International AS 220.X7 Radwag 220g Capacity 0.1mg Readability ø4\" Analytical Balance AS X7","description":"\u003ch2 data-section-id=\"almo08\" data-start=\"403\" data-end=\"486\"\u003eHigh-Precision Analytical Balance with SMARTLab System and Touchscreen Interface\u003c\/h2\u003e\n\u003cp data-start=\"488\" data-end=\"822\"\u003eThe \u003cstrong data-start=\"492\" data-end=\"531\"\u003eRadwag AS 220.X7 Analytical Balance\u003c\/strong\u003e is a high-performance laboratory weighing instrument designed for \u003cstrong data-start=\"598\" data-end=\"671\"\u003eprecise mass determination with 0.1 mg readability and 220 g capacity\u003c\/strong\u003e. Built for professional analytical applications, the AS X7 series delivers excellent repeatability, high resolution, and advanced measurement control.\u003c\/p\u003e\n\u003cp data-start=\"824\" data-end=\"1217\"\u003eDesigned for laboratories in \u003cstrong data-start=\"853\" data-end=\"929\"\u003epharmacy, chemistry, physics, biology, medicine, and research facilities\u003c\/strong\u003e, this analytical balance combines precision engineering with modern smart technologies. The balance features a \u003cstrong data-start=\"1041\" data-end=\"1174\"\u003ecolor touchscreen interface, internal automatic calibration, LevelSENSING system, and SMARTLab measurement supervision technology\u003c\/strong\u003e to ensure reliable and repeatable results.\u003c\/p\u003e\n\u003cp data-start=\"1219\" data-end=\"1409\"\u003eWith advanced connectivity including \u003cstrong data-start=\"1256\" data-end=\"1291\"\u003eUSB, RS232, Ethernet, and Wi-Fi\u003c\/strong\u003e, the AS 220.X7 integrates easily into modern laboratory information systems and digital data management environments.\u003c\/p\u003e\n\u003chr data-start=\"1411\" data-end=\"1414\"\u003e\n\u003ch1 data-section-id=\"6zrs6l\" data-start=\"1416\" data-end=\"1473\"\u003eKey Features of the Radwag AS 220.X7 Analytical Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"7q2mrz\" data-start=\"1475\" data-end=\"1513\"\u003eHigh-Precision Analytical Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1514\" data-end=\"1636\"\u003eProvides \u003cstrong data-start=\"1523\" data-end=\"1565\"\u003e220 g capacity with 0.1 mg readability\u003c\/strong\u003e, making it ideal for accurate laboratory measurements of small masses.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gf5gh2\" data-start=\"1638\" data-end=\"1669\"\u003eErgonomic Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"1670\" data-end=\"1794\"\u003eThe spacious weighing chamber allows easy access to the weighing pan and accommodates laboratory glassware of various sizes.\u003c\/p\u003e\n\u003cp data-start=\"1796\" data-end=\"1954\"\u003eThe new \u003cstrong data-start=\"1804\" data-end=\"1853\"\u003ealuminum base construction improves stability\u003c\/strong\u003e, while innovative mechanical design increases durability and reliability during long-term operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2o7ypr\" data-start=\"1956\" data-end=\"1987\"\u003eDual-CLICK Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"1988\" data-end=\"2118\"\u003eThe \u003cstrong data-start=\"1992\" data-end=\"2013\"\u003eDual-CLICK system\u003c\/strong\u003e allows tool-free assembly and disassembly of the weighing chamber, simplifying cleaning and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"2120\" data-end=\"2203\"\u003eSpecial rim-free pane guides help maintain cleanliness inside the weighing chamber.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cg08g8\" data-start=\"2205\" data-end=\"2234\"\u003eColor Touchscreen Display\u003c\/h3\u003e\n\u003cp data-start=\"2235\" data-end=\"2340\"\u003eThe modern \u003cstrong data-start=\"2246\" data-end=\"2275\"\u003ecolor touchscreen display\u003c\/strong\u003e allows intuitive operation even while wearing laboratory gloves.\u003c\/p\u003e\n\u003cp data-start=\"2342\" data-end=\"2485\"\u003eCustomizable widgets and configurable buttons allow users to personalize the interface for faster access to frequently used weighing functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8umyam\" data-start=\"2487\" data-end=\"2510\"\u003eLevelSENSING System\u003c\/h3\u003e\n\u003cp data-start=\"2511\" data-end=\"2648\"\u003eThe integrated \u003cstrong data-start=\"2526\" data-end=\"2549\"\u003eLevelSENSING system\u003c\/strong\u003e monitors tilt using built-in sensors and displays a graphical warning if the balance is not level.\u003c\/p\u003e\n\u003cp data-start=\"2650\" data-end=\"2748\"\u003eThis ensures compliance with \u003cstrong data-start=\"2679\" data-end=\"2707\"\u003eGLP and GMP requirements\u003c\/strong\u003e while improving measurement reliability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1felwie\" data-start=\"2750\" data-end=\"2784\"\u003eInternal Automatic Calibration\u003c\/h3\u003e\n\u003cp data-start=\"2785\" data-end=\"2924\"\u003eInternal automatic adjustment compensates for environmental changes and ensures high accuracy even under challenging laboratory conditions.\u003c\/p\u003e\n\u003chr data-start=\"2926\" data-end=\"2929\"\u003e\n\u003ch1 data-section-id=\"1ws28l4\" data-start=\"2931\" data-end=\"2972\"\u003eSMARTLab Intelligent Measurement System\u003c\/h1\u003e\n\u003cp data-start=\"2974\" data-end=\"3085\"\u003eThe \u003cstrong data-start=\"2978\" data-end=\"2997\"\u003eSMARTLab system\u003c\/strong\u003e supervises the weighing process and reduces measurement errors caused by human factors.\u003c\/p\u003e\n\u003ch3 data-section-id=\"710qs4\" data-start=\"3087\" data-end=\"3111\"\u003eAutomatic Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3112\" data-end=\"3220\"\u003eInternal calibration automatically compensates for environmental changes and maintains measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o1yr05\" data-start=\"3222\" data-end=\"3245\"\u003eData Access Control\u003c\/h3\u003e\n\u003cp data-start=\"3246\" data-end=\"3343\"\u003eUser access is managed through multiple permission levels controlled by the system administrator.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1bdb61b\" data-start=\"3345\" data-end=\"3369\"\u003eTouch-Free Operation\u003c\/h3\u003e\n\u003cp data-start=\"3370\" data-end=\"3487\"\u003eProgrammable sensors allow contactless operation of selected functions to improve workflow and prevent contamination.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ndwwwh\" data-start=\"3489\" data-end=\"3519\"\u003eAutomatic Weighing Records\u003c\/h3\u003e\n\u003cp data-start=\"3520\" data-end=\"3633\"\u003eMeasurement reports and weighing records can be automatically generated and exported to external devices via USB.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3635\" data-end=\"3651\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3652\" data-end=\"3775\"\u003eIntegrated \u003cstrong data-start=\"3663\" data-end=\"3710\"\u003eALIBI memory stores up to 500,000 weighings\u003c\/strong\u003e, ensuring long-term traceability and secure measurement records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tmn3z3\" data-start=\"3777\" data-end=\"3799\"\u003eWi-Fi Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3800\" data-end=\"3903\"\u003eBalances can be remotely controlled via devices running \u003cstrong data-start=\"3856\" data-end=\"3884\"\u003eAndroid, iOS, or Windows\u003c\/strong\u003e operating systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11v9zm\" data-start=\"3905\" data-end=\"3938\"\u003eAmbient Conditions Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"3939\" data-end=\"4077\"\u003eThe balance can communicate with a \u003cstrong data-start=\"3974\" data-end=\"4007\"\u003eRADWAG thermo-hygro-barometer\u003c\/strong\u003e to monitor environmental conditions such as temperature and humidity.\u003c\/p\u003e\n\u003chr data-start=\"4079\" data-end=\"4082\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"4084\" data-end=\"4119\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"4121\" data-end=\"4225\"\u003eThe AS X7 series includes a comprehensive database system supporting multi-user laboratory environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"4227\" data-end=\"4248\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"4250\" data-end=\"4574\"\u003e\n\u003cli data-section-id=\"b33a4d\" data-start=\"4250\" data-end=\"4279\"\u003e\n\u003cp data-start=\"4252\" data-end=\"4279\"\u003e\u003cstrong data-start=\"4252\" data-end=\"4265\"\u003eProducts:\u003c\/strong\u003e up to 5,000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k43mgv\" data-start=\"4280\" data-end=\"4304\"\u003e\n\u003cp data-start=\"4282\" data-end=\"4304\"\u003e\u003cstrong data-start=\"4282\" data-end=\"4292\"\u003eUsers:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cyfqnd\" data-start=\"4305\" data-end=\"4339\"\u003e\n\u003cp data-start=\"4307\" data-end=\"4339\"\u003e\u003cstrong data-start=\"4307\" data-end=\"4327\"\u003ePackaging types:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2wr2gm\" data-start=\"4340\" data-end=\"4370\"\u003e\n\u003cp data-start=\"4342\" data-end=\"4370\"\u003e\u003cstrong data-start=\"4342\" data-end=\"4356\"\u003eCustomers:\u003c\/strong\u003e up to 1,000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10dobr0\" data-start=\"4371\" data-end=\"4402\"\u003e\n\u003cp data-start=\"4373\" data-end=\"4402\"\u003e\u003cstrong data-start=\"4373\" data-end=\"4390\"\u003eFormulations:\u003c\/strong\u003e up to 100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nhfhhy\" data-start=\"4403\" data-end=\"4441\"\u003e\n\u003cp data-start=\"4405\" data-end=\"4441\"\u003e\u003cstrong data-start=\"4405\" data-end=\"4429\"\u003eFormulation reports:\u003c\/strong\u003e up to 500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"sl9sgn\" data-start=\"4442\" data-end=\"4490\"\u003e\n\u003cp data-start=\"4444\" data-end=\"4490\"\u003e\u003cstrong data-start=\"4444\" data-end=\"4467\"\u003eAmbient conditions:\u003c\/strong\u003e up to 10,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11gcgwc\" data-start=\"4491\" data-end=\"4530\"\u003e\n\u003cp data-start=\"4493\" data-end=\"4530\"\u003e\u003cstrong data-start=\"4493\" data-end=\"4507\"\u003eWeighings:\u003c\/strong\u003e up to 50,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vrmwae\" data-start=\"4531\" data-end=\"4574\"\u003e\n\u003cp data-start=\"4533\" data-end=\"4574\"\u003e\u003cstrong data-start=\"4533\" data-end=\"4550\"\u003eALIBI memory:\u003c\/strong\u003e up to 512,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4576\" data-end=\"4668\"\u003eThese databases enable advanced analysis and traceability of laboratory weighing operations.\u003c\/p\u003e\n\u003chr data-start=\"4670\" data-end=\"4673\"\u003e\n\u003ch1 data-section-id=\"1409pu0\" data-start=\"4675\" data-end=\"4707\"\u003eCommunication and Connectivity\u003c\/h1\u003e\n\u003cp data-start=\"4709\" data-end=\"4785\"\u003eThe AS 220.X7 analytical balance supports multiple communication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4787\" data-end=\"4849\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"4787\" data-end=\"4798\"\u003e\n\u003cp data-start=\"4789\" data-end=\"4798\"\u003e\u003cstrong data-start=\"4789\" data-end=\"4798\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4799\" data-end=\"4810\"\u003e\n\u003cp data-start=\"4801\" data-end=\"4810\"\u003e\u003cstrong data-start=\"4801\" data-end=\"4810\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4811\" data-end=\"4822\"\u003e\n\u003cp data-start=\"4813\" data-end=\"4822\"\u003e\u003cstrong data-start=\"4813\" data-end=\"4822\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"4823\" data-end=\"4837\"\u003e\n\u003cp data-start=\"4825\" data-end=\"4837\"\u003e\u003cstrong data-start=\"4825\" data-end=\"4837\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"4838\" data-end=\"4849\"\u003e\n\u003cp data-start=\"4840\" data-end=\"4849\"\u003e\u003cstrong data-start=\"4840\" data-end=\"4849\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4851\" data-end=\"4930\"\u003eA front USB port enables fast data transfer and connection of external devices.\u003c\/p\u003e\n\u003cp data-start=\"4932\" data-end=\"5025\"\u003eThe balance also includes a \u003cstrong data-start=\"4960\" data-end=\"4984\"\u003eKensington Lock slot\u003c\/strong\u003e to protect against unauthorized removal.\u003c\/p\u003e\n\u003chr data-start=\"5027\" data-end=\"5030\"\u003e\n\u003ch1 data-section-id=\"n50ff3\" data-start=\"5032\" data-end=\"5051\"\u003eOptional Features\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1flezpk\" data-start=\"5053\" data-end=\"5075\"\u003eUnder-Pan Weighing\u003c\/h3\u003e\n\u003cp data-start=\"5076\" data-end=\"5180\"\u003eBalances manufactured after February 15, 2023 support under-pan weighing via an optional dedicated hook.\u003c\/p\u003e\n\u003ch3 data-section-id=\"z7ltoy\" data-start=\"5182\" data-end=\"5219\"\u003eTHBR 2.0 Environmental Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"5220\" data-end=\"5305\"\u003eCompatible with the \u003cstrong data-start=\"5240\" data-end=\"5259\"\u003eTHBR 2.0 system\u003c\/strong\u003e for monitoring ambient laboratory conditions.\u003c\/p\u003e\n\u003chr data-start=\"5307\" data-end=\"5310\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"5312\" data-end=\"5332\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"5334\" data-end=\"5392\"\u003eThe Radwag AS 220.X7 analytical balance is widely used in:\u003c\/p\u003e\n\u003cul data-start=\"5394\" data-end=\"5588\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"5394\" data-end=\"5425\"\u003e\n\u003cp data-start=\"5396\" data-end=\"5425\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"5426\" data-end=\"5460\"\u003e\n\u003cp data-start=\"5428\" data-end=\"5460\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"5461\" data-end=\"5493\"\u003e\n\u003cp data-start=\"5463\" data-end=\"5493\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1025s12\" data-start=\"5494\" data-end=\"5518\"\u003e\n\u003cp data-start=\"5496\" data-end=\"5518\"\u003eMedical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13nz5hj\" data-start=\"5519\" data-end=\"5551\"\u003e\n\u003cp data-start=\"5521\" data-end=\"5551\"\u003eQuality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2x2yph\" data-start=\"5552\" data-end=\"5588\"\u003e\n\u003cp data-start=\"5554\" data-end=\"5588\"\u003eScientific research institutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5590\" data-end=\"5593\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5595\" data-end=\"5621\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5623\" data-end=\"5631\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5632\" data-end=\"5645\"\u003e\u003cstrong data-start=\"5632\" data-end=\"5645\"\u003eAS 220.X7\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5647\" data-end=\"5675\"\u003ePart Number: \u003cstrong data-start=\"5660\" data-end=\"5675\"\u003eWL-113-0004\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5677\" data-end=\"5680\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5682\" data-end=\"5704\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5706\" data-end=\"5734\"\u003eMaximum capacity\u003cbr data-start=\"5722\" data-end=\"5725\"\u003e\u003cstrong data-start=\"5725\" data-end=\"5734\"\u003e220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5736\" data-end=\"5760\"\u003eMinimum load\u003cbr data-start=\"5748\" data-end=\"5751\"\u003e\u003cstrong data-start=\"5751\" data-end=\"5760\"\u003e10 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5762\" data-end=\"5786\"\u003eReadability\u003cbr data-start=\"5773\" data-end=\"5776\"\u003e\u003cstrong data-start=\"5776\" data-end=\"5786\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5788\" data-end=\"5820\"\u003eVerification unit (e)\u003cbr data-start=\"5809\" data-end=\"5812\"\u003e\u003cstrong data-start=\"5812\" data-end=\"5820\"\u003e1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5822\" data-end=\"5845\"\u003eTare range\u003cbr data-start=\"5832\" data-end=\"5835\"\u003e\u003cstrong data-start=\"5835\" data-end=\"5845\"\u003e−220 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5847\" data-end=\"5850\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5852\" data-end=\"5862\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5864\" data-end=\"5900\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5886\" data-end=\"5889\"\u003e\u003cstrong data-start=\"5889\" data-end=\"5900\"\u003e0.06 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5902\" data-end=\"5935\"\u003eRepeatability (Max)\u003cbr data-start=\"5921\" data-end=\"5924\"\u003e\u003cstrong data-start=\"5924\" data-end=\"5935\"\u003e0.07 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5937\" data-end=\"5985\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"5971\" data-end=\"5974\"\u003e\u003cstrong data-start=\"5974\" data-end=\"5985\"\u003e0.09 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5987\" data-end=\"6031\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"6018\" data-end=\"6021\"\u003e\u003cstrong data-start=\"6021\" data-end=\"6031\"\u003e0.1 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6033\" data-end=\"6056\"\u003eLinearity\u003cbr data-start=\"6042\" data-end=\"6045\"\u003e\u003cstrong data-start=\"6045\" data-end=\"6056\"\u003e±0.2 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6058\" data-end=\"6092\"\u003eStabilization time\u003cbr data-start=\"6076\" data-end=\"6079\"\u003e\u003cstrong data-start=\"6079\" data-end=\"6092\"\u003e2 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6094\" data-end=\"6097\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"6099\" data-end=\"6122\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"6124\" data-end=\"6155\"\u003eUSP minimum weight\u003cbr data-start=\"6142\" data-end=\"6145\"\u003e\u003cstrong data-start=\"6145\" data-end=\"6155\"\u003e120 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6157\" data-end=\"6199\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"6187\" data-end=\"6190\"\u003e\u003cstrong data-start=\"6190\" data-end=\"6199\"\u003e12 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6201\" data-end=\"6204\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"6206\" data-end=\"6215\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"6217\" data-end=\"6249\"\u003e\u003cstrong data-start=\"6217\" data-end=\"6249\"\u003eCapacitive color touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6251\" data-end=\"6254\"\u003e\n\u003ch1 data-section-id=\"k51ikt\" data-start=\"6256\" data-end=\"6270\"\u003eWeighing Pan\u003c\/h1\u003e\n\u003cp data-start=\"6272\" data-end=\"6304\"\u003eDiameter\u003cbr data-start=\"6280\" data-end=\"6283\"\u003e\u003cstrong data-start=\"6283\" data-end=\"6304\"\u003e4 inches (100 mm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6306\" data-end=\"6336\"\u003eMaterial\u003cbr data-start=\"6314\" data-end=\"6317\"\u003e\u003cstrong data-start=\"6317\" data-end=\"6336\"\u003eStainless steel\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6338\" data-end=\"6341\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"6343\" data-end=\"6357\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"6359\" data-end=\"6384\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"6386\" data-end=\"6448\"\u003e\n\u003cli data-section-id=\"12ca6ca\" data-start=\"6386\" data-end=\"6397\"\u003e\n\u003cp data-start=\"6388\" data-end=\"6397\"\u003e\u003cstrong data-start=\"6388\" data-end=\"6397\"\u003eRS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"6398\" data-end=\"6409\"\u003e\n\u003cp data-start=\"6400\" data-end=\"6409\"\u003e\u003cstrong data-start=\"6400\" data-end=\"6409\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"6410\" data-end=\"6421\"\u003e\n\u003cp data-start=\"6412\" data-end=\"6421\"\u003e\u003cstrong data-start=\"6412\" data-end=\"6421\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"6422\" data-end=\"6436\"\u003e\n\u003cp data-start=\"6424\" data-end=\"6436\"\u003e\u003cstrong data-start=\"6424\" data-end=\"6436\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"6437\" data-end=\"6448\"\u003e\n\u003cp data-start=\"6439\" data-end=\"6448\"\u003e\u003cstrong data-start=\"6439\" data-end=\"6448\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6450\" data-end=\"6453\"\u003e\n\u003ch1 data-section-id=\"1u9wndv\" data-start=\"6455\" data-end=\"6464\"\u003eSensors\u003c\/h1\u003e\n\u003cp data-start=\"6466\" data-end=\"6513\"\u003e\u003cstrong data-start=\"6466\" data-end=\"6513\"\u003e2 infrared sensors for touch-free operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6515\" data-end=\"6518\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6520\" data-end=\"6540\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6542\" data-end=\"6567\"\u003e\u003cstrong data-start=\"6542\" data-end=\"6567\"\u003e100–240 VAC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6569\" data-end=\"6607\"\u003eMaximum power consumption\u003cbr data-start=\"6594\" data-end=\"6597\"\u003e\u003cstrong data-start=\"6597\" data-end=\"6607\"\u003e250 mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6609\" data-end=\"6612\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"6614\" data-end=\"6636\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"6638\" data-end=\"6677\"\u003eOperating temperature\u003cbr data-start=\"6659\" data-end=\"6662\"\u003e\u003cstrong data-start=\"6662\" data-end=\"6677\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6679\" data-end=\"6682\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6684\" data-end=\"6705\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6707\" data-end=\"6757\"\u003ePackage dimensions\u003cbr data-start=\"6725\" data-end=\"6728\"\u003e\u003cstrong data-start=\"6728\" data-end=\"6757\"\u003e19.5 × 15.5 × 20.5 inches\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6759\" data-end=\"6783\"\u003eUnit weight\u003cbr data-start=\"6770\" data-end=\"6773\"\u003e\u003cstrong data-start=\"6773\" data-end=\"6783\"\u003e16 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6785\" data-end=\"6813\"\u003eShipping weight\u003cbr data-start=\"6800\" data-end=\"6803\"\u003e\u003cstrong data-start=\"6803\" data-end=\"6813\"\u003e21 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6815\" data-end=\"6818\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"6820\" data-end=\"6841\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"6843\" data-end=\"7011\"\u003e\n\u003cli data-section-id=\"1b4l0n5\" data-start=\"6843\" data-end=\"6886\"\u003e\n\u003cp data-start=\"6845\" data-end=\"6886\"\u003eRadwag AS 220.X7 Analytical Balance – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yfw4sv\" data-start=\"6887\" data-end=\"6918\"\u003e\n\u003cp data-start=\"6889\" data-end=\"6918\"\u003eUniversal Power Adapter – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19f3x1w\" data-start=\"6919\" data-end=\"6947\"\u003e\n\u003cp data-start=\"6921\" data-end=\"6947\"\u003eDraft Shield for Pan – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qbmtyj\" data-start=\"6948\" data-end=\"6968\"\u003e\n\u003cp data-start=\"6950\" data-end=\"6968\"\u003ePan Assembly – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1isa1dl\" data-start=\"6969\" data-end=\"6988\"\u003e\n\u003cp data-start=\"6971\" data-end=\"6988\"\u003eBalance Pad – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1he28qg\" data-start=\"6989\" data-end=\"7011\"\u003e\n\u003cp data-start=\"6991\" data-end=\"7011\"\u003eStart-Up Guide – 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7013\" data-end=\"7016\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"7018\" data-end=\"7028\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"7030\" data-end=\"7062\"\u003e\u003cstrong data-start=\"7030\" data-end=\"7062\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282620936514,"sku":null,"price":2685.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/radwag_AS_X7_levelsensing4.png?v=1773590464"},{"product_id":"across-international-ps-8100-r2-m-radwag-r2-series-8100g-capacity-0-01g-readability-8x8-precision-balance","title":"Across International PS 8100.R2.M Radwag R2 Series 8100g Capacity 0.01g Readability 8x8\" Precision Balance","description":"\u003ch2 data-section-id=\"15h0z5c\" data-start=\"396\" data-end=\"483\"\u003eHigh-Resolution Precision Balance with MONOBLOCK Technology and Internal Calibration\u003c\/h2\u003e\n\u003cp data-start=\"485\" data-end=\"825\"\u003eThe \u003cstrong data-start=\"489\" data-end=\"530\"\u003eRadwag PS 8100.R2.M Precision Balance\u003c\/strong\u003e is a high-resolution laboratory balance designed for \u003cstrong data-start=\"584\" data-end=\"652\"\u003eaccurate mass determination up to 8100 g with 0.01 g readability\u003c\/strong\u003e. Built using advanced \u003cstrong data-start=\"675\" data-end=\"715\"\u003eRADWAG MONOBLOCK weighing technology\u003c\/strong\u003e, this precision balance delivers exceptional stability, measurement repeatability, and long-term reliability.\u003c\/p\u003e\n\u003cp data-start=\"827\" data-end=\"1163\"\u003eThe innovative \u003cstrong data-start=\"842\" data-end=\"888\"\u003esingle-point weighing pan fastening system\u003c\/strong\u003e ensures optimal weighing geometry while minimizing eccentricity errors. Additionally, the \u003cstrong data-start=\"979\" data-end=\"1015\"\u003elabyrinth-style fastening design\u003c\/strong\u003e protects the weighing mechanism from contamination, increasing durability and ensuring consistent performance in demanding laboratory environments.\u003c\/p\u003e\n\u003cp data-start=\"1165\" data-end=\"1364\"\u003eEquipped with \u003cstrong data-start=\"1179\" data-end=\"1212\"\u003eautomatic internal adjustment\u003c\/strong\u003e, the PS 8100.R2.M maintains high accuracy across the entire measuring range, compensating for environmental changes and ensuring reliable measurements.\u003c\/p\u003e\n\u003cp data-start=\"1366\" data-end=\"1565\"\u003eWith integrated \u003cstrong data-start=\"1382\" data-end=\"1448\"\u003edatabases, ALIBI memory, and multiple communication interfaces\u003c\/strong\u003e, this precision balance integrates easily with laboratory data management systems and industrial weighing workflows.\u003c\/p\u003e\n\u003chr data-start=\"1567\" data-end=\"1570\"\u003e\n\u003ch1 data-section-id=\"1sj2lpz\" data-start=\"1572\" data-end=\"1631\"\u003eKey Features of the Radwag PS 8100.R2.M Precision Balance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"8ufiw7\" data-start=\"1633\" data-end=\"1673\"\u003eHigh-Resolution Weighing Performance\u003c\/h3\u003e\n\u003cp data-start=\"1674\" data-end=\"1828\"\u003eProvides \u003cstrong data-start=\"1683\" data-end=\"1734\"\u003e8100 g maximum capacity with 0.01 g readability\u003c\/strong\u003e, making it suitable for precise laboratory measurements and industrial weighing applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"pl8rlq\" data-start=\"1830\" data-end=\"1863\"\u003eMONOBLOCK Weighing Technology\u003c\/h3\u003e\n\u003cp data-start=\"1864\" data-end=\"1917\"\u003eAdvanced \u003cstrong data-start=\"1873\" data-end=\"1907\"\u003eMONOBLOCK load cell technology\u003c\/strong\u003e provides:\u003c\/p\u003e\n\u003cul data-start=\"1919\" data-end=\"2042\"\u003e\n\u003cli data-section-id=\"nnzkd5\" data-start=\"1919\" data-end=\"1953\"\u003e\n\u003cp data-start=\"1921\" data-end=\"1953\"\u003eImproved measurement stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ifp1ty\" data-start=\"1954\" data-end=\"2001\"\u003e\n\u003cp data-start=\"1956\" data-end=\"2001\"\u003eHigh resistance to environmental conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p3uwxu\" data-start=\"2002\" data-end=\"2042\"\u003e\n\u003cp data-start=\"2004\" data-end=\"2042\"\u003eLong-term repeatability and accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1eug8ab\" data-start=\"2044\" data-end=\"2077\"\u003eInternal Automatic Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"2078\" data-end=\"2195\"\u003eInternal calibration using an integrated reference mass ensures accurate measurements across the full weighing range.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ye59w6\" data-start=\"2197\" data-end=\"2226\"\u003eDurable Mechanical Design\u003c\/h3\u003e\n\u003cp data-start=\"2227\" data-end=\"2304\"\u003eThe rigid base structure improves balance stability and resistance to shocks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"owdhd4\" data-start=\"2306\" data-end=\"2343\"\u003eContamination-Resistant Pan Mount\u003c\/h3\u003e\n\u003cp data-start=\"2344\" data-end=\"2446\"\u003eA \u003cstrong data-start=\"2346\" data-end=\"2386\"\u003elabyrinth-style pan fastening system\u003c\/strong\u003e prevents contamination and protects the weighing mechanism.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2a8xam\" data-start=\"2448\" data-end=\"2469\"\u003eClear LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"2470\" data-end=\"2574\"\u003eThe balance features a \u003cstrong data-start=\"2493\" data-end=\"2516\"\u003ebacklit LCD display\u003c\/strong\u003e that provides clear and easy-to-read measurement results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"2bc4pe\" data-start=\"2576\" data-end=\"2602\"\u003eQuick Access Operation\u003c\/h3\u003e\n\u003cp data-start=\"2603\" data-end=\"2700\"\u003eDedicated function keys allow fast access to commonly used weighing modes and database functions.\u003c\/p\u003e\n\u003chr data-start=\"2702\" data-end=\"2705\"\u003e\n\u003ch1 data-section-id=\"1fqll5j\" data-start=\"2707\" data-end=\"2742\"\u003eIntegrated Data Management System\u003c\/h1\u003e\n\u003cp data-start=\"2744\" data-end=\"2874\"\u003eThe PS R2.M precision balance series includes an internal data management system designed for laboratory and industrial workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16p4s6v\" data-start=\"2876\" data-end=\"2897\"\u003eDatabase Capacity\u003c\/h3\u003e\n\u003cul data-start=\"2899\" data-end=\"3048\"\u003e\n\u003cli data-section-id=\"bsi9cc\" data-start=\"2899\" data-end=\"2933\"\u003e\n\u003cp data-start=\"2901\" data-end=\"2933\"\u003e\u003cstrong data-start=\"2901\" data-end=\"2915\"\u003eOperators:\u003c\/strong\u003e up to 100 users\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xxohr5\" data-start=\"2934\" data-end=\"2972\"\u003e\n\u003cp data-start=\"2936\" data-end=\"2972\"\u003e\u003cstrong data-start=\"2936\" data-end=\"2949\"\u003eProducts:\u003c\/strong\u003e up to 1,000 products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wgf81o\" data-start=\"2973\" data-end=\"3011\"\u003e\n\u003cp data-start=\"2975\" data-end=\"3011\"\u003e\u003cstrong data-start=\"2975\" data-end=\"2989\"\u003eWeighings:\u003c\/strong\u003e up to 5,000 records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mvd6fq\" data-start=\"3012\" data-end=\"3048\"\u003e\n\u003cp data-start=\"3014\" data-end=\"3048\"\u003e\u003cstrong data-start=\"3014\" data-end=\"3024\"\u003eTares:\u003c\/strong\u003e up to 100 tare values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12vuh7s\" data-start=\"3050\" data-end=\"3066\"\u003eALIBI Memory\u003c\/h3\u003e\n\u003cp data-start=\"3068\" data-end=\"3203\"\u003eIntegrated \u003cstrong data-start=\"3079\" data-end=\"3133\"\u003eALIBI memory stores up to 100,000 weighing records\u003c\/strong\u003e, ensuring secure measurement traceability and long-term data storage.\u003c\/p\u003e\n\u003chr data-start=\"3205\" data-end=\"3208\"\u003e\n\u003ch1 data-section-id=\"o2lmlh\" data-start=\"3210\" data-end=\"3240\"\u003eCommunication \u0026amp; Connectivity\u003c\/h1\u003e\n\u003cp data-start=\"3242\" data-end=\"3365\"\u003eThe PS 8100.R2.M balance supports multiple communication interfaces for integration with laboratory and industrial systems.\u003c\/p\u003e\n\u003cp data-start=\"3367\" data-end=\"3400\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"3402\" data-end=\"3485\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"3402\" data-end=\"3417\"\u003e\n\u003cp data-start=\"3404\" data-end=\"3417\"\u003e\u003cstrong data-start=\"3404\" data-end=\"3417\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b967qt\" data-start=\"3418\" data-end=\"3434\"\u003e\n\u003cp data-start=\"3420\" data-end=\"3434\"\u003e\u003cstrong data-start=\"3420\" data-end=\"3434\"\u003eUSB Type A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b966uu\" data-start=\"3435\" data-end=\"3451\"\u003e\n\u003cp data-start=\"3437\" data-end=\"3451\"\u003e\u003cstrong data-start=\"3437\" data-end=\"3451\"\u003eUSB Type B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"cq3jcv\" data-start=\"3452\" data-end=\"3485\"\u003e\n\u003cp data-start=\"3454\" data-end=\"3485\"\u003e\u003cstrong data-start=\"3454\" data-end=\"3485\"\u003eOptional Wi-Fi connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3487\" data-end=\"3575\"\u003eThe balance can connect to printers, computers, USB flash drives, and external displays.\u003c\/p\u003e\n\u003chr data-start=\"3577\" data-end=\"3580\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"3582\" data-end=\"3602\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"3604\" data-end=\"3666\"\u003eThe Radwag PS 8100.R2.M precision balance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"3668\" data-end=\"3863\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"3668\" data-end=\"3699\"\u003e\n\u003cp data-start=\"3670\" data-end=\"3699\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bsn81n\" data-start=\"3700\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3702\" data-end=\"3734\"\u003eChemical analysis laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fivdhh\" data-start=\"3735\" data-end=\"3765\"\u003e\n\u003cp data-start=\"3737\" data-end=\"3765\"\u003eIndustrial quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mg28tq\" data-start=\"3766\" data-end=\"3796\"\u003e\n\u003cp data-start=\"3768\" data-end=\"3796\"\u003eManufacturing environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12r2wnr\" data-start=\"3797\" data-end=\"3829\"\u003e\n\u003cp data-start=\"3799\" data-end=\"3829\"\u003eAcademic research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1apzouo\" data-start=\"3830\" data-end=\"3863\"\u003e\n\u003cp data-start=\"3832\" data-end=\"3863\"\u003eMaterial testing laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3865\" data-end=\"3868\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3870\" data-end=\"3896\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3898\" data-end=\"3906\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3907\" data-end=\"3923\"\u003e\u003cstrong data-start=\"3907\" data-end=\"3923\"\u003ePS 8100.R2.M\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3925\" data-end=\"3928\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"3930\" data-end=\"3952\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"3954\" data-end=\"3983\"\u003eMaximum capacity\u003cbr data-start=\"3970\" data-end=\"3973\"\u003e\u003cstrong data-start=\"3973\" data-end=\"3983\"\u003e8100 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3985\" data-end=\"4009\"\u003eMinimum load\u003cbr data-start=\"3997\" data-end=\"4000\"\u003e\u003cstrong data-start=\"4000\" data-end=\"4009\"\u003e0.5 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4011\" data-end=\"4035\"\u003eReadability\u003cbr data-start=\"4022\" data-end=\"4025\"\u003e\u003cstrong data-start=\"4025\" data-end=\"4035\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4037\" data-end=\"4080\"\u003eVerification scale interval (e)\u003cbr data-start=\"4068\" data-end=\"4071\"\u003e\u003cstrong data-start=\"4071\" data-end=\"4080\"\u003e0.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4082\" data-end=\"4106\"\u003eTare range\u003cbr data-start=\"4092\" data-end=\"4095\"\u003e\u003cstrong data-start=\"4095\" data-end=\"4106\"\u003e−8100 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4108\" data-end=\"4111\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"4113\" data-end=\"4123\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"4125\" data-end=\"4157\"\u003eRepeatability (Max)\u003cbr data-start=\"4144\" data-end=\"4147\"\u003e\u003cstrong data-start=\"4147\" data-end=\"4157\"\u003e0.01 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4159\" data-end=\"4195\"\u003eRepeatability (5% Max)\u003cbr data-start=\"4181\" data-end=\"4184\"\u003e\u003cstrong data-start=\"4184\" data-end=\"4195\"\u003e0.005 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4197\" data-end=\"4220\"\u003eLinearity\u003cbr data-start=\"4206\" data-end=\"4209\"\u003e\u003cstrong data-start=\"4209\" data-end=\"4220\"\u003e±0.03 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4222\" data-end=\"4258\"\u003eStabilization time\u003cbr data-start=\"4240\" data-end=\"4243\"\u003e\u003cstrong data-start=\"4243\" data-end=\"4258\"\u003e1.5 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4260\" data-end=\"4263\"\u003e\n\u003ch1 data-section-id=\"is2qae\" data-start=\"4265\" data-end=\"4288\"\u003eMinimum Sample Weight\u003c\/h1\u003e\n\u003cp data-start=\"4290\" data-end=\"4321\"\u003eMinimum weight (USP)\u003cbr data-start=\"4310\" data-end=\"4313\"\u003e\u003cstrong data-start=\"4313\" data-end=\"4321\"\u003e10 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4323\" data-end=\"4363\"\u003eMinimum weight (U = 1%, k = 2)\u003cbr data-start=\"4353\" data-end=\"4356\"\u003e\u003cstrong data-start=\"4356\" data-end=\"4363\"\u003e1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4365\" data-end=\"4368\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"4370\" data-end=\"4382\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"4384\" data-end=\"4418\"\u003e\u003cstrong data-start=\"4384\" data-end=\"4418\"\u003eInternal automatic calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4420\" data-end=\"4423\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"4425\" data-end=\"4446\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"4448\" data-end=\"4460\"\u003e\u003cstrong data-start=\"4448\" data-end=\"4460\"\u003eClass II\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4462\" data-end=\"4465\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4467\" data-end=\"4476\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4478\" data-end=\"4501\"\u003e\u003cstrong data-start=\"4478\" data-end=\"4501\"\u003eBacklit LCD display\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4503\" data-end=\"4506\"\u003e\n\u003ch1 data-section-id=\"15ol7sd\" data-start=\"4508\" data-end=\"4527\"\u003eWeighing Platform\u003c\/h1\u003e\n\u003cp data-start=\"4529\" data-end=\"4573\"\u003eDimensions\u003cbr data-start=\"4539\" data-end=\"4542\"\u003e\u003cstrong data-start=\"4542\" data-end=\"4573\"\u003e195 × 195 mm (8 × 8 inches)\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4575\" data-end=\"4578\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4580\" data-end=\"4594\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4596\" data-end=\"4621\"\u003eCommunication interfaces:\u003c\/p\u003e\n\u003cul data-start=\"4623\" data-end=\"4683\"\u003e\n\u003cli data-section-id=\"fdkqn\" data-start=\"4623\" data-end=\"4638\"\u003e\n\u003cp data-start=\"4625\" data-end=\"4638\"\u003e\u003cstrong data-start=\"4625\" data-end=\"4638\"\u003e2 × RS232\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq3wg\" data-start=\"4639\" data-end=\"4650\"\u003e\n\u003cp data-start=\"4641\" data-end=\"4650\"\u003e\u003cstrong data-start=\"4641\" data-end=\"4650\"\u003eUSB-A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq4oz\" data-start=\"4651\" data-end=\"4662\"\u003e\n\u003cp data-start=\"4653\" data-end=\"4662\"\u003e\u003cstrong data-start=\"4653\" data-end=\"4662\"\u003eUSB-B\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzl5cq\" data-start=\"4663\" data-end=\"4683\"\u003e\n\u003cp data-start=\"4665\" data-end=\"4683\"\u003e\u003cstrong data-start=\"4665\" data-end=\"4683\"\u003eOptional Wi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4685\" data-end=\"4688\"\u003e\n\u003ch1 data-section-id=\"4ug2xq\" data-start=\"4690\" data-end=\"4716\"\u003eEnvironmental Conditions\u003c\/h1\u003e\n\u003cp data-start=\"4718\" data-end=\"4760\"\u003eOperating temperature\u003cbr data-start=\"4739\" data-end=\"4742\"\u003e\u003cstrong data-start=\"4742\" data-end=\"4760\"\u003e+10°C to +40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4762\" data-end=\"4802\"\u003eStorage temperature\u003cbr data-start=\"4781\" data-end=\"4784\"\u003e\u003cstrong data-start=\"4784\" data-end=\"4802\"\u003e−20°C to +50°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4804\" data-end=\"4837\"\u003eRelative humidity\u003cbr data-start=\"4821\" data-end=\"4824\"\u003e\u003cstrong data-start=\"4824\" data-end=\"4837\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4839\" data-end=\"4866\"\u003eProtection class\u003cbr data-start=\"4855\" data-end=\"4858\"\u003e\u003cstrong data-start=\"4858\" data-end=\"4866\"\u003eIP43\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4868\" data-end=\"4871\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4873\" data-end=\"4894\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4896\" data-end=\"4938\"\u003eDevice dimensions\u003cbr data-start=\"4913\" data-end=\"4916\"\u003e\u003cstrong data-start=\"4916\" data-end=\"4938\"\u003e333 × 206 × 107 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4940\" data-end=\"4985\"\u003ePackaging dimensions\u003cbr data-start=\"4960\" data-end=\"4963\"\u003e\u003cstrong data-start=\"4963\" data-end=\"4985\"\u003e470 × 380 × 336 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4987\" data-end=\"5010\"\u003eNet weight\u003cbr data-start=\"4997\" data-end=\"5000\"\u003e\u003cstrong data-start=\"5000\" data-end=\"5010\"\u003e4.5 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5012\" data-end=\"5040\"\u003eShipping weight\u003cbr data-start=\"5027\" data-end=\"5030\"\u003e\u003cstrong data-start=\"5030\" data-end=\"5040\"\u003e6.1 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5042\" data-end=\"5045\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"5047\" data-end=\"5067\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"5069\" data-end=\"5104\"\u003eAdapter\u003cbr data-start=\"5076\" data-end=\"5079\"\u003e\u003cstrong data-start=\"5079\" data-end=\"5104\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5106\" data-end=\"5135\"\u003eBalance input\u003cbr data-start=\"5119\" data-end=\"5122\"\u003e\u003cstrong data-start=\"5122\" data-end=\"5135\"\u003e12–15V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5137\" data-end=\"5140\"\u003e\n\u003ch1 data-section-id=\"1g3j9j6\" data-start=\"5142\" data-end=\"5163\"\u003eIncluded Components\u003c\/h1\u003e\n\u003cul data-start=\"5165\" data-end=\"5288\"\u003e\n\u003cli data-section-id=\"1s7eczd\" data-start=\"5165\" data-end=\"5206\"\u003e\n\u003cp data-start=\"5167\" data-end=\"5206\"\u003eRadwag PS 8100.R2.M Precision Balance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z5cw5c\" data-start=\"5207\" data-end=\"5239\"\u003e\n\u003cp data-start=\"5209\" data-end=\"5239\"\u003eStainless Steel Weighing Pan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18vk3g\" data-start=\"5240\" data-end=\"5263\"\u003e\n\u003cp data-start=\"5242\" data-end=\"5263\"\u003eWeighing Pan Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ib4i5v\" data-start=\"5264\" data-end=\"5288\"\u003e\n\u003cp data-start=\"5266\" data-end=\"5288\"\u003ePower Supply Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5290\" data-end=\"5293\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"5295\" data-end=\"5305\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"5307\" data-end=\"5339\"\u003e\u003cstrong data-start=\"5307\" data-end=\"5339\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282626605378,"sku":null,"price":1871.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/PS-R2-nowe_1.jpg?v=1773590625"},{"product_id":"across-international-uya-6-5y-ko-radwag-6-1-g-capacity-0-1-µg-readability-o16-mm-mass-comparator-ultra-microbalance","title":"Across International UYA 6.5Y.KO Radwag 6.1 g Capacity 0.1 µg Readability ø16 mm Mass Comparator Ultra-Microbalance","description":"\u003ch2 data-section-id=\"9q8lvd\" data-start=\"470\" data-end=\"545\"\u003eUltra-High Precision Mass Comparator for Calibration of E1 Class Weights\u003c\/h2\u003e\n\u003cp data-start=\"547\" data-end=\"943\"\u003eThe \u003cstrong data-start=\"551\" data-end=\"589\"\u003eRadwag UYA 6.5Y.KO Mass Comparator\u003c\/strong\u003e is an ultra-high precision metrology instrument designed for \u003cstrong data-start=\"651\" data-end=\"761\"\u003ecalibration and adjustment of mass standards from 1 mg to 5 g in accordance with OIML R111 recommendations\u003c\/strong\u003e. With \u003cstrong data-start=\"768\" data-end=\"820\"\u003e0.1 µg readability and exceptional repeatability\u003c\/strong\u003e, this comparator provides the precision required by accredited calibration laboratories and national metrology institutes.\u003c\/p\u003e\n\u003cp data-start=\"945\" data-end=\"1143\"\u003eRadwag mass comparators are widely used to \u003cstrong data-start=\"988\" data-end=\"1061\"\u003eensure traceability of mass measurements and verify reference weights\u003c\/strong\u003e, supporting legal metrology requirements and international calibration standards.\u003c\/p\u003e\n\u003cp data-start=\"1145\" data-end=\"1442\"\u003eThe \u003cstrong data-start=\"1149\" data-end=\"1212\"\u003eUYA 6.5Y.KO model features an integrated anti-draft chamber\u003c\/strong\u003e, minimizing environmental disturbances such as air currents that can affect ultra-precise measurements. The comparator is housed inside this chamber, and \u003cstrong data-start=\"1367\" data-end=\"1441\"\u003esliding side glass panels allow convenient access to the weighing area\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1444\" data-end=\"1683\"\u003eTo eliminate temperature influence from electronic components, the comparator design separates the \u003cstrong data-start=\"1543\" data-end=\"1601\"\u003eelectronic module from the mechanical measuring system\u003c\/strong\u003e, ensuring stable and accurate measurement results even during extended operation.\u003c\/p\u003e\n\u003cp data-start=\"1685\" data-end=\"1912\"\u003eThe comparator includes a \u003cstrong data-start=\"1711\" data-end=\"1803\"\u003ecylindrical weighing chamber with a glass draft shield and automatic door opening system\u003c\/strong\u003e, while all internal components are constructed from \u003cstrong data-start=\"1856\" data-end=\"1911\"\u003eglass or metal to reduce electrostatic interference\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1914\" data-end=\"1917\"\u003e\n\u003ch1 data-section-id=\"9emtpx\" data-start=\"1919\" data-end=\"1975\"\u003eKey Features of the Radwag UYA 6.5Y.KO Mass Comparator\u003c\/h1\u003e\n\u003ch3 data-section-id=\"17ujzzl\" data-start=\"1977\" data-end=\"2020\"\u003eUltra-Precision Measurement Performance\u003c\/h3\u003e\n\u003cp data-start=\"2021\" data-end=\"2139\"\u003eProvides \u003cstrong data-start=\"2030\" data-end=\"2080\"\u003e0.1 µg readability with 6.1 g maximum capacity\u003c\/strong\u003e, enabling extremely precise calibration of mass standards.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1e8rk4f\" data-start=\"2141\" data-end=\"2165\"\u003eOIML R111 Compliance\u003c\/h3\u003e\n\u003cp data-start=\"2166\" data-end=\"2299\"\u003eDesigned for calibration and verification of \u003cstrong data-start=\"2211\" data-end=\"2249\"\u003eE1 class weights and lower classes\u003c\/strong\u003e in accordance with \u003cstrong data-start=\"2269\" data-end=\"2298\"\u003eOIML R111 recommendations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14odwha\" data-start=\"2301\" data-end=\"2323\"\u003eAnti-Draft Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2324\" data-end=\"2431\"\u003eThe standard anti-draft chamber minimizes environmental disturbances and stabilizes measurement conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zs1np0\" data-start=\"2433\" data-end=\"2478\"\u003eAdvanced Mechanical-Electronic Separation\u003c\/h3\u003e\n\u003cp data-start=\"2479\" data-end=\"2591\"\u003eSeparate electronic and mechanical modules eliminate temperature effects caused by electronic component heating.\u003c\/p\u003e\n\u003ch3 data-section-id=\"p8zxwg\" data-start=\"2593\" data-end=\"2625\"\u003eCylindrical Weighing Chamber\u003c\/h3\u003e\n\u003cp data-start=\"2626\" data-end=\"2697\"\u003eThe comparator features an aesthetic cylindrical weighing chamber with:\u003c\/p\u003e\n\u003cul data-start=\"2699\" data-end=\"2788\"\u003e\n\u003cli data-section-id=\"16tjr6g\" data-start=\"2699\" data-end=\"2719\"\u003e\n\u003cp data-start=\"2701\" data-end=\"2719\"\u003eGlass draft shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvv35e\" data-start=\"2720\" data-end=\"2751\"\u003e\n\u003cp data-start=\"2722\" data-end=\"2751\"\u003eAutomatic door opening system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"222pu5\" data-start=\"2752\" data-end=\"2788\"\u003e\n\u003cp data-start=\"2754\" data-end=\"2788\"\u003eMinimal electrostatic interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"6an82j\" data-start=\"2790\" data-end=\"2818\"\u003eElectrostatic Resistance\u003c\/h3\u003e\n\u003cp data-start=\"2819\" data-end=\"2948\"\u003eAll chamber components are constructed from \u003cstrong data-start=\"2863\" data-end=\"2892\"\u003eglass and metal materials\u003c\/strong\u003e, reducing electrostatic effects on measurement results.\u003c\/p\u003e\n\u003ch3 data-section-id=\"perrlk\" data-start=\"2950\" data-end=\"2979\"\u003e10″ Touchscreen Interface\u003c\/h3\u003e\n\u003cp data-start=\"2980\" data-end=\"3092\"\u003eA large \u003cstrong data-start=\"2988\" data-end=\"3020\"\u003e10-inch touchscreen terminal\u003c\/strong\u003e provides intuitive control and clear visualization of measurement data.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hkwe4d\" data-start=\"3094\" data-end=\"3119\"\u003eAdvanced Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3120\" data-end=\"3153\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"3155\" data-end=\"3246\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"3155\" data-end=\"3169\"\u003e\n\u003cp data-start=\"3157\" data-end=\"3169\"\u003e\u003cstrong data-start=\"3157\" data-end=\"3169\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"3170\" data-end=\"3181\"\u003e\n\u003cp data-start=\"3172\" data-end=\"3181\"\u003e\u003cstrong data-start=\"3172\" data-end=\"3181\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"3182\" data-end=\"3192\"\u003e\n\u003cp data-start=\"3184\" data-end=\"3192\"\u003e\u003cstrong data-start=\"3184\" data-end=\"3192\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"3193\" data-end=\"3207\"\u003e\n\u003cp data-start=\"3195\" data-end=\"3207\"\u003e\u003cstrong data-start=\"3195\" data-end=\"3207\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"3208\" data-end=\"3219\"\u003e\n\u003cp data-start=\"3210\" data-end=\"3219\"\u003e\u003cstrong data-start=\"3210\" data-end=\"3219\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"3220\" data-end=\"3246\"\u003e\n\u003cp data-start=\"3222\" data-end=\"3246\"\u003e\u003cstrong data-start=\"3222\" data-end=\"3246\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3248\" data-end=\"3336\"\u003eThis enables seamless integration with laboratory data systems and calibration software.\u003c\/p\u003e\n\u003chr data-start=\"3338\" data-end=\"3341\"\u003e\n\u003ch1 data-section-id=\"c3mln3\" data-start=\"3343\" data-end=\"3357\"\u003eApplications\u003c\/h1\u003e\n\u003cp data-start=\"3359\" data-end=\"3462\"\u003eThe Radwag UYA 6.5Y.KO mass comparator is designed for high-precision metrology applications including:\u003c\/p\u003e\n\u003cul data-start=\"3464\" data-end=\"3690\"\u003e\n\u003cli data-section-id=\"16uiccp\" data-start=\"3464\" data-end=\"3503\"\u003e\n\u003cp data-start=\"3466\" data-end=\"3503\"\u003eAccredited calibration laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"b7igxs\" data-start=\"3504\" data-end=\"3537\"\u003e\n\u003cp data-start=\"3506\" data-end=\"3537\"\u003eNational metrology institutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1atifx2\" data-start=\"3538\" data-end=\"3578\"\u003e\n\u003cp data-start=\"3540\" data-end=\"3578\"\u003eMass standard calibration facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hzmbmo\" data-start=\"3579\" data-end=\"3616\"\u003e\n\u003cp data-start=\"3581\" data-end=\"3616\"\u003eVerification of reference weights\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pjgy36\" data-start=\"3617\" data-end=\"3649\"\u003e\n\u003cp data-start=\"3619\" data-end=\"3649\"\u003eLegal metrology laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h53awx\" data-start=\"3650\" data-end=\"3690\"\u003e\n\u003cp data-start=\"3652\" data-end=\"3690\"\u003eHigh-precision research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3692\" data-end=\"3695\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3697\" data-end=\"3723\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"3725\" data-end=\"3733\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"3734\" data-end=\"3749\"\u003e\u003cstrong data-start=\"3734\" data-end=\"3749\"\u003eUYA 6.5Y.KO\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3751\" data-end=\"3779\"\u003ePart Number: \u003cstrong data-start=\"3764\" data-end=\"3779\"\u003eWL-408-0007\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3781\" data-end=\"3784\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"3786\" data-end=\"3808\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"3810\" data-end=\"3838\"\u003eMaximum capacity\u003cbr data-start=\"3826\" data-end=\"3829\"\u003e\u003cstrong data-start=\"3829\" data-end=\"3838\"\u003e6.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3840\" data-end=\"3864\"\u003eReadability\u003cbr data-start=\"3851\" data-end=\"3854\"\u003e\u003cstrong data-start=\"3854\" data-end=\"3864\"\u003e0.1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3866\" data-end=\"3909\"\u003eElectric compensation range\u003cbr data-start=\"3893\" data-end=\"3896\"\u003e\u003cstrong data-start=\"3896\" data-end=\"3909\"\u003e0 – 6.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3911\" data-end=\"3914\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"3916\" data-end=\"3926\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"3928\" data-end=\"3963\"\u003eRepeatability (5% Max)\u003cbr data-start=\"3950\" data-end=\"3953\"\u003e\u003cstrong data-start=\"3953\" data-end=\"3963\"\u003e0.2 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3965\" data-end=\"3997\"\u003eRepeatability (Max)\u003cbr data-start=\"3984\" data-end=\"3987\"\u003e\u003cstrong data-start=\"3987\" data-end=\"3997\"\u003e0.4 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3999\" data-end=\"4037\"\u003ePermissible repeatability\u003cbr data-start=\"4024\" data-end=\"4027\"\u003e\u003cstrong data-start=\"4027\" data-end=\"4037\"\u003e0.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4039\" data-end=\"4081\"\u003eEccentricity (tested load)\u003cbr data-start=\"4065\" data-end=\"4068\"\u003e\u003cstrong data-start=\"4068\" data-end=\"4081\"\u003e1d \/ 1 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4083\" data-end=\"4126\"\u003eStabilization time\u003cbr data-start=\"4101\" data-end=\"4104\"\u003e\u003cstrong data-start=\"4104\" data-end=\"4126\"\u003eMaximum 30 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4128\" data-end=\"4131\"\u003e\n\u003ch1 data-section-id=\"uke8o9\" data-start=\"4133\" data-end=\"4145\"\u003eAdjustment\u003c\/h1\u003e\n\u003cp data-start=\"4147\" data-end=\"4180\"\u003e\u003cstrong data-start=\"4147\" data-end=\"4180\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4182\" data-end=\"4185\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"4187\" data-end=\"4196\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"4198\" data-end=\"4221\"\u003e\u003cstrong data-start=\"4198\" data-end=\"4221\"\u003e10-inch touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4223\" data-end=\"4226\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"4228\" data-end=\"4242\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"4244\" data-end=\"4277\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"4279\" data-end=\"4357\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"4279\" data-end=\"4293\"\u003e\n\u003cp data-start=\"4281\" data-end=\"4293\"\u003e\u003cstrong data-start=\"4281\" data-end=\"4293\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"4294\" data-end=\"4305\"\u003e\n\u003cp data-start=\"4296\" data-end=\"4305\"\u003e\u003cstrong data-start=\"4296\" data-end=\"4305\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"4306\" data-end=\"4316\"\u003e\n\u003cp data-start=\"4308\" data-end=\"4316\"\u003e\u003cstrong data-start=\"4308\" data-end=\"4316\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"4317\" data-end=\"4331\"\u003e\n\u003cp data-start=\"4319\" data-end=\"4331\"\u003e\u003cstrong data-start=\"4319\" data-end=\"4331\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"4332\" data-end=\"4343\"\u003e\n\u003cp data-start=\"4334\" data-end=\"4343\"\u003e\u003cstrong data-start=\"4334\" data-end=\"4343\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mf3ibn\" data-start=\"4344\" data-end=\"4357\"\u003e\n\u003cp data-start=\"4346\" data-end=\"4357\"\u003e\u003cstrong data-start=\"4346\" data-end=\"4357\"\u003eHotspot\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4359\" data-end=\"4362\"\u003e\n\u003ch1 data-section-id=\"gd4auq\" data-start=\"4364\" data-end=\"4392\"\u003eEnvironmental Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4394\" data-end=\"4433\"\u003eOperating temperature\u003cbr data-start=\"4415\" data-end=\"4418\"\u003e\u003cstrong data-start=\"4418\" data-end=\"4433\"\u003e15°C – 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4435\" data-end=\"4492\"\u003eTemperature stability requirement\u003cbr data-start=\"4468\" data-end=\"4471\"\u003e\u003cstrong data-start=\"4471\" data-end=\"4492\"\u003e±0.5°C \/ 12 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4494\" data-end=\"4527\"\u003eRelative humidity\u003cbr data-start=\"4511\" data-end=\"4514\"\u003e\u003cstrong data-start=\"4514\" data-end=\"4527\"\u003e40% – 60%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4529\" data-end=\"4569\"\u003eHumidity change rate\u003cbr data-start=\"4549\" data-end=\"4552\"\u003e\u003cstrong data-start=\"4552\" data-end=\"4569\"\u003e±2% \/ 4 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4571\" data-end=\"4574\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"4576\" data-end=\"4594\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"4596\" data-end=\"4620\"\u003ePan diameter\u003cbr data-start=\"4608\" data-end=\"4611\"\u003e\u003cstrong data-start=\"4611\" data-end=\"4620\"\u003e16 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4622\" data-end=\"4665\"\u003eChamber dimensions\u003cbr data-start=\"4640\" data-end=\"4643\"\u003e\u003cstrong data-start=\"4643\" data-end=\"4665\"\u003e820 × 840 × 630 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4667\" data-end=\"4670\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"4672\" data-end=\"4693\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"4695\" data-end=\"4738\"\u003ePackage dimensions\u003cbr data-start=\"4713\" data-end=\"4716\"\u003e\u003cstrong data-start=\"4716\" data-end=\"4738\"\u003e655 × 755 × 445 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4740\" data-end=\"4764\"\u003eUnit weight\u003cbr data-start=\"4751\" data-end=\"4754\"\u003e\u003cstrong data-start=\"4754\" data-end=\"4764\"\u003e23 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4766\" data-end=\"4794\"\u003eShipping weight\u003cbr data-start=\"4781\" data-end=\"4784\"\u003e\u003cstrong data-start=\"4784\" data-end=\"4794\"\u003e40 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4796\" data-end=\"4799\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"4801\" data-end=\"4821\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"4823\" data-end=\"4858\"\u003eAdapter\u003cbr data-start=\"4830\" data-end=\"4833\"\u003e\u003cstrong data-start=\"4833\" data-end=\"4858\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4860\" data-end=\"4863\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"4865\" data-end=\"4875\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"4877\" data-end=\"4909\"\u003e\u003cstrong data-start=\"4877\" data-end=\"4909\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282629914946,"sku":null,"price":40680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/WL-408-0007-removebg-preview.png?v=1773590799"},{"product_id":"across-international-uya-2-5y-radwag-2-1-g-capacity-0-1-µg-readability-o16-mm-ultra-microbalance","title":"Across International UYA 2.5Y Radwag 2.1 g Capacity 0.1 µg Readability ø16 mm Ultra-Microbalance","description":"\u003ch2 data-section-id=\"1spuhwk\" data-start=\"346\" data-end=\"428\"\u003eUltra-Precision Microbalance with ELLIPSIS Smart Technology and 10″ Touchscreen\u003c\/h2\u003e\n\u003cp data-start=\"430\" data-end=\"802\"\u003eThe \u003cstrong data-start=\"434\" data-end=\"472\"\u003eRadwag UYA 2.5Y Ultra-Microbalance\u003c\/strong\u003e is an advanced laboratory weighing instrument designed for \u003cstrong data-start=\"532\" data-end=\"582\"\u003eextremely precise microgram-level measurements\u003c\/strong\u003e. With \u003cstrong data-start=\"589\" data-end=\"638\"\u003e0.1 µg readability and 2.1 g maximum capacity\u003c\/strong\u003e, the UYA 2.5Y is ideal for demanding analytical applications including pharmaceutical research, nanotechnology, microchemical analysis, and metrology laboratories.\u003c\/p\u003e\n\u003cp data-start=\"804\" data-end=\"1151\"\u003ePart of the \u003cstrong data-start=\"816\" data-end=\"842\"\u003eRadwag ELLIPSIS series\u003c\/strong\u003e, this ultra-microbalance incorporates intelligent technologies such as the \u003cstrong data-start=\"918\" data-end=\"1049\"\u003eDigital Weighing Auditor, ReflexLEVEL automatic leveling system, Smart Minimum Weight monitoring, and air buoyancy compensation\u003c\/strong\u003e. These features ensure optimal measurement conditions and help maintain consistent weighing accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1500\"\u003eThe balance is equipped with a powerful \u003cstrong data-start=\"1193\" data-end=\"1226\"\u003e10-inch touchscreen interface\u003c\/strong\u003e that allows intuitive operation and displays detailed measurement data, graphs, and system status information. Advanced connectivity options including \u003cstrong data-start=\"1378\" data-end=\"1429\"\u003eUSB, Ethernet, Wi-Fi, and hotspot functionality\u003c\/strong\u003e allow seamless integration with modern laboratory information systems.\u003c\/p\u003e\n\u003chr data-start=\"1502\" data-end=\"1505\"\u003e\n\u003ch1 data-section-id=\"136hgz6\" data-start=\"1507\" data-end=\"1563\"\u003eKey Features of the Radwag UYA 2.5Y Ultra-Microbalance\u003c\/h1\u003e\n\u003ch3 data-section-id=\"5d6a8p\" data-start=\"1565\" data-end=\"1598\"\u003eUltra-High Precision Weighing\u003c\/h3\u003e\n\u003cp data-start=\"1599\" data-end=\"1732\"\u003eProvides \u003cstrong data-start=\"1608\" data-end=\"1650\"\u003e0.1 µg readability with 2.1 g capacity\u003c\/strong\u003e, enabling extremely precise measurements for micro-scale laboratory applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kbskc8\" data-start=\"1734\" data-end=\"1762\"\u003eDigital Weighing Auditor\u003c\/h3\u003e\n\u003cp data-start=\"1763\" data-end=\"1978\"\u003eThe built-in \u003cstrong data-start=\"1776\" data-end=\"1804\"\u003eDigital Weighing Auditor\u003c\/strong\u003e continuously checks that the balance is ready for use. It performs \u003cstrong data-start=\"1872\" data-end=\"1911\"\u003ereal-time air buoyancy compensation\u003c\/strong\u003e and notifies users when inspection or calibration may be required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1105f9u\" data-start=\"1980\" data-end=\"2016\"\u003e10″ ELLIPSIS Touchscreen Display\u003c\/h3\u003e\n\u003cp data-start=\"2017\" data-end=\"2061\"\u003eThe advanced touchscreen interface displays:\u003c\/p\u003e\n\u003cul data-start=\"2063\" data-end=\"2178\"\u003e\n\u003cli data-section-id=\"1jocsql\" data-start=\"2063\" data-end=\"2083\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2083\"\u003eMeasurement graphs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"978wrl\" data-start=\"2084\" data-end=\"2102\"\u003e\n\u003cp data-start=\"2086\" data-end=\"2102\"\u003eProcess statuses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u6op0w\" data-start=\"2103\" data-end=\"2118\"\u003e\n\u003cp data-start=\"2105\" data-end=\"2118\"\u003eSystem alerts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"154ph5s\" data-start=\"2119\" data-end=\"2140\"\u003e\n\u003cp data-start=\"2121\" data-end=\"2140\"\u003eMeasurement history\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pwizk1\" data-start=\"2141\" data-end=\"2178\"\u003e\n\u003cp data-start=\"2143\" data-end=\"2178\"\u003eCustomizable widgets and dashboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2180\" data-end=\"2248\"\u003eUp to \u003cstrong data-start=\"2186\" data-end=\"2247\"\u003ethree information screens can be displayed simultaneously\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14xsojt\" data-start=\"2250\" data-end=\"2282\"\u003eAdvanced User Authentication\u003c\/h3\u003e\n\u003cp data-start=\"2283\" data-end=\"2332\"\u003eSupports multiple verification methods including:\u003c\/p\u003e\n\u003cul data-start=\"2334\" data-end=\"2439\"\u003e\n\u003cli data-section-id=\"1wey4b8\" data-start=\"2334\" data-end=\"2350\"\u003e\n\u003cp data-start=\"2336\" data-end=\"2350\"\u003ePassword login\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13wy6n9\" data-start=\"2351\" data-end=\"2362\"\u003e\n\u003cp data-start=\"2353\" data-end=\"2362\"\u003eRFID card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c2da4v\" data-start=\"2363\" data-end=\"2388\"\u003e\n\u003cp data-start=\"2365\" data-end=\"2388\"\u003eFingerprint recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1226wof\" data-start=\"2389\" data-end=\"2409\"\u003e\n\u003cp data-start=\"2391\" data-end=\"2409\"\u003eFacial recognition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"anx8qp\" data-start=\"2410\" data-end=\"2439\"\u003e\n\u003cp data-start=\"2412\" data-end=\"2439\"\u003eMulti-factor authentication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1hvy53l\" data-start=\"2441\" data-end=\"2472\"\u003eAmbient Light Status System\u003c\/h3\u003e\n\u003cp data-start=\"2473\" data-end=\"2585\"\u003eIntegrated ambient lighting communicates balance status, measurement results, and alerts using color indicators.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17ceyjf\" data-start=\"2587\" data-end=\"2621\"\u003eReflexLEVEL Automatic Leveling\u003c\/h3\u003e\n\u003cp data-start=\"2622\" data-end=\"2750\"\u003eThe \u003cstrong data-start=\"2626\" data-end=\"2681\"\u003eReflexLEVEL system automatically levels the balance\u003c\/strong\u003e, eliminating manual adjustments and improving measurement precision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rwqjgl\" data-start=\"2752\" data-end=\"2787\"\u003eSmart Minimum Weight Monitoring\u003c\/h3\u003e\n\u003cp data-start=\"2788\" data-end=\"2913\"\u003eDisplays whether the current sample weight is above or below the required minimum weight threshold for accurate measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hdcg1t\" data-start=\"2915\" data-end=\"2935\"\u003eRFID Integration\u003c\/h3\u003e\n\u003cp data-start=\"2936\" data-end=\"3045\"\u003eRFID tags can be used to identify users, samples, and formulation ingredients stored in the balance database.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hd4mdk\" data-start=\"3047\" data-end=\"3071\"\u003eHotspot Connectivity\u003c\/h3\u003e\n\u003cp data-start=\"3072\" data-end=\"3186\"\u003eThe balance can create its own \u003cstrong data-start=\"3103\" data-end=\"3120\"\u003eWi-Fi hotspot\u003c\/strong\u003e, allowing smartphones, tablets, or computers to connect directly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qzkj2r\" data-start=\"3188\" data-end=\"3202\"\u003eLive Notes\u003c\/h3\u003e\n\u003cp data-start=\"3203\" data-end=\"3296\"\u003eUsers can attach \u003cstrong data-start=\"3220\" data-end=\"3249\"\u003evoice memos or text notes\u003c\/strong\u003e to measurement procedures or weighing reports.\u003c\/p\u003e\n\u003ch3 data-section-id=\"48055v\" data-start=\"3298\" data-end=\"3315\"\u003eHandy Library\u003c\/h3\u003e\n\u003cp data-start=\"3316\" data-end=\"3341\"\u003eProvides quick access to:\u003c\/p\u003e\n\u003cul data-start=\"3343\" data-end=\"3458\"\u003e\n\u003cli data-section-id=\"1oikouq\" data-start=\"3343\" data-end=\"3370\"\u003e\n\u003cp data-start=\"3345\" data-end=\"3370\"\u003eRecent measurement series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fqz3zv\" data-start=\"3371\" data-end=\"3408\"\u003e\n\u003cp data-start=\"3373\" data-end=\"3408\"\u003eReports ready for digital signature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"55fpuc\" data-start=\"3409\" data-end=\"3458\"\u003e\n\u003cp data-start=\"3411\" data-end=\"3458\"\u003eDocumentation compliant with \u003cstrong data-start=\"3440\" data-end=\"3458\"\u003e21 CFR Part 11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"yt04p0\" data-start=\"3460\" data-end=\"3484\"\u003eTwo-Point Adjustment\u003c\/h3\u003e\n\u003cp data-start=\"3485\" data-end=\"3574\"\u003eCalibration at two measurement points improves accuracy across the entire weighing range.\u003c\/p\u003e\n\u003chr data-start=\"3576\" data-end=\"3579\"\u003e\n\u003ch1 data-section-id=\"qb0m5\" data-start=\"3581\" data-end=\"3610\"\u003eAdvanced Weighing Functions\u003c\/h1\u003e\n\u003cp data-start=\"3612\" data-end=\"3697\"\u003eThe UYA 2.5Y ultra-microbalance supports a wide range of professional weighing modes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"flduv3\" data-start=\"3699\" data-end=\"3711\"\u003eAutotest\u003c\/h3\u003e\n\u003cp data-start=\"3712\" data-end=\"3795\"\u003eAutomatic diagnostics determine metrological parameters and optimize weighing time.\u003c\/p\u003e\n\u003ch3 data-section-id=\"grqcke\" data-start=\"3797\" data-end=\"3807\"\u003eDosing\u003c\/h3\u003e\n\u003cp data-start=\"3808\" data-end=\"3886\"\u003eAllows controlled dosing based on reference mass and defined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"15k2ju1\" data-start=\"3888\" data-end=\"3908\"\u003ePercent Weighing\u003c\/h3\u003e\n\u003cp data-start=\"3909\" data-end=\"3975\"\u003eDisplays sample mass relative to a reference mass as a percentage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1mxb2qp\" data-start=\"3977\" data-end=\"3995\"\u003eParts Counting\u003c\/h3\u003e\n\u003cp data-start=\"3996\" data-end=\"4072\"\u003eDetermines quantity based on unit weight with automatic accuracy correction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nnh1is\" data-start=\"4074\" data-end=\"4089\"\u003eFormulation\u003c\/h3\u003e\n\u003cp data-start=\"4090\" data-end=\"4165\"\u003eSupports preparation of multi-component mixtures with tolerance monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1agpw9b\" data-start=\"4167\" data-end=\"4191\"\u003eStatistical Analysis\u003c\/h3\u003e\n\u003cp data-start=\"4192\" data-end=\"4234\"\u003eProvides measurement statistics including:\u003c\/p\u003e\n\u003cul data-start=\"4236\" data-end=\"4329\"\u003e\n\u003cli data-section-id=\"1tpje4l\" data-start=\"4236\" data-end=\"4264\"\u003e\n\u003cp data-start=\"4238\" data-end=\"4264\"\u003eMaximum and minimum values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cmuxs4\" data-start=\"4265\" data-end=\"4277\"\u003e\n\u003cp data-start=\"4267\" data-end=\"4277\"\u003eMean value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yvyhm8\" data-start=\"4278\" data-end=\"4298\"\u003e\n\u003cp data-start=\"4280\" data-end=\"4298\"\u003eStandard deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dwk9jh\" data-start=\"4299\" data-end=\"4309\"\u003e\n\u003cp data-start=\"4301\" data-end=\"4309\"\u003eVariance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xk4t9\" data-start=\"4310\" data-end=\"4329\"\u003e\n\u003cp data-start=\"4312\" data-end=\"4329\"\u003eMeasurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"a1clir\" data-start=\"4331\" data-end=\"4356\"\u003eDifferential Weighing\u003c\/h3\u003e\n\u003cp data-start=\"4357\" data-end=\"4425\"\u003eMeasures mass changes during manufacturing or processing operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1prc4ok\" data-start=\"4427\" data-end=\"4444\"\u003eCheckweighing\u003c\/h3\u003e\n\u003cp data-start=\"4445\" data-end=\"4513\"\u003eIndicates whether a sample falls within predefined tolerance limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13ojh26\" data-start=\"4515\" data-end=\"4538\"\u003eIR Sensor Operation\u003c\/h3\u003e\n\u003cp data-start=\"4539\" data-end=\"4641\"\u003eTouch-free infrared sensors allow users to perform operations without physically touching the balance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nsgw6r\" data-start=\"4643\" data-end=\"4660\"\u003eGLP Reporting\u003c\/h3\u003e\n\u003cp data-start=\"4661\" data-end=\"4727\"\u003eSupports \u003cstrong data-start=\"4670\" data-end=\"4726\"\u003eGood Laboratory Practice documentation and reporting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4729\" data-end=\"4732\"\u003e\n\u003ch1 data-section-id=\"1jn9okq\" data-start=\"4734\" data-end=\"4754\"\u003eIdeal Applications\u003c\/h1\u003e\n\u003cp data-start=\"4756\" data-end=\"4815\"\u003eThe Radwag UYA 2.5Y ultra-microbalance is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"4817\" data-end=\"5005\"\u003e\n\u003cli data-section-id=\"qbdgru\" data-start=\"4817\" data-end=\"4848\"\u003e\n\u003cp data-start=\"4819\" data-end=\"4848\"\u003ePharmaceutical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ktawpv\" data-start=\"4849\" data-end=\"4886\"\u003e\n\u003cp data-start=\"4851\" data-end=\"4886\"\u003eAnalytical chemistry laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"126lv89\" data-start=\"4887\" data-end=\"4914\"\u003e\n\u003cp data-start=\"4889\" data-end=\"4914\"\u003eNanotechnology research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cac3vx\" data-start=\"4915\" data-end=\"4940\"\u003e\n\u003cp data-start=\"4917\" data-end=\"4940\"\u003eMicro-sample weighing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mxadkh\" data-start=\"4941\" data-end=\"4967\"\u003e\n\u003cp data-start=\"4943\" data-end=\"4967\"\u003eMetrology laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xykno0\" data-start=\"4968\" data-end=\"5005\"\u003e\n\u003cp data-start=\"4970\" data-end=\"5005\"\u003eBiotechnology research facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5007\" data-end=\"5010\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"5012\" data-end=\"5038\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003ch2 data-section-id=\"xgagqy\" data-start=\"5040\" data-end=\"5048\"\u003eModel\u003c\/h2\u003e\n\u003cp data-start=\"5049\" data-end=\"5061\"\u003e\u003cstrong data-start=\"5049\" data-end=\"5061\"\u003eUYA 2.5Y\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5063\" data-end=\"5091\"\u003ePart Number: \u003cstrong data-start=\"5076\" data-end=\"5091\"\u003eWL-109-0001\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5093\" data-end=\"5096\"\u003e\n\u003ch1 data-section-id=\"1us6owa\" data-start=\"5098\" data-end=\"5120\"\u003eWeighing Performance\u003c\/h1\u003e\n\u003cp data-start=\"5122\" data-end=\"5150\"\u003eMaximum capacity\u003cbr data-start=\"5138\" data-end=\"5141\"\u003e\u003cstrong data-start=\"5141\" data-end=\"5150\"\u003e2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5152\" data-end=\"5178\"\u003eMinimum load\u003cbr data-start=\"5164\" data-end=\"5167\"\u003e\u003cstrong data-start=\"5167\" data-end=\"5178\"\u003e0.01 mg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5180\" data-end=\"5204\"\u003eReadability\u003cbr data-start=\"5191\" data-end=\"5194\"\u003e\u003cstrong data-start=\"5194\" data-end=\"5204\"\u003e0.1 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5206\" data-end=\"5229\"\u003eTare range\u003cbr data-start=\"5216\" data-end=\"5219\"\u003e\u003cstrong data-start=\"5219\" data-end=\"5229\"\u003e−2.1 g\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5231\" data-end=\"5234\"\u003e\n\u003ch1 data-section-id=\"5csikb\" data-start=\"5236\" data-end=\"5246\"\u003eAccuracy\u003c\/h1\u003e\n\u003cp data-start=\"5248\" data-end=\"5284\"\u003eRepeatability (5% Max)\u003cbr data-start=\"5270\" data-end=\"5273\"\u003e\u003cstrong data-start=\"5273\" data-end=\"5284\"\u003e0.15 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5286\" data-end=\"5319\"\u003eRepeatability (Max)\u003cbr data-start=\"5305\" data-end=\"5308\"\u003e\u003cstrong data-start=\"5308\" data-end=\"5319\"\u003e0.35 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5321\" data-end=\"5369\"\u003ePermissible repeatability (5% Max)\u003cbr data-start=\"5355\" data-end=\"5358\"\u003e\u003cstrong data-start=\"5358\" data-end=\"5369\"\u003e0.35 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5371\" data-end=\"5415\"\u003ePermissible repeatability (Max)\u003cbr data-start=\"5402\" data-end=\"5405\"\u003e\u003cstrong data-start=\"5405\" data-end=\"5415\"\u003e0.6 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5417\" data-end=\"5440\"\u003eLinearity\u003cbr data-start=\"5426\" data-end=\"5429\"\u003e\u003cstrong data-start=\"5429\" data-end=\"5440\"\u003e±1.5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5442\" data-end=\"5479\"\u003eEccentric load deviation\u003cbr data-start=\"5466\" data-end=\"5469\"\u003e\u003cstrong data-start=\"5469\" data-end=\"5479\"\u003e1.5 µg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5481\" data-end=\"5519\"\u003eStabilization time\u003cbr data-start=\"5499\" data-end=\"5502\"\u003e\u003cstrong data-start=\"5502\" data-end=\"5519\"\u003e10–20 seconds\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5521\" data-end=\"5524\"\u003e\n\u003ch1 data-section-id=\"1mcqff0\" data-start=\"5526\" data-end=\"5539\"\u003eCalibration\u003c\/h1\u003e\n\u003cp data-start=\"5541\" data-end=\"5574\"\u003e\u003cstrong data-start=\"5541\" data-end=\"5574\"\u003eInternal automatic adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5576\" data-end=\"5579\"\u003e\n\u003ch1 data-section-id=\"1vfvk6v\" data-start=\"5581\" data-end=\"5602\"\u003eOIML Classification\u003c\/h1\u003e\n\u003cp data-start=\"5604\" data-end=\"5615\"\u003e\u003cstrong data-start=\"5604\" data-end=\"5615\"\u003eClass I\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5617\" data-end=\"5620\"\u003e\n\u003ch1 data-section-id=\"1ks31h8\" data-start=\"5622\" data-end=\"5631\"\u003eDisplay\u003c\/h1\u003e\n\u003cp data-start=\"5633\" data-end=\"5656\"\u003e\u003cstrong data-start=\"5633\" data-end=\"5656\"\u003e10-inch touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"5658\" data-end=\"5661\"\u003e\n\u003ch1 data-section-id=\"h6jvsz\" data-start=\"5663\" data-end=\"5677\"\u003eConnectivity\u003c\/h1\u003e\n\u003cp data-start=\"5679\" data-end=\"5712\"\u003eCommunication interfaces include:\u003c\/p\u003e\n\u003cul data-start=\"5714\" data-end=\"5805\"\u003e\n\u003cli data-section-id=\"1xycf51\" data-start=\"5714\" data-end=\"5728\"\u003e\n\u003cp data-start=\"5716\" data-end=\"5728\"\u003e\u003cstrong data-start=\"5716\" data-end=\"5728\"\u003eUSB-A ×2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ueq5he\" data-start=\"5729\" data-end=\"5740\"\u003e\n\u003cp data-start=\"5731\" data-end=\"5740\"\u003e\u003cstrong data-start=\"5731\" data-end=\"5740\"\u003eUSB-C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2998ao\" data-start=\"5741\" data-end=\"5751\"\u003e\n\u003cp data-start=\"5743\" data-end=\"5751\"\u003e\u003cstrong data-start=\"5743\" data-end=\"5751\"\u003eHDMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"m2tfo9\" data-start=\"5752\" data-end=\"5766\"\u003e\n\u003cp data-start=\"5754\" data-end=\"5766\"\u003e\u003cstrong data-start=\"5754\" data-end=\"5766\"\u003eEthernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137x6yc\" data-start=\"5767\" data-end=\"5778\"\u003e\n\u003cp data-start=\"5769\" data-end=\"5778\"\u003e\u003cstrong data-start=\"5769\" data-end=\"5778\"\u003eWi-Fi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ty4hqe\" data-start=\"5779\" data-end=\"5805\"\u003e\n\u003cp data-start=\"5781\" data-end=\"5805\"\u003e\u003cstrong data-start=\"5781\" data-end=\"5805\"\u003eHotspot connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5807\" data-end=\"5810\"\u003e\n\u003ch1 data-section-id=\"7w43y3\" data-start=\"5812\" data-end=\"5834\"\u003eOperating Conditions\u003c\/h1\u003e\n\u003cp data-start=\"5836\" data-end=\"5875\"\u003eOperating temperature\u003cbr data-start=\"5857\" data-end=\"5860\"\u003e\u003cstrong data-start=\"5860\" data-end=\"5875\"\u003e10°C – 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5877\" data-end=\"5922\"\u003eTemperature change rate\u003cbr data-start=\"5900\" data-end=\"5903\"\u003e\u003cstrong data-start=\"5903\" data-end=\"5922\"\u003e±0.3°C per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5924\" data-end=\"5957\"\u003eRelative humidity\u003cbr data-start=\"5941\" data-end=\"5944\"\u003e\u003cstrong data-start=\"5944\" data-end=\"5957\"\u003e40% – 80%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5959\" data-end=\"6001\"\u003eHumidity change rate\u003cbr data-start=\"5979\" data-end=\"5982\"\u003e\u003cstrong data-start=\"5982\" data-end=\"6001\"\u003e±1% per 8 hours\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6003\" data-end=\"6006\"\u003e\n\u003ch1 data-section-id=\"x7q2cg\" data-start=\"6008\" data-end=\"6026\"\u003eWeighing Chamber\u003c\/h1\u003e\n\u003cp data-start=\"6028\" data-end=\"6052\"\u003ePan diameter\u003cbr data-start=\"6040\" data-end=\"6043\"\u003e\u003cstrong data-start=\"6043\" data-end=\"6052\"\u003e16 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6054\" data-end=\"6089\"\u003eChamber dimensions\u003cbr data-start=\"6072\" data-end=\"6075\"\u003e\u003cstrong data-start=\"6075\" data-end=\"6089\"\u003e90 × 90 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6091\" data-end=\"6094\"\u003e\n\u003ch1 data-section-id=\"ecdisj\" data-start=\"6096\" data-end=\"6117\"\u003eDimensions \u0026amp; Weight\u003c\/h1\u003e\n\u003cp data-start=\"6119\" data-end=\"6184\"\u003ePackage dimensions\u003cbr data-start=\"6137\" data-end=\"6140\"\u003e\u003cstrong data-start=\"6140\" data-end=\"6184\"\u003e655 × 755 × 445 mm (26 × 30 × 18 inches)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6186\" data-end=\"6210\"\u003eUnit weight\u003cbr data-start=\"6197\" data-end=\"6200\"\u003e\u003cstrong data-start=\"6200\" data-end=\"6210\"\u003e23 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6212\" data-end=\"6240\"\u003eShipping weight\u003cbr data-start=\"6227\" data-end=\"6230\"\u003e\u003cstrong data-start=\"6230\" data-end=\"6240\"\u003e38 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6242\" data-end=\"6245\"\u003e\n\u003ch1 data-section-id=\"5ngydx\" data-start=\"6247\" data-end=\"6267\"\u003ePower Requirements\u003c\/h1\u003e\n\u003cp data-start=\"6269\" data-end=\"6294\"\u003e\u003cstrong data-start=\"6269\" data-end=\"6294\"\u003e100–240V AC, 50\/60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"6296\" data-end=\"6299\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"6301\" data-end=\"6311\"\u003eWarranty\u003c\/h1\u003e\n\u003cp data-start=\"6313\" data-end=\"6345\"\u003e\u003cstrong data-start=\"6313\" data-end=\"6345\"\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":52282631127362,"sku":null,"price":44915.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/files\/WL-408-0007-removebg-preview_1.webp?v=1773590944"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/8773\/6642\/collections\/precision-balance-wlc-r_wlc-60c2r--wl-206-0063-_1.jpg?v=1773587752","url":"https:\/\/summitsupplydirect.com\/collections\/laboratory-balances.oembed","provider":"Summit Supply Direct","version":"1.0","type":"link"}